ML032230313

From kanterella
Jump to navigation Jump to search
BWRVIP-117: BWR Vessel & Internals Project, RAMA Fluence Methodology Plant Application - Susquehanna Unit 2 Surveillance Capsule Fluence Evaluation for Cycles 1-5
ML032230313
Person / Time
Site: Susquehanna, PROJ0704  
Issue date: 08/05/2003
From: Terry C
Constellation Generation Group, Electric Power Research Institute
To: Meena Khanna
Document Control Desk, Office of Nuclear Reactor Regulation
References
BWRVIP-117
Download: ML032230313 (6)


Text

are EL EC TR IF Y T HE WO R L D g2 BW RVI P BWR Vessel & Internals Project 2003-275 August 5, 2003 Document Control Desk U. S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852 Attention:

Meena Khanna

Subject:

Project No. 704 - BWRVIP-117: BWR Vessel and Internals Project, RAMA Fluence Methodology Plant Application - Susquehanna Unit 2 Surveillance Capsule Fluence Evaluation for Cycles 1-5 Enclosed are ten (10) copies of the report "BVWRVIP-1 17: BWR Vessel and Internals Project, RAMA Fluence Methodology Plant Application - Susquehanna Unit 2 Surveillance Capsule Fluence Evaluation for Cycles 1-5," EPRI Technical Report 1008065, July 2003. This report is being transmitted to the NRC as a means of exchanging information with the NRC for the purpose of supporting generic regulatory improvements related to methodologies to determine neutron fluence in BWR internal components.

The enclosed report describes the results of a surveillance capsule fluence evaluation performed for the Susquehanna Unit 2 reactor at the end of cycle 5 that was performed to qualify the RAMA Fluence Methodology for use in the evaluation of neutron fluence in BWRs. The BWRVIP is continuing work on the RAMA fluence methodology and expects to provide additional reports to the NRC on this subject in the near future. Additional reports expected to be provided include a RAMA Procedures Manual and one additional plant-specific application.

Please note that the enclosed report contains proprietary information. A letter requesting that the report be withheld from public disclosure and an affidavit describing the basis for withholding this information are provided as Attachment 1.

If you have any questions on this subject, please contact Robin Dyle (Southern Nuclear),

BWRVIP Assessment Committee Technical Chairman, by telephone at 205.992.5885.

Sincerely, Carl Terry Chairman, BWR Vessel and Internals Project Constellation Generation Group Nine Mile Point Nuclear Station CORPORATE HEADOUARTERS 3412 Hillview Avenue I Palo Alto CA 94304-1395 USA I 650.855.2000 I Customer Service 800.313.3774 I www.epri.com

C:

Lambros Lois, NRC EL EC TR IF Y T HE W OR L D f =

r2 I

August 1, 2003 Document Control Desk U.S. Nuclear Regulatory Commission 11555 Rockville Pike Washington DC, 20555

Subject:

"BWRVIP-1 17: BWR Vessel and Internals Project, RAMA Fluence Methodology Plant Application - Susquehanna Unit 2 Surveillance Capsule Fluence Evaluation for Cycles 1-5," EPRI Report 1008065, July 2003.

Gentlemen:

This is a request under 10CFR2.790(a)(4) that the NRC withhold from public disclosure the information identified in the enclosed affidavit consisting of EPRI owned Proprietary Information identified above (the "Report"). Copies of the Report and the affidavit in support of this request are enclosed.

EPRI desires to disclose the Report in confidence to the NRC as a means of exchanging information in support of generic regulatory improvements relating to methodologies to determine neutron fluence in BWR internal components. Further, EPRI welcomes any discussion with the NRC regarding the Report that the NRC desires to conduct.

The Report is for the NRC's internal use and may be used only for the purposes for which it is disclosed by EPRI. The report should not be otherwise used or disclosed to any person outside the NRC without prior written permission from EPRI.

If you have any questions about the legal aspects of this request for withholding, please do not hesitate to contact me at (650) 855-2340. Questions on the contents of the Report should be directed to Mr. Tom Mulford of EPRI at (650) 855-2766.

Sincerely, Warren J. Bilanin Director, Nuclear Power Sector Enclosures c:

Nichole Edraos, EPRI CORPORATE HEADOUARTERS 3412 Hillview Avenue I Palo Alto CA 94304-1395 USA I 650.955.2000 I Customer Service 800.313.3774 l www.epri.com

B l

R AFFIDAVIT RE:

"BWRVIP-117: BWR Vessel and Internals Project, RAMA Fluence Methodology Plant Application - Susquehanna Unit 2 Surveillance Capsule Fluence Evaluation for Cycles 1-5," EPRI Report 1008065, July 2003.

