Mar.
12, 2003 Page 1
of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2003-11652 USER INFORMATION:
GERCH*ROSE EMPL#:28401 CA#: 0363 Addres CSA2 Phon
- 2<53194' TRANSMITTAL INFORMATION:
TO:
GERLACII'tROSF M
03/12/2003 LOCATION:
DOCUMENT CONTROL DESK FROM:
NUCLEAR RECORDS DOCUMENT CONTROL CENTER NUCSA-2)
ý..3HE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU:
115 115 CHEMISTRY SAMPLING TEAM:
EMERGENCY PLAN-POSITION SPECIFIC PROCEDURE REMOVE MANUAL TABLE OF CONTENTS DATE: 02/05/2003 ADD MANUAL TABLE OF CONTENTS DATE: 03/11/2003 CATEGORY:
PROCEDURES TYPE:
.ID:
EP-PS-115 REPLACE:
REV:13 REPLAC REMOVE ADD:
P Tab J: Add Page 5 Only
- UPDATE,
- LL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE w'irH DEPARTMENT PROCEDURES.
PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY.
FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
3/4A04S
TAB J EP-PS-115-J Revision 6 Page 5 of 7 ATTACHMENT A DISSOLVED GAS SAMPLE ANALYSIS DISSOLVED GAS SAMPLE ANALYSIS Sample Source Sample Date/Time Initial Sample Gas Pressure (P.) PI-662 psia Temperature TI-660 OF Final Sample Gas Pressure (Pf) PI-662 psia j Contact Dose Rate mR/hr II.
GAS CHROMATOGRAPH ANALYSIS Analysis Date/Time CTE #
Oxygen (Co)
Nitrogen Ill.
DISSOLVED GAS CONCENTRATIONS Total Dissolved Gas Concentration:
=
MFT X [Pf - (1.05 x Po) - Pv]
Sx x
(1.05x
=
scc/kg WHERE:
=
Total Dissolved Gas Concentration (scc/kg)
MFT
=
Multiplication Factor for gas and liquid loop volumes Unit 1: 6.33 Unit 2: 8.33 Pf
=
Final Sample Gas Pressure PI-662 (psia)
P
=
Initial Sample Gas Pressure PI-662 (psia)
P
=
Liquid vapor pressure of sample @ temperature TI-660 from Attachment B Dissolved Hydrogen Concentration:
=
(MFH) x (% H2) x (Pf)
=
x)x(
)x (TI-660 °F + 460)
L_.._
+ 460)
=
scc/kg WHERE:
=
Dissolved Hydrogen Concentration (scc/kg)
MFH
=
Multiplication Factor Unit 1: 48.6 Unit 2: 63.31
%H2=
Percent hydrogen from gas chromatograph analysis Pf
=
Final Sample Gas Pressure PI-662 (psia)
TI-660 =
Temperature (OF) at TI-660 EP-AD-000-146, Rev. 3, Page 1 of 2