-mNC6 Committed to Nuclear Excelence Praire Island Nuclear Generating Plant Operated by Nuclear Management Company, LLC L-PI-03-094 Technical Specification 5.6.7 October 24, 2003 U S Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT DOCKET NO. 50-306 LICENSE NO. DPR-60 2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS - 15 DAY REPORT In accordance with Technical Specification 5.6.7.1, the number of tubes plugged or sleeved in each steam generator is provided in Table 1.

Prairie Island Unit 2 RF022 Plug s and Sleeves EOC 21 2003 Re pairs BOC22 Type of Repair 21 SG 22 SG 21 SG 22 SG 21 SG 22 SG Tubes Plugged 223 240 7

10 230 250 Tubes Sleeved 0

0 0

0 0

0 Table 1 In accordance with Technical Specification 5.6.7.4, the identification of F* and EF* tubes and the location and extent of degradation are included in Attachment 1 to this letter.

There are 2064 tubes classified as F* tubes and 14 tubes classified as EF* tubes.

In this letter we have made no new Nuclear Regulatory Commission commitments.

Please contact ff 51-388-1121) if you have any questions related to this letter.

os

. Solymossy ice President, Pra e Island Nuclear Generating Plant CC Regional Administrator, USNRC, Region IlIl Project Manager, Prairie Island Nuclear Generating Plant, USNRC, NRR NRC Resident Inspector - Prairie Island Nuclear Generating Plant Attachment 1717 Wakonade Drive East

  • Welch, Minnesota 55089-9642 Telephone: 651.388.1121

\\04'1

ATTACHMENT I NUCLEAR MANAGEMENT COMPANY, LLC PRAIRIE ISLAND NUCLEAR GENERATING PLANT DOCKET 50-306 October 24, 2003 2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 46 pages follow

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT CODES Location (Landmark)

TRH = Top of OEM Hard Roll Hot Leg 1BH = Bottom of Additional Hard Roll 1 2BH = Bottom of Additional Hard Roll 2 EBH = Bottom of Additional Elevated Hard Roll Types of F and EF Stars EF* = EF* Tube with Elevated Additional Roll Expansion F*0 = F* Tube without Additional Roll Expansion F*1 = F* Tube with One Additional Roll Expansion F*2 = F* Tube with Second Higher Additional Roll Expansion Indication Code MAD = Multiple Axial Indication - No Longer Detectable MAI = Multiple Axial Indication MAN = Multiple Axial Indication - No Change SAD = Single Axial Indication - No Longer Detectable SAI = Single Axial Indication SAN = Single Axial Indication - No Change SCN = Single Circumferential Indication - No Change SVN = Single Volumetric Indication - No Change 21 STEAM GENERATOR F*O TUBES. BOC22. 2003 No. SIG-g Row Col Indication Location Elev from Elev to Status 1

21 H

1 2

SAN TRH

-2.26

-2.16 F*O 2

21 H

2 2

SAI TRH

-2.8

-2.73 F*O 3

21 H

1 4

SAN TRH

-2.69

-2.36 F*O 4

21 H

1 5

SAN TRH

-2.81

-2.71 F*0 5

21 H

2 5

SAI TRH

-2.81

-2.71 F*O 6

21 H

1 6

SAN TRH

-2.72

-2.43 F*O 7

21 H

1 7

SAN TRH

-2.83

-2.72 F*O 8

21 H

2 7

MAN TRH

-2.88

-2.48 F*O 9

21 H

4 7

SAI TRH

-2.89

-2.84 F*0 10 21 H

13 7

SAI TRH

-2.82

-2.76 F*O 11 21 H

5 8

SAN TRH

-2.47

-2.35 F*O 12 21 H

24 8

SAI TRH

-2.48

-2.45 F*O 13 21 H

12 9

SAN TRH

-2.56

-2.48 F*O 14 21 H

20 9

MAI TRH

-2.75

-2.63 F*0 15 21 H

25 9

SAN TRH

-2.6

-2.54 F*0 16 21 H

2 10 SAN TRH

-2.37

-2.24 F*O 17 21 H

14 10 SAI TRH

-2.93

-2.82 F*O 18 21 H

15 10 SAN TRH

-2.96

-2.77 F*O 19 21 H

16 10 SAI TRH

-2.83

-2.77 F*O 20 21 H

25 10 SAN TRH

-2.66

-2.57 F*O 21 21 H

26 10 SAN TRH

-2.62

-2.56 F*O 22 21 H

27 10 MAI TRH

-2.7

-2.63 F*O 1

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*O TUBES, BOC22, 2003 No. S/G Leg Row Col Indication Location Elev from Elev to Status 23 21 H

28 10 MAI TRH

-2.83

-2.7 F*O 24 21 H

7 11 SAN TRH

-1.74

-1.59 F*O 25 21 H

19 11 SAI TRH

-2.6

-2.52 F*O 26 21 H

27 11 SAN TRH

-2.4

-2.32 F*O 27 21 H

29 11 MAN TRH

-2.68

-2.52 F*0 28 21 H

5 12 SAN TRH

-2.53

-2.41 F*O 29 21 H

15 12 SAN TRH

-2.8

-2.66 F*O 30 21 H

26 12 SAI TRH

-2.5

-2.47 F*O 31 21 H

27 12 MAI TRH

-2.48

-2.36 F*O 32 21 H

28 12 MAN TRH

-2.53

-2.39 F*O 33 21 H

1 13 MAN TRH

-2.94

-2.76 F*O 34 21 H

6 13 SAN TRH

-2.59

-2.42 F*O 35 21 H

7 13 MAN TRH

-2.68

-2.45 F*O 36 21 H

23 13 SAI TRH

-2.38

-2.34 F*O 37 21 H

25 13 SAI TRH

-2.34

-2.31 F*O 38 21 H

1 14 MAN TRH

-3.03

-2.8 F*O 39 21 H

6 15 SAI TRH

-2.56

-2.51 F*O 40 21 H

7 15 SAN TRH

-2.54

-2.43 F*0 41 21 H

20 15 SAI TRH

-2.49

-2.43 F*0 42 21 H

28 15 MAI TRH

-2.19

-2.16 F*0 43 21 H

2 16 SAN TRH

-2.57

-2.36 F*0 44 21 H

6 16 SAN TRH

-2.45

-2.36 F*0 45 21 H

15 16 SAN TRH

-2.74

-2.59 F*O 46 21 H

16 16 SAI TRH

-2.43

-2.32 F*O 47 21 H

28 16 MAI TRH

-2.67

-2.63 F*O 48 21 H

5 17 MAN TRH

-2.99

-2.89 F*0 49 21 H

7 17 MAN TRH

-2.62

-2.39 F*O 50 21 H

7 18 SAN TRH

-2.53

-2.46 F*O 51 21 H

7 19 MAN TRH

-2.61

-2.42 F*O 52 21 H

26 19 MAN TRH

-2.76

-2.66 F*O 53 21 H

8 20 SAN TRH

-2.54

-2.47 F*O 54 21 H

25 20 MAN TRH

-2.56

-2.38 F*O 55 21 H

31 20 SAN TRH

-2.75

-2.68 F*O 56 21 H

33 20 MAN TRH

-2.63

-2.52 F*O 57 21 H

29 21 SAI TRH

-2.56

-2.5 F*O 58 21 H

32 21 MAN TRH

-2.71

-2.57 F*O 59 21 H

6 22 MAN TRH

-2.4

-2.31 F*O 60 21 H

7 22 SAN TRH

-2.46

-2.33 F*O 61 21 H

7 23 SAN TRH

-2.49

-2.38 F*O 62 21 H

31 24 MAN TRH

-2.59

-2.48 F*0 63 21 H

33 24 SAN TRH

-2.54

-2.43 F*O 64 21 H

1 25 MAN TRH

-2.43

-2.37 F*O 65 21 H

24 25 MAN TRH

-2.47

-2.3 F*O 66 21 H

33 25 SAN TRH

-2.46

-2.37 F*0 67 21 H

33 30 SAN TRH

-2.58

-2.41 F*0 68 21 H

17 32 SAN TRH

-2.64

-2.53 F*O 69 21 H

1 34 SAN TRH

-2.5

-2.4 F*0 2

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*0 TUBES. BOC22. 2003 No. SIG Le Row Col Indication Location Elev from Elev to Status 70 21 H

I 35 SAN TRH

-2.53

-2.44 F*O 71 21 H

1 40 SAI TRH

-2.51

-2.47 F*O 72 21 H

25 41 SAN TRH

-2.42

-2.23 F*O 73 21 H

1 47 MAN TRH

-2.56

-2.17 F*O 74 21 H

21 47 MAN TRH

-2.5

-2.4 F*O 75 21 H

1 58 SAI TRH

-2.44

-2.35 F*O 76 21 H

27 60 MAI TRH

-2.6

-2.5 F*O 77 21 H

28 60 SAN TRH

-2.52

-2.34 F*0 78 21 H

33 60 MAI TRH

-2.77

-2.64 F*O 79 21 H

26 61 SAN TRH _

-2.59

-2.53 F*O 80 21 H

27 61 MAN TRH

-2.44

-2.35 F*O 81 21 H

15 62 SAN TRH

-2.58

-2.43 F*0 82 21 H

23 62 MAN TRH

-2.55

-2.43 F*O 83 21 H

28 62 SAN TRH

-2.45

-2.36 F*0 84 21 H

32 62 SAN TRH

-2.58

-2.45 F*O 85 21 H

33 62 SAN TRH

-2.65

-2.52 F*O 86 21 H

21 63 SAN TRH

-1.86

-1.74 F*O 87 21 H

26 63 SAN TRH

-2.42

-2.38 F*O 88 21 H

27 63 SAN TRH

-2.47

-2.41 F*O 89 21 H

29 63 SAN TRH

-2.7

-2.58 F*O 90 21 H

23 64 SAN TRH

-2.58

-2.46 F*O 91 21 H

25 64 SAI TRH

-2.71

-2.63 F*O 92 21 H

26 64 MAI TRH

-2.46

-2.4 F*O 93 21 H

32 64 MAN TRH

-2.54

-2.41 F*O 94 21 H

33 64 SAN TRH

-2.71

-2.53 F*O 95 21 H

3 65 SAN TRH

-2.77

-2.74 F*O 96 21 H

15 65 SAN TRH

-2.7

-2.64 F*O 97 21 H

23 65 SAN TRH

-2.64

-2.57 F*O 98 21 H

24 65 SAN TRH

-2.63

-2.56 F*O 99 21 H

26 65 MAN TRH

-2.48

-2.3 F-O 100 21 H

30 65 SAN TRH

-2.42

-2.29 F0O 101 21 H

1 66 MAN TRH

-2.61

-2.2 F*O 102 21 H

2 66 SAN TRH

-1.92

-1.87 F*0 103 21 H

23 66 SAI TRH

-2.51

-2.44 F*O 104 21 H

27 66 SAN TRH

-2.42

-2.31 F*O 105 21 H

32 66 SAI TRH

-2.51

-2.39 F*O 106 21 H

17 67 SAN TRH

-1.57

-1.42 F*0 107 21 H

1 68 SAN TRH

-2.41

-2.31 F*O 108 21 H

6 68 SAN TRH

-2.63

-2.51 F*O 109 21 H

8 68 SAN TRH

-2.7

-2.61 F*O 110 21 H

27 68 SAN TRH

-2.49

-2.11 F*O 111 21 H

2 69 SAI TRH

-2.59

-2.48 F*O 112 21 H

24 69 MAN TRH

-2.49

-2.34 F*O 113 21 H

32 69 SAI TRH

-2.76

-2.7 FO 114 21 H

8 70 SAI TRH

-2.61

-2.52 F*O 115 21 H

23 70 MAN TRH

-2.45

-2.38 F*O 116 21 H

24 70 SAN TRH

-2.46

-2.34 F*O 3

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 91 TAM GENERATO)R F*0 TIJBES BOC22-2003 No. S/G Leg Row Col Indication Location Elev from Elev to Status 117 21 H

27 70 SAN TRH

-2.39

-2.26 F*O 118 21 H

30 70 SAN TRH

-2.53

-2.38 F*O 119 21 H

23 71 SAN TRH

-2.46

-2.39 F*O 120 21 H

29 71 SAN TRH

-2.55

-2.41 F*O 121 21 H

27 72 SAN TRH

-2.3

-2.23 F*O 122 21 H

31 72 MAN TRH

-2.43

-2.23 F*O 123 21 H

1 73 SAN TRH

-2.61

-2.55 F*O 124 21 H

25 73 SAN TRH

-2.48

-2.34 F*O 125 21 H

30 74 SAI TRH

-2.47

-2.32 F*O 126 21 H

32 74 SAN TRH

-2.53

-2.38 F*O 127 21 H

1 75 SAN TRH

-2.58

-2.43 F*O 128 21 H

16 75 SAN TRH

-2.71

-2.54 F*O 129 21 H

23 75 SAI TRH

-2.45

-2.31 F*O 130 21 H

27 75 SAI TRH

-2.36

-2.3 F*O 131 21 H

31 75 SAI TRH

-2.29

-2.24 F*O 132 21 H

1 76 SAN TRH

-2.57

-2.42 F*O 133 21 H

6 76 SAN TRH

-2.35

-2.09 F*O 134 21 H

14 76 SAI TRH

-2.31

-2.26 F*O 135 21 H

16 76 SAN TRH

-2.34

-1.88 F*O 136 21 H

21 76 SAN TRH

-2.56

-2.52 F*O 137 21 H

26 76 MAN TRH

-2.43

-2.28 F*O 138 21 H

27 76 MAN TRH

-2.49

-2.34 F*O 139 21 H

29 76 SAI TRH

-2.45

-2.31 F*O 140 21 H

1 77 SAN TRH

-2.55

-2.36 F*O 141 21 H

8 77 SAI TRH

-2.64

-2.47 F*O 142 21 H

27 77 SAI TRH

-2.12

-2.08 F*O 143 21 H

1 78 MAN TRH

-2.56

-2.46 F*O 144 21 H

16 78 SAI TRH

-2.32

-2.27 F*O 145 21 H

17 78 SAI TRH

-2.34

-2.31 F*O 146 21 H

22 78 SAN TRH

-2.34

-2.27 F*0 147 21 H

23 78 SAI TRH

-2.04

-2.02 F*O 148 21 H

27 78 SAI TRH

-2.53

-2.35 F*O 149 21 H

29 78 SAI TRH

-2.5

-2.36 F*O 150 21 H

32 78 MAI TRH

-2.63

-2.52 F*O 151 21 H

14 79 SAN TRH

-2.54

-2.48 F*O 152 21 H

20 79 SAN TRH

-2.53

-2.37 F*O 153 21 H

26 79 MAI TRH

-2.47

-2.34 F*O 154 21 H

25 80 MAN TRH

-2.75

-2.65 F*O 155 21 H

31 80 SAI TRH

-2.61

-2.49 F*O 156 21 H

5 81 SAN TRH

-2.6

-2.41 F*O 157 21 H

25 81 SAN TRH

-2.51

-2.41 F*O 158 21 H

16 82 SAN TRH

-2.18

-2.09 F*O 159 21 H

22 82 SAN TRH

-2.32

-2.25 F*O 160 21 H

23 82 MAI TRH

-2.18

-2.13 F*O 161 21 H

1 83 SAN TRH

-2.57

-2.42 F*O 162 21 H

6 93 SAN TRH

-2.28

-2.21 F*O 4

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS - 15 DAY REPORT 21 STEAM GENERATOR F*1 TUBES, BOC22, 2003 No. S/G Leg Row Co Indication Location Elev from Elev to Status 1

21 H

3 3

SAD IBH

-1.53 0

F*1 2

21 H

14 3

MAD IBH

-1.63 0

F*l 3

21 H

6 4

SAD IBH

-1.16 0

F*l 4

21 H

7 4

SAD IBH

-1 0

F*1 5

21 H

3 5

SAD IBH

-1.58 0

F*1 6

21 H

7 5

MAD 1BH

-1.16 0

F*l 7

21 H

3 6

SAN IBH

-1.61

-1.57 F*1 8

21 H

7 7

SAN IBH

-1.77

-1.71 F*1 9

21 H

17 7

MAD IBH

-1.16 0

F*l 10 21 H

1 8

MAD IBH

-1.31 0

F*1 11 21 H

2 8

SAN IBH

-1.62

-1.58 F*1 12 21 H

13 8

MAD IBH

-1.35 0

F*1 13 21 H

3 9

SAN IBH

-1.63

-1.56 F*l 14 21 H

4 9

MAD IBH

-1.48 0

F 15 21 H

5 9

SAD IBH

-1.37 0

F*1 16 21 H

7 9

MAD IBH

-1.22 0

F*1 17 21 H

11 9

MAD IBH

-1.34 0

F*1 18 21 H

13 9

SAD IBH

-1.27 0

F*1 19 21 H

18 9

MAD 1BH

-1.49 0

F*l 20 21 H

1 10 MAD 1BH

-1.39 0

F*1 21 21 H

4 10 SAD 1BH

-1.39 0

F 22 21 H

5 10 SAD 1BH

-1.1 0

F*l 23 21 H

12 10 SAD 1BH

-1.25 0

F*l 24 21 H

19 10 SAD 1BH

-1.05 0

F*l 25 21 H

20 10 SAD 1BH

-1.33 0

F*l 26 21 H

1 11 SAD IBH

-1.48 0

F*1 27 21 H

2 11 SAD 1BH

-0.9 0

F*l 28 21 H

3 11 SAN 1BH

-1.67

-1.56 F*l 29 21 H

5 11 MAN IBH

-1.23

-1.18 F*l 30 21 H

6 11 SAN IBH

-1.41

-1.37 F*l 31 21 H

10 11 SAD IBH

-1.14 0

F*l 32 21 H

13 11 SAD IBH

-0.78 0

F*l 33 21 H

14 11 MAD IBH

-1.12 0

F*l 34 21 H

15 11 MAD IBH

-1.3 0

F*l 35 21 H

23 11 MAD IBH

-1.5 0

F*l 36 21 H

24 11 MAD IBH

-1.3 0

F*l 37 21 H

1 12 SAD IBH

-1.32 0

F*l 38 21 H

2 12 SAN IBH

-1.49

-1.44 F*l 39 21 H

4 12 SAD IBH

-1.06 0

F*l 40 21 H

7 12 SAD IBH

-1.07 0

F*l 41 21 H

9 12 SAD 1BH

-1.33 0

F*l 42 21 H

11 12 SAD IBH

-1.06 0

F*l 43 21 H

14 12 MAN IBH

-1.22

-1.05 F*l 44 21 H

22 12 SAD 1BH

-1.4 0

F*l 45 21 H

23 12 MAD IBH

-1.43 0

F*1 46 21 H

2 13 MAN IBH

-1.36

-0.96 F*1 47 21 H

4 13 SAN IBH

-1.21

-1.13 F*l 5

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*l TUBES, BOC22,2003 No. S/G Leg Row Col Indication Location Elev from Elev to Status 48 21 H

5 13 SAN IBH

-1.52

-1.44 F*l 49 21 H

8 13 MAD IBH

-1.12 0

F*l 50 21 H

11 13 MAD 1BH

-1.33 0

F*l 51 21 H

13 13 SAD 1BH

-1.4 0

F*l 52 21 H

14 13 SAD 1BH

-1.33 0

F*l 53 21 H

15 13 MAD IBH

-1.19 0

F*l 54 21 H

21 13 SAD IBH

-1.24 0

F*l 55 21 H

2 14 SAI IBH

-1.09

-1.03 F*l 56 21 H

4 14 MAD IBH

-1.22 0

F*1 57 21 H

5 14 SAD IBH

-2.14 0

F*l 58 21 H

7 14 SAN 1

BH

-3.9

-3.81 F*1 59 21 H

9 14 MAD 1BH

-1.35 0

F*l 60 21 H

11 14 MAN 1BH

-1.27

-1.14 F*l 61 21 H

13 14 SAD 1BH

-1.17 0

F*l 62 21 H

15 14 MAD IBH

-1.21 0

F*l 63 21 H

22 14 SAD IBH

-1.17 0

F*l 64 21 H

23 14 SAD IBH

-1.3 0

F*l 65 21 H

1 15 MAN IBH

-1.04

-0.84 F*l 66 21 H

2 15 SAD 1BH

-1.38 0

F*l 67 21 H

4 15 MAD IBH

-1.02 0

F*1 68 21 H

5 15 SAD 1BH

-1.17 0

F*l 69 21 H

8 15 SAD IBH

-1.21 0

F*l 70 21 H

10 15 SAD 1BH

-1.37 0

F*l 71 21 H

11 15 SAD IBH

-0.89 0

F*l 72 21 H

13 15 MAN 1BH

-1.32

-0.92 F*l 73 21 H

14 15 SAD 1BH

-1.26 0

F*l 74 21 H

15 15 SAD 1BH

-0.9 0

F*l 75 21 H

16 15 MAN 1BH _

-1.25

-1.15 F*l 76 21 H

18 15 MAN 1BH _

-1.23

-1.14 F*l 77 21 H

19 15 MAD IBH

-1.21 0

F 78 21 H

22 15 SAD IBH

-1.22 0

F*l 79 21 H

23 15 SAD 1BH

-1.18 0

F*l 80 21 H

26 15 SAD 1BH

-0.85 0

F*l 81 21 H

27 15 SAD IBH

-1.31 0

F*l 82 21 H

1 16 SAD 1BH

-1.34 0

F*l 83 21 H

3 16 SAD 1BH

-1.16 0

F*l 84 21 H

4 16 MAN 1BH

-1.27

-1.15 F*l 85 21 H

5 16 SAN 1BH

-1.29

-1.1 F*l 86 21 H

7 16 SAD IBH

-0.8 0

F*l 87 21 H

8 16 MAD IBH

-1.2 0

F*l 88 21 H

10 16 SAD 1BH

-0.88 0

F*l 89 21 H

12 16 MAD IBH

-1.23 0

F*l 90 21 H

13 16 MAD IBH

-1.16 0

F*1 91 21 H

14 16 MAD IBH

-1.35 0

F*l 92 21 H

17 16 SAD IBH

-1.28 0

F*1 93 21 H

18 16 SAD IBH

-1.24 0

F*l 94 21 H

24 16 MAD IBH

-1.39 0

F*l 6

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT

'14 TCAA r-10KICAT(ID =*I T1IQ=Q

.f9)nnAl 1r_

mvlcmzovr I

VJC I

, DUI VI %.L119.

