ES-401 Written Examination Form ES-401-9 (R8, Si)
Review Worksheet CALLAWAY 7/2002
- 1.
- 2.
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
- 7.
Q#
LOK LOD II I
1 I° (F/H)
(1-5)
Stem Cues T/F Cred. Partial Job-Minutia
- /
Back-Q=
SRO UIE/S Explanation Focus Dist.
Link units I ward K/A I Only R1 F
2 S
t R2 F
2 S
R3 F
3 S
R4 F
3 S
t R5 H
3 S
R6 F
3 S
R7 H
3 S
R8 H
3 S
R9 F
3 S
R10 H
3 S
Instructions
[Refer to Section D of ES-401 and Appendix B for additional information regarding each of the following concepts.]
- 1.
Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.
- 2.
Enter the level of difficulty (LOD) of each question using a 1 - 5 (easy - difficult) rating scale (questions in the 2 - 4 range are acceptable).
- 3.
Check the appropriate box if a psychometric flaw is identified:
The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information).
The stem or distractors contain cues (i.e., clues, specific determiners, phrasing, length, etc).
The answer choices are a collection of unrelated true/false statements.
More than one distractor is not credible.
One or more distractors is (are) partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by stem).
- 4.
Check the appropriate box if a job content error is identified:
The question is not linked to the job requirements (i.e., the question has a valid K/A but, as written, is not operational in content).
The question requires the recall of knowledge that is too specific for the closed reference test mode (i.e., it is not required to be known from memory).
The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).
The question requires reverse logic or application compared to the job requirements.
- 5.
Check questions that are sampled for conformance with the approved K/A and those that are designated SRO-only (K/A and license level mismatches are unacceptable).
- 6.
Based on the reviewer's judgment, is the question as written (U)nacceptable (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?
- 7.
At a minimum, explain any "U" ratings (e.g., how the Appendix B psychometric attributes are not being met).
Page 1 of 6
ES-401 2
Form ES-401-9 (R8, Si)
- 1.
- 2.
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
- 7.
Q#
LOK LOD (F/H)
(1-5)
Stem Cues T/F Cred. Partial Job-Minutia
- /
Back-Q=
SRO U/E/S Explanation Focus Dist.
Link units ward K/A Only R11 H
3 S
R12 H
3 S
R13 H
3 S
R14 H
3 S
t Ri15 F
3 S
R16 F
3 S
R17 F
3 S
R18 F
3 S
R19 H
3 S
R20 H
3 5
t R21 F
2 S
R22 F
2 S
R23 F
4 S
t R24 F
3 S
R25 F
3 S
S1 F
3 S
S2 F
3 S
Reference in stem should be to step 5 of FR-S.1 S3 F
3 S
t S4 F
3 S
S5 H
3 S
S6 H
3 S
t S7 F
3 V
E Provide a lower RWST level for Distractor D Page 2 of 6
- 1.
- 2.
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
- 7.
Q#
LOK LOD (F/H)
(1-5)
Stem Cues T/F Cred. Partial Job-Minutia
- /
Back-Q=
SRO U/E/S Explanation Focus Dist.
Link units ward K/A Only 88 F
3 S
t S9 F
3 S
S10 H
3 S
S11 H
3 S
S12 F
3 S
S13 F
3 S
814 H
3 S
S15 H
4 S
t 816 F
3 S
S17 F
3 S
t S18 F
3 S
819 F
3 S
S20 H
3 S
S21 F
3 S
s22 F
3 S
S23 F
3 S
824 H
3 S
825 F
2 S
B1 H
3 S
B2 F
3 S
B3 H
3 S
t B4 H
3 S
B5 H
3 S
B6 F
3 S
B7 H
3 S
B8 H
2 S
Page 3 of 6
- 1.
- 2.
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
- 7.
Q#
LOK LOD (F/H)
(1-5)
Stem Cues T/F Cred. Partial Job-Minutia
- /
Back-Q=
SRO U/E/S Explanation Focus Dist.
Link units ward K/A Only B9 H
3 S
B10 H
3 1
S t Where is expectation that students know battery capacity?
B1l F
3 S
B12 F
3 S
B13 H
3 S
B14 F
3 S
B15 F
3 S
B16 F
3 S
B17 H
3 S
It B18 H
3 S
B19 H
3 S
B20 H
3 S
t B21 H
3 S
t B22 F
3 S
B23 F
3 S
B24 H
3 S
B25 H
3 S
B26 H
3 S
B27 H
3 S
t B28 H
3 S
t B29 H
3 S
B30 F
3 S
831 F
3 S
B32 H
3 S
B33 H
3 S
B34 H
3 S
t Page 4 of 6
- 1.
- 2.
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
- 7.
Q#
LOK LOD (F/H)
(1-5)
Stem Cues T/F Cred. Partial Job-Minutia
- /
Back-Q=
SRO U/E/S Explanation Focus Dist.
Link units ward K/A Only B35 H
3 E
Clarify Distractor C and Answer D to indicate this alarm comes in after subsequent inward rod movement. One is led to believe that the alarm is recieved as a result of the rod recovery.
B36 H
3 S
B37 H
3 S
t B38 H
4 S
t B39 H
3 S
B40 H
3 S
841 H
3 S
B42 H
3 S
B43 H
3 S
B44 H
3 S
t 845 H
2 S
B46 F
3 S
B47 F
2 S
B48 F
3 S
t B49 H
3 S
850 F
3 S
851 H
3 S
B52 H
4 S
t B53 H
4 E
t Containment pressure @ 10 psig and increasing 1 psig per minute does not appear to be consistent with CSAS @ 27 psig. Clarify initial conditions and subsequent pressure increase.
854 F
3 S
855 H
3 S
t B56 H
3 S
B57 H
3 S
B58 H
3 S
Page 5 of 6
- 1.
- 2.
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
- 7.
Q#
LOK LOD (F/H)
(1-5)
Stem Cues T/F Cred. Partial Job-Minutia
- /
Back-Q=
SRO U/E/S Explanation Focus Dist.
Link units ward K/A Only B59 F
3 S
B60 H
3 S
B61 F
2 S
t B62 H
3 S
t B63 F
3 S
B64 F
2 S
B65 H
3 S
t B66 F
2 S
t B67 F
3 S
B68 F
2 S
B69 F
3 S
B70 F
2 S
B71 F
2 S
t B72 F
3 S
B73 H
3 S
B74 H
3 S
B75 H
3 S
tReviewed as part of initial 30 question sample Page 6 of 6