Entergy Operations, Inc.

Russellville, AR 72802 Tel 501858 5000 1CAN010301 January 17, 2003 U. S. Nuclear Regulatory Commission Document Control Desk Mail Station OP1-17 Washington, DC 20555

Subject, Arkansas Nuclear One - Unit 1 Docket No. 50-313 License No. DPR-51 Once Through Steam Generator Inservice Inspection Report

Dear Sir or Madam:

Arkansas Nuclear One, Unit 1 (ANO-1), Technical Specification 5.6.7.a requires the complete results of each inservice inspection of the once through steam generator (OTSG) tubes to be submitted to the NRC within 90 days of the completion of the inspection.

Attached is the Steam Generator Tubing Inservice Inspection Report for the ANO-1 seventeenth refueling outage (1R17).

The OTSG tube inspections were completed on October 19, 2002.

Additionally, in correspondence dated February 19, 2001 (1CAN020104),

Entergy committed to provide a determination of the best-estimate total leakage that would result from an analysis of the limiting Large Break Loss of Coolant Accident (LBLOCA).

The analysis is to be based on circumferential cracking in the original tube-to-tubesheet rolls, tube-to-tubesheet reroll repairs, and heat affected zones of seal welds as found during each inspection. Accordingly, the calculated maximum total best-estimate LBLOCA leakage was determined to be 1.87 gpm.

Should you have any questions, please contact me.

This submittal contains no commitments.

Very truly yours, Sherrie R. Cotton Director, Nuclear Safety Assurance SRC/fpv Attachment

1CAN010301 Page 2 cc:

Mr. Ellis W. Merschoff Regional Administrator U. S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 NRC Senior Resident Inspector Arkansas Nuclear One P.O. Box 310 London, AR 72847 Mr. William Reckley NRR Project Manager Region IV/ANO-1 U. S. Nuclear Regulatory Commission NRR Mail Stop 0-7 D1 One White Flint North 11555 Rockville Pike Rockville, MD 20852

1R17 ONCE THROUGH STEAM GENERATOR INSERVICE INSPECTION 90 DAY REPORT The Arkansas Nuclear One, Unit 1 (ANO-1) 1R17 eddy current inspection of the once through steam generators (OTSGs) consisted of performing over 63,000 eddy current exams. Technical Specification 5.6.7.a requires that a 90 day report be submitted to the NRC. The following are to be included in the report:

a.

Number and extent of tubes inspected;

b.

Location and percent of wall-thickness penetration for each indication of an imperfection;

c.

Identification of tubes plugged and tubes sleeved;

d.

Number of tubes repaired by rerolling and number of indications detected in the new roll area of the repaired tubes;

e.

Summary of the condition monitoring and operational assessment results when applying tube end cracking (TEC) alternate repair criteria; and

f.

Summary of the condition monitoring and the operational assessment results (including growth) when applying the upper tubesheet ODIGA alternate repair criteria.

1.0 ANO-1 Steam Generator Description Arkansas Nuclear One, Unit-i utilizes a Once Through Steam Generator (OTSG) design for primary to secondary heat transfer. The OTSGs were manufactured by Babcock and Wilcox (Model FA-177).

Each OTSG contains 15,531 straight tubes constructed of thermally treated (sensitized) Inconel alloy 600 (1-600) material with an outside diameter of 5/8 inches and a nominal wall thickness of 0.037 inches. The tubes are hard rolled to a depth of approximately one and one half inches in the upper and lower tubesheets. There exists 15 broached tube support plates (TSP) ranging between 36 and 48 inches apart vertically along the OTSG. Figure 1.1 shows an OTSG.

The temperature of the reactor coolant entering the hot leg is 6020 F and the cold leg exit temperature is 5570 F. The thermal hydraulic design of the OTSGs allows a phase change to occur on the secondary side between the 6h and 9h TSP. Superheating of 40-50 degrees occurs through the remaining portion of the OTSG.

1

Figure 1.1 REACTO COOLANT INLET

"" MANWAT s-HANOI4U ECOWATER INLET TUBE SUPPORT PLATE

ý- ADOJUSTABLE IRtICI UNIT I STEAM GENERATOR ARRANGEMENT Inspection Scope and Results Table 1.1 provides a listing of the inspections performed and the extent of the test:

2

Table 1.1 1R17 Inspection Scope I............A rea ::.....

      • iO T S G iiiliiiii: E* xa~m s *l * ':!f?:

-.:i:i 100% Bobbin Full Length of Tube A

14,612 B

15,176 100% RPC/+-point Upper Rolls A

12,074

______________B 13,452 100% RPC/+-point Re-rolls A

2,108

______________B 1,244 Sleeve +-point Expansion Area (3 joints)

A 167 (100% 1-600, 20% 1-690)

B 152 Sleeve Bobbin Freespan A

430 B

480 Dent RPC/+-point Super Heat Dents (20%)

A 122 B

62 Lower Tubesheet +-point A

617 B

290 Other Special Interest IGA and Diagnostic A

758 B

546 Post Re-roll Bobbin A

187

______________B 154 Post Re-roll Plus Point A

187 B

154 2.0 Report

a.

Number and extent of tubes inspected Table 2.1 lists confirmed degradation. Detailed inspection results are provided in Reference 3.

3

Table 2.1 1R17 Inspection Results XDamage Mech~a~nis iSpe*

Ae*TSpe' i)

OTSG Numb'er ietectec Tube End Cracking in the HAZ Axial (SAA/MAA)

A 1,383 B

797 Circ (SCI/MCI)

A 39 B

8 Previously Repaired A

163 (OPB)

B 19 Upper Roll / Transition Cracking A

40 B

41 Re-roll Cracking Upper Transition (OPB)

A 1,457 B

1,094 Lower Transition "toe" A

0 Axial B

10 Lower Transition (Vol.)

A 11 B

1 Other Re-roll Indications A

14 Within the Press Bound.

B 3

Volumetric IGA Indications in the UTS A

335 B

226 Sleeve Flaws A

0 B

0 Indications in Dents A

0 B

0 Lower Tubesheet / Sludge pile Above TS Face A

0 Volumetric B

1 Mechanical Wear New A

141 B

120 Previous A

296 B

328 Upper Tubesheet Axial Flaws Secondary Face of UTS A

7 B

1 Freespan/Bundle Flaws Axial A

47 B

7 Volumetric A

2 B

2 OPB - Outside Pressure Boundary

b.

Location and percent of wall-thickness penetration imperfection; for each indication of an The only qualified technique for sizing indications that are allowed to remain in service at ANO-1 is associated with wear. Other indications are repaired or allowed to remain in service based on alternate repair criteria. The wear indications are found in Tables 4 and 5.

Tables 6 and 7 provide those indications that are addressed by the upper tube sheet ODIGA ARC and Tables 8 and 9 lists those indications that are addressed by the TEC ARC.

4

c.

Identification of tubes plugged and tubes sleeved; Tables 10 - 13 are attached with a listing of tubes that were plugged and those that were rerolled. No sleeves were installed during 1R17. The number of installed plugs were:

SGA SGB 76 43 Table 2.2 provides a summary of the tubes repaired by plugging or sleeving since the pre service inspection-Table 2.2 PRESERV Dec-74 0

2 0

1 Jan-77 500 1.37 0

0 0

2 Feb-78 770 2.11 5

0 5

3 Mar-79 1060 2.90 0

0 5

IIAA Jul-80 3

0 8

1AB Sep-80 1

0 9

4 Jan-81 1389 3.81 7

0 16 IL5 May-82 10 0

26 5

Nov-82 1835 503 84 48 110 1L6 Jul-83 43 0

153 IM6 Mar-84 43 37 196 6

Oct-84 2234 6.12 24 7

220 7

Sep-86 2678 7.34 1

4 221 1 L8 Jan-87 1

0 222 8

Aug-88 3116 8.54 13 0

235 1F89-1 Feb-89 0

0 235 9

Oct-90 3511 962 0

9 235 10 Feb-92 3895 1067 235 71 470 11 Sep-93 4371 11.98 22 12 492 12 Feb-95 4826 13.22 7

3 499 13 Sep-96 5334 1461 68 48 567 14 Mar-98 5832 15.98 66 30 633 15 Sep-99 6333 17.35 213 63 846 16 Mar-01 6855 18.80 73 21 919 17 Oct-02 7384 200 76 43 994 2

2 2

2 2

2 2

2 50 50 87 94 98 98 98 98 107 178 190 193 241 271 334 355 398 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

54 54 54 54 54 54 54 53 0

0 0

0 0

0 0

0 0

0 0

10 50 50 148 148 176 351 427 427 422 421 414 376 374 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

123 123 122 121 121 121 121 121 0

0 0

0 0

0 0

0 0

0 0

0 0

0 76 0

147 366 366 366 363 363 1963 363 78 359 232 358 187 1155 33 94 154 0

0 5

5 8

9 16 26 110 153 196 222 229 230 258 258 263 531 565 572 639 705 917 984 1059 2

000% 0.01%

2 000% 0.01%

2 0.03% 001%

2 003% 001%

2 0.05% 001%

2 006% 001%

2 010% 001%

2 017% 001%

50 071% 032%

50 0 99% 0.32%

87 126% 056%

95 1.43% 061%

103 1.47% 066%

103 1.48% 066%

113 1.66% 073%

113 1.66% 073%

125 1.69% 080%

233 3 42%

1.50%

253 364% 163%

255 3.68%

1.65%

303 4.12%

1 95%

333 4.54% 2.14%

404 5.90% 2.60%

424 6.34% 2.73%

467 6.82% 3.01%

Note: Sleeve equivalent values are (31" = 9.9 and 80" = 6.3 sleeves/plug) 5

d.

Number of tubes repaired by rerolling and number of indications detected in the new roll area of the repaired tubes; There were 187 tubes in SGA and 154 in SGB where defects were repaired by re rolling within the upper tubesheet during 1R17. Post reroll eddy current testing was performed on the newly install rolls. There were no indications identified during the post reroll eddy current test.

e.

Summary of the condition monitoring and operational assessment results when applying TEC alternate repair criteria; Upper Tube End Cracking in the Heat Affected Zone This mechanism is located within the upper tubesheet and therefore is restricted from burst Tube end cracking in the heat affected zone (HAZ) of the upper tube sheet weld was detected in the three previous outages (1R14, 1R15, and 1R16). A root cause analysis concluded the degradation was primary water stress corrosion cracking (PWSCC). Prior to the 1R15 inspection the B&W Owners Group developed an alternate repair criteria (ARC) for this specific degradation mechanism. The ARC was approved for use at ANO-l by the NRC on September 14, 1999 and implemented for the first time during the 1R15 outage.

The ARC allows the tubes with the degradation to remain inservice based on meeting specific criteria such as radial position and associated flaw leakage.

Several conditions must be satisfied in order to implement the ARC. The clad thickness must be less than 0.625". The measured thicknesses are 0.25" for the "A" OTSG and 0.265" for the "B" OTSG. The ARC is also limited to axial flaws in the clad region of the HAZ. The ANO-1 analysis guidelines provide specific direction for determining the orientation of the flaws and location of the flaws relative to the clad/carbon steel interface. The ARC was not applied to indications containing circumferential, volumetric or mixed mode characteristics.

During the 1R17 inspection there were a total of 1,383 indications (SAA/MAA) detected in the HAZ area in the "A" OTSG and 797 indications in the "B" OTSG that met the criteria for the ARC.

The condition monitoring (CM) and operational assessment is calculated based on these numbers.

There were several HAZ indications having single axial (SAA) or multiple axial (MAA) flaws that were repaired during the 1R17 inspection.

Based on this information, the CM evaluation is conservative since the as-left population is less than the as-found population. The as-found CM evaluation is documented in Table 2.3 and 2.4. Additionally a 15% probability of detection (POD) factor is applied to the population to account for the flaws that were not detected. Tables 2.5 and 2.6 provide the operational assessment leakage due to the tube end PWSCC.

Since the bounding OTSG contained a number comparable to the number detected during 1R16 (1,369) this demonstrates that the POD value used is conservative. The final predicted leakage for the cycle 18 operational assessment was multiplied by the POD factor to account for new indications.

6

Table 2.3 Condition Monitoring Leakage For Upper Tubesheet Tube End Cracking ANO-1 SGA 10/02 1R17 Radius Bin Indication Flaws Per No. of PODIMAA Leakage Total Indication Indications Adjustment Per Flaw Leakage SAA 1

309 368 00261 MAA 2

191 455 0.0323 MAA 3

59 211 0.0150

<=40.00" MAA 4

12 57 0.000071 0.0040 MAA 5

1 6

0.0004 MAA 6

1 7

0.0005 MAA 8

1 10 0.0007 SAA 1

290 345 0.0656 MAA 2

171 407 0.0773 40.01-52.00 MAA 3

63 225 0.00019 0.0428 MAA 4

11 52 0.0099 MAA 5

1 6

0.0011 SAA 1

91 108 0.0414 MAA 2

78 186 0.0712 52.01-55.00 MAA 3

23 82 0.000383 0.0314 MAA 4

4 19 0.0073 MAA 5

1 6

0.0023 SAA 1

25 30 0.0162 MAA 2

17 40 0.0216 55.01-56.00 MAA 3

7 25 0.000541 0.0135 MAA 4

0 0

0.0000 MAA 5

1 6

0.0032 SAA 1

18 21 0.0288 MAA 2

5 12 0.0164

>56.00 MAA 3

2 7

0.00137 0.0096 MAA 4

1 5

0.0069 MAA 5

0 0

0.0000 TOTAL 0.5456 7

Table 2.4 Condition Monitoring Leakage For Upper Tubesheet Tube End Cracking ANO-1 SG B 10/02 1R17 Radius Bin Indication Flaws Per No. of PODIMAA Leakage Total Indication Indications Adjustment Per Flaw Leakage SAA 1

110 131 0.0093 MAA 2

25 60 0.0043 MAA 3

6 21 0.0015

<=40.00" MAA 4

1 5

0.000071 0.0004 MAA 5

0 0

0.0000 MAA 6

0 0

0.0000 MAA 8

0 0

0.0000 SAA 1

242 288 0.0547 MAA 2

110 262 0.0498 40.01-52.00 MAA 3

16 57 0.00019 0.0108 MAA 4

3 14 0.0027 MAA 5

2 12 0.0023 SAA 1

93 111 0.0425 MAA 2

43 102 0.0391 52.01-55.00 MAA 3

14 50 0.000383 0.0192 MAA 4

2 10 0.0038 MAA 5

0 0

0.0000 SAA 1

23 27 0.0146 MAA 2

17 40 0.0216 55.01-56.00 MAA 3

2 7

0.000541 0.0038 MAA 4

0 0

0.0000 MAA 5

0 0

0.0000 SAA 1

49 58 0.0795 MAA 2

30 71 0.0973

>56.00 MAA 3

9 32 0.00137 0.0438 MAA 4

0 0

0.0000 MAA 5

0 0

0.000 TOTAL 0.5008 8

Operational Assessment The growth rate values used in the TEC ARC were developed from ANO-1 specific data. A total of 232 TECs were preventatively re-rolled to reduce the accident induced leakage projection section of the operational assessment.

Tables 2.5 and 2.6 show that 0.3808 gpm must be accounted for in the "A" OTSG and 0.2659 gpm must be accounted for in the "B" OTSG. These values will be added to the other mechanisms to evaluate the total EOC 18 leakage.

Table 2.5 Operational Assessment Leakage For Upper Tubesheet Tube End Cracking ANO-1 SG A 10/02 1R17 TOTAL 0.3808 9

Radius Bin Indication Flaws Per No. of PODIMAA Leakage Total Indication Indications Adjustment Per Flaw Leakage SAA 1

308 367 00261 MAA 2

186 443 0.0315 MAA 3

58 207 0.0147

<=40.00" MAA 4

11 52 0.000071 00037 MAA 5

1 6

00004 MAA 6

1 7

00005 MAA 8

1 10 0 0007 SAM 1

286 340 0.0646 MAA 1

2 169 402 0O.0764 40.01-52.00 MAA 3

61 218 000019 0.0414 MAA 4

11 52 00099 MAAM 5

0 0 0000 SAA 1

91 108 00414 MAA 2

59 140 0.0536 52.01-55.00 MAA 3

0 0.000383 0.0000 MAA 4

0 0.0000 MAAM 5

0 0.0000 SAA 1

23 27 0.0146 MAA 2

0 0.0000 55.01-56.00 MAA 3

0 0.000541 0.0000 MAA 4

0 00000 MAA 5

-0 0.0000 SAA 1

11 0 0014 MAA 2

0 0.0000

>56.00 MAA 3

0 0.00137 0.0000 MAA 4

0 0 0000 MAA 5

0 0.0000

Table 2.6 Operational Assessment Leakage For Upper Tubesheet Tube End Cracking ANO-1 SG B 10/02 1R17 Flaws Per No. of PODIMAA Leakage Total Indication Indications Adjustment Per Flaw Leakage SAA 1

