Text
Exekon.
Exelon Generation Company, LLC www.exeloncorp.com Nuclear LaSalle County Station 2601 North 21'Road Marseilles, IL 61341-9757 September 15, 2003 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 LaSalle County Station, Units 1 and 2 Facility Operating License Nos. NPF-11 and NPF-18 NRC Docket Nos. 50-373 and 50-374
Subject:
Monthly Operating Report for August 2003 Enclosed is the Exelon Generation Company (EGC), LLC, Monthly Operating Report for LaSalle County Station covering the period from August 1 through August 31, 2003. This report is submitted in accordance with Technical Specification 5.6.4.
Should you have any questions concerning this letter, please contact Mr. Glen T. Kaegi, Regulatory Assurance Manager, at (815) 415-2800.
Respectfully, so Ed; Glen T. Kaegi Regulatory Assurance Manager LaSalle County Station Enclosure cc:
Regional Administrator - NRC Region IlIl NRC Senior Resident Inspector - LaSalle County Station
- 1.
Monthly Report for LaSalle County Station Unit One-August 2003 A.
OPERATING DATA
SUMMARY
FOR UNIT ONE DOCKET NO.:
UNIT:
DATE:
COMPLETED BY:
TELEPHONE:
50-373 LaSalle One September 9, 2003 S. Du Pont (815) 415-2197
- 1.
Reporting Period: August 2003
- 2.
Currently Authorized Power Level: 3489 (MWt)
Design Electrical Rating: 1154 (MWe-net)
Max Dependable Capacity: 1111 (MWe-net)
- 3.
Power Level To Which Restricted (If Any): None
- 4.
Reasons For Restriction (If Any): N/A THIS MONTH YEAR-TO-DATE CUMULATIVE
- 5.
Reactor Critical Hours 744.0 5831.0 121476.2
- 6.
Reactor Reserve 0.0 0.0 1641.2 Shutdown Hours
- 7.
Hours Generator 744.0 5831.0 119247.9 On-Line
- 8.
Unit Reserve 0.0 0.0 1.0 Shutdown Hours
- 9.
Gross Thermal 2535142.1 19571645.2 369377816.8 EneMy (MWHt)
- 10.
Gross Electric Energy 842434.0 6632209.0 124081241.0 (MWHe)
- 11.
Net Electrical Energy 818350.0 6501810.0 120044971.0 (MWHe)
- 12.
Reactor Service 100.0 100.0 70.5 Factor (%)
- 13.
Reactor Availability 100.0 100.0 71.4 Factor (%)
- 14.
Unit Service Factor 100.0 100.0 69.2
(% )
- 15.
Unit Availability 100.0 100.0 69.2 Factor
- 16.
Unit Capacity Factor 99.0 100.4 65.0 (MDC)
- 17.
Unit Capacity Factor 95.3 96.6 62.5 (design M~e)
- 18.
Unit Forced Outage 0.0 0.0 10.1 Factor (%)
I
- 19.
Shutdowns Scheduled Over Next 6 Months: Refueling outage (L1 R10) scheduled to start on January 13, 2004
- 20.
If Shutdown at End of Report Period, Date of Startup: N/A
B.
UNIT SHUTDOWNS AND OPERATING
SUMMARY
REPORT MONTH AUGUST 2003 NO DATE TYPE (1)
DURATION REASON (2)
METHOD OF CORRECTIVE (HOURS)*
SHUTTING ACTIONS/
DOWN COMMENTS REACTOR (3)
None I
I I
I I
I Year-to-date forced outage hours = 0.0 Cumulative forced outage hours = 13336.6 TABLE KEY:
(1)
F: Forced S: Scheduled (2)
Reason:
A Equipment Failure (Explain)
B Maintenance or Test C Refueling D Regulatory Restriction E Operator / Licensing Exam F Administrative G Operational Error (Explain)
H Other (Explain)
(3)
Method:
- 1. Manual
- 2. Manual Scram
- 3. Automatic Scram
- 4. Continuation
- 5. Other (Explain)
SUMMARY
LaSalle Unit 1 operated at full power for the month of August 2003, with the exception of the following:
August 2 - Power was reduced to about 1005 MWe to enable recovery of condensate booster pump suction pressure during isolation of the 14B feedwater heaters. The feedwater isolation was due to a failure of the solenoid for the 16 A heater normal drain valve. The solenoid was replaced and the unit was returned to full power on August 3, 2003.
