VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGN*a 23261 January 28, 2003 United States Nuclear Regulatory Commission Serial No.03-050 Attention: Document Control Desk NLOS/ETS Washington, D.C. 20555 Docket No.
50-339 License No.
NPF-7 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT 2 ASME SECTION XI INSERVICE INSPECTION PROGRAM RELIEF REQUEST CMP-020 EXAMINATION OF REACTOR PRESSURE VESSEL HEAD-TO-FLANGE WELD During the Fall 2002 refueling outage, North Anna Power Station Unit 2 replaced the reactor pressure vessel head. The preservice examinations for the replacement head were conducted to the requirements of the 1995 Edition through 1996 Addenda of ASME Section Xl. However, interferences due to lifting lugs and the weld configuration prohibited complete examination of the reactor pressure vessel head-to-flange weld.
Pursuant to 10 CFR 50.55a(g)(5)(iii), relief is requested from certain requirements of ASME Section XI Code associated with the examination of the reactor pressure vessel head-to-flange weld where only partial coverage can be obtained.
Relief Request CMP-020 is attached and provides the basis of this request. A similar relief request was approved for FirstEnergy Nuclear Operating Company - Davis Besse Nuclear Power Station on December 17, 2002 (TAC MB5849).
This relief request has been approved by the Station Nuclear Safety and Operating Committee.
If you have any additional questions concerning this request, please contact us.
Very truly yours, Leslie N. Hartz Vice President - Nuclear Engineering Attachment Commitments made in this letter: None
cc:
U. S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, Georgia 30303 Mr. M. J. Morgan NRC Senior Resident Inspector North Anna Power Station Mr. M. M. Grace Authorized Nuclear Inspector North Anna Power Station Mr. J. E. Reasor, Jr.
Old Dominion Electric Cooperative Innsbrook Corporate Center 4201 Dominion Blvd.
Suite 300 Glen Allen, Virginia 23060
Attachment Relief Request CMP-020 Examination Of Reactor Pressure Vessel Head-To-Flange Weld Virginia Electric and Power Company North Anna Power Station Unit 2
Virginia Electric & Power Company North Anna Power Station Unit 2 Third 10 Year Interval Request for Relief Number CMP-020
- 1.
IDENTIFICATION OF COMPONENT Reactor pressure vessel head-to-flange weld (Weld 1, drawing 12050-WMKS-RC-R 1.2) for the replacement reactor vessel head.
I1.
CODE REQUIREMENTS ASME Section XI - 1995 Edition through 1996 Addenda, Table IWB-2500-1, examination category B-A, item number B1.40 requires volumetric and surface examinations, as defined by Figure IWB-2500-5, of essentially 100 percent of the weld length of the reactor pressure vessel closure head-to-flange weld. "Essentially 100 percent" as clarified by ASME Code Case N-460, Alternative Examination Coverage for Class 1 and Class 2 Welds, is greater than 90 percent coverage of the examination volume, or surface area, as applicable.
II. CODE REQUIREMENT FROM WHICH RELIEF IS REQUESTED In accordance with 10CFR50.55a(g)(5)(iii), relief is requested from the "essentially 100 percent" volumetric examination coverage requirement for the identified reactor pressure vessel head-to-flange weld. This requirement is considered impractical due to the configuration of the reactor pressure vessel head.
IV.
BASIS FOR RELIEF The ultrasonic examination of the reactor pressure vessel head-to-flange weld is conducted in accordance with Section XI, Appendix I of the ASME Code, 1995 Edition through the 1996 Addenda.Section XI, Appendix I states that the ultrasonic examination shall be conducted in accordance with Article 4 of Section V as supplemented by Table 1-2000-1. Article 4,Section V requires the weld and the adjacent base metal be examined using nominal angles of 45 and 60 degrees, (deviation is permitted if geometry limits the coverage, however, separation of angles must be 10 degrees) and a straight beam. Four basic scan directions are required for the angle beams; two perpendicular to the weld axis (axial scan) from opposite directions and two parallel to the weld axis (circumferential scan) from opposite directions. These requirements apply for each of the 45 and 60 degree angle beams used. Each of the 45 and 60 degree angle beams is required to pass through all of the weld volume in the four basic scan directions.
The cross-sectional geometry of the component at the reactor pressure vessel head to-flange weld produces a high transitional angle between the flange and the domed head. Scanning from the flange side may not provide the necessary angular orientation to provide full examination coverage. Examination is limited to 0.5 inch CMP-020 Page 1 of 8
from the weld toe due to the flange configuration. The reactor vessel closure head is a carbon steel vessel with stainless steel cladding on the inside surface. Due to this cladding, the ultrasonic beam cannot be "bounced" from the inside clad surface to increase the examination coverage. Therefore, a full-V examination from the flange side is not possible. Following operational service, radiographic examination of this weld will not be practical due to the projected high radiation levels at the inside surface of the head.
The reduction in pre-service volumetric coverage is detailed in Table CMP-20-1.
Figures CMP-20-1 through CMP-20-5 are provided detailing the configuration limitations experienced. The pre-service examination on the component listed above was completed to the extent practical as required by the Code.
Furthermore, three lifting lugs are located 120" apart. Each lug obstructs the volumetric examination for approximately 8 inches, resulting in obstruction of 2 of the 45 feet of total weld length. This limits access to approximately 4 percent of the weld length. However, these lifting lugs result in only a 0.8 percent obstruction during the magnetic particle examination resulting in a 99.2 percent surface examination.
The limited volumetric examination and the surface examination should detect any general patterns of degradation that may occur in the areas covered, therefore providing reasonable assurance of the continued structural integrity of the subject weld.
V.
ALTERNATE PROVISIONS One-third of the reactor pressure vessel head-to-flange weld will be examined each period to the extent permitted by the configuration of the reactor pressure vessel closure head as radiologically practical.
