Type B & C Test Results In response to your question, the following are the results of the most recent Type B and C tests performed at Beaver Valley Power Station Unit 1 and Unit 2:
BVPS Unit 1 Test Date 10/03/01 As-Found Leak Rate = 0.06 La (minimum pathway)
As-Left Leak Rate = 0.16 La (maximum pathway)
TS Acceptance Criteria = 0.60 La BVPS Unit 2 Test Date 2/24/02 As-Found Leak Rate = 0.07 La (minimum pathway)
As-Left Leak Rate = 0.13 La (maximum pathway)
TS Acceptance Criteria = 0.60 La ADAMS Accession Number: ML030510036 Mail Envelope Properties (3E540A7D.4A4 : 0 : 33956)