NMCe Committed to Nuclear Excellence Palisades Nuclear Plant Operated by Nuclear Management Company, LLC April 22, 2003 U S Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 PALISADES NUCLEAR PLANT DOCKET 50-255 LICENSE No. DPR-20 2003 STEAM GENERATOR TUBE SURVEILLANCE REPORT - TUBES PLUGGED Nuclear Management Company, LLC completed an inservice inspection of the Palisades steam generator tubes on April 10, 2003. Palisades Technical Specification 5.6.8.a requires that the number of tubes plugged in each steam generator be reported within fifteen days following the completion of the inservice inspection.

Twenty-five tubes were plugged in steam generator E-50A and twenty-one tubes were plugged in steam generator E-50B. The total number of tubes plugged in steam generator E-50A is 365. The total number of tubes plugged in steam generator E-50B is 360.

SUMMARY

OF COMMITMENTS This letter contains no new commitments and no revisions to existing commitments.

N.

Dougls E. Cooper Site Vice-President, Palisades CC Regional Administrator, USNRC, Region IlIl Project Manager, USNRC, NRR NRC Resident Inspector - Palisades 27780 Blue Star Memorial Highway

  • Covert, Ml 49043 Telephone. 616 764.2000