I, WARREN J. BILANIN, being duly sworn, depose and state as follows:

I am a Director at the Electric Power Research Institute ("EPRr') and I have been specifically delegated responsibility for the report listed above that is sought under this affidavit to be withheld (the "Report") and authorized to apply for their withholding on behalf of EPRI. This affidavit is submitted to the Nuclear Regulatory Commission ("NRC") pursuant to 10 CFR 2.790 (a)(4) based on the fact that the Report consists of trade secrets of EPRI and that the NRC will receive the Report from EPRI under privilege and in confidence.

The basis for withholding such Report from the public is set forth below:

(i) The Report has been held in confidence by EPRI, its owner. All those accepting copies of the Report must agree to preserve the confidentiality of the Report.

(ii) The Report is a type customarily held in confidence by EPRI and there is a rational basis therefor. The Report is a type, which EPRI considers as a trade secret(s) and is held in confidence by EPRI because to disclose it would prevent EPRI from licensing the Report at fees, which would allow EPRI to recover its investment. If consultants and/or other businesses providing services in the electric/nuclear power industry were able to publicly obtain the Report, they would be able to use it commercially for profit and avoid spending the large amount of money that EPRI was required to spend in preparation of the Report. The rational basis that EPRI has for classifying this/these Report(s) as a trade secrets is justified by the Uniform Trade Secrets Act, which California adopted in 1984 and which has been adopted by over twenty states. The Uniform Trade Secrets Act defines a "trade secret" as follows:

"Trade secret" means information, including a formula, pattern, compilation, program, device, method, technique, or process, that:

(1) Derives independent economic value, actual or potential, from not being generally known to the public or to other persons who can obtain economic value from its disclosure or use; and (2) Is the subject of efforts that are reasonable under the circumstances to maintain its secrecy.

'I bl2l (iii) The Report will be transmitted to the NRC in confidence.

(iv) The Report is not available in public sources. EPRI developed the Report only after making a determination that the Report was not available from public sources. It required a large expenditure of dollars for EPRI to develop the Report. In addition, EPRI was required to use a large amount of time of EPRI employees. The money spent, plus the value of EPRI's staff time in preparing the Report, show that the Report is highly valuable to EPRI. Finally, the Report was developed only after a long period of effort of at least several months.

(v) A public disclosure of the Report would be highly likely to cause substantial harm to EPRI's competitive position and the ability of EPRI to license the Report both domestically and internationally. The Report can only be acquired and/or duplicated by others using an equivalent investment of time and effort.

I have read the foregoing and the matters stated therein are true and correct to the best of my knowledge, information and belief. I make this affidavit under penalty of perjury under the laws of the United States of America and under the laws of the State of California.

Executed at 3412 Hillview Avenue, Palo Alto, being the premises and place of business of the Electric Power Research Institute:

August 1, 2003 Warren J. Bilanin Subscribed and sworn before me this day:

August 1, 2003 ichole Alexandra Edraos, Notary Public A

^, IIICHOLE ALEXANDRA EDRAOS t

Comm.D 1295461 5~~~~M lb Eobpns Mb.26,l0 M

SUBSCRIBING WITNESS JURAT State of California County of 1Ss.

On

, before me, the DATE appeared me on the oath of SUBSCRIBINU WITNESS'S NAME C

CREDIBLE WITNESS'S MAN undersigned, a notary public for the state, personally personally known to me (or proved to

, who is personally known to me) to 4E be the person whose name is subscribed to the within instrument, as a witness there to, who, being by me duly sworn, deposed and said that he/she was present and saw J

Q b

the NAME(S) OF PRINCIPAL(S) same person(s) described in and whose name(s) is/are subscribed to the within and annexed instrument in his/her/their authorized capacity(ies) as (a) party(ies) thereto, execute the same, and that said affiant subscribed his/her name to the within instrument as a witness at the request of NAME(S) OF PRINCIPAL(S)

WITNESS my hand and official seal.

NOTARY'S SIGNATURE NFORMATION

,e valuable and could prevent fraudulent attachment of this DESCRIPTION OF ATTACHED DOCUMENT TITL E OF DOCUMENT NUMBER OF PAGES DATE OF DOCUMENT OTHER RIGHT THUMBPRINT t OF E

SIGNER C

OPTIONAL I!

The information below is optional. However, it may prov form to an unauthorized document.

CAPACITY CLAIMED BY SIGNER (PRINCIPAL)

LI INDIVIDUAL Li CORPORATE OFFICER Li F-1 Li Li LiLi Li TITLE(S)

PARTNER(S)

ATTORNEY-IN-FACT TRUSTEE(S)

GUARDIAN/CONSERVATOR SUBSCRIBING WITNESS OTHER:

ABSENT SIGNER (PRINCIPAL) IS REPRESENTING:

NAME OF PERSON(S) OR ENTITY(IES)

-*v*

i uw w ~_____

SWI 7/99 VALLEY-SIERRA, 8OD-362-3369