ML030230283

From kanterella
Jump to navigation Jump to search
December 2002 Monthly Operating Report for Calvert Cliffs Nuclear Power Plant
ML030230283
Person / Time
Site: Calvert Cliffs  Constellation icon.png
Issue date: 01/16/2003
From:
Constellation Energy Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML030230283 (7)


Text

Kevin J. Nietmann 1650 Calvert Cliffs Parkway Lusby, Maryland 20657 Plant General Manager 410 495-4101 Calvert Cliffs Nuclear Power Plant 410 495-4787 Fax Constellation Generation Group, LLC Energy Group Constellation January 16, 2003 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION: Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit Nos. 1 & 2; Docket Nos. 50-317 & 50-318 December 2002 Operating Data Reports The subject reports are being sent to you as required by Technical Specification 5.6.4.

Should you have questions, please contact Mr. Thomas S. O'Meara at (410) 495-6940.

Very truly yours, KJN/PSF/bjd Attachments cc: J. Petro, Esquire Resident Inspector, NRC J. E. Silberg, Esquire R. I. McLean, DNR Director, Project Directorate I-1, NRC J. Wright, INPO D. M. Skay, NRC K. N. Larson, ANI H. J. Miller, NRC

OPERATING DATA REPORT Docket No. 50-317 Calvert Cliffs Unit 1 January 3, 2003 Prepared by Herman 0. Olsen Telephone:(410)495-6734 REPORTING PERIOD DECEMBER 2002 DESIGN ELECTRICAL RATING (NET MWe) 845 MAXIMUM DEPENDABLE CAP'Y (NET MWe) 825 Year Cumulative This month to-Date to Date

1. NUMBER OF HOURS REACTOR WAS CRITICAL 744.0 5,557.3 183,289.4
2. HOURS GENERATOR ON LINE 744.0 5,510.0 180,125.7
3. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
4. NET ELECTRICAL ENERGY GENERATED(MWH) 647,331 4,645,180 147,167,263

UNIT SHUTDOWNS DOCKET NO. 50-317 UNIT NAME Calvert Cliffs - Ul DATE January 3, 2003 COMPLETED BY Herman 0. Olsen TELEPHONE (410) 495-6734 REPORTING MONTH December 2002 NO.

DATE TYPE DURATION REASON' METHOD OF CAUSE/CORRECTIVE ACTIONS F: FORCED (HOURS) SHUTTING S: SCHEDULED DOWN 2 COMMENTS There were no shutdowns this month.

' Reason: 2 Method:

A - Equipment Failure I - Manual B - Maintenance or Test 2 - Manual Scram.

C - Refueling 3 - Automatic Scram.

D - Regulatory Restriction 4 - Continued E - Operator Training & License Examination 5 - Other F - Administrative G - Operational Error H - Other

DOCKET NO. 50-317 CALVERT CLIFFS - UNIT 1 January 3, 2003

SUMMARY

OF OPERATING EXPERIENCE December 2002 The unit operated at 100% power for the entire month.

OPERATING DATA REPORT Docket No. 50-318 Calvert Cliffs Unit 2 January 3, 2003 Prepared by Herman 0. Olsen Telephone:(410)495-6734 REPORTING PERIOD DECEMBER 2002 DESIGN ELECTRICAL RATING (NET MWe) 845 MAXIMUM DEPENDABLE CAP'Y (NET MWe) 835 Year- Cumulative This month to-Date to Date

1. NUMBER OF HOURS REACTOR WAS CRITICAL 744.0 8,760.0 177,559.8
2. HOURS GENERATOR ON LINE 744.0 8,760.0 175,704.7
3. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
4. NET ELECTRICAL ENERGY GENERATED(MWH) 644,988 7,480,552 144,586,430

UNIT SHUTDOWNS DOCKET NO. 50-318 UNIT NAME Calvert Cliffs-U2 DATE January 3, 2003 COMPLETED BY Herman 0. Olsen TELEPHONE (410) 495-6734 REPORT MONTH December 2002 NO. DATE TYPE DURATION REASON' METHOD OF CAUSE/CORRECTIVE ACTIONS F: FORCED (HOURS) SHUTTING S: SCHEDULED DOWN 2 COMMENTS There were no shutdowns this month.

' Reason: 2 Method:

A - Equipment Failure I - Manual B - Maintenance or Test 2 - Manual Scram.

C - Refueling 3 - Automatic Scram.

D - Regulatory Restriction 4 - Continued E - Operator Training & License Examination 5 - Other F - Administrative G - Operational Error H - Other

DOCKET NO. 50-318 CALVERT CLIFFS - UNIT 2 January 3, 2003

SUMMARY

OF OPERATING EXPERIENCE December 2002 The unit operated at 100% reactor power for the entire month.