Review of Steam Generator Tube Inservice Inspection Report from the Fall 2001 Outage
ML032320456
Person / Time
Site: Turkey Point NextEra Energy icon.png
Issue date: 08/20/2003
From: Ellen Brown
NRC/NRR/DLPM/LPD2
To: Stall J
Florida Power & Light Co
Brown Eva, NRR/DLPM, 415-2315
References
TAC MB6492
Download: ML032320456 (5)


Text

August 20, 2003 Mr. J. A. Stall Senior Vice President, Nuclear and Chief Nuclear Officer Florida Power and Light Company P.O. Box 14000 Juno Beach, Florida 33408-0420

SUBJECT:

TURKEY POINT UNIT 3 - REVIEW OF STEAM GENERATOR TUBE INSERVICE INSPECTION REPORT FROM THE FALL 2001 OUTAGE (TAC NO. MB6492)

Dear Mr. Stall:

By letters dated October 20, 2001, January 24, and October 7, 2002, Florida Power and Light Company (FPL, the licensee) submitted reports summarizing the steam generator (SG) tube inspections performed during the End of Cycle (EOC) 18 (fall 2001) refueling outage for Turkey Point Unit 3. These reports were submitted in accordance with Turkey Point Unit 3 Technical Specification (TS) Sections 4.4.5.5.b and 6.9.2. Additional Information regarding the results of the EOC 18 tube inspection can be found in an April 5, 2002, letter from the U.S. Nuclear Regulatory Commission (NRC) to the licensee.

A summary of the NRC staffs evaluation of the EOC 18 refueling outage SG tube inspection results is enclosed. The NRC staff concluded that FPL provided the information required by the Turkey Point Unit 3 TS and that no additional follow-up is required at this time.

Sincerely,

/RA/

Eva A. Brown, Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-250

Enclosure:

As stated cc w/enclosures: See next page

August 20, 2003 Mr. J. A. Stall Senior Vice President, Nuclear and Chief Nuclear Officer Florida Power and Light Company P.O. Box 14000 Juno Beach, Florida 33408-0420

SUBJECT:

TURKEY POINT UNIT 3 - REVIEW OF STEAM GENERATOR TUBE INSERVICE INSPECTION REPORT FROM THE FALL 2001 OUTAGE (TAC NO. MB6492)

Dear Mr. Stall:

By letters dated October 20, 2001, January 24, and October 7, 2002, Florida Power and Light Company (FPL, the licensee) submitted reports summarizing the steam generator (SG) tube inspections performed during the End of Cycle (EOC) 18 (fall 2001) refueling outage for Turkey Point Unit 3. These reports were submitted in accordance with Turkey Point Unit 3 Technical Specification (TS) Sections 4.4.5.5.b and 6.9.2. Additional Information regarding the results of the EOC 18 tube inspection can be found in an April 5, 2002, letter from the U.S. Nuclear Regulatory Commission (NRC) to the licensee.

A summary of the NRC staffs evaluation of the EOC 18 refueling outage SG tube inspection results is enclosed. The NRC staff concluded that FPL provided the information required by the Turkey Point Unit 3 TS and that no additional follow-up is required at this time.

Sincerely,

/RA/

Eva A. Brown, Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-250

Enclosure:

As stated cc w/enclosures: See next page Distribution:

PUBLIC EBrown AHowe EHackett LLund BClayton (Hard copy)

PDII-2 R/F OGC ACRS LMilller JMunday Adams Accession No. ML032320456 OFFICE PDII-2/PM PDII-2/LA EMCB/SC PDII-2/SC NAME EBrown BClayton LLund (by memo)

BMozafari for AHowe DATE 8/20/2003 8/20/2003 03/26/03 8/20/2003 OFFICIAL RECORD COPY

Enclosure 40% Plugged Tubes Preventively Total Tubes Steam Tubes Plugged Plugged Generator 0

1 1

3A 1

10 11 3B 0

2 2

3C OFFICE OF NUCLEAR REACTOR REGULATION STAFF ASSESSMENT OF FALL 2001 (END OF CYCLE 18)

STEAM GENERATOR INSPECTION REPORT FLORIDA POWER AND LIGHT COMPANY TURKEY POINT UNIT NO. 3 DOCKET NO. 50-250 By letters dated October 20, 2001, January 24, and October 7, 2002, Florida Power and Light Company (the licensee) submitted reports summarizing the steam generator (SG) tube inspections performed during the End of Cycle (EOC) 18 (fall 2001) refueling outage for Turkey Point Unit 3. These reports were submitted in accordance with Turkey Point Unit 3 Technical Specification (TS) Sections 4.4.5.5.b and 6.9.2. A summary of the U.S. Nuclear Regulatory Commission (NRC) staffs evaluation of the EOC 18 refueling outage tube inspection results is provided below.

