ML030860373

From kanterella
Jump to navigation Jump to search
E-mail S. Long, NRR, to D. Snowberger, NRR, Et Al, Fwd: Draft SDP Review, W/Att e-mail 08/12/02 M. Johnson, NRR, to R.Caruso, NRR Et Al
ML030860373
Person / Time
Site: Davis Besse 
Issue date: 08/12/2002
From: Long S
Office of Nuclear Reactor Regulation
To: Snowberger D, Valentine T
Office of Nuclear Reactor Regulation
References
FOIA/PA-2003-0018
Download: ML030860373 (2)


Text

From:

Steven Long To:

ItJ"* wight Snowberger; Theresa Valentine Date:

8/12/02 9"44AM

Subject:

Fwd. DRAFT SDP REVIEW FYI A'I

[ Steven Long,- Fwd. DRAFT SDP REVIEW

-P,6§e 11

From:

Michael Johnson To:

Caruso, Ralph; Cullen, William, Demoss, Gary; Dinsmore, Stephen; Jain, Bhagwat; Kirk, Mark, Marksberry, Don; Norris, Wallace; Parry, Gareth Date:

8/12/02 6.36AM

Subject:

DRAFT SDP REVIEW Before beginning the concurrence process for the SDP report for the Davis-Besse performance deficiency, we are performing a technical review of the draft analysis Steve Long has distributed draft copies of the analysis to each of you. We requested either review of particular sections where he has used your inputs or, by some, a review of the overall approach and the logic used for quantification.

Please provide your comments directly back to Steve as soon as you can In addition, I am requesting your participation in a meeting to provide an opportunity to discuss the draft and gauge the degree of technical concensus on the analysis and results. The meeting will be in Room 09-B6 at I pm on Tuesday, August 13th Black, Suzanne; Holahan, Gary, Long, Steven i _Steven Long..- DRA*FT SDP REVIEW Page I1 CC: