PHYSICS TESTS Exceptions - MODE 2 3.1.8 3.1 REACTIVITY CONTROL SYSTEMS 3.1.8 PHYSICS TESTS Exceptions - MODE 2 LCO 3.1.8 APPLICABILITY:

During the performance of PHYSICS TESTS, the requirements of LCO 3.1.3, "Moderator Temperature Coefficient (MTC)";

LCO 3.1.4, "Rod Group Alignment Limits";

LCO 3.1.5, "Shutdown Bank Insertion Limits";

LCO 3.1.6, "Control Bank Insertion Limits"; and LCO 3.4.2, "RCS Minimum Temperature for Criticality" may be suspended and the number of required channels for LCO 3.3.1, "RTS Instrumentation," Functions 2, 3, 6, and 18.e, may be reduced to 3 required channels, provided:

a.

RCS lowest operating loop average temperature is 2 541OF;

b.

SDM is within the limits provided in the COLR; and

c.

THERMAL POWER is

MODE 2 during PHYSICS TESTS.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

SDM not within limit.

A.1 Initiate boration to restore 15 minutes SDM to within limit.

AND A.2 Suspend PHYSICS 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> TESTS exceptions.

B.

THERMAL POWER not B.1 Open reactor trip Immediately within limit.

breakers.

(continued)

Wolf Creek - Unit 1 3.1-19 Amendment No. 14-3, 151

PHYSICS TESTS Exceptions - MODE 2 3.1.8 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. RCS lowest operating loop C.1 Restore RCS lowest 15 minutes average temperature not operating loop average within limit.

temperature to within limit.

D. Required Action and D.1 Be in MODE 3.

15 minutes associated Completion Time of Condition C not met.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.1.8.1 Perform a CHANNEL OPERATIONAL TEST on Prior to initiation of power range and intermediate range channels per PHYSICS TESTS SR 3.3.1.8 and Table 3.3.1-1.

SR 3.1.8.2 Verify the RCS lowest operating loop average 30 minutes temperature is 2 5410F.

SR 3.1.8.3 Verify THERMAL POWER is < 5% RTP.

1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> SR 3.1.8.4 Verify SDM is within limits provided in the COLR.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Wolf Creek - Unit 1 3.1 -20 Amendment No. 123