In addition, it is proposed that the pre-service examinations already completed at the reduced coverage be counted as meeting the Code requirements.
CMP-020 Page 2 of 8
Table CMP-020-1 North Anna Unit 2 Pre-Service Examination Coverage Summary Reactor Pressure Vessel Closure Head to Flange Weld Category B-A, Item Bi.40 Weld Metal = 11.3% of total exam volume (11.3% x 79.33%) = 9%
Base Metal = 88.7% of total exam volume (88.7% x 63.71%) = 57%
Total Exam Coverage Achieved = 9% + 57% = 66%
CMP-020 Page 3 of 8 Exam Sketch Sketch Weighting Coverage Coverage Factor 45" Weld Metal I CMP-20-1 55%
2 sound beams/9 12.22%
60" Weld Metal _-
CMP-20-2 52%
2 sound beams/9 11.56%
45* Weld Metal I CMP-20-3 100%
2 sound beams/9 22.22%
60° Weld Metal I CMP-20-3 100%
2 sound beams/9 22.22%
0* Weld Metal CMP-20-3 100%
1 sound beam/9 11.11%
Weld Total 79.33%
45/60" Base Metal -L CMP-20-4 88%
2 sound beams/7 25.14%
45° Base Metal CMP-20-5 54%
2 sound beams/7 15.43%
60° Base Metal CMP-20-5 54%
2 sound beams/7 15.43%
0* Base Metal CMP-20-5 54%
1 sound beam/7 7.71%
Base Total 63.71%
Figure CMP-020-1 North Anna Unit 2 Pre-Service Examination Coverage Summary Reactor Pressure Vessel Closure Head to Flange Weld Category B-A, Item B1.40 Component: RPV closure head to flange weld Coverage Sketch No: 1 of 5 Scale: 50%
Exam: Weld metal, 45o J EXAM AREA EFGH - 0,866 X 6.6 - 5.7 16 Iri DIRECTION 1
- Examined EFG14 = 100 %
DIRECTION 2
- Examined EFJK, (.886 X.7) + (.686 X.7)12 - 0.909 In"
(.909/5,716)=16%
C
.L ViA "iCoN I.
.L PIIKEcTIto 7.,
Ih VX A H S + 0 '
TOTAL a (100%+16%)12=58%
58% X (43'145) 5 5 %
CMP-020 Page 4 of 8
Figure CMP-020-2 North Anna Unit 2 Pre-Service Examination Coverage Summary Reactor Pressure Vessel Closure Head to Flange Weld Category B-A, Item B13.40 Component: RPV closure head to flange weod Coverage Sketch No: 2 of 5 Scale: 50%
Exam: Weld metal, 600 /
EXAM AREA EFGH - 0,866 X 6.6 a 5.716 Wr' DIRECTION I a
Examined EFGH a 100 %
DIRECTION 2 Examired EFJK - (.-866 X.3) 4 (.888 X,5)/2 m 0.476 in' (47 1 5.716), 8 %
- f.
off A
6 F
D
.J PitArC1IoN I.
J. PRLEc710W 2..
II EXAHS + 0' TOTAL (100%+8%)/2w64%
54%X(43145")-"2%
CMP-020 Page 5 of 8
Figure CMP-020-3 North Anna Unit 2 Pre-Service Examination Coverage Summary Reactor Pressure Vessel Closure Head to Flange Weld Category B-A, Item B1.40 Component: RPV closure head to flange weld Coverage Sketch No: 3 of 5 Scale: 60%
Exam: Weld metal. 45° 1 60' 1 and (r EXAM AREA
- EFGH 0.6W X 6.6 = 5.716 in' EXAMINED
- EFGH=100%
TOTAL 0-
-t00%
- 60" f -i00%
.L PlaftcTJoNJ I.
- 2. DIKEc7IO1t I.
II EXAMS + O" CMP-020 Page 6 of 8
Figure CMP-020-4 North Anna Unit 2 Pre-Service Examination Coverage Summary Reactor Pressure Vessel Closure Head to Flange Weld Category B-A, Item B1.40 Component: RPV closure head to flange weld Coverage Sketch No: 4 of 5 Scale. 50%
Exam: Base metal, 45 / 60 J
EXAM AREA AEHD + FBCG - (3.3 x 6.6) + (3.3 x 7) = 44.68 In' TWO SOUND BEAMS
- AEHD + FJLCG a = (3,3 x 6.6) + (.6 x.7) + (2.8 x S.4) = 40.4 in'
- (40.4144.88)=90%
ONE SOUND BEAM JKL=(4X 8)12-1.6 itn
- (1.6144.88)=4%
JI PJLEcr0lo I.
TOTAL
- 90%+2%-92%
- 92%x(43'145)w88%
CMP-020 Page 7 of 8 I rxAHS + 0' I. DIXEC1l09l 1.
Figure CMP-020-5 North Anna Unit 2 Pre-Service Examination Coverage Summary Reactor Pressure Vessel Closure Head to Flange Weld Category B-A, Item B1.40 A
Component: RPV closure head to flange weld Coverage Sketch No: 5 of 5 Scale: 50%
Exam: Base metal, 45° / 6W I5 and 0 EXAM AREA
, AEHD+FBCG=(33x6 6)+(3.3x7)=44.88in'.
EXAMINED D
"* AEHD + FJKG = (3.3 x 6,6) + (.5 x 7) = 25.28 in
"* (25.28144.8)=56 %
0 56%x(43'145'-5 4 %
TOTAL J-rIUM014 1.
1
-= 54%
S45' J -S4%
W o1 -s4%
DLrEc71oU T.
0 FxAHS +F 0 CMP-020 Page 8 of 8