Signed Consent to the Proposed Minor Modification of Ohio EPA Permit No. 31B00016*GD
ML032820359
Person / Time
Site: Perry FirstEnergy icon.png
Issue date: 09/25/2003
From: Kanda W
FirstEnergy Nuclear Operating Co
To:
Office of Nuclear Reactor Regulation, State of OH, Environmental Protection Agency
References
31B00016*ED, PY-CEI/OEPA-0406L
Download: ML032820359 (4)


Text

FENOC RrselayMebar QemrQ Cwwy Perry Nuclear Power Plant 10 Center Road fny Ohio 4408i VNilam R Kanda Vice President -Nuclear September 25, 2003 PY-CEIIOEPA-0406L Ohio Environmental Protection Agency Division of Surface Water Permit Administration Section P.O. Box 1049 Columbus, Ohio 43216-1049 e

Ladies and Gentlemen:

Enclosed is the signed consent to the proposed minor modification of Ohio EPA Permit No. 31B00016*GD and the referenced pages.

If you have questions or require additional information, please contact Mr. Leo Harte at (440) 280-5514.

Very truly yours, 440-280-579 Far 440-280-8029 Enclosures cc: NRC Region m NRC Resident Inspector NRC Project Manager NRC Document Control Desk (Docket No. 50-440) c(z¶A,

State of Ohio Environmental Protection Agency STRMEADXRESS:

lIUUUNGADDRESS-STREETADORESS:

SWUNG ADDRFSS:

Lazarus Government Center 122 S. Front Street Columbus, Ohio 43215 September 5, 2003 TELE: (614) 644-3020 FAX: (14) 644-3184 P.O. Box 1049 Columbus, OH 43216-1049 Re:

Ohio EPA Permit No. 31B00016*GD Cleveland Electric Illuminating Company Perry Nuclear Power Plant 10 Center Road Perry, Ohio 44081 Ladies and Gentlemen:

We propose to make to following minor modifications to the above referenced permit.

Paae Correction 4

Change measuring frequency from 1/Day" to When Discharging' for Total Residual Oxidents (reporting code 34044), Chlorine, Free Available (reporting code 50064), and Bromination Duration/Chlorination (reporting code 78739).

6 Change measuring frequency from 1/Day" to When Discharging" for Total Residual Oxidents (reporting code 34044), Chlorine, Free Available (reporting cpde 50064), and Bromination Duration/Chlorination (reporting code 78739).

If you consent to these changes, please sign below and Incorporate the corrected pages Into your permit.

The proposed minor modifications will become effective on the date we receive this signed letter from you at the following address: Ohio Environmental Protection Agency, Division of Surface Water, Permit Administration Section, P. O. Box 1049, Columbus, Ohio 43266-0149.

cerely,

.~x d. SC Patti L. Smith, Supervisor Permit Processing Unit Division of Surface Water PLS/dks Enclosure CERTIFIED MAIL I consent to the minor modificaion Name

-Y5

ile, A4

-AA Date Bob Taft, Governor Jennette Bradley, Lieutenant Governor Christopher Jones, Director E

Pd on Rcyded Paper Ohio EPA is an Equal Opportunity Employer

i Page 6 E

~~~3EB00016*GD Part I, A. - FINAL EFFLUENT LIMITATION' AND MONITORING REQUIREMENTS D

1. During the period beginning 24 months the e~fective date of this permit and lasting until the expiration date, the permittee is authorized to discharge in accordance with the following limitations and monitoring requirements from outfall 31B00016004. See Part II, OTHER REQUIREMENTS, for locations of effluent sampling.

Table - Final Outfall - 004 - Final Effluent Characteristicl Dischare Limitations Monitoring Reauirements Concentration Specified Units Loading* kg/day Measuring Sampling Monitoring Parameter Maximum 4inimum Weekly Monthly Daily Weekly Monthly Frequency Type Months 00011 - Water Temperature - F 1Day Continuous All 00400 - pH -S.U.

9.0 6.5 2/Week Grab All 01119 - Copper, Total Recoverable - ugt 1/Month Grab All 34044 - Oxidants, Total Residual - mg/I 0.05 When Disch. Grab All 50050 - Flow Rate - MGD I/Day Continuous All 50060 - Chlorine, Total Residual - mg/I 0.2 Whei Disch. Grab All 78739 - Chlorination/Bromination Duration 120 When Disch. Total All

- Minutes Notes for Station Number 31B000 16004:

  • The Total Residual Chlorine (TRC) and Total Residual Oxidants (TRO) limits are the maximum allowed at the outfall at any time.

Analyses are to be performed by amperometric titration, Orion Residual Chlorine Electrode, or other approved methods during chlorination and /or bromination. The daily grab samples for TRC and TRO shall represent the maximum concentration discharged during chlorination and/or bromination.

    • Measure TRO, TRC and Cl/Br duration on days when using treatment.
        • Total Residual Chlorine or Total Residual Oxidants may not be discharged from any single generating unit for more than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> per day.

(1) Total Residual Oxidants reflects the use of bromine compounds. Bromine canbe used separately or in combination with chlorine. These limits are effective when bromine is used. Discharge limitations for TRO may be met using a dehalogenation agent, if necessary.

Dehalogenation shall be achieved by using stoichiometric calculations to determine the amount of dehalogenating agent necessary to completely eliminate the residual.

I

I Page 4 3EB00016*GD Part I, A. - INTERIM EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS

1. During the period beginning on the effective date of this permit and lasting until 24 months after the Effective date, the permittee is authorized to discharge in accordance with the following limitations and monitoring requirements from outfall 3IB00016004. See Part II, OTHER REQUIREMENTS, for locations of eftluent sampling.

l Table - Final Outfall - 004 - Interim Effluent Characteristiy Discharge Limitations Monitoring Requirements Concentration Specified Units Maximum Minimum Weekly Monthly Loading* kg/day Daily Weekly Monthly Parameter Mdasuring Frequency i/Day Grab Sampling Type Monitoring Months 00011 - Water Temperature - F 00400 - pH - S.U.

01119 - Copper, Total Recoverable - ug/l 34044 - Oxidants, Total Residual - mg/I 50050 - Flow Rate - MGD 9.0 6.5 0.05 2>'Week Grab 1/Month Grab Whin Disch. Grab IDay Continuous When Disch. Grab When Disch. Total All All All AUl All All All 50064 - Chlorine, Free Available - mg/I 0.5 0.2 78739 - Chlorination/Bromination Duration 120

- Minutes Notes for Station Number 31B0001 6004:

  • The Free Available Chlorine (FAC) and Total Residual Oxidants (TRO) limits are the maximum allo*ed at the outfall at any time.

Analyses are to be performed by amperometric titration, Orion Residual Chlorine Electrode, or other approved methods during chlorination and /or bromination. The daily grab samples for FAC and TRO shall represent the maximum concentration discharged during chlorination and/or bromination.

    • Measure TRO, FAC and Cl/Br duration on days when using treatment.
        • Free Available Chlorine or Total Residual Oxidants may not be discharged from any single generating unit for more than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> per day.

(I) Total Residual Oxidants reflects the use of bromine compounds. Bromine can be used separately or in combination with chlorine. These limits are effective when bromine is used. Discharge limitations for TRO may be met using a dehalogenation agent, if necessary.

Dehalogenation shall be achieved by using stoichiometric calculations to determine the amount of dehalogenating agent necessary to completely eliminate the residual.