ML031750604
| ML031750604 | |
| Person / Time | |
|---|---|
| Site: | Quad Cities |
| Issue date: | 06/12/2003 |
| From: | Tulon T Exelon Generation Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| GL-97-002, SVP-03-076 | |
| Download: ML031750604 (8) | |
Text
Exeon.
Exelon Generation Company, LLC www.exeloncorp.com Nuclear Ouad Cities Nuclear Power Station 22710 206" Avenue North Cordova, IL 61242-9740 June 12, 2003 SVP-03-076 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Quad Cities Nuclear Power Station, Units 1 and 2 Facility Operating License Nos. DPR-29 and DPR-30 NRC Docket Nos. 50-254 and 50-265
Subject:
Monthly Operating Report for May 2003 In accordance with Technical Specifications, Section 5.6.4, Monthly Operating Reports," we are submitting this Monthly Operating Report for Quad Cities Nuclear Power Station (QCNPS), Units 1 and 2.
Additionally, QCNPS has implemented the relaxation designated in NRC Generic Letter 97-02, "Revised Contents of the Monthly Operating Report," which allowed a reduction in information that was being submitted in the Monthly Operating Report.
These changes are and will be reflected in this and future reports.
Should you have any questions concerning this letter, please contact Mr. Wally Beck at (309) 227-2800.
Respectfully, Timothy. Tulon Site Vice President Quad Cities Nuclear Power Station Attachment cc:
Regional Administrator - NRC Region IlIl NRC Senior Resident Inspector - Quad Cities Nuclear Power Station
ATTACHMENT QUAD CITIES NUCLEAR POWER STATION UNITS 1 AND 2 MONTHLY OPERATING REPORT FOR MAY 2003 EXELON NUCLEAR AND MIDAMERICAN ENERGY COMPANY FACILITY OPERATING LICENSE NOS. DPR-29 AND DPR-30 NRC DOCKET NOS. 50-254 AND 50-265 Page 1 of 7
TABLE OF CONTENTS
- 1.
Introduction II.
Summary of Operating Experience A.
Unit One B.
Unit Two Ill.
Operating Data Statistics A.
Operating Data Report - Quad Cities Unit One B.
Operating Data Report - Quad Cities Unit Two IV.
Unit Shutdowns A.
Unit One Shutdowns B.
Uni Two Shutdowns V.
Challenges to Safety and Relief Valves Page 2 of 7
I. INTRODUCTION Quad Cities Nuclear Power Station is composed of two Boiling Water Reactors and Steam Turbine/Generators located in Cordova, Illinois. Unit One has a Maximum Dependable Capacity of 855 MWe Net, and Unit Two has a Maximum Dependable Capacity of 855 MWe Net. The Station is jointly owned by Exelon Nuclear and MidAmerican Energy Company. The Nuclear Steam Supply Systems are General Electric Company Boiling Water Reactors. The Architec Engineer was Sargent &
Lundy, Incorporated, and the primary construction contractor was United Engineers &
Constructors. The Mississippi River is the condenser cooling water source. The plant is subject to license numbers DPR-29 and DPR-30, issued October 1, 1971, and March 21, 1972, respectively, pursuant to Docket Numbers 50-254 and 50-265. The dates of initial Reactor criticality for Units One and Two were October 18, 1971, and April 26, 1972, respectively. Commercial generation of power began on February 18, 1973, for Unit One and March 10, 1973, for Unit Two.
Page 3 of 7
II.
SUMMARY
OF OPERATING EXPERIENCE A. Unit One Unit One began the month at full power with the exception of a planned load drop to approximately 820 MWe on May 4, 2003 to perform intermediate control rod exercising. On May 20, 2003, Unit One began shutdown activities to support Q1 Ml 6, a planned reactor shutdown to replace 233 fuel bundles due to fuel leaks, with the Unit retuming to service on May 31, 2003.