August 30 - Power was reduced to about 600 MWe for control rod pattern adjustment and rod testing. The unit was returned to full power on September 1, 2003.
C.
UNIQUE REPORTING REQUIREMENTS FOR UNIT ONE
- 1.
Challenges other than routine surveillance testing to Safety/Relief Valve Operations-None
- 2.
Major Changes to Radioactive Waste Treatment System-None
II.
Monthly Report for LaSalle County Station Unit Two-August 2003 A.
OPERATING DATA
SUMMARY
FOR UNIT TWO DOCKET NO.:
50-374 UNIT:
LaSalle Two DATE:
September 9, 2003 COMPLETED BY:
S. Du Pont TELEPHONE:
(815) 415-2197
- 1.
Reporting Period: August 2003
- 2.
Currently Authorized Power Level: 3489 (MWt)
Design Electrical Rating: 1154 (MWe-net)
Max Dependable Capacity: 1111 (MWe-net)
- 3.
Power Level To Which Restricted (If Any): None
- 4.
Reasons For Restriction (If Any): N/A THIS MONTH YEAR-TO-DATE CUMULATIVE
- 5.
Reactor Critical Hours 744.0 4957.7 112994.3
- 6.
Reactor Reserve 0.0 0.0 1716.9 Shutdown Hours
- 7.
Hours Generator On-744.0 4873.1 111902.5 Une
- 8.
Unit Reserve 0.0 0.0 0.0 Shutdown Hours
- 9.
Gross Thernal 2592999.8 16390497.3 351048352.2 Energy (MWHt)
- 10.
Gross Electric Energy 869901.0 5565684.0 118133946.0 (MWHe)
- 11.
Net Electrical Energy 844248.0 5432923.0 113758364.0 (MWHe)
- 12.
Reactor Service 100.0 85.0 68.3 Factor (% )__
- 13.
Reactor Availability 100.0 85.0 69.4 Factor (%)
- 14.
Unit Service Factor 100.0 83.6 67.7
- 15.
Unit Availability 100.0 83.6 67.7 Factor
- 16.
Unit Capacity Factor 102.1 83.9 64.5 (MDC)
- 17.
Unit Capacity Factor 98.3 80.7 62.0 (design MWe)
- 18.
Unit Forced Outage 0.0 4.0 14.8 Factor (%)
I_
I_
I 19.
20.
Shutdowns Scheduled Over Next 6 Months: None If Shutdown at End of Report Period, Date of Startup: N/A
VERIFICATION AND VALIDATION PA CKA GE Page 1 B.
UNIT SHUTDOWNS AND OPERATING
SUMMARY
REPORT MONTH AUGUST 2003 NO DATE TYPE DURATION REASON (2)
METHOD CORRECTIVE (1)
(HOURS)*
OF ACTIONS/
SHUTTING COMMENTS DOWN REACTOR N
o n e I__
I__
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __(3
)_
1 None IIIIII Year-to-date forced outage hours = 88.0 Cumulative forced outage hours = 19330.2 TABLE KEY:
(1)
F: Forced S: Scheduled (2)
Reason:
A Equipment Failure (Explain)
B Maintenance or Test C Refueling D Regulatory Restriction E Operator / Licensing Exam F Administrative G Operational Error (Explain)
H Other (Explain)
(3)
Method:
- 1. Manual
- 2. Manual Scram
- 3. Automatic Scram
- 4. Continuation
- 5. Other (Explain)
SUMMARY
LaSalle Unit 2 operated at full power for the month of August 2003, with no exceptions.
C.
UNIQUE REPORTING REQUIREMENTS FOR UNIT TWO
- 1.
Challenges other than routine surveillance testing to Safety/Relief Valve Operations-None
- 2.
Major Changes to Radioactive Waste Treatment Systems-None p:\\wptdocs\\corrkregassuriv&vpkg.doc