VV W

II No. S/G Leg Row Cot Indication Location Elev from Elev to Status 95 21 H

26 16 MAD 1BH

-1.4 0

F*1 96 21 H

29 16 MAN 1BH

-1.16

-1.09 F*l 97 21 H

1 17 MAN 1BH

-1.17

-0.88 F*l 98 21 H

2 17 SAD 1BH

-1.4 0

F*l 99 21 H

6 17 SAD 1BH

-0.92 0

F*1 100 21 H

10 17 SAD 1BH

-1.37 0

F*1 101 21 H

11 17 SAD 1BH

-1.32 0

F*l 102 21 H

13 17 SAD I1BH

-1.31 0

F*l 103 21 H

19 17 SAD 1BH

-1.32 0

F*l 104 21 H

22 17 SAD 1BH

-1.35 0

F*l 105 21 H

25 17 SAN 1BH

-1.06

-0.94 F*1 106 21 H

1 18 MAD 1BH

-1.21 0

F*1 107 21 H

2 18 SAD 1BH

-0.89 0

F*1 108 21 H

3 18 SAN 1BH

-1.06

-0.95 F*l 109 21 H

4 18 MAN 1BH

-1.37

-1.14 F*l 110 21 H

5 18 MAN 1BH

-1.05

-0.85 F*l 111 21 H

10 18 MAD 1BH

-1.25 0

F*l 112 21 H

11 18 SAD 1BH

-1.4 0

F*l 113 21 H

13 18 SAD 1BH

-1.3 0

F*l 114 21 H

16 18 SAD 1BH

-1.44 0

F*l 115 21 H

18 18 MAD 1BH

-0.82 0

F*1 116 21 H

20 18 SAD 1BH

-0.85 0

F*1 117 21 H

22 18 SAD 1BH

-1.15 0

F*l 118 21 H

25 18 SAD 1BH

-2.11 0

F*l 119 21 H

31 18 SAD 1BH_

-1.22 0

F*l 120 21 H

33 18 SAN 1BH_

-1.04

-1.01 F*l 121 21 H

1 19 MAN 1BH

-1.16

-0.82 F*l 122 21 H

2 19 SAD 1BH

-1.39 0

F*l 123 21 H

4 19 SAD 1BH

-1.2 0

F*l 124 21 H

8 19 SAD 1BH

-1.32 0

F*l 125 21 H

9 19 MAD 1BH

-1.2 0

F*l 126 21 H

11 19 MAD 1BH

-1.37 0

F*l 127 21 H

12 19 MAD 1BH

-1.2 0

F*l 128 21 H

14 19 SAD 1BH

-0.85 0

F*1 129 21 H

15 19 SAN 1BH

-1.14

-1.08 F*l 130 21 H

16 19 SAD 1BH

-1.2 0

F*l 131 21 H

17 19 MAD 1BH

-0.86 0

F*l 132 21 H

19 19 MAN 1BH

-1.13

-1.04 F*l 133 21 H

20 19 SAD 1BH

-1.21 0

F*l 134 21 H

22 19 MAD 1BH

-0.93 0

F*l 135 21 H

23 19 SAD 1BH

-1.06 0

F*l 136 21 H

24 19 SAD 1BH

-0.9 0

F*1 137 21 H

25 19 MAD 1BH

-1.25 0

F*l 138 21 H

27 19 MAD 1BH

-1.1 0

F*l 139 21 H

30 19 SAD 1BH

-1.37 0

F*l 140 21 H

31 19 MAD 1BH

-1.3 0

F*l 141 21 H

32 19 SAD 1BH

-1.42 0

F*l 7

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*1 TUBES. BOC22. 2003 No. SIG Leg Row Col Indication Location Elev from Elev to Status 142 21 H

33 19 SAD IBH

-1.38 0

F*l 143 21 H

4 20 SAD 1BH

-0.95 0

F*1 144 21 H

6 20 SAD IBH

-0.9 0

F*l 145 21 H

7 20 MAN IBH

-1.25

-1.1 F*l 146 21 H

9 20 SAD 1BH

-1.16 0

F*1 147 21 H

11 20 SAD 1BH

-1.06 0

F*1 148 21 H

13 20 MAN 1BH

-1.23

-1.04 F*1 149 21 H

16 20 SAD 1BH_

-1.2 0

F*1 150 21 H

17 20 MAN 1BH

-1.2

-1.11 F*1 151 21 H

18 20 SAD 1BH

-1.29 0

F*1 152 21 H

19 20 SAD IBH

-1.4 0

F*1 153 21 H

20 20 SAD IBH

-1.23 0

F*1 154 21 H

23 20 MAD IBH

-1.42 0

F*1 155 21 H

29 20 MAN 1BH

-1.14

-0.97 F*1 156 21 H

30 20 SAD 1BH

-1.4 0

F*1 157 21 H

34 20 SAD 1BH

-1.34 0

F*1 158 21 H

35 20 SAD IBH

-1.27 0

F*l 159 21 H

36 20 MAD IBH

-1.37 0

F*l 160 21 H

37 20 MAD IBH

-1.35 0

F*l 161 21 H

6 21 MAN IBH

-1.17

-1.1 F*l 162 21 H

8 21 SAD IBH

-1.15 0

F*l 163 21 H

11 21 SAD IBH

-1.21 0

F*l 164 21 H

12 21 MAD 1BH

-1.27 0

F*l 165 21 H

14 21 MAN 1BH_

-0.56

-0.21 F*l 166 21 H

16 21 MAN 1BH

-1.18

-1.12 F*l 167 21 H

17 21 MAN 1BH

-1.16

-1.07 F*l 168 21 H

20 21 MAD 1BH

-0.88 0

F*l 169 21 H

23 21 MAD IBH

-1.41 0

F*l 170 21 H

24 21 MAN IBH

-1.12

-0.94 F*l 171 21 H

26 21 SAD IBH

-1.25 0

F*l 172 21 H

27 21 SAD IBH

-1.47 0

F*l 173 21 H

28 21 SAD IBH

-0.85 0

F*l 174 21 H

30 21 SAD 1BH

-1.4 0

F*l 175 21 H

31 21 SAD 1BH

-1.27 0

F*l 176 21 H

33 21 SAD 1BH

-1.26 0

F*l 177 21 H

36 21 SAD IBH

-1.25 0

F*1 178 21 H

1 22 MAN IBH

-1.11

-0.99 F*l 179 21 H

2 22 MAN 1BH

-1.27

-1.13 F*l 180 21 H

4 22 MAN IBH

-1.26

-1.16 F*l 181 21 H

5 22 SAD IBH

-0.84 0

F*1 182 21 H

8 22 MAN 1BH

-1.26

-1.12 F*l 183 21 H

9 22 SAD 1BH

-1.16 0

F*l 184 21 H

10 22 SAD 1BH

-0.9 0

F*l 185 21 H

13 22 MAD IBH

-1.2 0

F*l 186 21 H

14 22 MAN 1BH

-1.21

-1.11 F*1 187 21 H

17 22 MAN 1BH

-1.13

-1.02 F*1 188 21 H

18 22 SAD IBH

-1.16 0

F*l 8

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*i TUBES. BOC22. 2003 No. SIG Leg Row Col Indication Location Elev from Elev to Status 189 21 H

19 22 MAD 1BH

-1.2 0

F*1 190 21 H

20 22 SAD 1BH

-0.88 0

F*1 191 21 H

21 22 MAD IBH

-1.31 0

F*1 192 21 H

24 22 MAD IBH

-0.85 0

F*1 193 21 H

26 22 MAD 1BH

-0.87 0

F*1 194 21 H

28 22 SAD IBH

-1.28 0

F*1 195 21 H

32 22 SAD IBH

-1.39 0

F*1 196 21 H

37 22 MAD IBH

-1.49 0

F*1 197 21 H

1 23 MAD IBH

-1 0

F*1 198 21 H

3 23 MAN IBH

-1.17

-0.89 F*l 199 21 H

5 23 MAD IBH

-1.4 0

F*l 200 21 H

6 23 MAN IBH

-1.19

-1.08 F*1 201 21 H

8 23 MAD IBH

-1.3 0

F*l 202 21 H

9 23 MAN IBH

-0.44

-0.25 F*l 203 21 H

10 23 SAD IBH

-0.87 0

F*1 204 21 H

12 23 MAD IBH

-1.21 0

F*1 205 21 H

14 23 MAN 1BH

-1.2

-1.05 F*l 206 21 H

16 23 MAN IBH

-1.22

-1.11 F*l 207 21 H

17 23 MAD IBH

-1.3 0

F*1 208 21 H

19 23 MAN 1BH

-1.18

-1.07 F*l 209 21 H

23 23 MAD 1BH

-1.22 0

F*l 210 21 H

24 23 MAD 1BH

-0.83 0

F*1 211 21 H

25 23 MAD 1BH

-0.78 0

F*l 212 21 H

27 23 SAD 1BH

-1.17 0

F*1 213 21 H

30 23 MAD 1BH

-0.97 0

F*l 214 21 H

31 23 SAD 1BH

-1.23 0

F*l 215 21 H

34 23 SAD 1BH

-1.17 0

F*l 216 21 H

37 23 SAD 1BH

-1.38 0

F*l 217 21 H

38 23 MAD IBH

-1.29 0

F*l 218 21 H

39 23 MAD IBH

-1.38 0

F*1 219 21 H

2 24 SAD IBH

-1.35 0

F*1 220 21 H

4 24 MAD IBH

-1.23 0

F*l 221 21 H

5 24 MAN IBH

-1.28

-1.11 F*l 222 21 H

7 24 SAD 1BH

-1.32 0

F*l 223 21 H

8 24 SAD 1BH

-1.26 0

F*l 224 21 H

9 24 SAN 1BH

-1.14

-1.04 F*l 225 21 H

11 24 MAD 1BH

-1.16 0

F*l 226 21 H

12 24 MAN IBH

-1.24

-1.12 F*l 227 21 H

15 24 SAD 1BH

-0.89 0

F*l 228 21 H

16 24 MAD 1BH

-1.2 0

F*1 229 21 H

19 24 MAD 1BH

-0.82 0

F*1 230 21 H

20 24 MAD IBH

-1.34 0

F*1 231 21 H

25 24 SAD IBH

-1.25 0

F*1 232 21 H

28 24 SAD IBH

-0.93 0

F*1 233 21 H

29 24 SAD 1BH

-1.14 0

F1 234 21 H

30 24 MAD 1BH

-1.31 0

F*l 235 21 H

35 24 SAD 1BH

-0.83 0

F*l 9

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS - 15 DAY REPORT 21 STEAM GENERATOR F*1 TUBES, BOC22, 2003 No. SIG Leg Row Col Indication Location Elev from Elev to Status 236 21 H

37 24 SAD IBH

-1.32 0

F*l 237 21 H

5 25 SAD 1BH

-1.17 0

F*l 238 21 H

6 25 MAD 1BH

-1.2 0

F*l 239 21 H

7 25 SAD 1BH

-1.3 0

F*l 240 21 H

8 25 SAD 1BH

-1.49 0

F*l 241 21 H

9 25 SAD 1BH

-0.82 0

F*l 242 21 H

10 25 SAD IBH

-1.29 0

F*l 243 21 H

14 25 MAD IBH

-1.29 0

F*1 244 21 H

16 25 SAN IBH

-1.22

-1.12 F*l 245 21 H

17 25 SAD 1BH

-1.21 0

F*1 246 21 H

20 25 MAD 1

BH

-1.26 0

F*l 247 21 H

23 25 SAD 1BH

-1.21 0

F*l 248 21 H

25 25 MAD IBH

-1.25 0

F*l 249 21 H

28 25 SAD IBH

-1.06 0

F*1 250 21 H

30 25 MAD IBH

-1.39 0

F*1 251 21 H

38 25 MAD IBH

-0.89 0

F*l 252 21 H

1 26 SAD IBH

-0.95 0

F*l 253 21 H

5 26 SAD IBH

-1.27 0

F*l 254 21 H

7 26 MAD IBH

-1.32 0

F*l 255 21 H

8 26 SAD IBH

-1.25 0

F*l 256 21 H

10 26 MAD IBH

-0.91 0

F*l 257 21 H

13 26 MAD 1BH

-1.27 0

F*l 258 21 H

15 26 MAD 1BH

-0.85 0

F*l 259 21 H

16 26 SAD 1BH

-1.26 0

F*l 260 21 H

17 26 SAN 1BH

-0.99

-0.93 F*l 261 21 H

19 26 MAD 1BH

-1.27 0

F*l 262 21 H

22 26 SAD IBH

-1.22 0

F*l 263 21 H

25 26 SAD IBH

-1.13 0

F*l 264 21 H

28 26 SAD IBH

-0.93 0

F*l 265 21 H

34 26 SAD 1BH

-1.1 0

F*1 266 21 H

2 27 SAD 1BH

-1.2 0

F*l 267 21 H

3 27 SAD 1BH

-1.46 0

F*l 268 21 H

4 27 MAN 1BH

-0.72

-0.29 F*l 269 21 H

5 27 SAN IBH

-1.68

-1.51 F

270 21 H

6 27 SAD IBH

-0.87 0

F*l 271 21 H

8 27 SAN IBH

-1.09

-1.01 F*l 272 21 H

9 27 SAD IBH

-1.23 0

F*l 273 21 H

13 27 SAD 1BH

-1.28 0

F*l 274 21 H

16 27 SAD IBH

-1.21 0

F*l 275 21 H

17 27 MAN IBH

-1.34

-0.98 F*l 276 21 H

18 27 SAD 1BH

-1.33 0

F*l 277 21 H

26 27 MAD 1BH

-1.27 0

F*l 278 21 H

27 27 MAD IBH

-1.3 0

F*l 279 21 H

31 27 MAD IBH

-0.79 0

F*l 280 21 H

32 27 SAN 1BH

-1.14

-1 F1 281 21 H

35 27 SAD 1BH

-1.06 0

F*l 282 21 H

36 27 MAD 1BH

-1.18 0

F*l 10

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 91 TEAM GENFRATOR F*1 TURES. ROC22 23'A No. SIG q Row Col Indication Location Elev from Elev to Status 283 21 H

37 27 MAD 1BH

-0.9 0

F*l 284 21 H

1 28 MAN IBH

-1.17

-0.96 F*l 285 21 H

3 28 MAN 1BH

-1.24

-1.11 F*l 286 21 H

5 28 MAN 1BH

-1.21

-1.09 F*l 287 21 H

6 28 SAD 1BH

-1.3 0

F*l 288 21 H

7 28 MAD 1BH

-1.17 0

F*l 289 21 H

8 28 SAD 1BH

-1.2 0

F*l 290 21 H

10 28 SAN 1BH

-1.36

-1.25 F*1 291 21 H

11 28 SAD 1BH

-0.77 0

F*l 292 21 H

15 28 SAN 1BH

-1.19

-1.13 F*l 293 21 H

16 281 MAN IBH

-1.28

-1.11 F*l 294 21 H

17 28 MAD IBH

-1.17 0

F*l 295 21 H

18 28 MAD 1BH

-1.23 0

F*1 296 21 H

19 28 MAN 1BH

-1.29

-0.85 F*l 297 21 H

20 28 SAD 1BH

-1.25 0

F*l 298 21 H

21 28 MAN 1BH

-1.36

-0.97 F*l 299 21 H

23 28 MAN IBH

-1.31

-0.94 F*l 300 21 H

28 28 SAD 1BH

-1.18 0

F*l 301 21 H

30 28 SAD IBH

-1.15 0

F*l 302 21 H

31 28 MAD 1BH

-1.19 0

F*l 303 21 H

32 28 SAD IBH

-0.96 0

F*1 304 21 H

39 28 SAD 1BH

-1.32 0

F*1 305 21 H

5 29 SAD IBH

-0.89 0

F*l 306 21 H

7 29 MAN 1BH

-1.11

-0.98 F*1 307 21 H

8 29 MAD 1BH

-1.27 0

F*l 308 21 H

9 29 SAD 1BH

-0.9 0

F*l 309 21 H

10 29 MAD 11BH

-1.31 0

F*l 310 21 H

16 29 MAN 1BH

-1.03

-0.82 F*l 311 21 H

18 29 MAN 1BH

-1.38

-0.95 F*l 312 21 H

19 29 MAD 1BH

-1.3 0

F*l 313 21 H

22 29 MAD 1BH_

-1.09 0

F*l 314 21 H

23 29 MAD IBH

-1.26 0

F*l 315 21 H

25 29 SAD IBH

-1.26 0

F*l 316 21 H

26 29 SAD 1BH

-1.22 0

F*l 317 21 H

27 29 MAD 1BH

-1.27 0

F*l 318 21 H

28 29 MAD 1BH

-1.16 0

F*l 319 21 H

31 29 MAD IBH

-1.29 0

F*l 320 21 H

35 29 SAD IBH

-0.86 0

F*1 321 21 H

1 30 MAD 1BH

-1.42 0

F*l 322 21 H

3 30 MAD IBH

-1.26 0

F*l 323 21 H

4 30 MAN 1BH

_ -0.49

-0.32 F*l 324 21 H

6 30 MAN 1BH

-1.34

-0.98 F*1 325 21 H

8 30 SAN 1BH

-1.26

-1.15 F*1 326 21 H

10 30 SAD 1BH

-1.12 0

F1 327 21 H

21 30 MAD 1BH

-1.25 0

F*1 328 21 H

22 30 MAD 1BH

-1.2 0

F*l 329 21 H

26 30 SAD 1BH

-0.79 0

F*l 11

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*1 TUBES, BOC22,2003 No. SIG Leg Row Col Indication Location Elev from Elev to Status 330 21 H

29 30 MAD 1BH

-0.88 0

F*l 331 21 H

31 30 MAD IBH

-1.38 0

F*l 332 21 H

38 30 SAD IBH

-1.13 0

F*l 333 21 H

1 31 SAD 1BH

-1.21 0

F*l 334 21 H

2 31 MAD 1BH

-1 0

F*l 335 21 H

3 31 MAN 1BH

-1.08

-1.02 F*l 336 21 H

4 31 MAN IBH

-1.35

-0.94 F*1 337 21 H

5 31 SAD IBH

-1.08 0

F*l 338 21 H

6 31 SAN 1BH

-1.05

-0.81 F*l 339 21 H

7 31 MAD IBH

-1.41 0

F*l 340 21 H

10 31 SAD IBH

-1.26 0

F*1 341 21 H

22 31 SAD IBH

-1.27 0

F*l 342 21 H

26 31 SAD IBH

-0.84 0

F*1 343 21 H

27 31 SAD IBH

-1.29 0

F*l 344 21 H

32 31 SAD IBH

-1.36 0

F*1 345 21 H

34 31 MAD IBH

-0.82 0

F*l 346 21 H

35 31 SAD 1BH

-0.9 0

F*1 347 21 H

37 31 MAD 1BH

-1.23 0

F*l 348 21 H

1 32 MAN IBH

-1.31

-1.13 F*l 349 21 H

3 32 MAD 1BH

-1.5 0

F*l 350 21 H

5 32 SAD 1BH

-1.45 0

F*1 351 21 H

6 32 MAN 1BH

-1.47

-0.98 F*l 352 21 H

7 32 MAD IBH

-1.07

-1.02 F*1 353 21 H

8 32 SAD 1BH H

-0.97 0

F*l 354 21 H

24 32 MAD IBH

-1.29 0

F*l 355 21 H

25 32 SAD 1BH H

-1.26 0

F*1 356 21 H

26 32 SAD 1BH H

-1.18 0

F*l 357 21 H

27 32 SAD IBH

-1.27 0

F*l 358 21 H

30 32 SAN 1BH

-1.27

-1.1 F*l 359 21 H

32 32 MAN 1BH

-1.18

-1.1 F*l 360 21 H

33 32 SAD 1B8H

-1.26 0

F*l 361 21 H

36 32 MAD 1BH

-0.9 0

F*l 362 21 H

3 33 MAN 1BH

-1.29

-1.09 F*l 363 21 H

4 33 SAD 1BH

-1.3 0

F*l 364 21 H

7 33 MAN 1BH

-1.2

-1.1 F*l 365 21 H

8 33 MAN IBH

-1.2

-1.04 F*1 366 21 H

11 33 SAD IBH

-1.24 0

F*1 367 21 H

21 33 MAN IBH

-1.2

-1.06 F*l 368 21 H

22 33 SAD IBH

-1.27 0

F*1 369 21 H

23 33 SAD 1B8H

-0.88 0

F*l 370 21 H

24 33 SAD 1B8K

-1.31 0

F*l 371 21 H

27 33 MAN 1B8K

-1.25

-1.12 F*1 372 21 H

33 33 MAD 1BH

-1.26 0

F*l 373 21 H

37 33 MAD 1BH

-1.38 0

F*l 374 21 H

2 34 SAD 1B8H

-1.24 0

F*l 375 21 H

3 34 SAN 1BH

-0.95

-0.81 F*1 376 21 H

4 34 SAD 1BH

-1.14 0

F*l 12

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F1 TUBES, BOC22, 2003 No. SIG _ Row Col Indication Location Elev from Elev to Status 377 21 H

7 34 SAD IBH

-1.42 0

F*1 378 21 H

8 34 MAN IBH

-1.18

-1.03 F*1 379 21 H

10 34 MAN IBH

-1.24

-0.96 F*1 380 21 H

27 34 SAD IBH

-0.87 0

F*1 381 21 H

28 34 SAD IBH

-0.88 0

F*1 382 21 H

29 34 MAD 1BH

-1.22 0

F*1 383 21 H

33 34 SAD IBH

-1.26 0

F*1 384 21 H

34 34 MAN IBH

-1.28

-1.13 F

385 21 H

36 34 SAD IBH

-0.98 0

F*1 386 21 H

37 34 MAD 1BH

-1.38 0

F*1 387 21 H

41 34 MAD IBH

-1.22 0

F 388 21 H

2 35 SAN IBH

-1.28

-1.21 F

389 21 H

4 35 MAD 1BH

-0.95 0

F 390 21 H

5 35 MAD 1BH

-1.18 0

F 391 21 H

8 35 MAN IBH

-1.18

-1.06 F*l 392 21 H

11 35 SAD IBH

-1.28 0

F*l 393 21 H

12 35 SAD 1BH

-1.29 0

F 394 21 H

13 35 MAN 1BH

-1.14

-1.08 F*1 395 21 H

21 35 MAD 1BH

-1.21 0

F 396 21 H

24 35 SAD IBH

-1.25 0

F 397 21 H

27 35 MAD IBH

-1.2 0

F 398 21 H

29 35 SAD IBH

-1.29 0

F 399 21 H

30 35 SAD IBH

-1.31 0

F*l 400 21 H

31 35 SAD IBH

-1.36 0

F 401 21 H

37 35 SAD IBH

-1.45 0

F*l 402 21 H

3 36 SAD IBH

-1.3 0

F*l 403 21 H

4 36 MAD IBH

-1.27 0

F*l 404 21 H

6 36 MAN 1BH

-1.22

-1.04 F*l 405 21 H

9 36 SAD 1BH

-1.42 0

F*1 406 21 H

10 36 SAD 1BH

-1.35 0

F*1 407 21 H

12 36 SAD IBH

-1.55 0

F*l 408 21 H

20 36 MAN 1BH

-1.16

-1.01 F*1 409 21 H

22 36 SAN IBH

-1.18

-1.05 F*l 410 21 H

23 36 MAD IBH

-1.3 0

F*l 411 21 H

25 36 SAD IBH

-1.4 0

F*l 412 21 H

27 36 SAD 1BH

-1.26 0

F*l 413 21 H

29 36 SAD 1BH

-1.31 0

F 414 21 H

35 36 MAD 1BH

-0.86 0

F 415 21 H

36 36 SAD IBH

-0.9 0

F 416 21 H

38 36 MAD 1BH

-1.22 0

F 417 21 H

4 37 SAD 1BH

-1.33 0

F 418 21 H

6 37 MAN 1BH

-1.13

-1 F

419 21 H

8 37 MAN 1BH

-0.94

-0.85 Fl 420 21 H

9 37 SAD IBH

-0.9 0

F*l 421 21 H

10 37 SAD IBH

-0.9 0

F*l 422 21 H

13 37 MAN IBH

-1.16

-1.03 F*1 423 21 H

21 37 SAN IBH

-1.12

-0.98 F1 13

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS - 15 DAY REPORT 21 STEAM GENERATOR F*l TUBES, BOC22, 2003 No. S/G Leg Row Col Indication Location Elev from Elev to Status 424 21 H

22 37 SAD 1BH

-0.8 0

F*l 425 21 H

25 37 SAD 1BH

-1.2 0

F*1 426 21 H

27 37 MAD IBH

-1.25 0

F*l 427 21 H

28 37 MAD 1BH

-0.84 0

F*l 428 21 H

32 37 SAD IBH

-1.2 0

F*l 429 21 H

33 37 SAD IBH

-0.88 0

F*l 430 21 H

34 37 SAD IBH

-1.24 0

F*l 431 21 H

36 37 MAD IBH

-1.27 0

F*l 432 21 H

1 38 MAD IBH

-1.25 0

F*l 433 21 H

3 38 MAN IBH

-1.13

-1 F*l 434 21 H

5 38 SAD IBH

-1.35 0

F*l 435 21 H

7 38 MAN 1BH __

-1.16

-1.06 F*l 436 21 H

8 38 MAD 1BH

-0.93 0

F*l 437 21 H

9 38 MAN 1BH

-1.22

-1.04 F*l 438 21 H

12 38 SAD 1BH _

-1.5 0

F*1 439 21 H

13 38 SAN 11BH

-1.15

-1 F*l 440 21 H

23 38 MAD IBH

-0.91 0

F*l 441 21 H

24 38 SAD 1BH

-1.18 0

F*l 442 21 H

30 38 MAD IBH

-1.11 0

F*l 443 21 H

31 38 SAD 1BH

-1.25 0

F*1 444 21 H

32 38 SAD 1BH

-1.4 0

F*l 445 21 H

35 38 MAD 1BH

-1.26 0

F*l 446 21 H

37 38 MAD 1BH

-1.22 0

F*l 447 21 H

2 39 SAD 1BH

-1.36 0

F*l 448 21 H

4 39 MAN 1BH

-1.33

-0.93 F*l 449 21 H

7 39 SAD 1BH

-1.35 0

F*l 450 21 H

9 39 SAD 1BH

-1.24 0

F*1 451 21 H

12 39 SAN 1BH

-1.13

-1.02 F*l 452 21 H

15 39 SAD 1BH

-0.91 0

F*l 453 21 H

19 39 SAD 1BH

-1.29 0

F*1 454 21 H

20 39 SAN 1BH

-1.27

-1.14 F*l 455 21 H

21 39 SAN 1BH

-1.2

-1.11 F*1 456 21 H

22 39 SAD 1BH

-1.28 0

F*l 457 21 H

24 39 SAD 1BH

-1.13 0

F*l 458 21 H

25 39 MAN 1BH

-1.17

-1.06 F*l 459 21 H

26 39 SAD 1BH

-1.22 0

F*l 460 21 H

30 39 MAD 1BH

-1.17 0

F*l 461 21 H

32 39 MAD 1BH

-1.23 0

F*1 462 21 H

33 39 SAD IBH

-1.19 0

F*l 463 21 H

35 39 SAD 1

BH

-1.13 0

F*l 464 21 H

36 39 SAD 1BH

-1.43 0

F*l 465 21 H

2 40 SAD 1BH

-1.36 0

F 466 21 H

3 40 MAD IBH

-1.26 0

F*1 467 21 H

6 40 MAD IBH

-1.3 0

F*1 468 21 H

9 40 SAD 1BH

-1.27 0

F*1 469 21 H

10 40 MAN 1BH

-1.26

-1.15 F*1 470 21 H

12 40 MAD 1BH

-1.3 0

F*l 14

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*1 TUBES, BOC22, 2003 No. S/G Leg Row Col Indication Location Elev from Elev to Status 471 21 H

13 40 MAD IBH

-1.56 0

F*1 472 21 H

21 40 MAD IBH

-1.26 0

F*1 473 21 H

26 40 MAD 1BH

-1.28 0

F*1 474 21 H

29 40 SAD 11BH

-1.3 0

F*l 475 21 H

30 40 SAD 1BH

-0.8 0

F*l 476 21 H

32 40 MAD IBH

-1.23 0

F*1 477 21 H

33 40 SAD IBH

-1.2 0

F*l 478 21 H

37 40 MAD 1BH

-1.14 0

F*l 479 21 H

1 41 SAD 1BH

-1.3 0

F*l 480 21 H

2 41 SAD IBH

-0.93 0

F*l 481 21 H

3 41 SAD IBH

-1.31 0

F*l 482 21 H

4 41 MAN IBH

-1.35

-0.91 F*l 483 21 H

5 41 MAN IBH

-0.99

-0.9 F*1 484 21 H

7 41 MAN IBH

-1.15

-1.06 F*l 485 21 H

8 41 MAD IBH

-1.27 0

F*l 486 21 H

11 41 SAD 1BH

-1.37 0

Fl 487 21 H

12 41 MAN IBH

-1.19

-1.06 F*l 488 21 H

14 41 MAN IBH

-0.88

-0.1 F*l 489 21 H

23 41 SAD IBH

-0.98 0

F*1 490 21 H

28 41 SAD IBH

-1.29 0

F*1 491 21 H

1 42 SAD IBH

-1.36 0

F*1 492 21 H

3 42 MAD 1BH

-1.22 0

F*l 493 21 H

4 42 SAD 1BH

-1.3 0

F*1 494 21 H

5 42 MAD 1BH

-0.92 0

F*l 495 21 H

8 42 MAD IBH

-1.23 0

F*l 496 21 H

10 42 SAD IBH

-1.28 0

F*l 497 21 H

12 42 MAD IBH

-1.17 0

F*1 498 21 H

15 42 MAN IBH

-1.11

-1.02 F*1 499 21 H

16 42 SAD IBH

-1.31 0

F*l 500 21 H

17 42 SAD IBH

-0.8 0

F*1 501 21 H

20 42 SAD IBH

-1.3 0

F*l 502 21 H

21 42 SAN IBH

-0.42

-0.26 F*l 503 21 H

24 42 SAD 1BH

-1.25 0

F*l 504 21 H

25 42 SAD 1BH

-0.85 0

F*l 505 21 H

28 42 SAD IBH

-1.05 0

F*1 506 21 H

36 42 MAD IBH

-1.37 0

F*l 507 21 H

5 43 SAN IBH

-1.24

-1.18 F*l 508 21 H

7 43 MAN IBH

-1.21

-1.09 F*l 509 21 H

8 43 SAN IBH

-1.28

-1.15 F*l 510 21 H

9 43 MAN IBH

-1.28

-1.05 F*l 511 21 H

12 43 SAN 1BH

-0.93

-0.89 F*l 512 21 H

21 43 SAD 1BH

-1.23 0

F*1 513 21 H

23 43 MAN 1BH

-1.24

-1.08 F*l 514 21 H

24 43 MAN IBH

-1.5

-0.82 F*l 515 21 H

30 43 SAD 1BH

-0.8 0

F*l 516 21 H

32 43 SAD 1BH

-1.1 0

F*l 517 21 H

35 43 SAD I BH

-1.18 0

F*1 15

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*l TUBES. BOC22. 2003 No. SIG Leg Row Col Indication Location Elev from Elev to Status 518 21 H

1 44 MAD 1BH

-1.32 0

F*l 519 21 H

3 44 SAD 1BH

-1.3 0

F*l 520 21 H

4 44 MAD 1BH

-1.25 0

F*l 521 21 H

6 44 SAD 1BH

-1.3 0

F*l 522 21 H

8 44 SAD 1BH

-0.9 0

F*l 523 21 H

12 44 MAD 1BH

-0.95 0

F*l 524 21 H

13 44 SAD 1BH

-0.93 0

F*l 525 21 H

21 44 SAD 1BH

-1.3 0

F*l 526 21 H

22 44 SAD 1BH

-0.9 0

F*l 527 21 H

24 44 MAN 1BH

-1.34

-1.08 F*l 528 21 H

1 45 SAD 1BH

-1.36 0

F*l 529 21 H

3 45 MAN 1BH

-1.34

-0.83 F*l 530 21 H

6 45 SAD 1BH

-1.18 0

F*1 531 21 H

9 45 MAN 1BH

-1.06

-0.82 F*l 532 21 H

10 45 MAD 1BH

-0.89 0

F*l 533 21 H

13 45 MAN 1BH

-1.34

-0.75 F*l 534 21 H

14 45 SAN 1BH

-0.88

-0.82 F*l 535 21 H

16 45 SAD 1BH

-1.3 0

F*l 536 21 H

18 45 MAD 1BH

-1.23 0

F*l 537 21 H

21 45 MAD 1BH

-1.22 0

F*l 538 21 H

23 45 SAD 1BH

-1.33 0

F*1 539 21 H

32 45 MAD 1BH

-1.26 0

F*l 540 21 H

34 45 SAD IBH

-1.07 0

F*l 541 21 H

4 46 MAN 1BH

-1.26

-1.17 F*l 542 21 H

5 46 SAD 1BH

-1.35 0

F*l 543 21 H

6 46 MAD 1BH

-1.55 0

F*l 544 21 H

7 46 SAD IBH

-1.43 0

F*l 545 21 H

8 46 MAN IBH

-1.32

-1.13 F*l 546 21 H

10 46 MAD 1BH

-1.49 0

F*l 547 21 H

14 46 MAN IBH

-1.09

-0.86 F*1 548 21 H

15 46 SAD IBH

-0.93 0

F*l 549 21 H

16 46 MAD 1BH

-1.36 0

F*1 550 21 H

17 46 SAD IBH

-1.25 0

F*l 551 21 H

18 46 SAD IBH

-1.24 0

F*l 552 21 H

19 46 SAD IBH

-1.18 0

F*l 553 21 H

21 46 SAD 1BH

-1.25 0

F*l 554 21 H

22 46 MAN 1BH

-0.34

-0.04 F*l 555 21 H

24 46 MAN 1BH

-0.7

-0.13 F*l 556 21 H

27 46 SAD 1BH

-0.85 0

F*l 557 21 H

28 46 MAD 1BH

-1.28 0

F*l 558 21 H

34 46 MAD 1BH

-1.27 0

F*l 559 21 H

3 47 MAD IBH

-1.41 0

F*l 560 21 H

4 47 MAN 1BH

-1.27

-1.1 F*l 561 21 H

8 47 SAN BH

-1.1

-1.03 F*l 562 21 H

9 47 SAD 1BH

-0.75 0

F*l 563 21 H

11 47 MAD 1BH

-1.18 0

F*l 564 21 H

12 47 SAN IBH

-0.86

-0.73 F*l 16

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 2 21 STEAM GENERATOR F*1 TUBES, BOC22,2003 No. S/G Leg Row Col Indication Location Elev from Elev to Status 565 21 H

13 47 MAN IBH

-1.31

-1.01 F*1 566 21 H

19 47 MAD IBH

-1.28 0

F*1 567 21 H

22 47 MAD IBH

-1.27 0

F*1 568 21 H

23 47 MAD IBH

-1.19 0

F*1 569 21 H

24 47 MAD 1BH

-1.32 0

F*1 570 21 H

26 47 SAD IBH

-1.25 0

F*1 571 21 H

27 47 SAD IBH

-1.47 0

F*1 572 21 H

31 47 SAD IBH

-1.31 0

F*1 573 21 H

34 47 SAD 11BH

-1.2 0

F*1 574 21 H

36 47 MAD IBH

-1.1 0

F*1 575 21 H

37 47 SAD 1BH

-1.6 0

F*1 576 21 H

1 48 SAD 1BH

-1.29 0

F*1 577 21 H

3 48 SAD 1BH

-1.34 0

F*1 578 21 H

4 48 MAN 1BH

-1.22

-0.9 F*1 579 21 H

5 48 SAD IBH

-1.36 0

F*1 580 21 H

6 48 SAN IBH

-1.07

-0.99 F*1 581 21 H

9 48 SAD IBH

-1.36 0

F*1 582 21 H

11 48 MAD 1BH

-1.41 0

F*1 583 21 H

12 48 MAD IBH

-1.31 0

F*1 584 21 H

16 48 SAD IBH

-0.89 0

F*1 585 21 H

18 48 MAN IBH

-0.45

-0.26 F*1 586 21 H

20 48 MAD IBH

-1.24 0

F*l 587 21 H

22 48 MAD IBH

-1.15 0

F*l 588 21 H

23 48 MAD 1BH

-1.31 0

F*l 589 21 H

30 48 MAD IBH

-1.16 0

F*l 590 21 H

1 49 MAD IBH

-0.91 0

F*l 591 21 H

3 49 SAD 1BH

-1.36 0

F*1 592 21 H

4 49 MAD IBH

-1.39 0

Fl 593 21 H

7 49 MAD IBH

-1.39 0

F*l 594 21 H

11 49 MAD 1BH

-1.36 0

F*l 595 21 H

12 49 MAN 1BH

-0.25

-0.16 F*l 596 21 H

13 49 MAN IBH

-1.31

-1.01 F*l 597 21 H

14 49 SAN IBH

-0.65

-0.49 F*1 598 21 H

23 49 SAD IBH

-0.88 0

F*l 599 21 H

24 49 SAD IBH

-0.87 0

F*l 600 21 H

28 49 SAD IBH

-1.33 0

F*l 601 21 H

29 49 MAD 1BH

-1.26 0

F*1 602 21 H

31 49 SAD IBH

-1.26 0

F*l 603 21 H

36 49 SAD IBH

-1.26 0

F*l 604 21 H

2 50 MAN IBH

-1.35

-0.88 F*l 605 21 H

3 50 SAD 1BH

-0.9 0

F*l 606 21 H

4 50 MAN 1BH

-1.34

-1.12 F*l 607 21 H

5 50 MAN IBH

-1.31

-1.15 F*l 608 21 H

6 50 SAN IBH

-1.41

-1.38 F*l 609 21 H

7 50 MAN IBH

-0.98

-0.85 F*l 610 21 H

8 50 MAD IBH

-0.93 0

F1 611 21 H

10 50 MAN I BH

-1.28

-1.15 F1 17

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT

-4 TYAARA 1F-TDArnD C*4 T IC:Q onnV s

nna dI a I 11U-%V1 J-Q-

%r I WJI

£ 9

I I

No. S/G Leg Row Col Indication Location Elev from Elev to Status 612 21 H

12 50 MAN IBH

-0.58

-0.38 F*1 613 21 H

18 50 MAD 1BH

-1.21 0

F*1 614 21 H

19 50 MAD 1BH

-0.9 0

F*1 615 21 H

20 50 SAD 1BH

-1.25 0

F*1 616 21 H

21 50 SAD 1BH

-1.3 0

F*1 617 21 H

22 50 SAD 1BH

-1.27 0

F*1 618 21 H

24 50 MAN 1BH

-0.62

-0.24 F*1 619 21 H

25 50 SAD 1BH

-1.26 0

F*1 620 21 H

28 50 SAD 1BH

-1.27 0

F*1 621 21 H

37 50 SAD IBH

-0.9 0

F*1 622 21 H

1 51 SAN 1BH

-1.06

-0.97 F*1 623 21 H

2 51 SAD IBH

-1.37 0

F*1 624 21 H

4 51 MAN 1BH

-1.15

-1.08 F*1 625 21 H

5 51 MAN IBH

-1.2

-0.95 F*1 626 21 H

6 51 MAD IBH

-1.27 0

F*1 627 21 H

8 51 MAN IBH

-1.34

-0.86 F*1 628 21 H

11 51 SAD 1BH

-1.75 0

F*1 629 21 H

12 51 MAD 1BH

-1.3 0

F*1 630 21 H

13 51 SAD 1BH

-1.41 0

F*1 631 21 H

14 51 SAI 1BH

-0.37

-0.28 F*1 632 21 H

15 51 SAD 1BH

-1.28 0

F*1 633 21 H

16 51 MAD 1BH

-1.28 0

F*1 634 21 H

18 51 MAD IBH

-1.3 0

F*1 635 21 H

19 51 SAD 1BH

-1.21 0

F*1 636 21 H

23 51 MAD IBH

-0.88 0

F*1 637 21 H

26 51 SAD IBH

-1.34 0

F*1 638 21 H

29 51 MAD IBH

-1.3 0

F*1 639 21 H

32 51 MAD 1BH

-1.23 0

F*1 640 21 H

34 51 MAD IBH

-0.84 0

F*1 641 21 H

35 51 SAD IBH

-0.86 0

F*1 642 21 H

37 51 MAD 1BH

-1.31 0

F*1 643 21 H

38 51 SAN 1BH

-1.38

-1.27 F*1 644 21 H

1 52 SAN 1BH

-1.14

-1.11 F*1 645 21 H

2 52 MAN 1BH

-1.4

-0.96 F*1 646 21 H

3 52 MAN IBH

-1.2

-1.11 F*1 647 21 H

4 52 MAN 1BH

-1.2

-1.07 F*1 648 21 H

5 52 MAD IBH

-1.38 0

F*1 649 21 H

7 52 SAD 1BH

-1.31 0

F*1 650 21 H

9 52 SAD 1BH

-1.34 0

F*1 651 21 H

10 52 SAD 1BH

-1.36 0

F*l 652 21 H

11 52 SAD 1BH

-1.34 0

F*1 653 21 H

13 52 SAD 1BH

-1.65 0

F*l 654 21 H

15 52 MAD IBH

-1.31 0

F*l 655 21 H

16 52 SAD 1BH

-0.88 0

F*l 656 21 H

18 52 SAD 1BH

-0.9 0

F*l 657 21 H

19 52 MAD IBH

-1.33 0

F*l 658 21 H

20 52 MAD IBH

-0.89 0

F*l 18

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*l TUBES, BOC22 2003 No. S/G Leg Row Col Indication Location Elev from Elev to Status 659 21 H

22 52 SAD 1BH

-1.27 0

F*1 660 21 H

25 52 SAD 1BH

-1.36 0

F*l 661 21 H

30 52 MAD 1BH

-1.34 0

F*1 662 21 H

33 52 SAD 1BH

-1.25 0

F*l 663 21 H

35 52 SAD 1BH

-0.9 0

F*l 664 21 H

1 53 MAN 11BH

-1.47

-1.43 F*1 665 21 H

2 53 SAD 1BH

-0.93 0

F*1 666 21 H

3 53 MAD 11BH

-1.4 0

F*l 667 21 H

4 53 SAN IBH

-1.32

-1.19 F*l 668 21 H

7 53 MAN 1BH

-0.68

-0.38 F*l 669 21 H

10 53 SAN 1BH

-1.14

-1 F*l 670 21 H

11 53 SAD IBH

-1.42 0

F*l 671 21 H

12 53 SAD 1BH

-1.23 0

F*l 672 21 H

13 53 MAD 1BH

-1.33 0

F*l 673 21 H

14 53 MAD 1BH

-1.5 0

F*l 674 21 H

18 53 SAD 1BH

-1.1 0

F*1 675 21 H

20 53 SAD 1BH

-1.3 0

F*l 676 21 H

21 53 SAD 1BH

-0.95 0

F*1 677 21 H

22 53 SAD 1BH

-0.85 0

F*l 678 21 H

27 53 MAD 1BH

-0.88 0

F*1 679 21 H

35 53 SAD 1BH

-0.84 0

F*1 680 21 H

1 54 SAN 1BH

-1.21

-1.14 F*l 681 21 H

2 54 SAD 1BH

-1.48 0

F*1 682 21 H

7 54 MAN 1BH

-1.26

-1.09 F*1 683 21 H

10 54 SAD 1BH

-0.92 0

F*1 684 21 H

13 54 MAD IBH

-1.38 0

F*l 685 21 H

14 54 SAD 1BH

-1.37 0

F*l 686 21 H

17 54 MAD 1BH

-1.16 0

F*l 687 21 H

18 54 SAD 1BH

-1.21 0

F*l 688 21 H

19 54 MAN 1BH

-1.26

-1.13 F*l 689 21 H

20 54 SAD 1BH

-1.32 0

F*l 690 21 H

27 54 SAD 1BH

-1.31 0

F*l 691 21 H

29 54 MAD 1BH

-1.32 0

F*l 692 21 H

34 54 SAD 1BH

-1.29 0

F*l 693 21 H

7 55 SAD 1BH

-1.58 0

F*l 694 21 H

10 55 MAN 1BH

-1.29

-1.05 F*l 695 21 H

12 55 SAD 1BH

-1.4 0

F*l 696 21 H

15 55 MAD 1BH

-1.33 0

F*l 697 21 H

17 55 SAD 1BH

-1.23 0

F*l 698 21 H

18 55 MAD 1BH

-0.85 0

F*l 699 21 H

22 55 SAN 1BH

-1.26

-1.2 F*l 700 21 H

23 55 MAD 1BH

-1.19 0

F*l 701 21 H

27 55 SAD 1BH

-1.26 0

F*l 702 21 H

29 55 SAD 1BH

-1.3 0

F*l 703 21 H

31 55 SAD 1BH

-0.85 0

F*l 704 21 H

33 55 SAD IBH

-0.9 0

F*l 705 21 H

2 56 MAN 1

BH

-0.41

-0.24 F*l 19

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*1 TUBES. BOC22. 2003 No. S/G Leg Row Col Indication Location Elev from Elev to Status 706 21 H

4 56 MAD 1BH l -1.54 0

F*1 707 21 H

6 56 MAN 1BH

-1.16

-1.04 F*1 708 21 H

9 56 MAD IBH

-1.27 0

F*1 709 21 H

10 56 MAN 1BH

-1.29

-0.91 F*1 710 21 H

13 56 SAD 1BH_

-0.85 0

F*1 711 21 H

14 56 SAD 1BH

-1.46 0

F*1 712 21 H

18 56 SAD IBH

-1.35 0

F*1 713 21 H

20 56 SAD 1BH_

-1.28 0

F*1 714 21 H

22 56 SAD 1BH

-1.35 0

F*1 715 21 H

27 56 SAD 1BH

-0.88 0

F*1 716 21 H

29 56 SAD IBH

-1.31 0

F*1 717 21 H

34 56 MAD IBH

-0.85 0

F*I 718 21 H

2 57 MAD IBH

-1.43 0

F*1 719 21 H

3 57 MAD IBH

-1.29 0

F*1 720 21 H

4 57 SAD 1BH

-1.28 0

F*1 721 21 H

5 57 SAD IBH

-1.5 0

F*1 722 21 H

6 57 MAN IBH

-1.2

-1.01 F*1 723 21 H

7 57 MAD IBH

-1.36 0

F*1 724 21 H

8 57 MAN IBH

-0.72

-0.02 F*1 725 21 H

12 57 MAD IBH

-1.38 0

F*1 726 21 H

13 57 MAN IBH

-1.22

-0.76 F*1 727 21 H

14 57 SAD 1BH

-1.3 0

F*1 728 21 H

15 57 MAD IBH

-1.37 0

F*1 729 21 H

17 57 SAD 1BH

-1.3 0

F*1 730 21 H

18 57 MAD 1BH

-1.3 0

F*1 731 21 H

19 57 SAD 1BH

-1.28 0

F*1 732 21 H

21 57 MAD 1BH

-0.87 0

F*1 733 21 H

23 57 MAN 1BH

-1.17

-0.96 F*1 734 21 H

25 57 SAD 1BH

-1.31 0

F*1 735 21 H

27 57 SAD 1BH

-1.11 0

F*1 736 21 H

2 58 SAD 1BH

-1.39 0

F*1 737 21 H

3 58 SAD 1BH

-1 0

F*1 738 21 H

4 58 MAD 1BH

-1.41 0

F*1 739 21 H

11 58 SAD 1BH

-1.2 0

F*1 740 21 H

14 58 MAN 1BH

-1.17

-1.1 F*1 741 21 H

16 58 MAN 1BH

-1.31

-0.85 F*1 742 21 H

17 58 SAD 1BH

-1.28 0

F*1 743 21 H

18 58 SAD 1BH

-1.32 0

F*1 744 21 H

21 58 MAN 1BH

-1.36

-1.02 F*1 745 21 H

23 58 SAD IBH

-1.32 0

F*1 746 21 H

31 58 MAN 1BH

-1.44

-1.3 F*1 747 21 H

3 59 SAD 1BH

-1.29 0

F*1 748 21 H

6 59 MAD IBH

-1.38 0

F*1 749 21 H

8 59 MAN 1BH

-1.35

-0.96 F*1 750 21 H

9 59 MAD IBH

-1.39 0

F*1 751 21 H

10 59 MAN 1BH

-1.13

-1.01 F*1 752 21 H

11 59 MAN 1BH

-1.33

-1.01 F*1 20

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*1 TUBES, BOC22, 2003 No. S/G L Row Col Indication Location Elev from Elev to Status 753 21 H

12 59 MAD 1BH

-1.44 0

F*1 754 21 H

13 59 MAN 1BH

-1.28

-0.96 F*1 755 21 H

14 59 MAN IBH

-1.39

-1.25 F*1 756 21 H

17 59 SAD IBH

-1.32 0

F*1 757 21 H

19 59 MAN IBH

-1.31

-1.24 F*1 758 21 H

21 59 SAD IBH

-1.28 0

F*1 759 21 H

26 59 SAD IBH

-1.23 0

F*1 760 21 H

27 59 SAD 1BH

-0.96 0

F*

761 21 H

28 59 SAD 1BH

-1.2 0

F*1 762 21 H

31 59 MAD IBH

-1.34 0

F*1 763 21 H

33 59 SAD IBH

-1.39 0

F*1 764 21 H

3 60 MAN IBH

-1.29

-1.18 F*1 765 21 H

7 60 SAN IBH

-1.18

-0.99 F*1 766 21 H

9 60 MAD 1BH

-1.23 0

F*1 767 21 H

14 60 MAN 1BH

-1.19

-1.04 F*1 768 21 H

16 60 MAN 1BH

-1.15

-1 F*1 769 21 H

17 60 MAD IBH

-1.34 0

F*1 770 21 H

18 60 SAN 1BH

-1.3

-1.21 F*1 771 21 H

19 60 SAD IBH

-1.3 0

F1 772 21 H

23 60 MAD IBH

-1.29 0

F*1 773 21 H

24 60 SAD IBH

-0.93 0

F*1 774 21 H

25 60 MAD 1BH

-0.98 0

F*1 775 21 H

29 60 MAD 1BH

-1.27 0

F*1 776 21 H

36 60 SAD 1BH

-1.3 0

F*1 777 21 H

37 60 SAD IBH

-1.26 0

F*1 778 21 H

2 61 MAN IBH

-1.32

-1.07 F*1 779 21 H

3 61 MAN IBH

-1.39

-1.29 F*1 780 21 H

4 61 SAD 1BH

-1.26 0

F*1 781 21 H

5 61 MAN IBH

-1.29

-1.14 F*1 782 21 H

6 61 MAD 1BH

-1.95 0

F*1 783 21 H

9 61 MAN IBH

-1.2

-1.1 F*1 784 21 H

10 61 MAN IBH

-1.21

-1.09 F*1 785 21 H

13 61 MAN IBH

-0.55

-0.21 F*1 786 21 H

17 61 MAN 1BH

-1.23

-1.13 F*1 787 21 H

19 61 SAD 1BH

-1.32 0

F*1 788 21 H

23 61 SAD 1BH

-1.35 0

F*1 789 21 H

24 61 SAD 1BH

-1.32 0

F*1 790 21 H

31 61 SAD 1BH

-3.5 0

F*1 791 21 H

33 61 MAD 1BH

-1.42 0

F*1 792 21 H

34 61 MAD 1BH

-1.3 0

F*1 793 21 H

37 61 SAD IBH

-1.33 0

F*1 794 21 H

1 62 SAD 1BH

-1.41 0

F*1 795 21 H

2 62 MAN 1

BH

-1.12

-1.02 F*1 796 21 H

3 62 SAD IBH

-1.36 0

F*1 797 21 H

5 62 MAN IBH

-1.22

-1.11 F*1 798 21 H

6 62 SAD IBH

-1.47 0

F*1 799 21 H

8 62 MAN I1BH

-1.24

-1.16 F*1 21

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*1 TUBES, BOC22, 2003 No. S/G g Row Col Indication Location Elev from Elev to Status 800 21 H

12 62 SAN 1BH

-1.25

-1.15 F*1 801 21 H

13 62 MAD IBH

-1.34 0

F*1 802 21 H

14 62 MAN IBH

-1.28

-1.06 F*1 803 21 H

17 62 MAD IBH

-1.42 0

F*1 804 21 H

21 62 SAD IBH

-1.1 0

F*1 805 21 H

27 62 MAD IBH

-0.83 0

F*l 806 21 H

35 62 MAD IBH

-1.35 0

F*l 807 21 H

36 62 SAD IBH

-1.35 0

F*1 808 21 H

37 62 SAD IBH

-0.9 0

F*1 809 21 H

38 62 SAD IBH

-1.32 0

F*l 810 21 H

3 63 MAN IBH

-1.17

-0.97 F*l 811 21 H

5 63 MAN 1BH

-1.22

-1.09 F*1 812 21 H

7 63 SAD 1BH

-1.4 0

F*l 813 21 H

9 63 SAD IBH

-1.34 0

F*l 814 21 H

11 63 SAD IBH

-1.39 0

F*l 815 21 H

14 63 MAD 1BH

-1.37 0

F*l 816 21 H

15 63 SAD 1BH

-1.21 0

F*1 817 21 H

16 63 SAD 1BH

-1.33 0

F*l 818 21 H

18 63 SAD 1BH

-0.89 0

F*l 819 21 H

19 63 MAN 1BH

-0.69

-0.16 F*l 820 21 H

25 63 MAD 1BH

-1.3 0

F*l 821 21 H

28 63 MAD 1BH

-1.3 0

F*l 822 21 H

34 63 MAI 1BH

-0.55

-0.18 F*l 823 21 H

36 63 SAD 1BH

-0.89 0

F*l 824 21 H

37 63 MAD IBH

-1.38 0

F*l 825 21 H

1 64 SAD 1BH

-1.35 0

F*l 826 21 H

3 64 SAN 1BH

-1.18

-1.11 F*l 827 21 H

4 64 MAN 1BH

-1.19

-1.09 F*l 828 21 H

5 64 MAN 1BH

-1.49

-1.12 F*l 829 21 H

6 64 MAN IBH

-1.05

-0.97 F*l 830 21 H

7 64 MAN 1BH

-1.2

-1.1 F*l 831 21 H

10 64 MAD 1BH

-1.28 0

F*l 832 21 H

11 64 MAD 1BH

-1.59 0

F*l 833 21 H

12 64 MAN 1BH

-1.12

-1 F*l 834 21 H

14 64 MAN 1BH

-1.21

-1.11 F*1 835 21 H

15 64 SAD 1BH

-1.25 0

F*l 836 21 H

19 64 MAD IBH

-1.38 0

F*l 837 21 H

22 64 SAD IBH

-1.35 0

F*l 838 21 H

29 64 SAD IBH

-0.8 0

F*l 839 21 H

34 64 MAD IBH

-1.22 0

F*l 840 21 H

35 64 SAD IBH

-1.28 0

F*l 841 21 H

37 64 SAD IBH

-1.34 0

F 842 21 H

1 65 MAD 1BH

-1.25 0

F*l 843 21 H

2 65 SAD IBH

-1.42 0

F*1 844 21 H

4 65 SAI 1BH

-0.36

-0.23 F*l 845 21 H

5 65 MAN IBH

-1.27

-1.13 F*l 846 21 H

8 65 SAN 1BH

-1.24

-1.13 F*l 22

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*l TUBES. BOC22. 2003 No. S/G Leg Row Cot Indication Location Elev from Eev to Status 847 21 H

10 65 MAD l11BH r -1.24 0

F*l 848 21 H

13 65 MAI l1BH l -0.49

-0.28 F*l 849 21 H

14 65 SAD r1BH l -1.19 0

F*1 850 21 r H 17 651 MAD l1BH l -1.33 0

F*l 851 21 H

18 65 SAD l1BH r

-1.36 0

F*l 852 21 H

20 65 SAD IBH

-1 0

F*l 853 21 H

25 65 SAD IBH

-0.79 0

F*l 854 21 H

40 65 MAD 1BH

-1.32 0

F*l 855 21 H

3 66 MAD 1BH

-1.3 0

F*1 856 21 H

5 66 MAN 1BH

-1.

-1.

06 F*l 857 21 H

6 66 SAN 1BH

-1.27

-1.2 F*1 858 21 H

7 66 SAD 1BH

-1.27 0

F*l 859 21 H

12 66 MAD 1BH

-1.33 0

F*l 860 21 H

14 66 SAD 1BH

-1.29 0

F*l 861 21 H

15 66 MAD IBH

-1.41 0

F*1 862 21 H

16 66 SAN 1BH

-2.03

-1.95 F*l 863 21 H

17 66 SAD 1BH

-1.4 0

F*l 864 21 H

18 66 SAD 1BH

-1.36 0

F*l 865 21 H

19 66 SAD 1BH

-0.82 0

F*l 866 21 H

21 66 SAD BH

-1.24 0

Fl 867 21 H

22 66 SAD 1BH

-1.23 0

F*l 868 21 H

24 66 MAD IBH

-1.18 0

Fl 869 21 H

25 66 SAD IBH

-1.26 0

F*1 870 21 1H 35 661 SAD IBH

-1.35 0

F~l 871 21 H

1 67 MAD 1BH

-1.31 0

F*l 872 21 H

2 67 SAD 1BH

-1.42 0

F*l 873 21 H

3 67 MAD 1BH

-1.36 0

F*l 874 21 H

4 67 SAD 1BH

-1.17 0

F*l 875 21 H

5 67 MAD 1BH

-1.35 0

F*l 876 21 H

6 67 SAD 1BH

-1.33 0

F*1 877 21 H

8 67 SAD 1BH

-0.86 0

F*l 878 21 H

11 67 SAD 1BH

-1.34 0

F*l 879 21 H

12 67 MAD IBH

-1.36 0

F*1 880 21 H

16 67 SAN IBH

-3.87

-3.76 F*l 881 21 H

19 67 SAD IBH

-0.79 0

F*l 882 21 H

20 67 SAD IBH

-0.92 0

F*l 883 21 H

21 67 MAD IBH

-1.3 0

F*l 884 21 H

24 67 MAN IBH

-1.27

-1.08 F*l 885 21 H

25 67 SAN 1BH

-3.88

-3.67 F*l 886 21 H

26 67 SAN 1BH

-1.26

-1.16 F*l 887 21 H

30 67 MAD 1BH

-1.25 0

F*l 888 21 H

34 67 MAD IBH

-1.41 0

F*l 889 21 H

4 68 MAN IBH

-1.35

-0.83 F*l 890 21 H

5 68 MAN 1BH

-1.17

-1.05 F*l 891 21 H

7 68 MAN 1BH

-1.18

-1.06 F*1 892 21 H

12 68 MAN 1BH

-0.46

-0.22 Fl 893 21 H

13 68 MAD 1BH

-1.39 0

F*1 23

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT DI QTArA r(NMIPATd% *1 TI IRF.

nrss nnA No. S/G L Row Col Indication Location Elev from Elev to Status 894 21 H

14 68 MAD 1BH

-1.35 0

F*1 895 21 H

15 68 MAD 1BH

-1.44 0

F*1 896 21 H

17 68 MAD 1BH

-1.25 0

F*1 897 21 H

19 68 SAD 1BH

-0.85 0

F*1 898 21 H

20 68 SAD IBH

-0.85 0

F*1 899 21 H

1 69 SAD IBH

-1.3 0

F*1 900 21 H

4 69 MAD 1BH

-1.42 0

F*1 901 21 H

5 69 SAD 1BH

-1.35 0

F*1 902 21 H

6 69 SAD 1BH

-1.34 0

F*1 903 21 H

8 69 SAD 1BH

-1.4 0

F*1 904 21 H

11 69 SAN 1BH

-1.14

-1.05 F*1 905 21 H

12 69 MAD 1BH

-1.33 0

F*1 906 21 H

13 69 SAD 1BH

-1.34 0

F*1 907 21 H

14 69 SAD 1BH

-1.34 0

F*1 908 21 H

15 69 MAD IBH

-1.47 0

F*1 909 21 H

16 69 SAD 1BH

-1.35 0

F*1 910 21 H

17 69 SAD 1BH

-1.3 0

F*1 911 21 H

20 69 MAD 1BH

-1.41 0

F*1 912 21 H

25 69 SAD 1BH

-1.42 0

F*1 913 21 H

26 69 SAD IBH

-1.41 0

F*1 914 21 H

33 69 SAD IBH

-1.48 0

F*1 915 21 H

35 69 SAD 1BH

-1.32 0

F*1 916 21 H

2 70 SAD 1BH

-1.23 0

F*1 917 21 H

4 70 SAD 1BH

-1.42 0

F*1 918 21 H

5 70 MAN 1BH

-1.17

-1.07 F*1 919 21 H

6 70 SAD 1BH

-1.41 0

F*1 920 21 H

7 70 SAD 1BH

-0.86 0

F*1 921 21 H

9 70 MAD 1BH

-1.2 0

F*1 922 21 H

11 70 MAD 1BH

-0.87 0

F*1 923 21 H

13 70 MAD IBH

-1.4 0

F*l 924 21 H

16 70 MAD 1BH

-1.4 0

F*1 925 21 H

17 70 MAN 1BH

-0.52

-0.2 F*l 926 21 H

25 70 SAD 1BH

-1.49 0

F*l 927 21 H

2 71 MAD 1BH

-0.92 0

F*l 928 21 H

4 71 MAD 1BH

-0.96 0

F*l 929 21 H

5 71 MAD 1BH

-1.41 0

F*l 930 21 H

6 71 MAN IBH

-1.36

-1.25 F*l 931 21 H

7 71 MAD 1BH

-1.55 0

F*1 932 21 H

8 71 MAD IBH

-1.36 0

F*l 933 21 H

9 71 SAD 1BH

-1.46 0

F*1 934 21 H

10 71 MAN 1BH

-1.14

-1 F*l 935 21 H

11 71 MAN 1BH

-1.13

-1 F*l 936 21 H

12 71 SAD 1BH

-1.28 0

F*l 937 21 H

16 71 SAD 1BH

-0.87 0

F*1 938 21 H

17 71 MAD 1BH

-1.34 0

F*l 939 21 H

21 71 MAD 1BH

-1.42 0

F*1 940 21 H

22 71 MAD 1BH

-0.86 0

F*l 24

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS - 15 DAY REPORT 21 STEAM GENERATOR F*1 TUBES. BOC22. 2003 No. S/G L Row Col Indication Location Elev from Elev to Status 941 21 H

30 71 SAD 1BH

-1.3 0

F*1 942 21 H

31 71 SAD 1BH

-1.37 0

F*1 943 21 H

34 71 SAI 1BH

-0.52

-0.46 F*l 944 21 H

2 72 MAD IBH

-1.37 0

F*1 945 21 H

4 72 SAD 1BH 1

-1 0

F*1 946 21 H

5 72 SAD IBH

-1.41 0

F*1 947 21 H

6 72 SAD 1BH

-1.3 0

F*1 948 21 H

8 72 MAN 1BH

-1.09

-1.02 F*1 949 21 H

11 72 MAN 1BH

-1.16

-0.97 F*1 950 21 H

12 72 SAD IBH

-1.46 0

F*1 951 21 H

15 72 SAD IBH

-1.29 0

F*1 952 21 H

16 72 SAD IBH

-1.42 0

F*1 953 21 H

17 72 SAD 1BH

-1.39 0

F*1 954 21 H

18 72 MAD IBH

-1.48 0

F*1 955 21 H

23 72 SAD 1BH

-1.24 0

F*1 956 21 H

36 72 MAD 1BH

-1.46 0

F*1 957 21 H

38 72 SAD IBH

-1.31 0

F*1 958 21 H

2 73 SAD IBH

-0.95 0

F*1 959 21 H

3 73 MAN 1BH

-1.25

-1.12 F*1 960 21 H

5 73 MAN 1BH

-1.16

-1.06 F*1 961 21 H

11 73 MAN 1BH

-1.17

-1.07 F*1 962 21 H

12 73 MAD IBH

-0.89 0

F*1 963 21 H

16 73 MAD 1BH

-0.86 0

F*1 964 21 H

17 73 MAD 1BH

-0.88 0

F*1 965 21 H

18 73 MAD IBH

-1.45 0

F*1 966 21 H

23 73 SAD IBH

-0.82 0

F*1 967 21 H

1 74 SAD IBH

-1.41 0

F*1 968 21 H

2 74 SAD 1BH

-1.35 0

F*1 969 21 H

3 74 SAN IBH

-1.26

-1.04 F*1 970 21 H

4 74 MAD 1BH

-1.43 0

F*1 971 21 H

5 74 MAN IBH

-1.23

-1.12 F*1 972 21 H

6 74 SAD IBH

-1.32 0

F*1 973 21 H

7 74 MAD IBH

-1.34 0

F*1 974 21 H

11 74 MAN IBH

-1.29

-1.14 F*1 975 21 H

13 74 SAD 1BH

-1.38 0

F*1 976 21 H

15 74 SAD 1BH

-1.37 0

F*1 977 21 H

19 74 SAD 1BH

-1.41 0

F*1 978 21 H

25 74 SAD 1BH

-0.85 0

F*1 979 21 H

28 74 SAD IBH

-0.94 0

F*1 980 21 H

29 74 SAD 1BH

-1.49 0

F*1 981 21 H

37 74 SAD IBH

-1.26 0

F*1 982 21 H

4 75 SAD 1BH

-1.34 0

F*1 983 21 H

5 75 MAN 1BH

-1.36

-1.26 F*1 984 21 H

8 75 MAD 1BH

-0.9 0

F*I 985 21 H

11 75 SAD IBH

-1.36 0

F*1 986 21 H

17 75 MAD 1BH

-1.4 0

F*1 987 21 H

21 75 SAD 1BH

-1.47 0

F*I 25

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS - 15 DAY REPORT 21 STEAM GENERATOR F*l TUBES, BOC22, 2003 I

No. S/G Leg Row Co Indication Location Elev from Elev to Status 988 21 H

22 1 751 SAD IBH

-1.46 0

F*l 989 21 H

2 1761 SAD IBH

-1.38 0

F*1 990 21 H

3 1761 SAD IBH

-1.37 0

F*l 991 21 H

5 76 SAD IBH

-1.31 0

F*l 992 21 H

7 76 MAD IBH

-1.41 0

F*l 993 21 H

9 76 MAD 11BH

-1.39 0

F*l 994 21 H

10 76 MAD 11BH

-1.3 0

F*1 995 21 H

11 76 SAD 1BH

-1.38 0

F*l 996 21 H

18 76 SAD 1BH

-0.87 0

F*l 997 21 H

24 76 SAD 1BH

-1.33 0

F*l 998 21 H

28 76 SAN 1BH

-1.35

-1.28 F*l 999 21 H

3 77 MAD IBH

-0.93 0

F*1 1000 21 H

4 77 SAD IBH

-1.33 0

F*l 1001 21 H

5 77 SAD IBH

-1.77 0

F*l 1002 21 H

6 77 MAD IBH

-1.4 0

F*l 1003 21 H

7 77 SAN 11BH

-1.2

-1.07 F*l 1004 21 H

10 77 MAD 1BH

-1.33 0

F*l 1005 21 H

11 77 SAD IBH

-1.44 0

F*l 1006 21 H

16 77 SAD IBH

-0.87 0

F*l 1007 21 H

17 77 SAI 1BH

-0.63

-0.12 F*1 1008 21 H

20 77 SAD 1BH

-1.41 0

F*l 1009 21 H

22 77 SAD 1BH

-1.16 0

F*l 1010 21 H

3 78 MAD 1BH

-1.53 0

F*l 1011 21 H

4 78 MAD 1BH

-1.08 0

F*l 1012 21 H

5 78 MAD IBH

-1.44 0

F*l 1013 21 H

7 78 MAN IBH

-1.28

-1.15 F*l 1014 21 H

9 78 MAD IBH

-1.39 0

F*l 1015 21 H

11 78 MAN IBH

-1.15

-1.05 F*l 1016 21 H

2 79 MAD 1BH

-1.45 0

F*l 1017 21 H

4 79 SAD 1BH

-1.37 0

F*l 1018 21 H

5 79 MAD 1BH

-1.37 0

F*1 1019 21 H

7 79 MAN 1BH

-1.3

-1.18 F*1 1020 21 H

8 79 SAD 1BH

-0.93 0

F*l 1021 21 H

10 79 SAD IBH

-1.39 0

F*l 1022 21 H

11 79 SAD IBH

-1.47 0

F*l 1023 21 H

12 79 SAN 1BH

-1.48

-1.42 F*1 1024 21 H

17 79 MAI 1BH

-0.69

-0.14 F*l 1025 21 H

19 79 MAD 1BH

-1.52 0

F*1 1026 21 H

21 79 SAD IBH

-1.29 0

F*l 1027 21 H

3 80 SAD IBH

-1.31 0

F*l 1028 21 H

5 80 SAD 1BH

-1.56 0

F*1 1029 21 H

8 80 SAN 1BH

-1.31

-1.26 F*1 1030 21 H

9 80 SAD 1BH

-1.38 0

F*l 1031 21 H

11 80 MAD IBH

-1.37 0

F*1 1032 21 H

12 80 SAD IBH

-1.26 0

F*l 1033 21 H

28 80 SAN 1BH

-1.3

-1.24 F*l 1034 21 H

1 81 MAD IBH

-0.9 0

F*l 26

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*1 TUBES. BOC22. 2003 No. SIG Lg

_Row Col Indication Location Elev from Elev to Status 1035 21 H

8 81 SAD 11BH

-1.2 0

F*1 1036 21 H

11 81 SAD 1BH

-1.45 0

F*1 1037 21 H

19 81 SAD IBH

-1.32 0

F*1 1038 21 H

21 81 SAD 1BH

-1.3 0

F*1 1039 21 H

1 82 SAD 11BH

-1.4 0

F*1 1040 21 H

7 82 SAD 1BH

-1.52 0

F*1 1041 21 H

9 82 MAD 1BH

-0.88 0

F*1 1042 21 H

11 82 SAD 11BH

-1.36 0

F*1 1043 21 H

12 82 SAD 1BH

-1.44 0

F*1 1044 21 H

26 82 SAD IBH

-1.37 0

F*1 1045 21 H

2 83 SAD IBH

-0.94 0

F*1 1046 21 H

4 83 SAD 1BH

-1.3 0

F*1 1047 21 H

9 83 MAD IBH

-1.52 0

F*1 1048 21 H

4 84 SAD 1BH

-1.37 0

F*1 1049 21 H

5 84 MAD 1BH

-1 0

F*1 1050 21 H

9 84 SAD 1BH

-1.42 0

F*1 1051 21 H

11 84 MAD IBH

-1.45 0

F*1 1052 21 H

12 84 MAD IBH

-0.9 0

F*1 1053 21 H

7 85 SAD IBH

-1.49 0

F*1 1054 21 H

9 85 MAD IBH

-1.35 0

F*1 1055 21 H

11 85 SAD 1BH

-1.26 0

F*1 1056 21 H

13 85 MAD IBH

-1.39 0

F*1 1057 21 H

18 86 SAN IBH

-1.24

-1.12 F*1 1058 21 H

3 87 SAD 1

BH

-1.31 0

F*1 1059 21 H

9 89 SAD 1BH

-1.23 0

F*1 1060 21 H

10 89 MAD 1BH

-1.25 0

F*1 21 STEAM GENERATOR F*2 TUBES, BOC22, 2003 No.lSGl Leg Row Col Indication Location Elev from Elev to Status 1

21 H

6 14 SAN 2BH l -1.02

-0.9 F*2 2

21 H

4 17 SAD 2BH

-3.11 0

F*2 3

21 H

14 17 SAN 2BH

-1.14

-1.08 F*2 4

21 H

18 17 SAN 2BH

-0.82

-0.71 F*2 5

21 H

19 18 MAN 2BH

-0.89

-0.73 F*2 6

21 H

27 18 SAN 2BH

-0.97

-0.86 F*2 7

21 H

6 19 SAN 2BH

-0.97

-0.87 F*2 8

21 H

27 20 MAN 2BH

-1.05

-0.87 F*2 9

21 H

2 21 SAN 2BH

-1

-0.82 F*2 10 21 H

9 21 SAN 2BH

-1.03

-0.68 F*2 11 21 H

3 22 SAN 2BH

-0.65

-0.59 F*2 12 21 H

16 22 SAN 2BH

-1.02

-0.91 F*2 13 21 H

3 24 SAN 2BH

-1.02

-0.86 F*2 14 21 H

6 24 SAN 2BH

-0.89

-0.75 F*2 15 21 H

19 25 MAD 2BH

-3.03 0

F*2 16 21 H

4 26 SAN 2BH

-1.09

-0.8 F*2 17 21 H

18 26 SAN 2BH

-0.91

-0.74 F*2 18 21 H

12 27 SAN 2BH

-0.73

-0.64 F*2 27

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*2 TUBES, BOC22, 2003 No. SIGLegRow Col Indication Location Elev from Elev to Status 19 21 H

28 27 SAN 2BH

-1.29

-0.75 F*2 20 21 H

9 28 MAN 2BH

-2.27

-1.97 F*2 21 21 H

38 28 SAN 2BH l

-0.86

-0.72 F*2 22 21 H

4 29 MAN 2BH

-0.93

-0.82 F*2 23 21 H

13 1291 SAN 2BH l -3.19

-3.12 F*2 24 21 H

9 30 SAN 2BH l -0.69

-0.32 F*2 25 21 H

18 30 SAN 2BH

-1.01

-0.86 F*2 26 21 H

23 34 SAN 2BH l -0.96

-0.81 F*2 27 21 H

5 36 MAN 2BH

-2.49

-1.88 F*2 28 21 H

7 361 SAN 2BH

-0.9

-0.72 F*2 29 21 H

8 36 SAN 2BH l -0.86

-0.72 F*2 30 21 H

14 36 MAD 2BH

-3 0

F*2 31 21 H

4 38 SAN 2BH l

-0.86

-0.82 F*2 32 21 H

14

40.

SAN 2BH

-2.88

-1.28 F*2 33 21 H

33 41 SAN 2BH l

-0.85

-0.77 F*2 34 21 H

2 42 SAN 2BH

-0.99

-0.95 F*2 35 21 H

9 42 MAN 2BH l

-0.74

-0.66 F*2 36 21 H

9 44 SAN 2BH

-0.78

-0.65 F*2 37 21 H

10 44 SAD 2BH

-2.9 0

F*2 38 21 H

19 44 SAN 2BH

-1.87

-1.71 F*2 39 21 H

30 45 SAN 2BH

-1.05

-0.99 F*2 40 21 H

3 46 SAN 2BH

-0.75

-0.62 F*2 41 21 H

9 46 SAN 2BH

-1.98

-1.32 F*2 42 21 H

12 46 MAN 2BH

-2.6

-1.82 F*2 43 21 H

20 46 SAD 2BH

-1.5 0

F*2 44 21 H

6 47 SAN 2BH

-2.84

-1.87 F*2 45 21 H

7 47 SAN 2BH

-0.77

-0.46 F*2 46 21 H

14 47 SAN 2BH

-2.86

-1.48 F*2 47 21 H

18 47 SAD 2BH

-4.53 0

F*2 48 21 H

10 48 MAN 2BH

-2.87

-2.75 F*2 49 21 H

8 49 MAN 2BH

-2.48

-1.63 F*2 50 21 H

15 49 MAD 2BH

-3.35 0

F*2 51 21 H

14 50 SAN 2BH

-2.16

-1.61 F*2 52 21 H

17 50 SAD 2BH

-3.58 0

F*2 53 21 H

12 52 SAD 2BH

-1.81 0

F*2 54 21 H

14 52 SAN 2BH

-0.97

-0.89 F*2 55 21 H

21 54 SAN 2BH

-0.81

-0.76 F*2 56 21 H

11 55 MAN 2BH

-0.63

-0.52 F*2 57 21 H

7 56 SAN 2BH

-0.59

-0.52 F*2 58 21 H

11 56 SAN 2BH

-0.75

-0.64 F*2 59 21 H

1 57 SAN 2BH

-0.81

-0.75 F*2 60 21 H

11 57 SAN 2BH

-1.18

-1.09 F*2 61 21 H

5 58 SAN 2BH

-0.86

-0.75 F*2 62 21 H

1 59 SAN 2BH

-0.91

-0.79 F*2 63 21 H

2 60 MAN 2BH

-0.68

-0.36 F*2 64 21 H

4 60 SAN 2BH

-0.61

-0.5 F*2 65 21 H

5 60 MAN 2BH

-0.83

-0.67 F*2 28

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 21 STEAM GENERATOR F*2 TUBES. BOC22. 2003 No.lSIG lL Row Col Indication Location Elev from Elev to Status 66 21 H

