Primary Containment Isolation Instrumentation 3.3.6.1 Table 3.3.6.1-1 (page 2 of 3)
Primary Containment Isolation Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM SPECIFIED PER TRIP REQUIRED SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS SYSTEM ACTION C.1 REQUIREMENTS VALUE
- 3. High Pressure Coolant Injection (HPCI) System Isolation
- a. HPCI Steam Line 1,2.3 1
F SR 3.3.6.1.2 s 290.16 of Flow-High SR 3.3.6.1.3 rated steam SR 3.3.6.1.6 flow (Unit 2)
SR 3.3.6.1.7 s 288.23% of rated steam flow (Unit 3)
- b. HPCI Steam Line 1,2,3 1
F SR 3.3.6.1.2 2 3.2 seconds Flow-Timer SR 3.3.6.1.6 and SR 3.3.6.1.7 s 8.8 seconds
- c.
HPCI Steam Supply Line 1,2,3 2
F SR 3.3.B.1.2 2 104 psig Pressure-Low SR 3.3.6.1.3 SR 3.3.6.1.6 SR 3.3.6.1.7
- d. HPCI Turbine Area 1,2.3
- 44)
F SR 3.3.6.1.5 s 1891F Temperature-High SR 3.3.6.1.6 SR 3.3.6.1.7
- 4. Isolation Condenser System Isolation
- a. Steam Flow-High 1,2,3 1
F SR 3.3.6.1.2 s 273.65 of SR 3.3.6.1.4 rated steam SR 3.3.6.1.7 flow
- b. Return Flow-High 1.2,3 1
F SR 3.3.6.1.2 s 26.0 inches SR 3.3.6.1.4 water (Unit 2)
SR 3.3.6.1.7 s 10.7 inches water (Unit 3)
(continued)
(a)
All four channels must be associated with a single trip string.
I I
I Dresden 2 and 3 3.3.6.1-6 Amendment No. 1200/192