110 131 0.0093 MAA 2

25 60 0.0043 MAA 3

6 21 0.0015

<=40.00" MAA 4

1 5

0.000071 0.0004 MAA 5

0 0.0000 MAA 6

0 0.0000 MAA 8

0 0.0000 SAA 1

241 287 0.0545 MAA 2

108 257 0.0488 40.01-52.00 MAA 3

15 54 0.00019 0.0103 MAA 4

3 14 0.0027 MAA 5

2 12 0.0023 SAA 1

91 108 0.0414 MAA 2

43 102 0.0391 52.01-55.00 MAA 3

8 29 0.000383 0.0111 MAA 4

0 0.0000 MAA 5

0 0.0000 SAA 1

22 26 0.0141 MAA 2

13 31 0.0168 55.01-56.00 MAA 3

0 0.000541 0.0000 MAA 4

0 0.0000 MAA 5

0 1 0.0000 SAA 1

2 2

0.0027 MAA 2

2 5

0.0069

>56.00 MAA 3

0 0.00137 0.0000 MAA 4

0 0.0000 MAA 5

0 0.0000 TOTAL 0.2659 10

f.

Summary of the condition monitoring and the operational assessment results (including growth) when applying the upper tubesheet ODIGA alternate repair criteria.

Upper Tubesheet Volumetric IGA This mechanism is located within the upper tubesheet and therefore is restricted from burst.

Intergranular Attack (IGA) in the upper tubesheet has been present since the early 1980's and has demonstrated little change. The high sulfate concentration which initiated the degradation has not recurred, therefore the initiation of new IGA patches is essentially zero.

An ARC has been implemented for the IGA during the previous three cycles (15, 16 and 17), and a similar approach is being implemented during cycle 18. A licensing basis change was approved by the NRC prior to the 1R16 outage12). The ARC allows the IGA detected during future outages to remain inservice provided certain growth and leakage criteria are satisfied.

Growth Assessment In order to assess the change in flaw characteristics or growth, two parameters were evaluated, plus-point amplitude (volts) and axial extent from the 0.115" pancake coil.

Of the available parameters, these two provide the most consistent indication of the IGA characteristics and therefore provide the best indication of growth. The approach for comparing growth includes three statistical tests, a sign test, a paired t-test and an extreme value test. If all three tests pass then it is concluded that the population is not changing.

There were a total of 292 tubes containing 335 IGA patches detected during the 1 RI 7 outage in the "A" OTSG and a total of 151 tubes containing 226 IGA patches in the "B" OTSG. Of the flaws detected, there were 312 patches in "A" and 198 patches in "B" that contained a previous plus point/0.1 15" pancake coil exam from 1R16. The growth comparisons are made on this population.

The following Table 2.7 provides a summary of the growth comparisons and acceptance criteria.

As can be seen from the results all of the criteria were satisfied.

Table 2.7 OTSG IGA Growth Summary Plus Point Volts 1

Axial Extent SG A SGB I SGA I SGB Number of Data Points 312 198 312 198 Average Change

-0.0040 0.0078 0.0028 0.0045 Standard Deviation Change 0.0412 0.0731 0.0415 0.0416 Maximum Change 0.120 0.230 0.080 0.110 Number of Positive Values 147 103 143 104 Sign Test Results Critical Value 171 111 171 ill Growth Test Results Sat Sat Sat Sat Average Change j -0.0040 0.0078 0.0028 0.0045 Paired T-Test Results Critical Value 0.0038 0.0086 0.0039 0.0049 Growth Test Results Sat Sat Sat Sat Mean Extreme 0.1187 0.2001 0.1199 0.1135 Extreme Value Test Standard Deviation Extreme 0.0163 0.0296 0.0157 0.0166 Results 95-95 Extreme 0.1491 0.2553 0.1492 0.1445 Extreme Test Results Sat Sat Sat Sat I1

Leakage Assessment for UTS Volumetric ODIGA Reference 1 describes the method for estimating the leakage due to the upper tubesheet ODIGA.

This process uses a hypergeometric distribution to determine the number of indications that must be assumed to leak.

It is based on the total number of indications detected and the number of indications previously leak tested via either lab testing or in situ testing. There have been a total of 34 indications in SGA and 20 indications in SGB that have been previously in-situ tested. None of the indications tested showed signs of leakage.

