OUTLINE SUBMITTAL FOR THE DRESDEN RETAKE EXAMINATION - JAN 2003
Outline Submittal Contains the following:
Outline Submittal Letter from Licensee ES-201 -1 Examination Preparation Checklist Letter Exelon cover letter transmitting the Outline ES-201-2 Examination Outline Quality Checklist ES-301-5 Transient and Event Checklist ES-301-6 Competencies Checklist D-1 Dynamic Simulator Scenario Outline for 3 scenarios Admin There were no NRC Comments on the submitted test outlines
ES-201 Examination Preparation Checklist Form ES-201-1 Facility: Dresden U2/U3 Date of Examination: 01/22/2003 Examinations Developed by: i clity/ NRC (circle one)
Target Chief Date* Task Description / Reference Examiner's Initials
-180 1. Examination administration date confirmed (C.l.a; C.2.a & b) drm
-120 2. NRC examiners and facility contact assigned (C.l.d; C.2.e) drm
-120 3. Facility contact briefed on security & other requirements (C.2.c) drm
-120 4. Corporate notification letter sent (C.2.d) drm
[-901 [5. Reference material due (C.1 .e; C.3.c)] n/a
-75 6. Integrated examination outline(s) due (C.1.e & f; C.3.d) drm
-70 7. Examination outline(s) reviewed by NRC and feedback provided drm to facility licensee (C.2.h; C.3.e)
-45 8. Proposed examinations, supporting documentation, and reference materials due (C.1 .e, f, g & h; C.3.d) drm
-30 9. Preliminary license applications due (C.1 .1; C.2.g; ES-202) drm
-14 10. Final license applications due and assignment sheet prepared drm (C.1.1; C.2.g; ES-202)
-14 11. Examination approved by NRC supervisor for facility licensee drm review (C.2.h; C.3.f)
-14 12. Examinations reviewed with facility licensee (C.1.j; C.2.f & h; C.3.g) drm
-7 13. Written examinations and operating tests approved by drm NRC supervisor (C.2.i; C.3.h)
-7 14. Final applications reviewed; assignment sheet updated; waiver drm letters sent (C.2.g, ES-204)
- 15. Proctoring/written exam administration guidelines reviewed with
-7 facility licensee and authorization granted to give written exams n/a (if applicable) (C.3.k)
-7 16. Approved scenarios, job performance measures, and questions drm distributed to NRC examiners (C.3.i)
Target dates are keyed to the examination date identified in the corporate notification letter.
They are for planning purposes and may be adjusted on a case-by-case basis in coordination with the facility licensee.
Applies only to examinations prepared by the NRC.
Exelkn,.
Exelon Generation www.exeloncorp.com Nuclear Dresden Generating Station 6500 North Dresden Road Morris, IL60450-9765 Tel 815-942-2920 10 CFR 55.40 November 11, 2002 RHLTR: #02-0085 U. S. Nuclear Regulatory Commission Region III ATTN: Operator Licensing Branch 801 Warrenville Road Lisle, IL 60532-4351 Dresden Nuclear Power Station Units 2 and 3 Facility Operating License Nos. DPR-19 and DPR-25 Docket Nos. 50-237 and 50-249
Subject:
Initial License Re-examination Integrated Examination Outline Enclosed is the integrated examination outline, which Dresden Nuclear Power Station (DNPS) is submitting for review, comment, and approval for the Initial License Examination, scheduled for the week of January 20, 2003, at DNPS.
This submittal includes outlines for the integrated operational scenarios.
This outline has been developed in accordance with NUREG-1021, "Operator Licensing Examiner Standards," Revision 8, Supplement 1.
In accordance with NUREG 1021, Section ES-201, please ensure that these materials are withheld from public disclosure until after the examinations are complete.
November 11, 2002 U. S. Nuclear Regulatory Commission Page 2 Should you have any questions concerning this letter, please contact Mr. Jeff Hansen, Regulatory Assurance Manager, at (815) 416-2800.
Respectfully, R. J. H ey Site Vice President Dresden Nuclear Power Station
Enclosures:
ES-201-2 Examination Outline Quality Checklist ES-201-3 Examination Security Agreements ES-301-5 Transient and Event Checklist ES-301-6 Competencies Checklist ES-D-1 Scenario Outlines cc: NRC Document Control Desk - w/o enclosures Region III NRC Regional Administrator - w/o enclosures NRC Senior Resident Inspector - Dresden Nuclear Station - w/o enclosures
bcc: Project Manager- NRR (Unit 2/3) w/o enclosures Officer of Nuclear Facility Safety - IDNS w/o enclosures Senior Reactor Analyst - NRC Region III w/o enclosures Manager of Energy Practice - Winston and Strawn w/o enclosures Director Licensing - MWROG w/o enclosures Manager Licensing Dresden and Quad Cities - MWROG w/o enclosures Station Manager - Dresden Nuclear Power Station w/o enclosures Regulatory Assurance Manager - Dresden Nuclear Power Station w/o enclosures Training Manager - Dresden Nuclear Power Station w/o enclosures Operations Manager - Dresden Nuclear Power Station w/o enclosures Shift Operations Superintendent - Dresden Nuclear Power Station w/o enclosures Operation Training Supervisor - Dresden Nuclear Power Station w/o enclosures R. Wroblewski - Initial License Training Specialist w/o enclosures M. Otten - Initial License Training Specialist w/o enclosures S. Russell - ROG Operator Licensing w/o enclosures Document Control Desk - Licensing (Hard Copy w/o enclosures)
Document Control Desk - Licensing (Electronic Copy)
Dresden Regulatory Assurance - Subject File w/o enclosures SVP Numerical File - RHLTR: #02-0085 w/o enclosures
ES-201 Examination Outline .---,Form ES-201-2 Quality Checklist m
j:I Faciliv Facility:, ,,.I ntls...