6 60 SAD 2BH

-1.11 0

F*2 67 21 H

4 62 SAN 2BH

-0.86

-0.71 F*2 68 21 H

10 62 SAN 2BH

-1.02

-0.85 F*2 69 21 H

25 62 MAI 2BH

-0.52

-0.08 F*2 70 21 H

8 63 MAN 2BH

-1.1

-0.88 F*2 71 21 H

8 64 SAN 2BH

-0.62

-0.5 F*2 72 21 H

17 64 MAN 2BH

-1.14

-1.03 F*2 73 21 H

12 65 MAN 2BH

-0.9

-0.78 F*2 74 21 H

16 65 SAN 2BH

-0.97

-0.83 F*2 75 21 H

10 66 SAN 2BH

-0.75

-0.63 F*2 76 21 H

14 67 SAD 2BH

-3.02 0

F*2 77 21 H

34 68 MAN 2BH

-1.1

-0.77 F*2 78 21 H

3 71 MAN 2BH

-0.94

-0.86 F*2 79 21 H

10 73 SAN 2BH

-0.87

-0.79 F*2 80 21 H

9 74 SAN 2BH

-0.99

-0.91 F*2 21 STEAM GENERATOR EF* TUBES, BOC22, 2003 No. S/Gl_ Row Col Indication Location Elev from Elev to Status 1 21 H

4 11 MAN EBH

-10.61

-10.24 EF*

2 21 H

3 17 SAD EBH

-13.35 0

EF*

3 21 H

9 18 SAI EBH

-0.41

-0.35 EF*

4 21 H

30 27 SAN EBH

-9.12

-9.04 EF*

5 21 H

13 30 SAD EBH

-13.71 0

EF*

6 21 H

19 32 SAN EBH

-12.22

-11.72 EF*

7 21 H

10 43 SAN EBH

-13.25

-11.37 EF*

8 21 H

1 46 MAN EBH

-12.87

-11.59 EF*

9 21 H

28 48 SAN EBH

-13.31

-10.08 EF*

10 21 H

25 49 MAN EBH

-13.03

-9.87 EF*

11 21 H

28 55 SAN EBH

-13.45

-10.28 EF*

12 21 H

16 56 SAN EBH

-9.3

-9.27 EF*

13 21 H

7 61 SAN EBH

-9.16

-9.05 EF*

14 21 H

7 67 MAN EBH

-9.63

-9.16 EF*

22 STEAM GENERATOR F*0 TUBES, BOC22, 2003 No. S/GlLeglRow Col Indication Location Elev from Elev to Status 1

22 H

4 1

SAN TRH

-2.54

-2.44 F*0 2

22 H

1 2

SAN TRH

-2.02

-1.91 F*0 3

22 H

1 7

SAN TRH

-2.81

-2.68 F*0 4

22 H

3 10 SAN TRH

-2.37

-2.39 rF*

5 22 H

35 201 SAN TRH

-2.34

-2.19 F*0 6

22 H

35 23 SAN TRH

-2.29

-2.2 F*0 7

22 H

37 25 SAN TRH

-2.26

-2.1 F*0 8

22 H

1 27 SAN TRH

-2.54

-2.43 F*0 9

22 H

8 27 SAD TRH

-2.57 0

F*0 10 22 H

1 281 SAN TRH

-2.43

-2.3 F*0 11 22 H

3 281 SAN TRH

-2.37

-2.23 F*0 29

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 22 STEAM GENERATOR F*O TUBES, BOC22, 2003 No. SIG Leg Row Col Indication Location Elev from Elev to Status 12 22 H

2 29 SAN TRH

-2.47

-2.33 F*O 13 22 H

3 29 SAN TRH

-2.59

-2.48 F*0 14 22 H

2 30 SAN TRH

-2.51

-2.48 F*0 15 22 H

1 33 MAN TRH

-2.72

-2.5 F*0 16 22 H

1 34 SAN TRH

-2.53

-2.34 F*0 17 22 H

42 35 SAN TRH

-2.6

-2.5 F*0 18 22 H

1 37 MAN TRH

-2.77

-2.6 F*O 19 22 H

2 45 SAN TRH

-2.29

-2.16 F*0 20 22 H

1 46 SAN TRH

-2.74

-2.57 F*0 21 22 H

7 48 SAN TRH

-2.5

-2.4 F*O 22 22 H

9 48 SAN TRH

-2.3

-2.06 F*O 23 22 H

10 48 SAN TRH

-2.47

-2.35 F*O 24 22 H

5 49 SAN TRH

-2.41

-2.34 F*O 25 22 H

7 49 SAN TRH

-2.46

-2.24 F*0 26 22 H

8 49 SAI TRH

-2.49

-2.3 F*O 27 22 H

3 50 SAN TRH

-2.67

-2.58 F*O 28 22 H

4 50 SAN TRH

-2.75

-2.66 F*O 29 22 H

6 50 SAN TRH

-2.75

-2.66 F*O 30 22 H

7 50 SAN TRH

-2.34

-2.23 F*O 31 22 H

10 50 SAN TRH

-2.83

-2.74 F*0 32 22 H

37 50 SAI TRH

-2.57

-2.42 F*O 33 22 H

4 51 MAN TRH

-2.43

-2.35 F*O 34 22 H

7 51 SAN TRH

-2.37

-2.27 F*O 35 22 H

1 52 MAN TRH

-2.74

-2.4 F*O 36 22 H

10 52 SAN TRH

-2.81

-2.71 F*O 37 22 H

1 53 MAN TRH

-2.8

-2.52 F*O 38 22 H

6 53 SAN TRH

-2.7

-2.6 F*O 39 22 H

7 53 SAN TRH

-2.66

-2.55 F*O 40 22 H

34 53 MAN TRH

-2.26

-2.2 F*O 41 22 H

5 541 MAN TRH

-2.62

-2.5 F*0 42 22 H

7 55 SAI TRH

-2.37

-2.33 F*0 43 22 H

34 55 MAN TRH

-2.37

-2.19 F*O 44 22 H

1 56 MAN TRH

-2.74

-2.5 F*O 45 22 H

2 56 SAN TRH

-2.63

-2.53 F*O 46 22 H

34 56 MAN TRH

-2.3

-2.09 F*0 47 22 H

37 57 MAN TRH

-2.34

-2.2 F*0 48 22 H

9 58 SAN TRH

-2.78

-2.63 F*0 49 22 H

34 58 MAN TRH

-2.52

-2.36 F*0 50 22 H

7 59 SAN TRH

-2.6

-2.56 F*0 51 22 H

26 59 MAN TRH

-2.32

-2.24 F*O 52 22 H

37 59 MAN TRH

-2.22

-2.12 F*O 53 22 H

34 60 MAN TRH

-2.31

-2.14 F*0 54 22 H

11 61 SAN TRH

-2.59

-2.49 F*0 55 22 H

1 62 MAN TRH

-2.7

-2.44 F*

56 22 H

8 63 SAN TRH

-2.87

-2.74 F*0 57 22 H

17 63 MAN TRH

-2.63

-2.57 F*O 58 22 H

34 63 MAN TRH

-2.39

-2.25 F*O 30

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 22 STEAM GENERATOR F*0 TUBES. SOC22. 2003 No. S/G Leg Row Indication Location Elev from Elev to Status 59 22 H

5 641 SAN TRH

-2.31

-2.27 F*O 60 22 H

8 64 SAN TRH

-2.39

-2.33 F*O 61 22 H

7 65 MAN TRH

-2.48

-2.45 F*O 62 22 H

8 66 MAN TRH

-2.37

-2.27 l F*0 63 22 H

18 66 SAN TRH

-1.44

-1.33 F*O 64 22 H

8 671 SAN TRH

-2.41

-2.37 F*O 65 22 H

8 68 SAN TRH

-2.36

-2.25 F*O 66 22 H

34 68 MAN TRH

-2.32

-2.1 F*O 67 22 H

1 69 MAN TRH

-2.78

-2.61 F*0 68 22 H

1 70 MAN TRH

-2.74

-2.52 F*O 69 22 H

37 701 MAN TRH

-2.2

-2.07 F*O 70 22 H

6 71 SAN TRH

-2.45

-2.35 F*O 71 22 H

7 71 SAN TRH

-2.4

-2.35 F*O 72 22 H

11 71 SAN TRH

-2.54

-2.41 F*0 73 22 H

24 71 MAN TRH

-2.31

-2.17 F*0 74 22 H

1 72 MAN TRH

-2.73

-2.5 F*O 75 22 H

5 72 SAN TRH

-2.82

-2.64 F*O 76 22 H

34 72 SAN TRH

-2.13

-2.1 F*O 77 22 H

37 72 SAN TRH

-2.2

-2.01 F*0 78 22 H

1 74 MAN TRH

-2.73

-2.56 F*O 79 22 H

4 74 MAN TRH

-2.25

-2.19 F*O 80 22 H

5 74 SAN TRH

-2.42

-2.32 F*O 81 22 H

6 74 MAN TRH

-2.2

-2.11 F*O 82 22 H

6 75 SAN TRH

-2.46

-2.32 F*0 83 22 H

1 76 MAN TRH

-2.77

-2.62 F*O 84 22 H

1 77 MAN TRH

-2.65

-2.48 F*O 85 22 H

4 77 SAN TRH

-2.52

-2.45 F*O 86 22 H

6 77 MAN TRH

-2.38

-2.3 F*O 87 22 H

1 78 MAN TRH

-2.7

-2.27 F*O 88 22 H

4 78 SAN TRH

-2.61

-2.44 F*0 89 22 H

1 79 MAN TRH

-2.68

-2.52 F*0 90 22 H

3 79 MAN TRH

-2.51

-2.38 F*O 91 22 H

1 80 MAN TRH

-2.66

-2.47 F*O 92 22 H

4 80 SAN TRH

-2.56

-2.4 F*O 93 22 H

5 80 SAN TRH

-2.52

-2.39 F*O 94 22 H

4 81 SAN TRH

-2.44

-2.34 F*0 95 22 H

1 82 MAN TRH

-2.66

-2.32 F*O 96 22 H

5 82 SAN TRH

-2.53

-2.36 F*O 97 22 H

1 83 SAN TRH

-2.72

-2.49 F*O 98 22 H

6 85 SAN TRH

-2.43

-2.33 F*O 99 22 H

7 85 SAN TRH

-2.55

-2.48 F*0 100 22 H

6 86 SAN TRH

-2.43

-2.36 F*O 101 22 H

1 87 SAN TRH

-2.62

-2.45 F*O 102 22 H

4 88 SAN TRH

-2.46

-2.39 F*O 103 22 H

13 88 SAI TRH

-1.59

-1.52 F*O 104 22 H

6 91 SAN TRH

-2.54

-2.42 F*O0 105 22 H

6 94 MAN TRH

-2.54

-2.3 F*O 31

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS - 15 DAY REPORT 99 QTrAl&A rCTCIATn0 9:*4 TI tIrF.

nnrV9 93nna oL o

I clvl Ic5G v

l 4 -

I

.vL No. S/G Leg Row Coll Indication Location Elev from Elev to Status 1 22 H

15 7

SAD IBH

-1.05 0

F*1 2

22 H

4 8

SAD I1BH l

-1.4 0

F*1 3

22 H

1 10 SAN IBH

-2.17

-2.08 F*1 4

22 H

21 11 SAD I1BH

-1.42 0

F*1 5

22 H

15 131 SAD I1BH l

-1.11 0

F*1 6

22 H

24 13 SAD I1BH l

-1.46 0

F*1l 7

22 H

4 14 SAN I1BH l

-2.37

-2.2 F*1 8

22 H

17 14 MAD IBH

-1.32 0

F*1 9

22 H

18 14 SAN IBH

-1.39

-1.34 F*1 10 22 H I 25 141 MAI I1BH l

-0.65

-0.13 F*1 11 22 H

2 151 SAN I1BH l

-2.3

-2.19 F*1 12 22 H

4 15 SAD T1BH l

-1.25 0

F*

13 22 H

9 15 SAD T1BH l

-1.16 0

F*1 14 22 H

14 15 SAD T1BH l

-1.06 0

F*1 15 22 H

24 15 MAN I1BH l

-1.54

-1.29 F*1 16 22 H

25 15 SAD IBH

-1.49 0

F*1 17 22 H

13 16 MAI IBH

-0.6

-0.28 F*1 18 22 H

18 16 SAD IBH

-1.34 0

F*1 19 22 H

25 16 SAD 1BH

-1.07 0

F*1 20 22 H

27 16 SAD 1BH

-1.17 0

F*1 21 22 H

1 17 MAN 1BH

-2.22

-2.01 F*1 22 22 H

4 17 MAD 1BH

-1.3 0

F*1 23 22 H

14 17 SAD 1BH

-1.32 0

F*1 24 22 H

25 17 SAD 1BH

-1.4 0

F*1 25 22 H

1 18 MAN 1BH

-2.16

-2.05 F*1 26 22 H

2 18 MAN 1BH

-2.1

-2.03 F*1 27 22 H

4 18 MAD 1BH

-1.19 0

F*1 28 22 H

9 18 SAD 1BH

-1.45 0

F*1 29 22 H

14 18 MAD 1BH

-1.37 0

F*1 30 22 H

4 19 SAN 1BH

-2.18

-2.09 F*1 31 22 H

15 19 MAD 1BH

-1.08 0

F*1 32 22 H

1 20 MAN 1BH

-2.21

-2.05 F*1 33 22 H

3 20 SAN 1BH

-2.18

-2.11 F*1 34 22 H

12 20 MAI 1BH

-0.87

-0.12 F*1 35 22 H

14 20 SAD 1BH

-0.91 0

F*1 36 22 H

20 20 MAD 1BH

-1.4 0

F*1 37 22 H

24 20 MAI

_1BH

-0.91

-0.31 F*1 38 22 H

29 20 SAD 1BH

-1.47 0

F*1 39 22 H

1 21 MAN 1BH

-2.2

-2.07 F*1 40 22 H

4 21 MAN 1BH

-2.4

-2.3 F*1 41 22 H

10 21 SAD 1BH

-1.34 0

F*1 42 22 H

31 21 SAD 11BH -

-1.4 0

F*1 43 22 H

7 22 SAD 1BH

-1.27 0

F*1 44 22 H

18 22 SAN 1BH

-1.55

-1.48 F*1 45 22 H

23 22 SAD 1BH

-1.31 0

F*1 46 22 H

25 22 MAD 1BH

-1.3 0

F*1 32

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS - 15 DAY REPORT

'9 CT=AIfA tFKl0ATn2 P*l T IFC nInr.99 93nna No. S/G Leg Row Col Indication Location Elev from Elev to Status 47 22 H

28 22 SAD IBH

-1.47 0

F*1 48 22 H

32 22 MAI l1BH l -0.71

-0.14 F*1 49 22 H

33 22 SAD l1BH l -1.28 0

F*1l 50 22 H

22 23 SAN l1BH l -1.55

-1.44 F*1 51 22 H

26 231 SAN l1BH l -1.53

-1.5 F*l 52 22 H

32 23 SAD l1BH l -1.24 0

F*l 53 22 H

1 24 SAD IBH

-1.36 0

F*l 54 22 H

15 24 MAD IBH

-0.9 0

F*l 55 22 H

21 24 SAI 1BH

-0.7

-0.44 F*l 56 22 H

25 24 MAD 1BH

-1.37 0

F*l 57 22 H

27 24 MAD 1BH

-1.57 0

F*l 58 22 H

28 24 SAN 1BH

-1.35

-1.24 F*l 59 22 H

34 24 SAD 1BH

-1.02 0

F*l 60 22 H

35 24 SAD 1BH

-1.32 0

F*l 61 22 H

7 25 SAD 1BH

-1.31 0

F*1 62 22 H

14 25 SAD 1BH

-1.33 0

F*l 63 22 H

16 25 SAD 1BH

-1.27 0

F*l 64 22 H

19 25 SAD IBH

-1.24 0

F*l 65 22 H

20 25 MAD 1BH

-0.96 0

F*l 66 22 H

21 25 SAD 1BH

-1.51 0

F*l 67 22 H

23 25 MAN 1BH

-1.53

-1.37 F*l 68 22 H

26 25 SAN 1BH

-1.19

-1.12 F*l 69 22 H

28 25 MAI 1BH

-0.62

-0.3 F*l 70 22 H

31 25 SAD 1BH

-1 0

F*l 71 22 H

32 25 SAD 1BH

-1.4 0

F*l 72 22 H

33 25 SAD 1BH

-1 0

F*l 73 22 H

35 25 SAD 1BH

-1.56 0

F*l 74 22 H

1 26 SAN 1BH

-0.53

-0.34 F*l 75 22 H

18 26 SAD 1BH

-1.27 0

F*l 76 22 H

19 26 MAD 1BH

-1.67 0

F*l 77 22 H

21 26 SAD 1BH

-1.36 0

F*l 78 22 H

22 26 SAD 1BH

-1.56 0

F*l 79 22 H

24 26 MAD 1BH

-1.39 0

F*l 80 22 H

25 26 SAD 1BH

-1.31 0

F*l 81 22 H

27 26 SAD 11BH

-1.5 0

F*l 82 22 H

28 26 SAD IBH

-0.96 0

F*1 83 22 H

32 26 SAD 1BH

-1.3 0

F*l 84 22 H

33 26 SAD 1BH -

-1.33 0

F*l 85 22 H

13 27 MAD 1BH

-1.29 0

F*l 86 22 H

14 27 SAD 1BH

-0.95 0

F*l 87 22 H

15 27 SAD 1BH

-1.59 0

F*l 88 22 H

20 27 SAD 1BH

-1.52 0

F*l 89 22 H

24 27 SAD 1BH

-1.35 0

F*l 90 22 H

25 27 SAD IBH

-1.22 0

F*l 91 22 H

28 27 MAD IBH

-1.24 0

F*l 92 22 H

31 27 MAD IBH

-1.29 0

F*l 93 22 H

7 28 MAD I BH

-1.51 0

F*l 33

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 29 TEAM GEMERATO)P F*1 T IRF5 22 PflC.9 9AA3 No. S/G Lea Row Col Indication Location Elev from Elev to Status 94 22 H

20 28 SAD 1BH

-1.21 0

F*1 95 22 H

23 28 SAD 1BH

-1.34 0

F*l 96 22 H

31 28 SAD 1BH

-1.34 0

F*l 97 22 H

1 29 MAD IBH

-1.35 0

F*l 98 22 H

7 29 SAD IBH

-1.18 0

F*l 99 22 H

19 29 SAD 1BH

-1.72 0

F*l 100 22 H

24 29 SAD 1BH

-1.57 0

F*l 101 22 H

26 29 MAD 1BH

-1.44 0

F*1 102 22 H

27 29 MAD 1BH

-1.23 0

F*1 103 22 H

29 29 MAN 1BH

-0.78

-0.04 F*l 104 22 H

32 29 SAD 1BH

-1.52 0

F*l 105 22 H

5 30 SAN 1BH

-0.35

-0.17 F*l 106 22 H

9 30 SAD 1BH

-1.61 0

F*l 107 22 H

21 30 SAD BH

-1.29 0

F*l 108 22 H

32 30 MAD 1BH

-1.4 0

F*l 109 22 H

35 30 SAD BH

-1.4 0

F*1 110 22 H

3 31 MAN 1BH

-1.67

-1.2 F*1 111 22 H

4 31 SAN 1BH

-1.69

-1.55 F*l 112 22 H

27 31 SAD IBH

-1.25 0

F*l 113 22 H

28 31 SAD 1BH

-1.47 0

F*l 114 22 H

29 311 SAD IBH

-1.25 0

F*l 115 22 H

32 31 SAD IBH

-1.4 0

F*l 116 22 H

33 31 SAD IBH

-1.32 0

F*l 117 22 H

35 31 SAD BH

-1.53 0

F*l 118 22 H

1 32 MAD 1BH

-1.34 0

F*l 119 22 H

9 32 MAD 1BH

-1.18 0

F*l 120 22 H

20 32 MAN I1BH1

-1.36

-1.21 F*l 121 22 H

21 32 SAD IBH

-1.36 0

F*l 122 22 H

28 32 SAD 1BH

-1.17 0

F*1 123 22 H

31 32 SAN 1BH

-1.49

-1.33 F*l 124 22 H

32 32 SAD 1BH

-1.44 0

F*1 125 22 H

33 32 MAD IBH

-1.46 0

F*1 126 22 H

18 33 SAD 1BH

-1.41 0

F*1 127 22 H

23 33 SAD IBH

-1.53 0

F*1 128 22 H

25 33 SAD IBH

-0.9 0

F*l 129 22 H

32 33 MAD IBH

-1.49 0

F*l 130 22 H

33 33 SAD 1BH

-1 0

F*l 131 22 H

7 34 SAD IBH

-1.25 0

F*l 132 22 H

28 34 MAN 1BH

-1.52

-1.37 F*l 133 22 H

30 34 MAN 1BH

-1.61

-1.54 F*l 134 22 H

33 34 SAD BH

-0.97 0

F*l 135 22 H

3 35 SAD BH

-1.36 0

F*l 136 22 H

12 35 MAD BH

-1.21 0

F*l 137 22 H

13 35 MAN 1BH

-1.34

-1.12 F*l 138 22 H

22 35 SAD IBH

-0.9 0

F*l 139 22 H

28 35 MAN BH

-1.58

-1.27 F*1 140 22 H

29 35 SAD 1BH

-1.27 0

F*l 34

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT

=

=__ 22 STEAM GENERATOR F*l TUBES, BOC22,2003 No. SIG Leg Row Col Indication Location Elev from Elev to Status 141 22 H

