Text
February 6, 2003 Mr. Mano Nazar Site Vice President Prairie Island Nuclear Generating Plant Nuclear Management Company, LLC 1717 Wakonade Drive East Welch, MN 55089
SUBJECT:
PRAIRIE ISLAND NUCLEAR GENERATING PLANT, UNITS 1 AND 2 -
OPPORTUNITY FOR COMMENT ON TASK INTERFACE AGREEMENT (TIA) 2003-01, "APPLICATION OF ASME CODE SECTION XI, IWB-2430 REQUIREMENTS ASSOCIATED WITH SCOPE OF VOLUMETRIC WELD EXPANSION AT THE PRAIRIE ISLAND NUCLEAR GENERATING PLANT" (TAC NOS. MB7294 AND MB7295)
Dear Mr. Nazar:
The Nuclear Regulatory Commissions (NRCs) Region III staff has requested technical assistance from the Office of Nuclear Reactor Regulation staff regarding the application of American Society of Mechanical Engineers, Code Section XI, IWB-2430, requirements associated with scope of volumetric weld expansion at the Prairie Island Nuclear Generating Plant, Units 1 and 2. The purpose of this letter is to provide you with the opportunity to respond to the enclosed Task Interface Agreement (TIA) 2003-01.
Our internal procedures encourage the input of licensees or other external stakeholders in order to ensure all relevant information has been considered in responding to a TIA. While you are not required to respond to this letter, your staff has previously indicated a desire to review and comment on the TIA.
If you decide to respond to this letter, we request that your response be provided within 60 days of the date of this letter. Please feel free to contact me at (301) 415-1446 if you have any questions.
Sincerely,
/RA/
John G. Lamb, Project Manager, Section 1 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-282 and 50-306
Enclosure:
TIA 2003-01 cc w/encl: See next page
Enclosure:
ML030170555 Package: ML030380404 OFFICE PDIII-1/PM PDIII-1/LA PDIII-1/SC NAME JLamb RBouling LRaghavan DATE 02/06/03 02/06/03 02/06/03
Prairie Island Nuclear Generating Plant, Units 1 and 2 cc:
J. E. Silberg, Esquire Shaw, Pittman, Potts and Trowbridge 2300 N Street, N. W.
Washington, DC 20037 Site Licensing Manager Prairie Island Nuclear Generating Plant Nuclear Management Company, LLC 1717 Wakonade Drive East Welch, MN 55089 Adonis A. Neblett Assistant Attorney General Office of the Attorney General 455 Minnesota Street Suite 900 St. Paul, MN 55101-2127 U.S. Nuclear Regulatory Commission Resident Inspectors Office 1719 Wakonade Drive East Welch, MN 55089-9642 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351 Administrator Goodhue County Courthouse Box 408 Red Wing, MN 55066-0408 Commissioner Minnesota Department of Commerce 121 Seventh Place East Suite 200 St. Paul, MN 55101-2145 Tribal Council Prairie Island Indian Community ATTN: Environmental Department 5636 Sturgeon Lake Road Welch, MN 55089 Mr. Roy A. Anderson Executive Vice President and Chief Nuclear Officer Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 Nuclear Asset Manager Xcel Energy, Inc.
414 Nicollet Mall Minneapolis, MN 55401 March 2002