Item Task Description Initials 1.
I
- a. Verify that the outline(s) fit(s) the appropriate model per ES-401.
a b*Ic#
11 W
R b. Assess whether the outline was systematically and randomly prepared in accordance with I Section D.1 of ES-401 and whether all K/A categories are appropriately sampled.
T T c. Assess whether the outline over-emphasizes any systems, evolutions, or generic topics.
E N d. Assess whether the justifications for deselected or rejected K/A statements are appropriate.
- 2. a. Using Form ES-301-5, verify that the proposed scenario sets cover the required number of normal evolutions, instrument and component failures, and major transients.
S I b. Assess whether there are enough scenario sets (and spares) to test the projected number and M mix of applicants in accordance with the expected crew composition and rotation schedule without compromising exam integrity; ensure each applicant can be tested using at least one new or significantly modified scenario, that no scenarios are duplicated from the applicants' audit test(s)*,
and scenarios will not be repeated over successive days.
- c. To the extent possible, assess whether the outline(s) conform(s) with the qualitative and 440 quantitative criteria specified on Form ES-301-4 and described in Appendix D.
- 3. a. Verify that:
(1) the outline(s) contain(s) the required number of control room and in-plant tasks, W (2) no more than 30% of the test material is repeated from the last NRC examination,
/ - (3)* no tasks are duplicated from the applicants' audit test(s), and T (4) no more than 80% of any operating test is taken directly from the licensee's exam banks.
- b. Verify that:
(1) the tasks are distributed among the safety function groupings as specified in ES-301, (2) one task is conducted in a low-power or shutdown condition, (3) 40% of the tasks require applicant's (4) one in-plant task tests thethe applicant response to implement an alternate path to an emergency procedure, or abnormal condition, and (5) the in-plant walk-through requires the applicant to enter the RCA.
- c. Verify that the required administrative topics are covered, With emphasis on performance based activities.
- d. Determine if there are enough different outlines to test the projected number and mix of applicants and ensure that no items are duplicated on successive days.
- 4. a. Assess whether plant-specific priorities (including PRA and IPE insights) are covered in the appropriate exam section.
G E b. Assess whether the 10 CFR 55.41/43 and 55.45 sampling is appropriate.
N E c. Ensure that K/A importance ratings (except for plant-specific priorities) are at least 2.5. .4_0 R
A d. Check for duplication and overlap among exam s-ýctions. A_
- e. Check the entire exam for balance of coverage.
// ;ý5 ý gnature
- a. Author
- b. Facility Reviewer (*) " OS i, - __,_____
- c. NRC Chief Examiner(#) -t I (*,Mc~JfL CJC //4 ,f t 2
- d. NRC Supervisor ks ý t,, Y A
,A ""-,..
I
_J Note:
- Not applicable for NRC-developed examinations.
- Independent NRC reviewer initial items in Column "c;" chief examiner concurrence required.
23 of 24 NUREG-1021, Revision 8, Supplement 1
RO Instrument! 4 3,4-/ 3, 4* 51 3, 4*/
Component 5, 6* 6* 5, 6*
7 7 Major 1 7 Reactivity 1 Normal 0 As RO Instrument/ 2 Component Major 1 I
SRO-I Reactivity 0 Normal 1 As SRO Instrument/ 2 Component Maior 1 Reactivity 0 Normal 1 SRO-U Instrument / 2 Component I Major 1 Instructions: (1) Enter the operating test number and Form ES-D-1 event numbers for each evolution type.
(2) Reactivity manipulations may be condu, ted under normal or controlled abnormal conditions (refer to Section D.4.d) but must be significant per Section C.2.a of Appendix D.
(3) Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicant's competence count toward the minimum requirement.