B. Unit Two Unit Two began the month at full power with the exception of a planned load drop on May 3, 2003 to approximately 740 MWe for a puff test to verify fuel leakage. On May 8, 2003, Unit Two shut down to replace 3B and 3E PORVs due to high tailpipe temperatures. Unit Two initiated power ascension activities on May 11, 2003. Unit Two increased power to approximately 640 MWe on May 12, 2003, then load was decreased to approximately 420 MWe for Control Rod Maneuvers. Power ascension then resumed until full power on May 14, 2003. A load drop occurred on May 24, 2003 to approximately 540 MWe for Planned Power Suppression Testing. The Unit was returned to full power on May 27, 2003. On May 28, 2003, excess moisture carryover levels were identified and load was decreased to approximately 811 MWe for the remainder of the month.
Page 4 of 7
Ill.
OPERATING DATA STATISTICS A.
Quad Cities Unit One Operating Data Report for May 2003 DOCKET NO.:
DATE:
COMPLETED BY:
TELEPHONE:
50-254 June 12, 2003 Debbie Cline (309) 227-2801 OPERATING STATUS REPORTING PERIOD: May 2003 GROSS HOURS IN REPORTING PERIOD: 744 CURRENTLY AUTHORIZED POWER LEVEL (MWt): 2957
- 1.
DESIGN ELECTRICAL RATING (MWe-Net): 867
- 2.
MAX. DEPEND. CAPACITY (MWe-Net): 855 UNIT 1 OPERATING STATUS PARAMETER THIS MONTH YTD CUMULATIVE
- 3.
NUMBER OF HOURS THE REACTOR WAS CRITICAL 521.20 3400.20 213070.40
- 4.
HOURS GENERATOR ON-LINE 472.00 2879.00 207653.60
- 5.
UNIT RESERVE SHUTDOWN HOURS 0.00 0.00 1655.20
- 6.
NET ELECTRICAL ENERGY GENERATED (MWH) 403005.00 12864427.00 137088336.00 Page 5 of 7
Ill.
OPERATING DATA STATISTICS B.
Quad Cities Unit Two Operating Data Report for May 2003 DOCKET NO.:
DATE:
COMPLETED BY:
TELEPHONE:
50-265 June 12, 2003 Debbie Cline (309) 227-2801 OPERATING STATUS REPORTING PERIOD: May 2003 GROSS HOURS IN REPORTING PERIOD: 744 CURRENTLY AUTHORIZED POWER LEVEL (MWt): 2957
- 1.
DESIGN ELECTRICAL RATING (MWe-Net): 867
- 2.
MAX. DEPEND. CAPACITY (MWe-Net): 855 UNIT 2 OPERATING STATUS I
PARMETER THIS MONTH YTD CUMULATIVE
- 3.
NUMBER OF HOURS THE REACTOR WAS CRITICAL 705.50 3502.90 205998.00
- 4.
HOURS GENERATOR ON-LINE 695.00 3478.00 201149.15
- 5.
UNIT RESERVE SHUTDOWN HOURS 0.00 0.00 2312.90
- 6.
NET ELECTRICAL ENERGY GENERATED (MWH) 551711.00 2999754.00 138414754.00 Page 6 of 7
IV. UNIT SHUTDOWNS A. Unit ONE Shutdowns for May 2003 NO.
DATE TYPE DURATION REASON (2)
METHOD CORRECTIVE FOR
()
(OR)OF ACTIONS1COMMENTS YEAR
()
(OR)SHUTTING
_D O W N (3)
Replace leaking fuel 1
05-20-03 S
273.9 B
1 (Q1 M16)
B. Unit TWO Shutdowns for May 2003 NO.
DATE TYPE DURATION REASON (2)
METHOD CORRECTIVE FOR (1)
(HOURS)
OF ACTIONS/COMMENTS
~~~ ~~~~~~~DOW N (3)
Replace 3B and 3E PORVs due to high 2
05-08-03 F
49.3 A
1 tailpipe temperatures
_ _ _ _(
2 F 5 8 )
Legend (1) TYPE (2) REASON (3) METHOD F - Forced A. Equipment Failure (Explain)
- 1. Manual S - Scheduled B. Maintenance or Test
- 2. Manual Trip/Scram C. Refueling
- 3. Automatic Trip/Scram D. Regulatory Restriction
- 4. Continuation E. Operator Training/License Examination
- 5. Other (Explain)
F. Administrative G. Operational Error (Explain)
H. Other (Explain)
V. CHALLENGES TO SAFETY AND RELIEF VALVES April 2003 l Unit 1 l None Unit 2 I None Page 7 of 7