ML031490708
| ML031490708 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 05/28/2003 |
| From: | Marshall M NRC/NRR/DLPM/LPD2 |
| To: | Scalice J Tennessee Valley Authority |
| Marshall M, NRR/DLPM/301- 415-2734 | |
| References | |
| TAC MB7505 | |
| Download: ML031490708 (4) | |
Text
May 28, 2003 Mr. J. A. Scalice Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
SUBJECT:
SEQUOYAH NUCLEAR PLANT, UNIT 1 - REVIEW OF STEAM GENERATOR TUBE INSPECTION
SUMMARY
REPORTS FOR 2001 OUTAGE (TAC NO. MB7505)
Dear Mr. Scalice:
In letters dated November 20, 2001, February 11, 2002, February 13, 2002, March 25, 2002, and October 25, 2002, the Tennessee Valley Authority (TVA) submitted steam generator tube inspection reports for their 2001 tube inspection at Sequoyah Nuclear Plant, Unit 1 (SQN1) to the U.S. Nuclear Regulatory Commission (NRC). These inspection reports were submitted in accordance with the SQN1 Technical Specifications.
Based on a review of the material provided by TVA, the NRC staff concludes that the licensee provided sufficient information and that there are not any issues that warrant additional follow-up at this time. No formal summary of the NRC staff review was prepared since TVA was in the process of replacing the SQN1 steam generators during the time of the review and no issues were identified.
If you have any questions concerning the NRC staff review of the steam generator tube inspection reports, please contact me at (301) 415-2734.
Sincerely,
/RA/
Michael L. Marshall, Jr., Senior Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-327 cc: See next page
ML031490708 OFFICE PDII-2/PM PDII-2/LA PDII-2/SC NAME MMarshall BClayton AHowe DATE 05/28/03 05/28/03 05/28/03
Mr. J. A. Scalice SEQUOYAH NUCLEAR PLANT Tennessee Valley Authority cc:
Mr. Karl W. Singer, Senior Vice President Nuclear Operations Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. James E. Maddox, Vice President Engineering & Technical Services Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Richard T. Purcell Site Vice President Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37379 General Counsel Tennessee Valley Authority ET 11A 400 West Summit Hill Drive Knoxville, TN 37902 Mr. Robert J. Adney, General Manager Nuclear Assurance Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Mark J. Burzynski, Manager Nuclear Licensing Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Mr. Pedro Salas, Manager Licensing and Industry Affairs Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37379 Mr. D. L. Koehl, Plant Manager Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37379 Senior Resident Inspector Sequoyah Nuclear Plant U.S. Nuclear Regulatory Commission 2600 Igou Ferry Road Soddy Daisy, TN 37379 Mr. Lawrence E. Nanney, Director Division of Radiological Health Dept. of Environment & Conservation Third Floor, L and C Annex 401 Church Street Nashville, TN 37243-1532 County Executive Hamilton County Courthouse Chattanooga, TN 37402-2801 Ms. Ann P. Harris 341 Swing Loop Road Rockwood, Tennessee 37854