ML031560674

From kanterella
Jump to navigation Jump to search
FOIA/PA-2003-0018 - Resp 7 - Partial
Date released: 06/10/2003 Download: ML031560674


Failure Criterion Development and Parametric Finite Element Analyses to Assess Margins for the Davis-Besse RPV Head Corrosion with Handwritten Notes
ML031560654
Person / Time
Site: Davis Besse 
Issue date: 04/30/2002
From: David Rudland, Wang Y, Wilkowski G, Wolterman R
Engineering Mechanics Corp of Columbus
To:
Office of Nuclear Regulatory Research
References
FOIA/PA-2003-0018
Download: ML031560654 (28)
E-mail from R. Bass to C. Briggs, Regarding Support for Davis-Besse Significance Determination
ML031550687
Person / Time
Site: Davis Besse 
Issue date: 05/21/2002
From: Bass R
Oak Ridge
To: Christine Briggs
Office of Nuclear Regulatory Research
References
FOIA/PA-2003-0018
Download: ML031550687 (1)
E-mail from S. Long to Bassbr@Ornl,Gov, Regarding Support for Davis-Besse Significance Determination
ML031550686
Person / Time
Site: Davis Besse 
Issue date: 05/21/2002
From: Long S
Office of Nuclear Reactor Regulation
To: Chokshi N C, Hackett E M, Johnson M R, Kirk M T, Norris W E, Wilkowski G M
Office of Nuclear Reactor Regulation
References
FOIA/PA-2003-0018
Download: ML031550686 (2)
E-mail from G. Wilkowski to W. Norris, Regarding Davis-Besse Head Corrosion Margin Report
ML031550685
Person / Time
Site: Davis Besse 
Issue date: 05/03/2002
From: Wilkowski G
Engineering Mechanics Corp of Columbus
To: Norris W E
Office of Nuclear Regulatory Research
References
FOIA/PA-2003-0018
Download: ML031550685 (59)
FOIA/PA-2003-0018 - Resp 7 - Partial
ML031550682
Person / Time
Site: Davis Besse 
Issue date: 06/02/2003
From: Reed C
NRC/OCIO/WPDSD/FOIA
To: Riccio J P
Greenpeace
References
FOIA/PA-2003-0018
Download: ML031550682 (4)