NYSERDA New Yark State Energg Research and Development AutharitU Vincent A. Delorio, Esq., Ciairman Toll Free: 1 (866) NYSERDA www.nyserda.org info@nyserda.org May 13, 2003 Daniel M. Gillen U.S. NRC-TWFN NSSS/DWN/DCB 7-F27 11555 Rockville Pike Rockville, MD 20852-2738 Paul A. Giardina, Chief Radiation Indoor Air Branch U.S. EPA Region 2 290 Broadway, 2 8 1h Floor New York, NY 10007-1866 Edwin E. Dassatti, Chief Hazardous Waste & Radiation Management Division of Solid & Hazardous Materials NYS Department of Environmental Conservation 625 Broadway, 8 'h Floor Albany, NY 12233-7258

Dear Messrs. Gillen,

Giardina & Dassatti:

SUBJECT:

NYSERDA Comments on Acid Recovery Pump Room Radioisotope Inventory Report, RIR-403-005, Revision 0, dated 09/27/2002 The New York State Energy Research and Development Authority (NYSERDA) is providing the U.S.

Nuclear Regulatory Commission (NRC), the U.S. Environmental Protection Agency (EPA), and the New York State Department of Environmental Conservation (NYSDEC) with a copy ofNYSERDA's comment package on theAcidRecoveryPuimp Room RadioisotopeInventoryReport, RIR-403-005, Revision 0, dated 09/27/2002.

The information contained in this report, and a number of similar reports, will be used to estimate the residual source term in the Process Building and other West Valley facilities.

To facilitate early sharing of information and resources, NYSERDA, as a matter of course, intends to lain Office Albany 17 Columbia Circle Albany, NY 12203-6399 Toll Free: 1 (866) NYSERDA Phone: (518) 862-1090 Fax: (518) 862-1091 Vest Valley Site lanagement Program 10282 Rock Springs Road West Valley, NY 14171-9799 Phone: (716) 942-4387 Fax: (716) 942-2148 New York City 485 Seventh Ave., Suite 1006 New York, NY 10018 Phone: (212) 971-5342 Fax: (212) 971-5349 Buffalo 617 Main Street, Suite 105 Buffalo, NY 14203 Phone: (716) 842-1522 Fax: (716) 842-1835

Messrs. Gillen, Giardina & Dassatti Page 2 May 13, 2003 copy the cooperating agencies on comments submitted to the U.S. Department of Energy (DOE) on facility inventory and characterization reports.

If you have any questions you may contact me or Colleen Gervitz at (716) 942-4378 or 4435, respectively.

Sincerely, WEST VALLEY SITE MANAGEMENT PROGRAM Paul L. Piciulo, Ph.D.

Director PLP/amd

Attachment:

Letter, Paul L. Piciulo, Ph.D., Director, to Alice C. Williams, Director, NYSERDA Comments on "Acid Recovery Pump Room Radioisotope Inventory Report, RIR-403-005, Revision 0, dated 09/27/2002" cc:

H. Brodie, NYSERDA-Albany (w/att.)

A. L. Mellon, NYSERDA-WV (w/att.)

C. L. Gerwitz, NYSERDA-WV (w/att.)

T. L. Sonntag, NYSERDA-WV (w/att.)

P. J. Bembia, NYSERDA-WV (w/att.)

A. C. Williams, DOE-WVDP (w/att.)

J. J. Kottan, NRC-Region I (w/att.)

PLP/03amd033.clg

NYSERDA New York State Energg Research and Development Authority Vincent A. Delorio, Esq., Chairman Toll Free: 1 (866) NYSERDA www.nyserda.org info@nyserda.org May 13,2003 Alice C. Williams Director U.S. Department of Energy -

West Valley Demonstration Project 10282 Rock Springs Road West Valley, NY 14171-9799

Dear Ms. Williams:

SUBJECT:

Comments on Acid Recovery Pump Room Revision 0, dated 09/27/2002 Radioisotope Inventory Report, RIR-403-005, The New York State Energy Research and Development Authority (NYSERDA) is providing the attached comments on theAcidRecoveryPumpRoomRadioisotopeInventoryReport, RIR-403-005, Revision 0, dated 09/27/2002 (ARPR Report). We are requesting written responses to the seven comments that are attached and that the ARPR Report be revised to address our comments.

Due to the importance of facility characterization activities in determining the residual source term for the WVDP, NYSERDA believes that characterization data and reports, such as the ARPR Report, need to be of a high quality. Our comments are submitted for the purpose of improving the quality of the product.

NYSERDA will continue to review and provide comments on the various inventory reports to you and the cooperating agencies.

Main Office Albany 17 Columbia Circle Albany, NY 12203-6399 Toll Free:

(866) NYSERDA Phone: (518) 862-1090 Fax: (518) 862-1091 West Valley Site Mlanagement Program 10282 Rock Springs Road West Valley, NY 14171-9799 Phone: (716) 942-4387 Fax: (716) 942-2148 New York City 485 Seventh Ave., Suite 1006 New York, NY 10018 Phone: (212) 971-5342 Fax: (212) 971-5349 Buffalo 617 Main Street, Suite 105 Buffalo, NY 14203 Phone: (716) 842-1522 Fax: (716) 842-1835

Ms. Alice Williams Page 2 May 13, 2003 If you have any questions, please contact me or Andrea Mellon at extensions 4378 or 4054, respectively.

Sincerely, WEST VALLEY SITE MANAGEMENT PROGRAM Paul L. Piciulo, Ph.D.

Director PLP/amd

Attachment:

NYSERDA Comments on Acid Recovery Pump Room Radioisotope Inventory Report, RIR-403-005, Revision 0, dated 09/27/2002 cc:

H. Brodie, NYSERDA-Albany (w/att.)

A. L. Mellon, NYSERDA-WV (w/att.)

C. L. Gerwitz, NYSERDA-WV (w/att.)

T. L. Sonntag, NYSERDA-WV (w/att.)

P. J. Bembia, NYSERDA-WV (w/att.)

D. M. Gillen, NRC-TWFN (w/att.)

E. E. Dassatti, NYSDEC (w/att.)

P. A. Giardina, USEPA (w/att.)

J. E. Loving, USDOE-EH-42 (w/att.)

C. D. Monroe, USDOE-GC-51 (w/att.)

M. W. Frei, USDOE-EM-30 (w/att.)

R. R. Warther, USDOE-OH (w/att.)

PLP/03amd032.clg

-NYSERDA Comments Acid Recovery Pump Room Radioisotope Inventory Report, RIR-403-005, Revision 0, dated 09/27/2002

1.

The introduction to the AcidRecoveryPiimp Room RadioisotopeInventoryReport, IR-403-005, Revision 0, dated 9/27/2002 (ARPR Report) states that the report provides "a conservatively bounded curie inventory." Considering the following comments, please explain the basis for asserting that the curie inventory presented in the ARPR Report is "conservatively bounding" and provide an estimate of the uncertainty associated with the ARPR curie estimate.

2.

Considering the many different dissolving, stripping and extraction steps where nitric acid was used to achieve isotope separation and purification in the fuel reprocessing operations and that the nitric acid from these many different steps were recycled back thuough-the ARPR, it would seem reasonable to expect to encounter many different isotopic distributions within this room. Please modifythe report to explain the basis for assuming a single isotopic

-distribution for the residual ARPR source term.

3.

Decontamination activities that occurred in the ARPR in 2001 are described in a report entitledAcidRecoveryPumpRoom (ARPR)DecontaminationProject, April 30,2001, which is included as Attachment B to the ARPR Report. In Section 3.3 of Attachment B, West Valley Nuclear Services Company (WVNSCO) states that, contrary to their initial assumption that all waste from the ARPR would have one radiological signature, initial screening samples from the ARPR indicated that "...multiple radiological distributions could be present." WVNSCO took additional samples from the floor in areas that were higher in activity and the report states that "... these samples showed a large variance in the radiological distribution between actinides and fission products."

Regardless of this acknowledgment that multiple radiological distributions existed within the ARPR, a single radiological distribution (e.g., the Table 2 scaling factors) was used to generate the curie estimate for the ARPR. Please revise the report to reconcile or otherwise explain this apparent inconsistency.

4.

The analytical results of characterization samples described in Section 3.3 of Attachment B were not included in the ARPR Report. Please revise the report to include these sample results and provide an explanation for exclusively using the mean of the three floor debris samples as opposed to the characterization samples to establish the residual radiological distribution (i.e, Table 2 scaling factors).

5.

Please revise the report to include a technical justification for using the geometric mean instead of the arithmetic mean to calculate the ARPR scaling factors.

6.

Microshield modeling of the ARPR was perforned using dose rates from 24 locations (post-grouting dose rates) that were obtained after grout and a lead blanket were installed in the ARPR. "Pre-grouting" dose rates for these same 24 locations are available and could be used as inputs for the Microshield modeling of the ARPR. The Microshield modeling results using the pre-grouting dose rates should be reported in the ARPR Report, and compared with Page I of 2

the post-grouting Microshield modeling results to verify shielding assumptions introduced in the model.

7.

Based on the total metals analytical results for the ARPR floor debris (Attachment E) all three drums would appear to be RCRA characteristic for various metals, as follows:

Drum #1 - RCRA characteristic for chromium (136 ppm), lead (22,600 ppm) and mercury (4.6 ppm).

Drum #2 - RCRA characteristic for lead (1,080 ppm).

Drum #3 - RCRA characteristic for chromium (106 ppm) and lead (6,850 ppm).

The ARPR Report does not address RCRA characterization; but based on the cement debris results, it seems likely that residual RCRA hazardous waste constituents are present in the ARPR floor (and possibly-the walls). The ARPR floor has already-been covered with 8 inches of grout which will impede additional characterization efforts. RCRA hazardous waste characterization of the ARPR should be fully documented in this report or in a companion report. Actions which inhibit the collection of additionai characterization data (e.g., grouting) should be minimized or avoided until the information has been provided to the regulatory agencies.

Page 2 of 2 I