February 11, 2003 MEMORANDUM TO:
William F. Kane Deputy Executive Director for Reactor Programs FROM:
Edwin M. Hackett, Assistant Team Leader
/RA/
Davis-Besse Reactor Vessel Head Degradation Lesson Learned Task Force
SUBJECT:
MEETING
SUMMARY
- NOVEMBER 20, 2002, PUBLIC MEETING ON DAVIS-BESSE REACTOR VESSEL HEAD DEGRADATION LESSONS LEARNED TASK FORCE REPORT On November 20, 2002, members of the Davis-Besse Reactor Vessel Head Degradation Lessons Learned Task Force conducted a public meeting to discuss the findings and recommendations in its report ("Degradation of the Davis-Besse Nuclear Power Station Reactor Pressure Vessel Head Lessons-Learned Report," September 30, 2002). The meeting was held in the vicinity of the Davis-Besse site in Oak Harbor, Ohio. A list of meeting participants is Attached. The presentation used by the staff at the meeting is in the NRC electronic document handling system (ADAMS) at accession number ML030280481. The executive summary from the task force report was provided as a handout and is available in ADAMS at accession number ML030280448. The meeting transcript is available in ADAMS at accession number ML030280708. Written comments provided at the meeting by members of the public are in ADAMS at accession numbers ML030280465 and ML030360494.
Attachment:
As stated cc w/attachments:
W. Travers, EDO S. Collins, NRR J. Dyer, RGIII J. Grobe, RGIII
February 11, 2003 MEMORANDUM TO:
William F. Kane Deputy Executive Director for Reactor Programs FROM:
Edwin M. Hackett, Assistant Team Leader
/RA/
Davis-Besse Reactor Vessel Head Degradation Lesson Learned Task Force
SUBJECT:
MEETING
SUMMARY
- NOVEMBER 20, 2002, PUBLIC MEETING ON DAVIS-BESSE REACTOR VESSEL HEAD DEGRADATION LESSONS LEARNED TASK FORCE REPORT On November 20, 2002, members of the Davis-Besse Reactor Vessel Head Degradation Lessons Learned Task Force conducted a public meeting to discuss the findings and recommendations in its report ("Degradation of the Davis-Besse Nuclear Power Station Reactor Pressure Vessel Head Lessons-Learned Report," September 30, 2002). The meeting was held in the vicinity of the Davis-Besse site in Oak Harbor, Ohio. A list of meeting participants is Attached. The presentation used by the staff at the meeting is in the NRC electronic document handling system (ADAMS) at accession number ML030280481. The executive summary from the task force report was provided as a handout and is available in ADAMS at accession number ML030280448. The meeting transcript is available in ADAMS at accession number ML030280708. Written comments provided at the meeting by members of the public are in ADAMS at accession numbers ML030280465 and ML030360494.
Attachment:
As stated cc w/attachment:
W. Travers, EDO S. Collins, NRR J. Dyer, RGIII J. Grobe, RGIII Distribution:
ADAMS PUBLIC R. Borchardt, (NRR)
A. Howell (RIV)
E. Hackett (RES)
R. Haag (RII)
J. Donoghue (NRR)
R. Bywater (RIV)
P. Castleman (NMSS)
T. Koshy (NRR)
R. Lloyd (RES)
J. Starefos, (NRR)
S. Rosenberg (EDO)
ADAMS Accession Number: ML030560483 C:\\ORPCheckout\\FileNET\\ML030560483.wpd OFFICE NRR/DE RES/MEB NAME JDonoghue:dlc E. Hackett DATE 2/10/03 2/11/03 OFFICIAL RECORD COPY
ATTACHMENT U.S. NUCLEAR REGULATORY PUBLIC MEETING NOVEMBER 20, 2002 DAVIS-BESSE REACTOR VESSEL HEAD DEGRADATION LESSONS LEARNED NAME ORGANIZATION NAME ORGANIZATION Dan Salter HGP, Inc.
Bill Thomas CAC Craig Strumsky FirstEnergy Henry L. Hegrat FirstEnergy Amy Ryder Ohio Citizen Action Jere Witt Ottawa County Paul Gunter NIRS H. Whitcomb Resident Bob Zemenski DTE George Honma FirstEnergy Peter Jordan Scientech Steve Arndt Ottawa County Sonia Eischen Ohio EMA Rick Heltsen Ottawa County Jay Leininger Marathon Consulting Mike Drusbacky Ottawa County Jane Leininger Public Jim Greer Ottawa County EMA Tom Henry The Blade Peter Smith DTE Donna Lueke Michael Johnson FirstEnergy Doug Simpkins K. C. Prasad VSP Group, Inc.
Bob Pell FirstEnergy Dale Kremer FirstEnergy Richard Wilkins FirstEnergy Carl Koebel Ottawa Co. Commission Rick Young FirstEnergy Steve Frank MLB Barb Cabial Jennifer Funk News Herald Lew Myer First Energy John B. Fowler John Mangels The Plain Dealer Norm Peterson Detroit Edison T. Dusey Helen A. Spalding Resident Oscar Lewis Joelle Starefos NRC Region II Marlene Lewis Thomas Koshy NRC/NRR/RORP Dennis L. Fligor US Senator Voinovich Joseph Donoghue NRC/NRR/DLPM Valerie Barnes PSHA Stacey Rosenberg NRC/EDO Clark Price FirstEnergy R. William Borchardt NRC/NRR/ADIP Karen P. Scheffer NPR Cleveland Art Howell U.S. NRC Patrick McCloskey First Energy Bob Haag NRC Region II Ron Lloyd NRC/RES Ed Hackett NRC/RES Russ Bywater NRC Region II