September 22, 2003 Mr. David A. Christian Senior Vice President - Nuclear Virginia Electric and Power Company 5000 Dominion Blvd.
Glen Allen, Virginia 23060
SUBJECT:
SURRY POWER STATION, UNIT 2 - REVIEW OF STEAM GENERATOR TUBE INSERVICE INSPECTION REPORT FOR THE 2002 REFUELING OUTAGE (TAC NO. MB9651)
Dear Mr. Christian:
By letter dated February 26, 2003, Virginia Electric and Power Company (VEPCO) submitted the steam generator tube inspection report for the Spring 2002 refueling outage of Surry Power Station, Unit 2. The U.S. Nuclear Regulatory Commission (NRC) staff reviewed the information provided in the February 26, 2003, report (ADAMS Accession No. ML030690393) as well as the summary of the conference call held with VEPCO on April 17, 2002, during the ongoing steam generator inspections (ADAMS Accession No. ML021440455).
Based on this review, the NRC staff concludes that VEPCO provided sufficient information and that there are no issues that warrant additional followup at this time. No formal summary of our assessment was prepared since no issues were identified that warranted further discussion.
The NRC staff appreciates your assistance in this matter.
Sincerely,
/RA/
Christopher Gratton, Sr. Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-281 cc: See next page
ML030690393) as well as the summary of the conference call held with VEPCO on April 17, 2002, during the ongoing steam generator inspections (ADAMS Accession No. ML021440455).
Based on this review, the NRC staff concludes that VEPCO provided sufficient information and that there are no issues that warrant additional followup at this time. No formal summary of our assessment was prepared since no issues were identified that warranted further discussion.
The NRC staff appreciates your assistance in this matter.
Sincerely,
/RA/
Christopher Gratton, Sr. Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-281 cc: See next page Distribution:
PUBLIC KLandis, RII ACRS ABlack LLund OGC PDII-1 R/F EDunnington MMurphy SMonarque ADAMS: ML032650639
- See memorandum dated 8/4/03 OFFICE PM:PDII-1 LA:PDII-2 EMCB(C):SC*
SC:PDII-1 NAME CGratton EDunnington LLund JNakoski DATE 9/17/03 9/16/03 08/04/03 9/18/03
Mr. David A. Christian Virginia Electric and Power Company cc:
Ms. Lillian M. Cuoco, Esq.
Senior Counsel Dominion Resources Services, Inc.
Millstone Power Station Building 475, 5th Floor Rope Ferry Road Rt. 156 Waterford, Connecticut 06385 Mr. Richard H. Blount, II Site Vice President Surry Power Station Virginia Electric and Power Company 5570 Hog Island Road Surry, Virginia 23883-0315 Senior Resident Inspector Surry Power Station U. S. Nuclear Regulatory Commission 5850 Hog Island Road Surry, Virginia 23883 Chairman Board of Supervisors of Surry County Surry County Courthouse Surry, Virginia 23683 Dr. W. T. Lough Virginia State Corporation Commission Division of Energy Regulation P. O. Box 1197 Richmond, Virginia 23218 Robert B. Strobe, M.D., M.P.H.
State Health Commissioner Office of the Commissioner Virginia Department of Health P.O. Box 2448 Richmond, Virginia 23218 Surry Power Station Units 1 and 2 Office of the Attorney General Commonwealth of Virginia 900 East Main Street Richmond, Virginia 23219 Mr. Chris L. Funderburk, Director Nuclear Licensing & Operations Support Virginia Electric and Power Company Innsbrook Technical Center 5000 Dominion Blvd.
Glen Allen, Virginia 23060-6711 Mr. David A. Heacock Site Vice President North Anna Power Station Virginia Electric and Power Company P. O. Box 402 Mineral, Virginia 23117-0402 Mr. William R. Matthews Vice President - Nuclear Operations Virginia Electric and Power Company Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, Virginia 23060-6711