30 35 SAN IBH

-1.43

-1.37 F*l 142 22 H

1 36 SAD 1BH

-1.3 0

F*l 143 22 H

7 36 SAD IBH

-1.35 0

F*l 144 22 H

20 36 MAD IBH

-1.47 0

F*l 145 22 H

23 36 MAN 1BH

-1.47

-1.24 F*1 146 22 H

27 36 SAD 1BH

-1.48 0

F*l 147 22 H

29 36 SAD IBH

-1.22 0

F*l 148 22 H

32 36 SAN IBH

-0.99

-0.81 F*l 149 22 H

33 36 SAD 1BH 1

-1.23 0

F*l 150 22 H

35 36 SAD IBH

-1.51 0

F*l 151 22 H

2 37 SAD 1BH

-1.25 0

F*l 152 22 H

20 37 SAD 1BH

-1.48 0

F*l 153 22 H

21 37 MAD 1BH

-1.23 0

F*l 154 22 H

23 37 SAD 1BH

-1.51 0

F1 155 22 H

24 37 SAN I1BH

-1.55

-1.42 F*l 156 22 H

30 37 SAD 1BH

-1.29 0

F 157 22 H

33 37 MAN 1BH

-0.51

-0.03 F*l 158 22 H

37 37 SAD 11BH -

-1.4 0

F*l 159 22 H

19 38 MAN IBH

-1.34

-1.21 F*l 160 22 H

33 38 MAI IBH

-0.75

-0.21 F*1 161 22 H

37 38 SAD IBH

-1.37 0

F*l 162 22 H

1 39 MAI IBH

-0.78

-0.15 F*l 163 22 H

3 39 SAD IBH

-1.41 0

F*l 164 22 H

9 39 SAD IBH

-1.5 0

F*l 165 22 H

20 39 SAD IBH

-1.11 0

F*l 166 22 H

23 39 SAD IBH

-1.5 0

F*l 167 22 H

33 39 SAD IBH

-1.31 0

F*l 168 22 H

37 39 SAD IBH

-1.33 0

F*l 169 22 H

1 40 MAD IBH

-1.34 0

F*l 170 22 H

12 40 SAD IBH

-1.03 0

F*l 171 22 H

20 40 SAD IBH

-1.41 0

Fl 172 22 H

21 40 SAD IBH

-1.36 0

F*l 173 22 H

22 40 MAD 1BH

-0.95 0

F*l 174 22 H

23 40 SAD 1BH

-1 0

F*l 175 22 H

32 40 SAD IBH

-1.52 0

F*l 176 22 H

33 40 SAD 1BH

-1 0

F*l 177 22 H

1 41 MAD 1BH

-1.63 0

F*1 178 22 H

19 41 SAD 1BH

-1.54 0

F*l 179 22 H

21 41 SAD 1BH

-1.58 0

F*l 180 22 H

22 41 SAD 1BH

-1.47 0

F*l 181 22 H

27 41 MAN 1BH

-1.53

-1.4 F*1 182 22 H

28 41 SAD 1BH

-0.92 0

F*l 183 22 H

29 41 SAD 1BH

-1.28 0

F*l 184 22 H

33 41 MAD 1BH

-1.41 0

F*l 185 22 H

37 41 MAD 1BH

-1.45 0

F*l 186 22 H

1 42 SAD 1BH

-1.35 0

F*l 187 22 H

2 42 SAD IBH

-1.32 0

F*l 35

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 22 STEAM GENERATOR F*1 TUBES, BOC22, 2003 No. SIG Le Row Cot Indication Location Elev from Elev to Status 188 22 H

13 42 SAD 1BH

-1.28 0

F*1 189 22 H

21 42 MAD 1BH

-0.95 0

F*1 190 22 H

22 42 SAD 1BH

-1.49 0

F*1 191 22 H

24 42 SAD 1BH

-1.71 0

F*1 192 22 H

29 42 SAD 1BH

-1.5 0

F*1 193 22 H

33 42 MAN 1BH

-1.49

-1.38 F*1 194 22 H

1 43 SAD 1BH

-1.63 0

F*1 195 22 H

3 43 SAD 1BH

-1.22 0

F*1 196 22 H

12 43 MAD 1BH

-1.17 0

F*1 197 22 H

13 43 SAD 1BH

-1.18 0

F*1 198 22 H

22 43 MAD 1BH

-1.44 0

F*1 199 22 H

33 43 MAN 1BH

-1.4

-1.27 F*1 200 22 H

37 43 SAN 1BH

-0.42

-0.26 F*1 201 22 H

13 44 MAN 1BH

-1.3

-1.17 F*1 202 22 H

14 44 SAD 1

BH

-1.58 0

F*1 203 22 H

17 44 SAN IBH

-1.2

-1.13 F*1 204 22 H

18 44 SAD IBH

-0.93 0

F*1 205 22 H

23 44 MAD IBH

-1.52 0

F*1 206 22 H

27 44 SAD IBH

-1.55 0

F*1 207 22 H

30 44 SAD IBH

-1.5 0

F*1 208 22 H

33 44 SAD IBH

-1.36 0

F*1 209 22 H

37 44 SAD IBH

-1.14 0

F*1 210 22 H

1 45 MAD IBH

-0.75 0

F*1 211 22 H

6 45 SAD IBH

-1.34 0

F*1 212 22 H

13 45 SAN IBH

-1.36

-1.2 F*1 213 22 H

15 45 MAD IBH

-1.52 0

F*1 214 22 H

19 45 MAD IBH

-0.9 0

F*1 215 22 H

28 45 MAD IBH

-1.57 0

F*1 216 22 H

29 45 SAD IBH

-1.4 0

F*1 217 22 H

10 46 SAD IBH

-1.18 0

F*1 218 22 H

12 46 SAD IBH

-1.38 0

F*1 219 22 H

14 46 SAD IBH

-1.2 0

F*1 220 22 H

16 46 MAD IBH

-1.35 0

F*1 221 22 H

17 46 SAN IBH

-1.02

-0.87 F*1 222 22 H

19 46 SAD IBH

-1.47 0

F*1 223 22 H

26 46 MAN IBH

-1.49

-1.29 F*1 224 22 H

1 47 SAD 1

BH

-1.19 0

F*1 225 22 H

6 47 SAD IBH

-1.29 0

F*1 226 22 H

12 47 SAD 1BH

-1.43 0

F*1 227 22 H

20 47 SAD IBH

-0.93 0

F*1 228 22 H

28 47 SAD IBH

-0.99 0

F 229 22 H

1 48 SAN IBH

-1.15

-1.02 F*l 230 22 H

2 48 MAN IBH

-1.14

-1.04 F*l 231 22 H

3 48 MAD IBH

-1.17 0

F*1 232 22 H

21 48 SAD IBH

-1 0

F*1 233 22 H

22 48 SAD IBH

-1.52 0

F*1 234 22 H

23 48 MAN IBH

-1.47

-1.19 F*l 36

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 22 STEAM GENERATOR F*l TUBES. BOC22. 2003 No. S/G Le Row Col Indication Location Elev from Elev to Status 235 22 H

28 48 MAN 11BH

-1.58

-1.23 F*l 236 22 H

29 48 SAD IBH

-1.59 0

F*1 237 22 H

37 48 SAD IBH

-1.43 0

F*l 238 22 H

1 49 SAN 1BH

-1.24

-1.17 F*l 239 22 H

4 49 SAD 1BH

-1.28 0

F*l 240 22 H

9 49 SAD IBH

-1.32 0

F*l 241 22 H

10 49 SAD IBH

-1.35 0

F*l 242 22 H

11 49 MAD 1BH

-1.36 0

F*l 243 22 H

12 49 SAN 1BH

-0.19

-0.01 F*l 244 22 H

13 49 SAD 1BH

-1.53 0

F*l 245 22 H

14 49 MAN 1BH

-1.27

-0.88 F*l 246 22 H

18 49 MAN 1BH

-1.35

-1.05 F*l 247 22 H

21 49 SAD 1BH

-0.86 0

F*l 248 22 H

23 49 MAN IBH

-1.52

-1.17 Ftl 249 22 H

27 49 SAD IBH

-1.15 0

F*l 250 22 H

28 49 SAN IBH

-1.48

-1.35 F*1 251 22 H

32 49 MAN IBH

-1.65

-1.26 F*1 252 22 H

40 49 SAD IBH

-1.19 0

F*l 253 22 H

41 49 SAN IBH

-1.29

-1.18 F*1 254 22 H

1 50 SAD IBH

-1.44 0

F*l 255 22 H

2 50 SAD IBH

-1.15 0

F*l 256 22 H

9 50 MAN 1BH

-1.01

-0.99 F*l 257 22 H

11 50 SAD 1BH

-1.18 0

F*l 258 22 H

15 50 SAD 1BH

-1.2 0

F*l 259 22 H

18 50 MAD 1BH

-0.94 0

F*l 260 22 H

22 50 SAD 1BH

-0.99 0

F*l 261 22 H

23 50 MAD 1BH

-0.97 0

F*l 262 22 H

24 50 MAN 1BH

-1.52

-1.29 F*l 263 22 H

25 50 SAN 1BH

-2.35

-2.28 F*l 264 22 H

27 50 MAD 1BH

-1.51 0

F*1 265 22 H

28 50 SAN 1BH

-1.46

-1.38 I F*l 266 22 H

29 50 SAD IBH

-1.6 0

F*l 267 22 H

30 50 SAD 1BH

-1.22 0

F*l 268 22 H

31 50 SAN IBH

-1.01

-0.93 F*l 269 22 H

32 50 MAN IBH

-1.53

-1.19 F*l 270 22 H

33 50 SAN 1BH

-1.5

-1.34 F*l 271 22 H

34 50 SAD IBH

-1.55 0

F*l 272 22 H

35 50 SAD 1BH

-1.56 0

F*l 273 22 H

1 51 SAD 1BH

-1.13 0

F*l 274 22 H

3 51 SAN IBH

-1.36

-1.12 F*l 275 22 H

9 51 MAD 1BH

-1.22 0

F*l 276 22 H

10 51 SAD 1BH

-1.19 0

F*l 277 22 H

12 51 SAD IBH

-1.17 0

F*1 278 22 H

13 51 MAD 1BH

-1.21 0

F*l 279 22 H

18 51 MAD 1BH

-1.37 0

F*l 280 22 H

21 51 SAD 1BH

-1.33 0

F*l 281 22 H

28 51 SAD 1BH

-1.47 0

F*l 37

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT

)) CTrCARA rcmcKATrD C*4 TI IrOCC onn" 3nnf r-I I

vlI A

La' Vru I IA V I

I JLJL-J, JL.,

&UJ.

No. S/G Leg Row Col Indication Location Elev from Elev to Status 282 22 H

32 51 SAN 1BH

-1.4

-1.3 F*l 283 22 H

37 51 SAD 1BH

-1.57 0

F*1 284 22 H

3 52 SAD 1BH

-1.35 0

F*1 285 22 H

7 52 SAD 1BH

-1.03 0

F*1 286 22 H

9 52 SAD 1BH

-1.15 0

F*1 287 22 H

20 52 SAD 1BH

-1.28 0

F*1 288 22 H

28 52 SAN 1BH

-1.37

-1.27 F*1 289 22 H

29 52 SAN 1BH

-1.46

-1.37 F*1 290 22 H

33 52 SAN 1BH

-1.44

-1.25 F*1 291 22 H

13 53 MAN 1BH

-1.37

-0.85 F*1 292 22 H

18 53 SAD 11BH

-1.33 0

F*1 293 22 H

24 53 SAD IBH

-1.46 0

F*1 294 22 H

25 53 SAN 1BH

-1.54

-1.39 F*1 295 22 H

29 53 MAD 1BH

-1.53 0

F*1 296 22 H

30 53 MAI 1BH

-0.73

-0.12 F*1 297 22 H

32 53 SAD 1BH

-1.35 0

F*1 298 22 H

33 53 SAD 1BH

-1.34 0

F*1 299 22 H

37 53 MAD 1BH

-0.93 0

F*1 300 22 H

40 53 MAI 1BH

-0.89

-0.32 F*1 301 22 H

1 54 MAN 1BH

-1.16

-0.92 F*1 302 22 H

9 54 MAD 1BH

-1.18 0

F*1 303 22 H

10 54 SAD IBH

-1.24 0

F*1 304 22 H

13 54 SAN 1BH

-1.35

-1.31 F*1 305 22 H

15 54 SAD 1BH

-1.07 0

F*1 306 22 H

16 54 MAN 1BH

-0.7

-0.15 F*i 307 22 H

18 54 MAD 1BH

-1.41 0

F*1 308 22 H

22 54 MAD 11BH

-1.28 0

F*1 309 22 H

23 54 SAN IBH

-1.43

-1.27 F*1 310 22 H

24 54 SAD 1BH

-1.46 0

F*1 311 22 H

25 54 SAD 1BH

-1.33 0

F*1 312 22 H

27 54 SAD 1BH

-1.45 0

F*1 313 22 H

28 54 MAI 1BH

-0.55

-0.08 F*1 314 22 H

34 54 SAD 1BH

-0.93 0

F*1 315 22 H

37 54 SAD 1BH

-1.41 0

F*1 316 22 H

1 55 SAN 1BH

-1.13

-0.93 F*1 317 22 H

9 55 SAD 1BH l -1.36 0

F*1 318 22 H

10 55 MAN 1BH

-1.21

-1.14 F*1 319 22 H

13 55 MAN 1BH

-1.31

-0.75 F*1 320 22 H

14 55 SAD 1BH

-1.2 0

F*1 321 22 H

19 55 MAD 1BH

-1.25 0

F*1 322 22 H

20 55 SAD 1BH

-1.23 0

F*1 323 22 H

21 55 MAD 1BH

-1.41 0

F*1 324 22 H

22 55 SAN 1BH

-1.34

-1.21 F*1 325 22 H

23 55 SAN 1BH

-1.38

-1.27 F*1 326 22 H

24 55 SAD 1BH

-1.53 0

F*1 327 22 H

29 55 SAD 1BH

-1.39 0

F*

328 22 H

32 55 SAD I1BH

-1.3 0

F*1 38

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS - 15 DAY REPORT 22 STEAM GENERATOR F*1 TUBES. B0C22. 2003 No.SIS/GL e Row Col Indication Location Elev from Elev to Status 329 22 H

