ADMINISTRATIVE CONTROLS 6.12 HIGH RADIATION AREA As provided in paragraph 20'.1601(c) of 10 CFR Part 20, the following controls shall be applied to high radiation areas in place of the controls required by paragraph 20.1601(a) and (b) of 10 CFR Part 20:

6.12.1 High Radiation Areas with Dose Rates Not Exceeding 1.0 rem/hour at 30 Centimeters from the Radiation Source or from any Surface Penetrated by the Radiation

a.

Each entryway to such an area shall be barricaded and conspicuously posted as a high radiation area.

Such barricades may be opened as necessary to permit entry or exit of personnel or equipment.

b.

Access to, and activities in, each such area shall be controlled by means of Radiation Work Permit (RWP) or equivalent that includes specification of radiation dose rates in the immediate work area(s) and other appropriate radiation protection equipment and measures.

c.

Individuals qualified in radiation protection procedures and personnel continuously escorted by such individuals may be exempted from the requirement for an RWP or equivalent while performing their assigned duties provided that they are otherwise following plant radiation protection procedures for entry to, exit from, and work in such areas.

d.

Each individual or group entering such an area shall possess:

1.

A radiation monitoring device that continuously displays radiation dose rates in the area; or

2.

A radiation monitoring device that continuously integrates the radiation dose rates in the area and alarms when the device's dose alarm setpoint is reached, with an appropriate alarm setpoint, or

3.

A radiation monitoring device that continuously transmits dose rate and cumulative dose information to a remote receiver monitored by radiation protection personnel responsible for controlling personnel radiation exposure within the area, or

4.

A self-reading dosimeter (e.g., pocket ionization chamber or electronic dosimeter) and, (i)

Be under the surveillance, as specified in the RWP or equivalent, while in the area, of an individual qualified in radiation protection procedures, equipped with a radiation monitoring device that continuously displays radiation dose rates in the area; who is responsible for controlling personnel exposure within the area, or Amendment No. -142 HOPE CREEK 6-24

"(ii). Be. under the.surveillance as specified in the RWP or equivalent, while in the area, by means of S.closed circuit television, of personnel qualified in radiation protection procedures, responsible S.:

for controlling personnel radiation exposure in



-the area, and with the means to communicate with

. individuals in the area who are covered by such surveillance.

e.

Except for individuals qualified' in radiation protection procedures, or personnel continuously escorted by such individuals, entry into such areas shall be made only after dose rates in the-area have been determined and entry personnel are knowledgeable :of 'them.

"These continuously escorted personnel will-receive'a:-pre-job briefing prior 'to entry into such areas. -This doseirate'-determination, knowledge, and pre-job briefing does not require documentation prior to-initial-entry.

6.12.2 High Radiation Areas with Dose Rates'Gre&ter thari.0 rem/hour' at 30 Centimeters from the Radiation Source or-from -any Surface Penetrated by the Radiation, -but less th&n'500 rads/hbur at 1 Meterz from the Radiation Source or from any Surface Penetrated by the Radiation

a.

Each entryway to such an&aria ishall be"conspicuously -posted as a high radiation area'and shall -be'-provided with a locked or continuously guarded door -of gate that preventS unauthorized entry, and, -in; additýin: -

1.

All such door and 'gate '-keys `shali --be' maintained under the administrative control of the shift supervisor, radiation protection maager,' -orhis or her*. des ignee.

2.

Doors and gates shall remain locked except during periods of personnel or equipment entry-or exit. :

b.'

Access to, and activities in, each such area'shall be.'

controlled by means of an RWP '6r-iquivalent--ha ncludes

specification of radiation dose rates in the immediate work area(s) and other appropriate ra'diatio'n, protection.equipmeAt' and measures.

c.

Individuals qualified in radiato6n-protecti6h procedures inay be exempted from the requirements for-an RWP '6 equivalent while performing radiation surveys in such areas provided that they are otherwise -following 1ant-r.adiatio'nprotection procedures for entry to, exiEI'fr-on*, arid-work-in-'-such ýareas.:

d.

Each individual or group entering.such an -area shall possess:

1.

A radiation monitoring devic4-that continuously integrates the radiation dose -rates-in the area and alarms when the device's dose- -larm -setpo6ini is reached, with an appropriate --alarm setP-oint, ror' Amendment No. 142 6-24a HOPE CREEK

2.

A radiation monitoring device that continuously transmits dose rate and cumulative-dose information to a remote receiver monitored by radiation protection personnel responsible for controlling personnel radiation exposure within the area with the means to communicate with and control every individual in the area, or

3.

A self-reading dosimeter (e.g., pocket ionization chamber or electronic dosimeter) and,'

(i)

Be under the surveillance, as'specifiedin the RWP or equivalent,-while in :the area, of an-,

individual qualified in-radiation protection procedures, equipped witheairadiation monitoring device that continuously displays radiation-dose.

rates in the area;- whoris responsible-for!

controlling personnel:exposure within the-area,-.

or (ii)

Be under: the: surveillance as'specified in the RWP or equivalent,. while= in-the area, by means of closed circuit -television, of personnel qualified in radiation.-protection procedures, responsible for controlling personnel radiation exposure in the area.,. and with -themeans to communicate with and control every individual in the area.

4.

In those cases wherecoptions 42) and (3),, above; are impractical or determined to be inconsistent with the "As Low As is Reasonably Achievable* -principle,. a I

radiation monitoring device.-that Icontinuously-displays radiation dose rates in the area. -

e.

Except for individuals qualified in -radiation-protection procedures, or personnel continuously escorted by ýsuch.

individuals, entry into such areas shall be made only after dose rates in the area have-.been %determined and entry.

personnel are knowledgeable :-of -thexn7.

.-These -continuously -

escorted personnel will receive -ia pre-.job briefing, prior to entry into such areas.

This dose*,rate -determination; knowledge, and pre-job briefing does-not require documentation prior to initial entry.

f.

Such individual areas that =are within *a::larger area where no" -

enclosure exists for the purpose *of-l-ocking and -where no enclosure can reasonably be-constructed-around the-individual area need not be controlled by.-a-iocked doorlor-.-gate, ýnor -.

continuously guarded, but shall be barricaded, conspicuously posted, and a clearly visible flash-ingz.light shall be-activated at the area as a warning device.

H C4Amendment:N6. 142 6-24b I._