ML032300021

From kanterella
Jump to navigation Jump to search

Tech Spec Pages for Amendments Revising Limiting Conditions for Operation, the Associated Conditions and Required Actions of Technical Specification 3.7.1 and Values in Table 3.7.1-1
ML032300021
Person / Time
Site: Byron, Braidwood  Constellation icon.png
Issue date: 08/12/2003
From:
NRC/NRR/DLPM
To:
References
TAC MB6077, TAC MB6078, TAC MB6079, TAC MB6080
Download: ML032300021 (6)


Text

MSSVs 3.7.1 3.7 PLANT SYSTEMS 3.7.1 Main Steam Safety Valves (MSSVs)

LCO 3.7.1 Five MSSVs per steam generator shall be OPERABLE. I APPLICABILITY: MODES 1, 2, and 3.

ACTIONS


NOTE-------------------

Separate Condition entry is allowed for each MSSV.

CONDITION REQUIRED ACTION COMPLETION TIME A. One or more steam A.1 Reduce THERMAL POWER 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> generators with one or to less than or equal more MSSVs inoperable. to the Maximum Allowable % RTP specified in Table 3.7.1-1 for the number of OPERABLE MSSVs.

AND A.2 - ----NOTE--

Only required in Mode 1.

Reduce the Power 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> Range Neutron Flux-High reactor trip setpoint to less than or equal to the Maximum Allowable X RTP specified in Table 3.7.1-1 for the number of OPERABLE MSSVs.

BYRON - UNITS 1 & 2 3.7.1 - 1 Amendment 133

MSSVs 3.7.1 ACTIONS (continued)

B Required Action and B.1 Be in MODE 3. 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met. ANLD OR B.2 Be in MODE 4. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> One or more steam generators with > 4 MSSVs inoperable. I SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.1.1 ------------------- NOTE-------------

Only required to be performed in MODES 1 and 2.

Verify each/required MSSV lift setpoint per In accordance Table 3.7.1-2 in accordance with the with the Inservice Testing Program. Following Inservice testing, lift setting shall be within +/- 1%. Testing Program BYRON - UNITS I & 2 3.7.1 - 2 Amendment 133

MSSVs 3.7.1 Table 3.7.1-1 (page 1 of 1)

OPERABLE Main Steam Safety Valves versus Maximum Allowable Power I NUMBER OF OPERABLE -MAXIMUM ALLOWABLE MSSVs PER STEAM POWER (% RTP)

GENERATOR 4 < 56 3 < 39 2 < 23 BYRON - UNITS 1 & 2 3.7.1 - 3 Amendment 133

MSSVs 3.7.1 3.7 PLANT SYSTEMS 3.7.1 Main Steam Safety Valves (MSSVs)

LCO 3.7.1 Five MSSVs per steam generator shall be OPERABLE. I APPLICABILITY: MODES 1, 2, and 3.

ACTIONS


---------------- ------ NOTE-------------

Separate Condition entry is allowed for each MSSV.

CONDITION REQUIRED ACTION COMPLETION TIME A. One or more steam A.1 Reduce THERMAL POWER 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> generators with one or to less than or equal more MSSVs inoperable. to the Maximum Allowable % RTP specified in Table 3.7.1-1 for the number of OPERABLE MSSVs.

AND A.2 ------- NOTE---

Only required in Mode 1.

Reduce the Power 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> Range Neutron Flux -

High reactor trip setpoint to less than or equal to the Maximum Allowable

% RTP specified in Table 3.7.1-1 for the number of OPERABLE MSS~s.

BRAIDWOOD - UNITS 1 & 2 3.7.1 - 1 Amendment 128

MSSVs 3.7.1 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME B. Required Action and B.1 Be in MODE 3. 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met. AND OR B.2 Be in MODE 4. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> One or more steam generators with Ž 4 MSSVs inoperable. I SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.1.1 --------------- NOTE--------------------

Only required to be performed in MODES 1 and 2.

Verify each required MSSV lift setpoint per In accordance Table 3.7.1-2 in accordance with the with the Inservice Testing Program. Following Inservice testing, lift setting shall be within +/- 1X. Testing Program BRAIDWOOD - UNITS 1 & 2 3.7.1 - 2 Amendment 128

MSSVs 3.7.1

. 'Table 3.7.1-1 (page 1 of 1)

OPERABLE Main Steam Safety Valves Versus Maximum Allowable Power I NUMBER OF OPERABLE MAXIMUM ALLOWABLE MSSVs PER STEAM POWER (% RTP)

GENERATOR I

4

  • 56 I 3 < 39 I 2
  • 23 I BRAIDWOOD - UNITS 1 & 2 3.7.1 - 3 Amendment 128