Turkey Point Unit 3 has three (SG-3A, SG-3B, and SG-3C) Westinghouse Model 44F SGs.

The SGs utilize a hydraulic tubesheet expansion method and have 405 stainless steel tube support plates with broached quatrefoil holes. The SGs began operation in 1982 and have thermally treated Inconel 600 tubing. The SG tube inspection summary stated that the licensee inspected between 3158 and 3169 tubes full length in each SG using a bobbin probe (essentially 100 percent of the active tubes). In addition to the full-length inspections, the licensee inspected between 1685 and 1820 tubes partial length in each SG using a rotating coil probe (RPC). The RPC partial inspections were performed on approximately 50 percent of the tubes in Unit 3 within the hot-leg top of tubesheet region. A total of 14 tubes were plugged due to the inspection results. Tube plugging activities at the EOC 18 for each SG in Unit 3 are summarized below.

The TSs require the licensee to identify the location and percent through-wall thickness (depth) for each imperfection. An imperfection is a deviation from the fabrication requirements and specifications of a tube in regards to contour, dimensions, and finish (TS 5.5.9.4.a.1). The licensee provided a list consisting of the location and percent of wall-thickness penetration for those indications with a through-wall thickness of 20 percent to 39 percent (total of 50 imperfections). An imperfection with a through wall-thickness 40 percent was reported for SG-3B. The licensee did report the exact location of this imperfection, but did not report the percent through-wall thickness for this imperfection. In future SG tube inspection reports, the NRC staff requests that this information be provided. The licensee noted that the preventively plugged tube in SG-3A was plugged due to wear at the first hot-leg broached support plate.

The preventively plugged tubes in SG-3B are stated to be a result of restriction in the u-bend to a Plus Point examination (Row 1 and Column 3), mechanical wear at anti-vibration bar (AVB)

AV2 in the u-bend, and mechanical wear at broached support plates. Mechanical wear located at the second hot-leg support plate resulted in the preventively plugged tubes in SG-3C. The indication reported in SG-3B with a through-wall thickness 40 percent was a result of loose-part wear at the third cold-leg support plate. The depth of the mechanical wear imperfections located at AVBs were measured using the bobbin coil sizing technique.

Mechanical wear imperfections located at broached support plates were depth sized using the Plus Point probe data. There were 36 mechanical wear imperfections (40 percent) located at AVBs (AV1 thru AV4) left in service. Also, no new geometry anomalies or volumetric/pit like imperfections were reported to have been identified.

Additional, information regarding the results of the EOC 18 tube inspection are provided in an April 5, 2002, letter from the NRC to the licensee (refer to ADAMS NO. ML020990345). Based on review of the information provided by the licensee, the NRC staff concludes that the licensee provided the required information outlined by the TSs and that at this time no additional information is required. However, the following observation was made by the NRC staff.



In future SG tube inspection reports, the NRC staff requests that the licensee identify imperfection location and percent through-wall thickness for both 20 percent-39 percent and 40 percent imperfections.

Mr. J. A. Stall TURKEY POINT PLANT Florida Power and Light Company cc:

M. S. Ross, Attorney Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 T. O. Jones, Site Vice President Turkey Point Nuclear Plant Florida Power and Light Company 9760 SW. 344th Street Florida City, FL 33035 County Manager Miami-Dade County 111 NW 1 Street, 29th Floor Miami, Florida 33128 Senior Resident Inspector Turkey Point Nuclear Plant U.S. Nuclear Regulatory Commission 9762 SW. 344th Street Florida City, Florida 33035 Mr. William A. Passetti, Chief Department of Health Bureau of Radiation Control 2020 Capital Circle, SE, Bin #C21 Tallahassee, Florida 32399-1741 Mr. Craig Fugate, Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 Attorney General Department of Legal Affairs The Capitol Tallahassee, Florida 32304 Michael O. Pearce Plant General Manager Turkey Point Nuclear Plant Florida Power and Light Company 9760 SW. 344th Street Florida City, FL 33035 Walter Parker Licensing Manager Turkey Point Nuclear Plant 9760 SW 344th Street Florida City, FL 33035 Vice President, Nuclear Operations Support P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. Rajiv S. Kundalkar Vice President - Nuclear Engineering Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420