FENOC Pery Nuclear Power Plant 10 Center Road Perry, Ohio 44081 Edward K. Root Manager - Radwaste. Envirnntal, Chemistry 440-280-5646 Fax: 440-280-5681 July 14,2003 PY-CEIIOEPA-0403L
-.4 Ohio Environmental Protection Agency Division of Water Pollution Control Enforcement Section, ES/MOR P.O. Box 1049 ---
Columbus, Ohio 43216-1049 Ladies and Gentlemen:
Enclosed are the NPDES monthly report forms for the month of June 2003. The Preliminary Effluent Limit for copper was exceeded during this period. A separate letter was mailed detailing this issue in accordance with Part II of the National Pollutant Discharge Elimination System Permit.
If you have questions or require additional information, please contact Mr. Leo Harte at (440) 280-5514.
Very truly yours, Enclosures cc: NRC Region III NRC Resident Inspector NRC Project Manager NRC Document Control Desk (Docket No. 50-440)
I, 1
A
'I-e
.r~tC -.-
J";
s-
MONTHLY REPORT FORM 4500 Name, Address City, County, ZIP:
Station Code:
Reported Date (Month Year):
Application:
71812 PerryNuclearPowerPlant 004 June 2003 3IB00016*GD 10 Center Rd.
Sampiing Station
Description:
PerryOH44081 Point Representative of Discharge in(1) - Enter 1 for Continuous, 2 for Composite, 3 for Grab Sample Reporting Lab:
Analyst:
in(2) - Enter frequency of sampling CCB 125 Leo J.
Harte (1) 3 3
1 3
1 3
(2) 1 1
999 1
999 1
(00400)
(01119)
(00011)
(34044)
(50050)
(50064)
(78739) pH Copper, Total Water Temperature Oxidants, Total Flow Rate Chlorine, Free orination/Brominat S.U.
Recoverable F
Residual MGD Available Duration Day ug/l mg/l mg/I Minutes 01 63 71.1 0.U1 70 02 65 55.7 0.02 65 03 8.69 72 51.8 0
60 04 41 70 49.1 0.2
-65 05 71 50.6 0.06 70 06 8.65 69 49.5 0.02 75 07 72 50 0.01 65 08 1 73 45.7 0.04 35 09 73 62.7 0.1 95 10 8.69 70 89.3 0.01 85 11 74 91.2 0.02 75 12 74 63.2 0
91 13 8.61 74 64 0.01 85 14 73 55.2 0.02 so 15 76 55.5 0.02 80 16 76 47.9 0.02 77 17 8.86 76 45.5 0.03 80 18 75 49.8 0.11 90 19 72 60.2 0.02 75 20 8.64
-74 62.6 0.01 83 21 74 48.3 0.02 70 22 j
71 53.1 0.01 75 231 77 52.4 0
75 24 1
8.74 79 54.5 0.01 75 25 j
77 64.6 0.05 80 261 1
78 64.9 0
85 27 8.69 79 81.8 0.03 110 28 76 96.8 0.08 65 29 77 86.3 0.04 70 30 79 92.2 0.03 94 31 OTAL 69.57 41 2209 0
1865.5 1
2300 AVG N/A 41 73.6333 62.1833 0.0333 76.6667 MAtX 8.86 41 79 96.8 0.2 110 MIN 8.61 41 63 0
45.5 0
35 ertify under the penalty of law that I have personally examined and am familiar with the Information submitted and based on my quiry of those individuals immediately responsible for obtaining the Information, I believe the submitted Information Is true, accurate id complete. I am aware that there are significant penalties for submitting false Information, Including the possibility of fine and Imprisonment.
)ate Report Completed:
S iatujesop1eporter Title of Reporter:
07/08/2003 t
Manager, Environmental orm No EPA 4500 (8-91) 3enerated by SWIMS) ormerly EPA SURI Page 1 of
MONTHLY REPORT FORM 4500 Name, Address City, County, ZIP:
Perry Nuclear Power Plant Perry Nuclear Power Plant 10 Center Rd.
Perry OH 44081 Station Code:
004 Reported Date (Month Year):
June 2003 Application:
3IB00016*GD 718120 Sampling Station
Description:
Point Representative of Discharge
MONTHLY REPORT FORM 4500 Name, Address City, County, ZIP:
Station Code:
Reported Date (Month Year):
Application:
71812 Perry Nuctear Power Plant 601 June 2003 3IB00016*GD Perry' Nuclear Power Plant mpigSaonDsrto:
I0 Center Rd.SapigSainDsrto:
PerryOH4408l Discharge from Regenerate Neutralization Pits in(1) -Enterl1for Continuous, 2for Composite, 3for Grab Sample Reporting Lab:
Analyst:
in(2) -Enter frequency of sampling CCB 125 Leo J.
Harte OC-3 3
3 1
(2) 1 1
1 999 (0040 0)
(0053 0)
(00550) f (50050) pH Total Suspended Oil and rease, Flow ate S.13.
Solids Total MGD Day 1
mg/i
-~~~~~~~~~ 0.0184 02
_A__
~03:
AH 04 tAH 05 t
.All__--
_____________AH}
08 7.46 10 j __AA 0.018 0 9 A
12 869 I
-606017 13 AH___.
~l 14
.J All___H 15 AH 16 All 17 7.3 0018 18 All 19 I
~
l AH___
220 8.39 9
AA 0.015 2 2 -
A ll.-
-.-------.~~
~~~
~~~
~~
~~~~~~~~~~~~~~~~~~~
23 Al) 24 AH 25
___]I AH 26 IAllH
~
27 8.14 6
AA001 28 All
---~~~~..
.- - I
-. --~
OTAL 47.76 34 0
0.104 j
0 0
AVG N/A 8.5 0
0.0173
(_
MAX 8.6 10 0
0.018 f_______________
MIN 7.3 6
0 0.015
(
0 0
.ertify under the penalty of law that have personally examined and am familiar with the information submitted and based on my quiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate id complete.
am aware that there are significant penalties for submitting false nformation, including the possibility of fine and imprisonment.
Date Report Completed:
Sigt f
porter:
Title of Reporter:
07/08/2003
- Manager, Environmental aorm No EPA 4500 (8-91)
Generated by SWIMS) ormerly EPA SIURI Page of
MONTHLY REPORT FORM 4500 Name, Address City, County, ZIP:
Station Code:
Reported Date (Month Year):
Application:
71W'20 PerryNuclearPowerPlant 601 June 2003 31B00016*GD Perry Nuclear Power Plant 10 Center Rd.
Sampling Station
Description:
Perry OH 44081 Discharge from Regenerate Neutralization Pits feportlng Code Result Date dditlonal Remarks Mdl l
00550 06/08/2003 aess than MDL.
5.
00550 06/12/2003 Less than MDL.
5.
00550 06/20/2003 ess than MDL.
5.
00550 06/27/2003 ess than MDL.
5.
50050 06/02/2003 No discharge performed this ate.
50050 06/03/2003 No discharge performed this date.
50050 06/04/2003 To discharge performed this date.
50050 06/05/2003 o discharge performed this date.
50050 06/06/2003 o discharge performed this date.
50050 06/07/2003 No discharge performed this date.
_050 06/09/2003 discharge performed this date.
50050 06/09/2003 lo discharge performed this date.
50050 06/10/2003 To discharge performed this date.
50050 06/11/2003 To discharge performed this date.
50050 06/13/2003 go discharge performed this date.
50050 06/14/2003 go discharge performed this date.
50050 06/15/2003 go discharge performed this date.
50050 06/16/2003 go discharge performed this date.
50050 06/16/2003 o discharge performed this date.
50050 06/19/2003 go discharge performed this date.
50050 06/21/2003 o discharge performed this date.
50050 06/22/2003 o discharge performed this date.
50050 06/23/2003 o discharge performed this date.
50050 06/24/2003 o discharge performed this date.
50050 06/25/2003 o discharge performed this date.
50050 06/26/2003 o discharge performed this date.
50050 06/28/2003 o discharge performed this date.
50050 06/29/2003 lodischarge performed this date.
50050 06/30/2003 g4o discharge performed this date.
1ONTHLY REPORT FORM 4500 Name, Address City, County, ZIP:
Station Code:
Reported Date (Month Year):
Application:
71812 DerryNuclearPowerPlant 602 June 2003 31800016*GD eny Nuclear Power Plant Sampling Station
Description:
PerryOH440O1 Discharge from Chemical Cleaning Lagoon in() - Enter 1 for Continuous, 2 for Composite, 3 for Grab Sample Reporting Lab:
Analyst:
in2)-Enter frequency of sampling CCB 125 Leo J.
Harte (1)
____--2 2
3 2
3 1
(2) 998 998 1
998 1
999 (00980)
(01119)
(00400)
(00530)
(00550)
(50050)
Iron, Total Copper. Total pH Total Suspended Oil and Grease, Flow Rate Recoverable Recoverable S.U.
Solids Total MGD Day ug/l__
ug/l g
gtl 01 AL 02 03 04 05 06 07 08 09 10 12 13 14 16 18 1 i 24 21_
22 3
25 26 28
/
I
-29 jj._
30 31 rOTAL 0
0 0
0 0
0 0
AVG 0
N/A UAX 0
MIN 0
0 0
0 certify under the penalty of law that I have personally examined and am familiar with the information submitted and based on my iquiry of those individuals Immediately responsible for obtaining the Information. I believe the submitted Information Is true. accurate nd complete. I am aware that there are significant penalties for submitting false Information, including the possibility of fine and mprisonment Date Report Completed:
Sign ureP~porter.
Title of Reporter:
07/08/2003 C
- Manager, Environmental
- orr No EPA 4500 (8-91)
Generated by SWIMS)
- ormerly EPA SURI Page 1 of
MONTHLY REPORT FORM 4500 Name, Address City, County, ZIP:
Station Code:
Reported Date (Month Year):
Application:
718120 Perry Nuclear Power Plant 602 June 2003 31B00016*GD Perry Nuclear Power Plant 10 Center Rd.
Sampling Station
Description:
Perry OH 44081 Discharge from Chemical Cleaning Lagoon Feportlng Code pesult Date Additional Remarks jMdl 00980 06/01/2003 ro discharge performed for the month.
MONTHLY REPORT FORM 4500 MON.hLY RE.ORT FORM 4508 Name, Address City, County, ZIP:
Station Code:
Rbported Date (Month Year):
Application:
71812 Perry Nuclear Power Plant 800 4Ui6 003 31B00016*GD Perry Nuclear Power Plant S
S D cito 10 Center Rd.
Sampling Station Descrption PerryOH44081 Intake Water from Lake Erie in(1) - Enter 1 for Continuous. 2 for Composite, 3 for Grab Sample Reporting Lab:
Analyst:
in(2) - Enter frequency of sampling CCB 125 Leo J Harte (1) 3
.1
__---I (2) 1 999 l
(01119)
(00011)
Copper. Total ater Temperature Recoverable F
Day ug/h 01 57 02 57 03 65 04 30 58 05 57 06 56 07 57 08 57 09 60 10 60 11 62 12 62 13 61 14 63 15 64 16 62 17 62 18-59 19 59 20 59 211 59 22_
_57_
23 1
63 66 25 66 26 68 27 1_7 § 28 I-70 29j 71 30 j 71 31 73TAL 0
1859 0
0 0
0 0
AVG 30 61.9667 30 71 MIN 30 56 0
0 0
0 0
certify under the penalty of law that I have personally examined and am familiar with the Information submitted and based on my iquiry of those Individuals Immediately responsible for obtaining the Information I believe the submitted Information Is true, accurate nd complete. I am aware that there are significant penalties for submitting false Infomation, including the possibility of fine and imprisonment I~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Date Report Completed:
Si porter Title of Reporter 07/08/2003 CX177-Manager, Environmental orm No EPA 4500 (8-91)
Generated by SWIMS)
- ormerly EPA SURI Page 1 of
MONTHLY REPORT FORM 4500 Name, Address City, County, ZIP:
Perry Nuclear Power Plant Perry Nuclear Power Plant 10 Center Rd.
Peny OH 44081 Station Code!
800 Reported Date (Month Year):
June 2003 Application:
3IB00016*GD 71820 Sampling Station
Description:
Intake Water from Lake Erie