Author:
NRC Reviewer: AO-"filf /'r//i f4-!4 NUREG-1 021, Revision 8, Supplement 1
Checklist Form ES-SO 1-6
- "... . . ES--30i Competencies Competencies Checklist- Form ES-301-6
(**plicant # 2
- lcn RO RO-I/SRO-U RB.O/RO-I/SRO-U Competencies SO Position -NSO Position SCENARIO SCENARIO ILT-R-1 ILT-R-2 ILT-R-3 ILT-R-1 ILT-R-2 ILT-R-3 Understand and Interpret 3,5,7-8 3, 5-8 3, 5, 7-8 4, 6-8 4,6-8 3-4,6-8 Annunciators and Alarms 4,_6-8_3-4,_6-8 Diagnose Events 3,5,7-8 3, 5-8 3, 5, 7-8 4, 6-8 and Conditions 4,_6-8 3-4,_6-8 Understand Plant 2,3,5, 1 3, 5-8 2-5,7-8 1, 3-4, 6 and System Response 7-8 1,4,6-8 2,4,6-8 8 Comply With and 2,3,5, 1-3, 5-8 2-5, 7-8 1,4,6-8 1, 3-4, 6 Use Procedures (1) 7-8 2,4,6-8 8 Operate Control 2-3, 5, 1, 3, 5, 2-3, 5, Boards 7-8 7-8 7-8 1, 4, 6-8 2, 4, 6-8 1, 4, 6-8 Communicate and Interact With the Crew 2-8 1-3, 5-8 2-8 1, 4-8 2, 4, 6-8 1, 3-8 Demonstrate Supervisory Ability (2) NIA NIA NIA NIA NIA NIA Comply With and Use Tech. Specs. (2) N/A N/A N/A N/A N/A N/A Notes:
(1) Includes Technical Specification compliance for an RO.
(2) Only applicable to SROs.
Instructions:
Circle the applicant's license type and enter one or more event numbers that will allow the examiners to evaluate every applicable competency for every applicant.
Author: 4954ý NRC Reviewer:
NUREG-1021, Revision 8, Supplement 1
Appendix D Scenario Outline Form ES-D-1 Facility: Dresden Scenario No: ILT-R-1 Op-Test No: ILT 01-1 Retest Examiners: Operators:
Initial Conditions: 15% reactor power, IRM channel 15 OOS, Unit 3 is in Mode 1 Turnover: Unit startup in progress; transfer auxiliary power to transformer 21, then continue power ascension.
Event Malfunction Event Event No. Number Type* Description 1NA N ANSO NA N SRO Transfer Aux power from TR-22 to TR-21 NSO 2NA R SO Raise reactor power by withdrawing control rods NSO 3 RDFAILF5 I SRO RPIS failure for rod F5 4 ANSO Failure of the main generator voltage regulator in MGMATMF I SRO automatic NSO 5 RRDMBSTP C SRO Trip of the 2B recirc pump ANSO Trip of the 2A circ water pump with a failure of the 2B circ 6
HP6 C SRO water pump to start B1 2 7 AW4 ALL Failure of RPS to deenergize and ARI to initiate M
S.... ANSO Loss of main condenser vacuum / Failure of SBLC to 8 HP5 SRO inject
- (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor
Appendix D Scenario Outline Form ES-D-1 Facility: Dresden Scenario No: ILT-R-2 Op-Test No: ILT 01-1 Retest Examiners: Operators:
Initial Conditions: Approximately 9.0 Mlbm/hr feedwater flow, IRM channel 15 OOS, Unit 3 is in Mode 1 Turnover: A downpower is in progress to remove the 2C RFP from service for maintenance.
Event Malfunction Event Event No. Number Type* Description 1NA R NSO R SNA SO Lower reactor power by reducing recirc flow ANSO NA N SRO Secure the 2C RFP NSO 3 RRMBUNST I SRO 2B Recirc pump speed signal failure
- -MRGCRDE.. ANSO 4
- MRGCRDE I NSRO Fails the east CRD area ARM downscale NSO 5 RDFCFHI I SRO Failure of the CRD flow control controller ANSO 0SRO Trip of the feed breaker to Bus 29 7 121 ALL Steam leak in the drywell 8 K23 M ANSO B12 SRO Loss of Bus 23-1 / RPS failure to scram
- (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor
S Appendix D Scenario Outline Form ES-D-1 Facility: Dresden Scenario No: ILT-R-3 Op-Test No: ILT 01-1 Retest Examiners: Operators:
Initial Conditions: 15% reactor power, IRM channel 15 OOS, Unit 3 is in Mode 1 Turnover: Unit startup in progress; synchronize the Main Generator to the grid, then continue power ascension.
Event Malfunction Event Event No. Number Type* Description 1NA N ANSO NA N SRO Synchronize Main Generator to the grid NSO 2NA R SO Raise reactor power by withdrawing control rods NSO RLMLFBF SRO A blown fuse causes a lockup of the LFRV ANSO A setpoint drift causes a spurious Isolation Condenser 4 ICSPDFT I SRO initiation NSO 5 FWICP1 C SRO High amps on the 2A condensate pump 6 Q21 C ANSO SRO Trip of the 2A Service water pump 7 HPRBBRKP ALL Unisolable steam leak in the reactor building from the RADFFD HPCI line with a fuel element failure M
8RDHYDKNSO 8 RDFHYDK SRO Rods fail to insert due to a hydraulic lock
- (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor