ML030280124

From kanterella
Jump to navigation Jump to search

RAI, Reactivity Control Systems, Power Distribution Limits, & Special Test Exceptions
ML030280124
Person / Time
Site: Millstone 
Issue date: 01/28/2003
From: Richard Ennis
NRC/NRR/DLPM/LPD1
To: Douglas Dodson, Price J
Dominion Nuclear Connecticut
Ennis R, NRR/DLPM, 415-1420
References
TAC MB6108
Download: ML030280124 (6)


Text

January 28, 2003 Mr. J. A. Price Site Vice President - Millstone Dominion Nuclear Connecticut, Inc.

c/o Mr. David W. Dodson Rope Ferry Road Waterford, CT 06385

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - REACTIVITY CONTROL SYSTEMS, POWER DISTRIBUTION LIMITS, AND SPECIAL TEST EXCEPTIONS, MILLSTONE POWER STATION, UNIT NO. 2 (TAC NO. MB6108)

Dear Mr. Price:

By letter dated August 14, 2002, you submitted a proposed amendment to the Technical Specifications (TSs) for Millstone Power Station, Unit No. 2. The proposed amendment would revise the TSs related to reactivity control systems, power distribution limits, and special test exceptions.

The U.S. Nuclear Regulatory Commission staff is reviewing your submittal and has determined that additional information is required to complete the review. The specific information requested is addressed in the enclosure. We request that the additional information be provided by February 28, 2003. The response time frame was discussed with Mr. Ravi Joshi of your staff on January 23, 2003. If circumstances result in the need to revise your response date, or if you have any questions, please contact me at (301) 415-1420.

Sincerely,

/RA/

Richard B. Ennis, Senior Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-336

Enclosure:

Request for Additional Information cc w/encl: See next page

ML030280124

  • See previous concurrence OFFICE PDI-2/PM PDI-2/LA (A)

SRXB/SC*

PDI-2/SC NAME REnnis LCox FAkstulewicz VNerses for JClifford DATE 1/24/03 1/24/03 1/10/03 1/27/03

Millstone Power Station Unit 2 cc:

Ms. L. M. Cuoco Senior Counsel Dominion Nuclear Connecticut, Inc.

Rope Ferry Road Waterford, CT 06385 Edward L. Wilds, Jr., Ph.D.

Director, Division of Radiation Department of Environmental Protection 79 Elm Street Hartford, CT 06106-5127 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 First Selectmen Town of Waterford 15 Rope Ferry Road Waterford, CT 06385 Charles Brinkman, Manager Washington Nuclear Operations ABB Combustion Engineering 12300 Twinbrook Pkwy, Suite 330 Rockville, MD 20852 Senior Resident Inspector Millstone Power Station c/o U.S. Nuclear Regulatory Commission P.O. Box 513 Niantic, CT 06357 Mr. W. R. Matthews Senior Vice President - Nuclear Operations Dominion Nuclear Connecticut, Inc.

Rope Ferry Road Waterford, CT 06385 Mr. P. J. Parulis Manager - Nuclear Oversight Dominion Nuclear Connecticut, Inc.

Rope Ferry Road Waterford, CT 06385 Mr. D. A. Christian Senior Vice President - Nuclear Operations and Chief Nuclear Officer Innsbrook Technical Center - 2SW 5000 Dominion Boulevard Glen Allen, VA 23060 Mr. John Markowicz Co-Chair Nuclear Energy Advisory Council 9 Susan Terrace Waterford, CT 06385 Mr. Evan W. Woollacott Co-Chair Nuclear Energy Advisory Council 128 Terrys Plain Road Simsbury, CT 06070 Mr. D. A. Smith Manager - Licensing Dominion Nuclear Connecticut, Inc.

Rope Ferry Road Waterford, CT 06385 Ms. Nancy Burton 147 Cross Highway Redding Ridge, CT 00870 Mr. G. D. Hicks Director - Nuclear Station Safety and Licensing Dominion Nuclear Connecticut, Inc.

Rope Ferry Road Waterford, CT 06385 Mr. S. E. Scace Assistant to the Site Vice President Dominion Nuclear Connecticut, Inc.

Rope Ferry Road Waterford, CT 06385

Millstone Power Station Unit 2 cc:

Mr. A. J. Jordan, Jr.

Director - Nuclear Engineering Dominion Nuclear Connecticut, Inc.

Rope Ferry Road Waterford, CT 06385 Mr. S. P. Sarver Director - Nuclear Station Operations and Maintenance Dominion Nuclear Connecticut, Inc.

Rope Ferry Road Waterford, CT 06385

Enclosure REQUEST FOR ADDITIONAL INFORMATION REGARDING PROPOSED AMENDMENT TO TECHNICAL SPECIFICATIONS REACTIVITY CONTROL SYSTEMS, POWER DISTRIBUTION LIMITS, AND SPECIAL TEST EXCEPTIONS MILLSTONE POWER STATION, UNIT NO. 2 DOCKET NO 50-336 By letter dated August 14, 2002, Dominion Nuclear Connecticut, Inc. (the licensee) submitted a proposed amendment to the Technical Specifications (TSs) for Millstone Power Station, Unit No. 2 (MP2). The proposed amendment would revise the TSs related to reactivity control systems, power distribution limits, and special test exceptions.

The Nuclear Regulatory Commission (NRC) staff has reviewed the information the licensee provided that supports the proposed TS changes. In order for the staff to complete its evaluation, the following additional information is requested:

1. The factors to be considered in the Shutdown Margin (SDM) determination as currently specified in Surveillance Requirement (SR) 4.1.1.1.1.d is proposed for deletion and the wording relocated to the corresponding TS Bases section. Provide justification for this change.
2. In Attachment 1, Page 3 of your submittal, you state that Conditions D and Required Action D.1 in the proposed revision to TS 3/4.1.3.1 covers the deletion of current SR 4.1.1.1.1.a. However, SR 4.1.1.1.1.a applies when rods are immovable or untrippable, and proposed TS 3/4.1.3.1, Condition D, only applies when the rods are untrippable. What is the difference between immovable and untrippable? How do you account for immovable rods? Furthermore, your current SR 4.1.1.1.1.a requires that you increase SDM by an amount equal to the withdrawn worth of the inoperable rod, but your proposed TSs do not contain this requirement. Provide justification for this change.
3. For proposed SR 4.1.1.2, Note 2, you state that the SR will only be required after 60 Effective Full Power Days. However, your current SR 4.1.1.1.2 does not allow for this 60-day period. Provide justification for this change.
4. It is our understanding that you perform SR 4.1.1.1.1.c to confirm that you meet the Core Operating Limits Report requirements for SDM when you are at your Transient Insertion Limits. Attachment 1, Page 3 of your submittal states that deleting this requirement is acceptable because the SDM is met when the control element assemblies (CEAs) are within or at the insertion limits specified by TSs 3/4.1.3.5 and 3/4.1.3.6. Provide further justification for removal of this requirement, given that it appears its intent is to verify your Transient Insertion Limits. Furthermore, provide justification given that other factors affect SDM, including boron concentration, fuel burnup, xenon, samarium, etc.
5. Your current Limiting Condition for Operation (LCO) 3.1.3.1 states that each CEA shall be within 10 steps of all other CEAs in its group. Your proposed LCO 3.1.3.1 states that each CEA shall be within 10 steps of its group. Provide justification for this change.
6. The proposed TS 3/4.1.3.1 Action B allows you to have six more hours until you are in Mode 3 than your current TS 3/4.1.3.1 Action b. Provide justification for this change.

Furthermore, justify why 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> to achieve Mode 3 is acceptable for all the action statements of TS 3/4.1.3.1.

7. Current LCO 3.1.3.6, Action c.2, requires the plant to be in HOT STANDBY (i.e., Mode 3) within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. Proposed LCO 3.1.3.6, Action C.1, would extend the time to achieve Mode 3 from 4 to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. Attachment 1, Page 27 of your submittal states that this is consistent with TS 3.0.3. Provide justification for this change from a safety standpoint.
8. Current LCO 3.2.4 Action b allows plant operation for up to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> with the AZIMUTHAL POWER TILT (Tq ) > 0.10, provided that the TOTAL UNRODDED INTEGRATED RADIAL PEAKING FACTOR (FT r) is within the limits of TS 3.2.3. However, your proposed changes (Action b.1) allow you to operate for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in this condition prior to checking FT
r., Page 28 of your submittal states that 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> is sufficient time for the operator to evaluate that this factor is within limit. Provide justification for this change from a safety standpoint.
9. When performing SDM calculations, how do you account for Doppler Reactivity? Consider addressing this consideration in TS Bases 3/4.1.1.1.