ML032730561
| ML032730561 | |
| Person / Time | |
|---|---|
| Site: | Susquehanna |
| Issue date: | 09/17/2003 |
| From: | Susquehanna |
| To: | Document Control Desk, Office of Nuclear Security and Incident Response |
| References | |
| Download: ML032730561 (3) | |
Text
_
Sep. 17, 2003 Page 1
of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2003-42392 USER INFORMATION:
G
~ACH*ROS EMPL#:28401 CA#: 0363 Addre UCSA2 Pho 2
94 TRANSMITTAL INFORMATION:
TO:
nnr.0.9..
09/17/2003 LOCATION: f7UGCUMENT CONTROL DESK FROM:
NUCLEAR RECORDS DOCUMENT CONTROL CENTER
'NUCSA-2)
'<>?HE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU:
354 -
354 -
MEDIA OPERATIONS CENTER (MOC)
COMMUNICATOR REMOVE MANUAL TABLE OF CONTENTS DATE: 07/30/2003 ADD MANUAL TABLE OF CONTENTS DATE: 09/16/2003 CATEGORY: PROCEDURES TYPE: EP ID:
EP-PS-354 REPLACE:
REV:4 REPLACE:
REV:4 REMOVE: PCAF 2003-1547 REV: N/A ADD: PCAF 2003-1547 REV: N/A UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.
PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY. FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
S5~4
cN Tab 6 EP-PS-354-6 Affected Unit Control No.
PROTECTIVE ACTION RECOMMENDATION FORM SUSQUEHANNA STEAM ELECTRIC STATION 3 This is a Drill O This is NOT a Drill Preparer:
The EMERGENCY CLASSIFICATION Is:
D Unusual Event O3 Alert O3 Site Area Emergency O3 General Emergency Basis: EAL #
This represents:
0 Initial Classification 3 Escalation 0 Reduction 0 No Change in the Classification Status Emergency Action(s) Implemented onsite:
O None O Local Area Evacuation O Site Accountability Bases:
.0 Evacuation of non-essential personnel 0 KI to onsite personnel 0 Other The PROTECTIVE ACTION RECOMMENDATION Is:
o No Protective Action Recommendation Required O Evacuate 0-2 miles and Shelter 2-10 miles 03 Relocation O Evacuate 0-10 miles 10 Control of Access I 0 Contamination Controls/Decon O Divert Danville Drinking Water*
0 Other
- Expected arrival of release at Danville:
This represents:
0 Initial 03 Change 0 No Change in the Protective Action Recommendation EP-AD-000-1 10, Revision 10, Page 1 of 2 (DUPLEX)
4 Tab 6 EP-PS-354-6 The BASIS for the Protective Action Recommendation is:
Plant Status Status of Radioactive Release: Event-related release In progress? 0 Yes 0 No Total Site Release Rate Airborne Liquid
< Tech Requirements Limit I3 O0
Ž Tech Requirements Limit 3
NOTE:
TRM Limits (Cimin): Noble Gas 1.OOE+6; Iodine 1.04E+2; Particulate 7.72 E+2 (Airborne releases)
Based on:
Effluent Monitors 0 Field Measurements 3 Engineering Judgement Data measured In the field confirm release rate estimations: 0 Yes 0 No 0 WA Weather Conditions:
Wind Speed Wind Direction__
Dose Projections:
TEDE >- 1 rem or thyroid CDE > 5 rem at 2 miles 0 TEDE > 1 rem or thyroid CDE > 5 rem at EPB I
3TEDE<1 rem and thyroid CDE <5 rem atEPB -
Other:
Approval:
DateMme:
Emergency Director or Recovery Manager approval required if change in Classification or Protective Action Recommendation.
RPC or DASU approval if no change in the Classffication or Protective Action Recommendation.
Transmittal:
0 Verbal 0 Electronic 0 Both Communicated To: