ES-401 Written Examination Form ES-401-9 Review Worksheet
- 1.
- 2.
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
- 7.
Q#
LOK LOD I
I I
II_
(F/H)
(1-5)
Stem Cues T/ýFTCred. IPartial Job-Minutia #/I Back-Q* A R
U/EIS Explanation
[tFocus J
j IDist.
Link units ward K/A Only 1
H 3
S 2
F 2
E Distractor C is phrased differently. Distractor C revised.
3 F
2 S
4 F
2 E
Add to stem "during normal operating conditions" Stem revised.
5 H
3 E
Periods for distractors. Licensee will ensure consistency.
6 H
3 S
7 H
3 S
8 F
2 X
U K/A mismatch. Re-written with same KIA.
9 H
2 S
10 F
2 S
nstructions
[Refer to Section D of ES-401 and Appendix B for additional information regarding each of the following concepts.]
- 1.
Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.
- 2.
Enter the level of difficulty (LOD) of each question using a 1 - 5 (easy - difficult) rating scale (questions in the 2 - 4 range are acceptable).
- 3.
Check the appropriate box if a psychometric flaw is identified:
The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information).
The stem or distractors contain cues (i.e., clues, specific determiners, phrasing, length, etc).
The answer choices are a collection of unrelated true/false statements.
More than one distractor is not credible.
One or more distractors is (are) partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by stem).
- 4.
Check the appropriate box if a job content error is identified:
The question is not linked to the job requirements (i.e., the question has a valid K/A but, as written, is not operational in content).
The question requires the recall of knowledge that is too specific for the closed reference test mode (i.e., it is not required to be known from memory).
The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).
The question requires reverse logic or application compared to the job requirements.
- 5.
Check the appropriate box if the sampled question does not match the approved K/A or an SRO-only question is not at the SRO level.
- 6.
Based on the reviewer's judgment, is the question as written (U)nacceptable (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?
- 7.
For any "U" ratings, at a minimum, explain how the Appendix B psychometric attributes are not being met.
NUREG-1021, Revision 8, Supplement I 44 of 46
ES-401 2
Form ES-401-9
- 1.
- 2.
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
- 7.
Q#
LOK LOD II I
I I
I (F/H)
(1-5)
Stem Cues T/FlCred. Partial Job-Minutia
- /
Back-Qt SRO U/E/S Explanation FocusI __
___J IDist.
Link units ward K/A Only Focu Lin I
I_
I 11 F
2 X
U MFP discharge valves not full open would not cause pp trip. Revised.
12 F
2 S
13 F
2 S
14 H
3 S
15 H
3 S
16 F
2 S
17 F
2 S
18 H
3 S
19 F
2 S
20 F
2 X
U K/A mismatch, periods. Question okay after explanation.
21 H
3 E
Bus 2-3 on same line. Revised.
22 F
2 X
U Two distractors not plausible. Distractors A and B revised.
23 F
2 E
Periods. Okay.
24 H
3 S
25 H
2 E
"A" is possibly correct. Question replaced by licensee.
26 H
3 S
27 F
2 X
U A & C implausible. Question revised.
28 F
2 E
Periods. Okay.
29R F
3 S
29S H
3 S
30 H
3 S
NUREG-1021, Revision 8, Supplement 1 45 of 46
ES-401 2
Form ES-401-9
- 1.
- 2.
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
- 7.
Q#
LOK LOD (FIH)
(1-5)
Stem jCues T/F Cred. Partial Job-Minutia
- /
Back-Q I SRO UIEIS Explanation
___Focusl j
1_ Dist.
I Link I__
I units Iward KIA Only___
31 H
3 S
32 F
2 S
33 F
2 S
34 F
1 U
LOD 1. Question replaced.
35 H
2 S
36 F
2 S
37 H
2 S
38 F
2 E
Switch order of B & C. Order switched.
39 F
2 E
Are C & D modes or positions? Question revised.
40 F
2 S
New question for RO.
41 H
2 E
Space in stem. Space provided.
42 H
2 E
"Trip" RCP in "A." Revised.
43 H
3 S
44 H
3 S
45 F
2 E
Periods. Okay.
46 F
2 E
"A" only answer that doesn't start with "reduces." No mention of LOOP in stem, so "C" may be correct. Why Higher Cog? Revised.
47 H
3 X
U "A" & "C" implausible since MSIVs outside CAN.
Revised A &C.
48 H
3 E
Add word. Revised.
49 H
3 X
U C & D implausible. Question replaced.
50 H
3 E
Change wording of stem. Revised.
NUREG-1021, Revision 8, Supplement 1 45 of 46
ES-401 2
Form ES-401-9
- 1.
- 2.
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
- 7.
Q#
LOK LOD (F/H)
(1-5)
Stem Cues T/F Cred. Partial Job-Minutia
- /
Back-Q.
SRO U/E/S Explanation Focus D st.
J Link
[units ward K/A Only; 51 F
2 S
52 F
2 S
53 H
3 S
54 F
1 U
LOD 1. Question replaced.
55 F
2 S
56 F
2 S
57 H
3 S
58 H
3 S
59 H
3 S
60 F
2 S
61 H
3 S
62 H
3 S
63 H
3 S
Question replaced due to no Mid-loop ops at BV2.
64 H
3 S
65 H
2 S
66 H
3 S
67 F
2 S
68 H
3 S
69 H
3 S
70 H
3 E
Change word in distractor "A." Revised.
NUREG-1021, Revision 8, Supplement 1 45 of 46
ES-401 2
Form ES-401-9
- 1.
- 2.
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
- 7.
Q#
LOK LOD T I I
I (F/H)
(1-5)
Stem Cues TIF Cred. Partial Job-Minutia
- /
Back-Q SRO U/E/S Explanation Focus jDist.
Link Iunits ward K/A Only 71R H
3 S
71S H
3 S
72 H
3 S
73 H
3 S
74 F
2 S
75R H
3 S
75S F
2 S
76R F
2 S
76S H
2 S
77R F
2 S
77S H
3 E
Periods. Okay.
78R F
3 S
78S H
2 S
79R F
2 E
Insert "emergency" for equipment. Revision not necessary.
79S H
3 S
80R H
2 S
80S H
3 S
81R H
2 S
81S H
3 E
Remove word "both" in B & C. Question replaced.
82R H
2 S
82S H
3 E
Periods, abbreviation. Okay.
83R H
2 S
83S H
2 X
U Distractors C&D implausible. Question revised, added reference.
84R F
2 S
- 1.
- 2.
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
- 7.
Q#
LOK LOD (F/H)
(1-5)
Stem Cues T/F Cred. Partial Job-Minutia
- /
Back-Q SRO U/E/S Explanation Focus I
I Dist.
I Link unitsI ward K/A Only 84S F
2 X
X U
K/A mismatch. Distractors A&B implausible, release must stop with effluent alarm. Revised.
85R F
2 E
Periods. Okay.
85S F
2 X
U K/A mismatch. Revised.
86R F
2 S
86S H
3 X
U K/A mismatch. Revised.
87R H
3 S
87S F
2 S
88R H
3 X
U K/A mismatch. Revised.
88S F
2 S
89R F
2 S
89S F
2 S
90R H
3 S
F90S2 I
I I
I I
I I
2_ 1 E
/A not specified. Added text.
NUREG-1021, Revision 8, Supplement 1 45 of 46
ES-401 2
Form ES-401-9
- 1.
- 2.
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
- 7.
Q#
LOK LOD (F/H)
(1-5)
Stem CuesT/F ICred. Partial Job-Minutia
- /
Back-Q' 1SRO U/E/S Explanation Focus I
Dist I Link units ward K/A I Only 1 1
91R H
3 E
K/A wrong. K/A text corrected.
91S F
2 E
Periods, K/A not specified. K/A text added.
92R F
2 S
92S F
2 S
93R H
2 E
Typo in first bullet. Corrected.
)3S F
2 S
94R F
2 S
94S F
2 S
95R F
2 S
95S H
2 E
Periods. Okay.
96R F
2 E
Answer "c" may not be correct based on explanation. Answer C okay.
96S F
2 E
"RO" in parentheses. Corrected.
97R F
2 E
Change word in distractor"C." Revised.
97S H
2 S
98R H
3 S
98S H
3 X
U A & D identical distractors. Revised.
99R H
3 S
99S H
2 X
U Distractors A & B not credible. Revised A & B.
1O0R H
2 S
100S H
3 E
Numerous. Corrected.
101 102 NUREG-1021, Revision 8, Supplement 1 45 of 46