33 55 SAN IBH

-1.5

-1.27 F*1 330 22 H

37 55 MAD IBH

-1.46 0

F*1 331 22 H

4 56 MAN 1I1BH l -1.25

-0.93 F*1 3321 22 H

6 56 SAD 1I1BH I -1.26 0

F*1 333 22 H

7 56 SAD 1BH

-1.36 0

F*1 334 22 H

9 56 SAD 1BH

-1.28 0

F*1 335 22 H

10 56 MAD 1BH

-1.2 0

F*1 336 22 H

11 56 MAD 1BH

-1.19 0

F*1 337 22 H

12 56 MAD 1BH

-1.24 0

F*1 338 22 H

13 56 SAD 1BH

-1.41 0

F*1 339 22 H

16 56 SAD IBH

-1.25 0

F*1 340 22 H

27 56 SAD 1BH

-1.6 0

F*1 341 22 H

28 56 SAD 1BH

-1.55 0

F*l 342 22 H

29 56 SAD IBH

-1.5 0

F*1 343 22 H

32 56 SAD 1BH

-1.28 0

F*l 344 22 H

3 57 SAN IBH

-1.32

-1.25 F*l 345 22 H

5 57 SAD 1BH

-1.37 0

F*1 346 22 H

7 57 SAN 1BH

-1.19

-1.09 F*l 347 22 H

10 57 SAD IBH

-1.24 0

F*l 348 22 H

13 57 MAD 1BH

-1.31 0

F*l 349 22 H

15 57 SAD 1BH

-1.06 0

F*l 350 22 H

18 57 MAD 1BH

-0.92 0

F*l 351 22 H

23 57 SAD 1BH

-1.51 0

F*l 352 22 H

25 57 SAD 1BH

-1.44 0

F*l 353 22 H

27 57 SAD 1BH

-1.37 0

F*1 354 22 H

28 57 MAD 1BH

-1.41 0

F*l 355 22 H

32 57 SAD 1BH

-1.28 0

F*l 356 22 H

34 57 SAD 1BH

-1.45 0

F*1 357 22 H

1 58 SAD 1BH

-1.3 0

F*1 358 22 H

3 58 SAD IBH

-1.27 0

F*l 359 22 H

7 58 MAN 1BH

-1.28

-1.21 F*l 360 22 H

14 58 SAD 1BH

-1.31 0

F*l 361 22 H

18 58 MAD IBH

-1.31 0

F*l 362 22 H

20 58 SAD 1BH

-1.4 0

F*l 363 22 H

23 58 SAN 1BH

-1.42

-1.24 F*l 364 22 H

24 58 SAD IBH

-1.51 0

F*l 365 22 H

37 58 SAN 1BH

-1.49

-1.34 F*1 366 22 H

4 59 SAD IBH

-1.26 0

F*l 367 22 H

5 59 SAD IBH

-1.42 0

F*1 368 22 H

9 59 SAD 1BH

-1.3 0

F*l 369 22 H

15 59 MAD 1BH

-1.34 0

F*l 370 22 H

16 59 MAD 1BH

-1.16 0

F*l 371 22 H

20 59 SAD 1BH

-1.43 0

F*l 372 22 H

22 59 SAN 1BH

-1.49

-1.41 F*l 373 22 H

23 59 SAN 1BH

-1.39

-1.31 F*l 374 22 H

24 59 SAD 1BH

-1.51 0

F*l 375 22 H

25 59 SAD I1BH

-1.4 0

F*l 39

~

~~~~~

I.

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS-15 DAY REPORT 22 STEAM GENERATOR F*i TUBES, BOC22,2003 No. S/G Le Row Col Indication Location Elev from Elev to Status 376 22 H

27 59 SAD 1BH

-1.41 0

F*1 377 22 H

28 59 MAN IBH

-1.48

-1.25 F*1 378 22 H

29 59 SAD IBH

-1.51 0

F*l 379 22 H

30 59 MAN IBH

-1.37

-1.3 F*l 380 22 H

34 59 SAD 1IBH

-1.39 0

F*l 381 22 H

5 60 SAD 1IBH

-1.35 0

F*l 382 22 H

6 60 SAD IBH

-1.34 0

F*l 383 22 H

7 60 SAD 1BH

-1.35 0

F*l 384 22 H 13 60 SAD 1BH

-1.43 0

F*l 385 22 H

15 60 SAD IBH

-1.26 0

F*l 386 22 H

18 60 SAD 1IBH

-1.42 0

F*l 387 22 H

19 60 MAD 1IBH

-1.41 0

F*l 388 22 H

23 60 SAD 1IBH

-1.48 0

F*l 389 22 H

27 60 SAD IBH

-1.26 0

F*l 390 22 H

32 60 SAN IBH

-1.47

-1.3 F*l 391 22 H

37 60 SAD IBH

-1.45 0

F*1 392 22 H

7 61 MAD IBH

-1.26 0

F*1 393 22 H

12 61 SAD IBH

-1.29 0

F*l 394 22 H

13 61 MAN 1BH

-1.54

-1.43 F*l 395 22 H

18 61 MAD IBH

-1.43 0

F*l 396 22 H

20 61 SAD 1BH

-1.35 0

F*l 397 22 H

22 61 MAN IBH

-1.37

-1.29 F*1 398 22 H

23 61 SAN IBH

-1.44

-1.34 F*l 399 22 H

25 61 SAD 1BH

-1.5 0

F*1 400 22 H

26 61 SAD 11BH

-1.14 0

F*l 401 22 H

27 61 MAN 1BH

-0.58

-0.27 F*1 402 22 H

32 61 SAD 1BH

-1.47 0

F*l 403 22 H

5 62 MAD 1BH

-1.62 0

F*l 404 22 H

7 62 SAD 1BH

-1.23 0

F*l 405 22 H

10 62 SAD 1BH

-1.38 0

F*1 406 22 H

12 62 SAD IBH

-1.42 0

F*1 407 22 H

13 62 MAD IBH

-1.26 0

F*l 408 22 H

16 62 MAD 1BH

-1.17 0

F*l 409 22 H

18 62 SAD IBH

-1.34 0

F*1 410 22 H

19 62 MAN IBH

-1.28

-0.99 F*1 411 22 H

23 62 MAD 1BH

-1.55 0

F*l 412 22 H

24 62 SAD 1BH

-1.36 0

F*l 413 22 H

25 62 SAN 1BH

-0.7

-0.38 F*l 414 22 H

29 62 SAD 1BH

-1.16 0

F*l 415 22 H

34 62 SAD IBH

-1.46 0

Fl 416 22 H

37 62 SAN 1BH

-1.44

-1.24 F*l 417 22 H

42 62 MAI IBH

-0.73

-0.38 F*l 418 22 H

1 63 SAD 1BH

-1.24 0

F*l 419 22 H

7 63 SAD IBH

-1.19 0

F*l 420 22 H

11 63 SAD 1BH

-1.3 0

F*1 421 22 H

12 63 SAD IBH

-1.41 0

F 422 22 H

23 63 SAD IBH

-1.16 0

F 40

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 22 STEAM GENERATOR F*l TUBES, BOC22, 2003 No. S/G Leg Row Col Indication Location Elev from Elev to Status 423 22 H

24 63 SAD IBH

-1.38 0

F*1 424 22 H

25 63 SAN l1BH l

-1.59

-1.5 F*1 425 22 H

33 63 SAD l1BH l

-1.52 0

F*1 426 22 H

37 63 SAN l1BH l

-1.39

-1.36 F*1 427 22 H

1 641 SAD IBH

-1.21 0

F*1 428 22 H

2 64 SAD IBH

-1.26 0

F*1 429 22 H

4 64 SAD 1BH l

-1.14 0

F*1 430 22 H

7 64 SAN IBH

-1.62

-1.52 F*1 431 22 H

9 64 SAN IBH

-1.23

-1.1 F*1 432 22 H

18 64 SAD IBH

-1.3 0

F*1 433 22 H

19 64 MAD 1BH

-1.26 0

F*1 434 22 H

32 64 MAD 1BH

-1.5 0

F*1 435 22 H

34 64 MAN 1BH

-1.42

-1.29 F*1 436 22 H

37 64 SAD 1BH

-1.18 0

F*1 437 22 H

6 65 MAD 1BH

-1.27 0

F*1 438 22 H

8 65 SAD 1BH

-1.18 0

F*1 439 22 H

10 65 MAN 1BH

-1.22

-1.15 F*1 440 22 H

11 65 SAD IBH

-1.33 0

F*1 441 22 H

12 65 MAN 11BH

-1.31

-1.22 F*1 442 22 H

15 65 MAN IBH

-1.18

-1.08 F*1 443 22 H

19 65 SAD IBH

-1.29 0

F*1 444 22 H

24 65 MAN IBH

-1.38

-1.3 F*1 445 22 H

26 65 SAD 1BH

-1.26 0

F*1 446 22 H

27 65 SAN IBH

-1.4

-1.36 F*1 447 22 H

33 65 SAD 1BH

-1.49 0

F*1 448 22 H

34 65 SAD 1BH

-1.23 0

F*1 449 22 H

36 65 SAD 1BH

-1.56 0

F*1 450 22 H

37 65 SAD 1BH

-1.28 0

F*1 451 22 H

9 66 SAD IBH

-1.15 0

F*1 452 22 H

11 66 MAN 1BH

-1.29

-1.03 F*1 453 22 H

12 66 MAD IBH

-1.5 0

F*1 454 22 H

13 66 SAD IBH

-1.28 0

F*l 455 22 H

20 66 MAD IBH

-1.27 0

F*l 456 22 H

21 66 MAD IBH

-1.03 0

F*l 457 22 H

22 66 SAD IBH

-1.47 0

F*l 458 22 H

24 66 SAN IBH

-1.35

-1.28 F*l 459 22 H

31 66 SAD IBH

-1.5 0

F*l 460 22 H

37 66 SAN 1BH

-1.37

-1.24 F*l 461 22 H

7 67 SAD 1BH

-1.31 0

F*l 462 22 H

9 67 MAN IBH

-1.13

-1.03 F*1 463 22 H

16 67 SAN 1BH

-1.16

-1.09 F*l 464 22 H

17 67 SAD IBH

-1.39 0

F*l 465 22 H

20 67 SAD IBH

-1.27 0

F*l 466 22 H

24 67 MAN 1BH

-1.46

-1.33 F*l 467 22 H

27 67 MAN IBH

-1.57

-1.32 F*1 468 22 H

30 67 SAN IBH

-1.57

-1.54 F*1 469 22 H

31 67 SAD I1 BH

-1 0

F*l 41

2003 UNIT:2STEM R

II 2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 22 STEAM GENERATOR F*l TUBES, BOC22, 2003 No. S/G -g Row Col Indication Location Elev from Elev to Status 470 22 H

32 67 SAD 1BH

-1.22 0

F*l 471 22 H

34 67 SAD 1BH

-1.48 0

F*l 472 22 H

37 67 SAN 1BH

-1.56

-1.43 F*l 473 22 H

9 68 SAD 1BH

-1.59 0

F*l 474 22 H

10 68 SAD IBH

-1.24 0

F*l 475 22 H

13 68 SAD 1BH

-1.17 0

F*l 476 22 H

21 68 MAD IBH

-1.33 0

F*l 477 22 H

24 68 MAN 1BH

-1.36

-1.25 F*l 478 22 H

27 68 SAN 1BH

-1.48

-1.38 F*l 479 22 H

31 68 SAD 1BH

-0.9 0

F*l 480 22 H

32 68 SAD 1BH

-1.32 0

F*l 481 22 H

33 68 SAD 1BH

-1.27 0

F*l 482 22 H

37 68 MAN 1BH

-1.5

-1.37 F*l 483 22 H

9 69 SAD 1BH

-1.34 0

F*l 484 22 H

15 69 MAD 1BH

-0.94 0

F*l 485 22 H

16 69 MAD IBH

-1.3 0

F*l 486 22 H

25 69 MAN IBH

-1.32

-1.25 F*l 487 22 H

27 69 SAD 1BH

-1.51 0

F*l 488 22 H

31 69 SAD 1BH

-1.46 0

F*l 489 22 H

32 69 SAD 1BH

-1.15 0

F*l 490 22 H

37 69 SAD 11BH

-1.43 0

F*l 491 22 H

11 70 SAD 1BH

-0.95 0

F*l 492 22 H

21 70 SAD IBH

-1.47 0

F*l 493 22 H

22 70 SAD IBH

-1.19 0

F*l 494 22 H

23 70 SAD IBH

-1.14 0

F*1 495 22 H

24 70 SAD IBH

-1.57 0

F*l 496 22 H

27 70 SAN 1BH

-1.38

-1.29 F*l 497 22 H

31 70 MAN IBH

-0.47

-0.34 F*1 498 22 H

12 71 MAD 1BH

-1.11 0

F 499 22 H

14 71 SAD 1BH

-1.36 0

F*l 500 22 H

17 71 MAD 1BH

-1.35 0

F*l 501 22 H

18 71 SAD 1BH

-1.28 0

F*1 502 22 H

20 71 SAD IBH

-1.29 0

F*l 503 22 H

22 71 MAD IBH

-1.24 0

F*l 504 22 H

23 71 MAD IBH

-1.42 0

F*l 505 22 H

26 71 MAI IBH

-0.46

-0.11 F*1 506 22 H

27 71 SAD IBH

-0.9 0

F*1 507 22 H

32 71 SAD IBH

-1.17 0

F*l 508 22 H

8 72 SAD IBH

-1.28 0

F*l 509 22 H

9 72 MAD IBH

-1.2 0

F*l 510 22 H

11 72 MAN 1BH

-1.41

-1.28 F*l 511 22 H

12 72 MAN 1BH

-1.22

-1.12 F*1 512 22 H

13 72 SAD 1BH

-1.37 0

F*l 513 22 H

16 72 SAD 1BH

-1.4 0

F*l 514 22 H

17 72 SAD 1BH

-1.26 0

F*l 515 22 H

24 72 SAN 1BH

-0.47

-0.15 F1 516 22 H

27 72 MAD I BH

-1.32 0

F1 42

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 22 STEAM GENERATOR F*l TUBES. BOC22. 2003 No. S/G _ Row Coi Indication Location Elev from Elev to Status 517 22 H

9 73 SAD IBH

-1.27 0

F*1 518 22 H

12 73 MAN IBH

-1.12

-1.04 F*l 519 22 H

13 73 MAN IBH

-1.39

-1.3 F*l 520 22 H

14 73 MAD IBH

-1.13 0

F*l 521 22 H

15 73 MAN IBH

-1.16

-1.06 F*l 522 22 H

16 73 MAI 1BH

-0.48

-0.02 F*l 523 22 H

17 73 MAD IBH

-1.3 0

F*l 524 22 H

18 73 SAD 1BH

-1.3 0

F*1 525 22 H

19 73 SAD 1BH

-1.22 0

F*l 526 22 H

25 73 SAD IBH

-1.49 0

F*l 527 22 H

12 74 MAN IBH

-0.56

-0.38 F*1 528 22 H

14 74 MAD IBH

-1.34 0

F*1 529 22 H

15 74 MAD IBH

-1.29 0

F*1 530 22 H

17 74 MAN 1BH

-0.75

-0.24 F*l 531 22 H

18 74 SAI IBH

-0.62

-0.33 F*1 532 22 H

24 74 SAD IBH

-1.54 0

F*1 533 22 H

4 75 SAD IBH

-1.39 0

F*1 534 22 H

10 75 MAD IBH

-1.24 0

F*l 535 22 H

12 75 MAD 1BH

-1.22 0

F*l 536 22 H

13 75 SAN 1BH

-1.2

-1.04 F*l 537 22 H

14 75 MAD 1BH

-1.33 0

F*l 538 22 H

15 75 MAD 1BH

-1.3 0

F*l 539 22 H

27 75 MAD IBH

-0.9 0

F*1 540 22 H

8 76 SAD IBH

-1.29 0

F*l 541 22 H

11 76 MAN IBH

-1.09

-0.96 F*l 542 22 H

13 76 SAD IBH

-1.48 0

F*l 543 22 H

17 76 MAD IBH

-1.13 0

F*l 544 22 H

18 76 SAD IBH

-1.42 0

F*l 545 22 H

20 76 SAD IBH

-1.38 0

F*l 546 22 H

22 76 SAN 1BH

-0.71

-0.12 F*l 547 22 H

26 76 MAD 1BH

-1.5 0

F*l 548 22 H

8 77 SAD 1BH

-1.26 0

F*1 549 22 H

11 77 SAD IBH

-1.39 0

F*1 550 22 H

12 77 MAD IBH

-1.49 0

F*l 551 22 H

13 77 SAN IBH

-1.23

-1.13 F*l 552 22 H

14 77 SAI 1BH

-0.45

-0.15 F*l 553 22 H

15 77 SAD IBH

-1.33 0

F*l 554 22 H

16 77 MAD 1BH

-1.27 0

F*l 555 22 H

17 77 MAD IBH

-1.1 0

F*l 556 22 H

18 77 MAD 1BH

-1.43 0

F*l 557 22 H

22 77 SAN IBH

-1.31

-1.23 F*l 558 22 H

25 77 SAD 1BH

-0.94 0

F*1 559 22 H

11 78 SAD 1BH

-1.36 0

F*1 560 22 H

12 78 SAD 1BH

-0.95 0

F*l 561 22 H

17 78 SAD 1BH

-1.4 0

F*l 562 22 H

18 78 SAD 1BH

-1.38 0

F*l 563 22 H

22 78 SAD iBH

-1.53 0

Fl 43

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 22 STEAM GENERATOR F*1 TUBES. BOC22. 2003 No. SIG Leg Row Col Indication Location Elev from Eev to Status 564 22 H

26 78 MAN IBH

-1.13

-1.03 F*1 565 22 H

12 79 SAN IBH

-0.53

-0.21 F*l 566 22 H

13 79 MAN 1BH

-1.22

-1.14 F*l 567 22 H

14 79 MAN 1BH

-1.11

-1 F

568 22 H

15 79 MAD 1BH

-1.29 0

F*1 569 22 H

17 79 MAD 1BH

-1.12 0

F*1 570 22 H

19 79 SAD 1BH

-1.2 0

F*l 571 22 H

22 79 SAD 1BH

-1.31 0

F*l 572 22 H

25 79 SAD 1BH

-1.36 0

F*l 573 22 H

26 79 SAD 1BH

-1.49 0

F*l 574 22 H

9 80 MAN 1BH

-1.31

-1.02 F*1 575 22 H

10 80 MAD 1BH

-1.36 0

F*1 576 22 H

12 80 MAD IBH

-1.36 0

F*l 577 22 H

13 80 MAN IBH

-1.22

-0.92 F*l 578 22 H

15 80 SAD IBH

-1.32 0

F*l 579 22 H

23 80 SAD IBH

-1.4 0

F*1 580 22 H

9 81 MAD IBH

-1.3 0

F*1 581 22 H

12 81 SAD IBH

-0.88 0

F*1 582 22 H

13 81 SAD IBH

-1.38 0

F*l 583 22 H

15 81 MAD IBH

-0.94 0

F*l 584 22 H

18 81 SAD 1BH

-1.26 0

F*l 585 22 H

22 81 SAN 1BH

-1.3

-1.23 F*l 586 22 H

12 82 SAD BH

-1.3 0

F*l 587 22 H

13 82 MAD 1BH

-1 0

F*l 588 22 H

17 82 MAD 1BH

-1.3 0

F*l 589 22 H

15 83 SAD 1BH

-0.9 0

F*l 590 22 H

17 83 SAD IBH

-0.86 0

F*l 591 22 H

22 83 SAD 1BH

-1.44 0

F*l 592 22 H

10 84 SAD IBH

-1.48 0

F*l 593 22 H

15 84 SAD IBH

-1.48 0

F*l 594 22 H

18 84 MAD IBH

-0.92 0

F*l 595 22 H

12 85 SAD IBH

-1.45 0

F*l 596 22 H

15 85 SAD IBH

-1.25 0

F*1 597 22 H

13 86 SAD IBH

-1.32 0

F*1 598 22 H

17 87 SAD IBH

-1.42 0

F 22 STEAM GENERATOR F*2 TUBES, BOC22, 2003 No. S/G Leg RowlCol Indication Location Elev from Elev to Status 1 22 H

18 20 MAN 2BH T -2.47

-1.62 F*2 2

22 H

18 21 SAD 2BH

-2.71 0

F*2 3

22 H

21 22 SAD 2BH l

-3.51 0

F*2 4

22 H

16 23 MAN 2BH l -2.34

-1.79 F*2 5

22 H

17 28 SAD 2BH T -2.12 0

F*2 6

22 H

20 29 SAD 2BH T -3.16 0

F*2 7

22 H

27 30 SAN 2BH T -1.93 l -1.73 F*2 I 8

22 H

15 31 SAD 2BH T -0.31 0

F*2 9

22 H

22 341 MAN 2BH

-2.09

-1.52 F*2 44

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 22 STEAM GENERATOR F*2 TUBES, BOC22, 2003 No. SIG Lea Row Col Indication Location Elev from Elev to Status 10 22 H

14 35 SAN 2BH

-3.06

-2.99 F*2 11 22 H

19 35 SAD 2BH

-3.18 0

F*2 12 22 H

37 35 SAD 2BH

-0.88 0

F*2 13 22 H

19 36 SAD 2BH

-3.32 0

F*2 14 22 H

12 37 SAN 2BH

-3.33

-3.28 F*2 15 22 H

18 39 SAD 2BH

-3.16 0

F*2 16 22 H

19 39 SAD 2BH

-3.21 0

F*2 17 22 H

14 40 SAN 2BH

-1.1

-0.89 F*2 18 22 H

5 41 MAN 2BH

-2.35

-1.83 F*2 19 22 H

13 41 MAD 2BH

-3.52 0

F*2 20 22 H

12 42 SAN 2BH

-0.75

-0.64 F*2 21 22 H

15 43 SAN 2BH

-2.04

-1.96 F*2 22 22 H

1 44 MAD 2BH

-3.24 0

F*2 23 22 H

16 44 SAD 2BH

-3.4 0

F*2 24 22 H

17 45 MAN 2BH

-3.27

-2.85 F*2 25 22 H

37 45 SAD 2BH

-3.48 0

F*2 26 22 H

15 46 MAD 2BH

-3.28 0

F*2 27 22 H

23 46 SAD 2BH

-3.38 0

F*2 28 22 H

18 47 MAD 2BH

-3.37 0

F*2 29 22 H

21 47 SAD 2BH

-3.2 0

F*2 30 22 H

18 48 SAD 2BH

-2.96 0

F*2 31 22 H

27 48 SAD 2BH

-3.08 0

F*2 32 22 H

3 49 SAN 2BH

-0.74

-0.64 F*2 33 22 H

26 50 MAD 2BH

-3.14 0

F*2 34 22 H

11 51 SAD 2BH

-3.16 0

F*2 35 22 H

18 52 SAD 2BH

-3.1 0

F*2 36 22 H

24 52 MAN 2BH

-3.2

-3 F*2 37 22 H

10 53 MAD 2BH

-3.29 0

F*2 38 22 H

12 53 SAN 2BH

-2.99

-2.88 F*2 39 22 H

16 53 SAD 2BH

-3.48 0

F*2 40 22 H

17 53 MAN 2BH

-1.75

-1.65 F*2 41 22 H

20 53 MAD 2BH

-3.16 0

F*2 42 22 H

15 56 SAN 2BH

-0.47

-0.43 F*2 43 22 H

20 56 SAN 2BH

-3.3

-3.21 F*2 44 22 H

37 56 SAD 2BH

-3 0

F*2 45 22 H

21 57 MAN 2BH

-1.06

-0.99 F*2 46 22 H

2 58 SAN 2BH

-3.24

-3.2 F*2 47 22 H

13 58 SAN 2BH

-0.55

-0.43 F*2 48 22 H

9 60 SAN 2BH

-1.52

-1.25 F*2 49 22 H

20 60 SAD 2BH

-3.25 0

F*2 50 22 H

16 65 MAD 2BH

-3.04 0

F*2 51 22 H

24 69 SAN 2BH

-0.87

-0.81 F*2 52 22 H

32 70 MAN 2BH

-2.58

-1.94 F*2 53 22 H

19 74 SAN 2BH

-2.03

-1.87 F*2 54 22 H

22 75 MAN 2BH

-2.64

-1.81 F*2 55 22 H

23 78 MAN 2BH

-2.7

-2.11 F*2 56 22 H

17 80 SAN 2BH

-0.94

-0.62 F*2 45

2003 UNIT 2 STEAM GENERATOR INSPECTION RESULTS -15 DAY REPORT 22 STEAM GENERATOR F*2 TUBES, BOC22, 2003 No. S/G Leg Row Col Indication Location Elev from Elev to Status 57 22 H

26 81 SAN 2BH

-2.36

-1.89 FP2 58 22 H

15 86 MAN 2BH

-2.57

-1.96 F*2 59 22 H

14 88 MAN 2BH

-2.64

-1.86 F*2 46