REACTIVITY CONTROL SYSTEMS MODERATOR TEMPERATURE COEFFICIENT (MTC)

LIMITING CONDITION FOR OPERATION 3.1.1.4 The moderator temperature coefficient (MTC) shall be:

a.

Less positive than +0.2 x 10-4 Ak/k/*F for power levels up to -70% of RATED THERMAL POWER, with a linear ramp to 0.0 x 10- Ak/k/ 0 F at 100% RATED THERMAL POWER as shown in Figure 3.1-1 and

b.

Less negative than -5.0 x

10-4 Ak/k/ 0 F at RATED THERMAL POWER.

APPLICABILITY:

MODES 1 and 2*#

ACTION:

With the moderator temperature coefficient outside any one of the above limits, be in HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.1.1.4.1 The MTC shall be determined to be within its limits by confirmatory measurements.

MTC measured values shall be extrapolated and/or compensated to permit direct comparison with the above limits.

4.1.1.4.2 The MTC shall be determined at the following frequencies and THERMAL POWER conditions during each fuel cycle:

a.

Prior to initial operation above 5% of RATED THERMAL POWER, after each fuel loading.

b.

At any THERMAL POWER, within 7 EFPD after reaching a RATED THERMAL POWER equilibrium boron concentration of 300 ppm.

  1. See Special Test Exception 3.10.4.

BEAVER VALLEY -

UNIT 1 3/4 1-5 Amendment No.-.2,51

0.9 0.8 S0.7 0.6 W 0.5 0

C.)

2 0.4

" 0.3 E

o 0.2 o 0.1 0 1_

1 I

I 0

10 20 30 40 50 60 70 80 90 100 RATED THERMAL POWER (percent)

Figure 3.1-1 Moderator Temperature Coefficient versus Power Level BEAVER VALLEY -

UNIT 1 3/4 1-5a Amendment No.- 251