Inspection/Activity Plan for 03/01/2003 - 03/30/2004
ML030660199
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 03/03/2003
From: Joel Munday
NRC/RGN-II/DRP/RPB3
To: Stall J
Florida Power & Light Co
Shared Package
ML030660199 List:
References
IR-03-001
Download: ML030660199 (3)


Text

Turkey Point Inspection / Activity Plan 03/01/2003 - 03/30/2004 Inspection Type Planned Dates Start End Title Inspection Activity No. of Staff on Site Unit Number Page 1 of 3 02/20/2003 14:51:42 Report 22 1

EB2-ISI

- INSERVICE INSPECTION-U3 03/03/2003 03/07/2003 Baseline Inspections Inservice Inspection Activities - PWR IP 7111108P 3

Comments:

1 2515/150

- 2515/150 REV 1 UNIT 3 03/05/2003 03/07/2003 Safety Issues Reactor Pressure Vessel Head and Vessel Head Penetration Nozzles (NRC Bulletin 2002-0 IP 2515/150 3

Comments:

1 S/G-ISI

- S/G INSERVICE INSPECTION-U3 03/10/2003 03/12/2003 Baseline Inspections Inservice Inspection Activities - PWR IP 7111108P 3

Comments:

3 PS-SEC

- SECURITY - TI/ICM 03/31/2003 04/04/2003 Safety Issues Inspection of Nuclear Reactor Safeguards - Interim Compensatory Measures IP 2515/148 3, 4 Comments:

3 PS-RP

- RADIATION PROTECTION 10/06/2003 10/10/2003 Baseline Inspections Access Control to Radiologically Significant Areas IP 7112101 3, 4 10/06/2003 10/10/2003 Baseline Inspections ALARA Planning and Controls IP 7112102 3, 4 10/06/2003 10/10/2003 Baseline Inspections Radioactive Material Processing and Transportation IP 7112202 3, 4 10/06/2003 10/10/2003 Baseline Inspections Performance Indicator Verification IP 71151 3, 4 Comments:

1 EB2-ISI

- INSERVICE INSPECTION-U4 10/13/2003 10/17/2003 Baseline Inspections Inservice Inspection Activities - PWR IP 7111108P 4

Comments:

This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.

Turkey Point Inspection / Activity Plan 03/01/2003 - 03/30/2004 Inspection Type Planned Dates Start End Title Inspection Activity No. of Staff on Site Unit Number Page 2 of 3 02/20/2003 14:51:42 Report 22 1

2515/150

- 2515/150 REV 1 UNIT 4 10/13/2003 10/17/2003 Safety Issues Reactor Pressure Vessel Head and Vessel Head Penetration Nozzles (NRC Bulletin 2002-0 IP 2515/150 4

Comments:

1 S/G-ISI

- S/G INSERVICE INSPECTION-U4 10/20/2003 10/22/2003 Baseline Inspections Inservice Inspection Activities - PWR IP 7111108P 4

Comments:

2 PS-RP

- RADIATION PROTECTION 10/20/2003 10/24/2003 Baseline Inspections Access Control to Radiologically Significant Areas IP 7112101 3, 4 10/20/2003 10/24/2003 Baseline Inspections ALARA Planning and Controls IP 7112102 3, 4 10/20/2003 10/24/2003 Baseline Inspections Radioactive Material Processing and Transportation IP 7112202 3, 4 10/20/2003 10/24/2003 Baseline Inspections Performance Indicator Verification IP 71151 3, 4 Comments:

2 OL PREP

- INITIAL EXAM PREP 11/03/2003 11/07/2003 Not Applicable TURKEY POINT/EXAMS AT POWER FACILITIES V23209 3

Comments:

1 EB2-HS

- HEAT SINK 12/08/2003 12/12/2003 Baseline Inspections Heat Sink Performance IP 7111107B 3, 4 Comments:

2 OL EXAM

- INITIAL EXAM 12/08/2003 12/19/2003 Not Applicable TURKEY POINT/EXAMS AT POWER FACILITIES V23209 3

Comments:

This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.

Turkey Point Inspection / Activity Plan 03/01/2003 - 03/30/2004 Inspection Type Planned Dates Start End Title Inspection Activity No. of Staff on Site Unit Number Page 3 of 3 02/20/2003 14:51:42 Report 22 4

EB1FP

- TFP PRE-INSPECTION VISIT 01/04/2004 01/09/2004 Baseline Inspections Fire Protection IP 7111105T 3, 4 Comments:

2 OL EP

- EP INSPECTION 01/26/2004 01/30/2004 Baseline Inspections Alert and Notification System Testing IP 7111402 3, 4 01/26/2004 01/30/2004 Baseline Inspections Emergency Response Organization Augmentation Testing IP 7111403 3, 4 01/26/2004 01/30/2004 Baseline Inspections Emergency Action Level and Emergency Plan Changes IP 7111404 3, 4 01/26/2004 01/30/2004 Baseline Inspections Correction of Emergency Preparedness Weaknesses and Deficiencies IP 7111405 3, 4 01/26/2004 01/30/2004 Baseline Inspections Performance Indicator Verification IP 71151 3, 4 Comments:

2 OL RQ

- REQUAL INSPECTION 01/26/2004 01/30/2004 Baseline Inspections Licensed Operator Requalification IP 7111111B 3, 4 Comments:

4 EB1-FP

- TRIENNIAL FIRE PROTECTION 01/26/2004 01/30/2004 Baseline Inspections Fire Protection IP 7111105T 3, 4 02/09/2004 02/13/2004 Baseline Inspections Fire Protection IP 7111105T 3, 4 Comments:

1 EB2-MR

- MAINTENANCE RULE 02/23/2004 02/27/2004 Baseline Inspections Maintenance Effectiveness IP 7111112B 3, 4 Comments:

This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.