ML031150748
| ML031150748 | |
| Person / Time | |
|---|---|
| Site: | South Texas |
| Issue date: | 04/25/2003 |
| From: | Kalyanam N NRC/NRR/DLPM/LPD4 |
| To: | Gramm R NRC/NRR/DLPM/LPD4 |
| Kalyanam N, NRR/DLPM, 415-1480 | |
| Shared Package | |
| ml031220346 | List: |
| References | |
| Download: ML031150748 (7) | |
Text
April 25, 2003 MEMORANDUM TO: Robert A. Gramm, Chief, Section 1 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation FROM:
N. Kalyanam, Project Manager, Section 1
/RA/
Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation
SUBJECT:
SUMMARY
OF MEETING HELD ON APRIL 15, 2003, WITH SOUTH TEXAS PROJECT NUCLEAR OPERATING COMPANY (STPNOC), RE:
RISK-BASED PROPOSAL FOR ALTERNATIVE SELECTION CRITERIA FOR CONTAINMENT TENDON TESTING AT SOUTH TEXAS PROJECT, UNITS 1 AND 2 (STP 1 AND 2)
On April 15, 2003, the U.S. Nuclear Regulatory Commission (NRC) staff held a meeting with representatives of STPNOC. The meeting was held at NRC headquarters in Rockville, Maryland. The purpose of the meeting was to discuss a risk-based proposal for alternative selection criteria for containment tendon testing at STP 1 and 2. The agenda for the meeting was provided and attached to the meeting notice dated April 1, 2003.
Based on the discussion, STPNOC will submit a relief request from the requirements of 10 CFR 50.55a that would help them with the hardship associated with conducting tendon lift-off tests. STPNOC may, in future, request a relief from certain requirements based on risk insights. For the immediate relief request, NRC requested the licensee to keep the deviation from the 10 CFR 50.55a requirements to a minimum.
The handout from STPNOC is included as Attachment 1 to this letter. A list of the attendees is in Attachment 2.
Docket Nos.: 50-498 and 50-499 Attachments: 1. Meeting Handout
- 2. List of Attendees cc: See next page
ML031150748 Package No.: ML03 OFFICE PDIV-1/PM PDIV-1/LA PDIV-1/SC NAME NKalyanam MMcAllister RGramm DATE 4/24/2003 4/24/2003 4/25/2003
ATTENDANCE LIST FOR MEETING BETWEEN NUCLEAR REGULATORY COMMISSION (NRC) AND SOUTH TEXAS PROJECT NUCLEAR OPERATING COMPANY (STPNOC)
APRIL 15, 2003 Name Organization Bill Stillwell STPNOC Jorma Arros ABS Consulting Philip Walker STPNOC Mark Kanavos STPNOC Scott Head STPNOC Mark Wales STPNOC Robert Gramm NRC Mark Rubin NRC Robert Palla NRC Hans Ashar NRC Herman Graves NRC N. Kalyanam NRC
September 2002 South Texas, Units 1 & 2 cc:
Mr. Cornelius F. OKeefe Senior Resident Inspector U.S. Nuclear Regulatory Commission P. O. Box 910 Bay City, TX 77414 A. Ramirez/C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 Mr. M. T. Hardt Mr. W. C. Gunst City Public Service Board P. O. Box 1771 San Antonio, TX 78296 Mr. C. A. Johnson/R. P. Powers AEP - Central Power and Light Company P. O. Box 289 Mail Code: N5022 Wadsworth, TX 77483 INPO Records Center 700 Galleria Parkway Atlanta, GA 30339-3064 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011 D. G. Tees/R. L. Balcom Texas Genco, LP P. O. Box 1700 Houston, TX 77251 Judge, Matagorda County Matagorda County Courthouse 1700 Seventh Street Bay City, TX 77414 A. H. Gutterman, Esq.
Morgan, Lewis & Bockius 1111 Pennsylvania Avenue, NW Washington, DC 20004 Mr. T. J. Jordan, Vice President Engineering & Technical Services STP Nuclear Operating Company P. O. Box 289 Wadsworth, TX 77483 S. M. Head, Manager, Licensing Nuclear Quality & Licensing Department STP Nuclear Operating Company P. O. Box 289, Mail Code: N5014 Wadsworth, TX 77483 Environmental and Natural Resources Policy Director P. O. Box 12428 Austin, TX 78711-3189 Jon C. Wood Matthews & Branscomb 112 East Pecan, Suite 1100 San Antonio, TX 78205 Arthur C. Tate, Director Division of Compliance & Inspection Bureau of Radiation Control Texas Department of Health 1100 West 49th Street Austin, TX 78756 Brian Almon Public Utility Commission William B. Travis Building P. O. Box 13326 1701 North Congress Avenue Austin, TX 78701-3326
South Texas, Units 1 & 2 Susan M. Jablonski Office of Permitting, Remediation and Registration Texas Commission on Environmental Quality MC-122 P.O. Box 13087 Austin, TX 78711-3087 G. R. Bynog, Program Manager/
Chief Inspector Texas Department of Licensing and Regulation Boiler Division P. O. Box 12157, Capitol Station Austin, TX 78711 Mr. Ted Enos 4200 South Hulen Suite 630 Ft. Worth, Texas 76109 Mr. William T. Cottle President and Chief Executive Officer STP Nuclear Operating Company South Texas Project Electric Generating Company P.O. Box 289 Wadsworth, Texas 77483