Using the hypergeometric distribution, the number of leakage contributors is determined based on the population size and the number of flaws previously tested. The number of leakage contributors is calculated at a 95% confidence level. For example, for SGA, there were 335 upper tubesheet indications detected, and 0 of 34 previously tested indications showed leakage. The result from the hypergeometric distribution was 33 indications. Therefore, there is 95% confidence that less than or equal to 33 indications will leak under MSLB conditions, based on the fact that 0 of 34 tested indications leaked.

To determine the condition monitoring leakage contribution for the upper tubesheet ODIGA indications, each flaw is first assigned a leakage value based on its axial extent. Table 2.8 shows the relationship between the axial extent and the leak rate. The flaws are then sorted based on descending axial extent.

It is assumed that the longest flaws are the ones that leak.

The hypergeometric distribution is then used to determine the number of leakage contributors (call this value "X'). Then the leakage for the "X" longest flaws are added together to obtain the MSLB leakage for upper tubesheet ODIGA. Therefore, for SGA, the leakage from the 33 longest flaws was added together.

Since the "no growth" hypothesis was supported by the tests referenced in Section 2.f, the operational assessment simply removes the indications from the distribution that were removed

-from service, i.e., no growth distribution is required. There were a total of fourteen upper tubesheet ODIGA indications that were removed from service (six in SGA and eight in SGB). One of the repaired indications in SGB was removed from service by plugging due to a volumetric indication in the one-inch exclusion zone at the secondary face of the tubesheet. Nine of the repaired indications were in tubes that were preventatively plugged in response to recent operating experience at other OTSG's (Ref. 5). The other ODIGA indications were removed from service due to other indications in the tubes.

Taking the repairs into account, the hypergeometric distribution was used to determine the number of leakage contributors for the operational assessment. Tables 2.9 and 2.10 show the results of the leakage assessments for the upper tubesheet ODIGA.

12

Table 2.8 ODIGA Leak Rate vs. Axial Extent Axial Extent (inches)

Leak Rate (gpm) 0.01-0.20 0.00030 0.21-0.40 0.0026 0.41-0.60 0.0150 0.61-0.80 0.0485 0.81-1.00 0.1422 1.01-1.20 0.3415 1.21-1.40 0.6680 Table 2.9 Condition Monitoring Assessment for Upper Tubesheet ODIGA Leakage Number of Detected Indications 335 226 POD Adjustment 33.5 22.6 Previous Testing Adjustment 34 20 Population 402.5 268.6 Leakers In Sample 0

0 Assumed Leakers In Population 33 37 UTS IGA Leakage (gpm) 0.111 0.096 Table 2.10 Operational Assessment for Upper Tubesheet ODIGA Leakage SG A SG B Number of Detected Indications 335 226 Indications Repaired 6

8 POD Adjustment 33.5 22.6 Previous Testing Adjustment 34 20 Population 395.4 261.6 Leakers In Sample 0

0 Assumed Leakers In Population 32 35 UTS IGA Leakage (gpm) 0.108 0.091 13 SG B SG A

3.0 Total Leakage The operational assessment for the remainder of the cycle is complete. Table 3.1 lists all the mechanisms that were accounted for and the associated leakage. The summed total leakage for all mechanisms was 0.74 gpm at MSLB conditions which is less than the performance criteria of 1.0 gpm.

Table 3.1 Summary of Results 1R18 OA Leakage Estimate Mechanism Projected Leakage 14 Upper Tubesheet IGA 0.106 ARC Upper Roll PWSCC 0.011 Axial Upper Roll PWSCC 0.139 Circumferential Re-roll Cracking Upper Expansion 0.007 Re-roll Cracking Lower Expansion 0.004 HAZ PWSCC TEC 0.381 ARC Sleeve Cracking 0.000 Freespan Groove Axial 0.000 IGA Cracking Freespan Volumetric 0.000 TSP Wear 0.000 TSP Cracking 0.030 Axial UTS Cracking 0.010 Axial TSP Cracking 0.025 Circumferential TSP Cracking 0.000 Volumetric LTS Cracking 0.030 Axial Volumetric in Dents 0.000 Other Degradaton/-hardware 0.02 gpm Total of all Degradation Mechanism 0.74 SAR Limit for Leakage 1.00

4.0 Summary A comprehensive eddy current examination was performed on the OTSGs to look for various degradation mechanisms. The techniques used were qualified or demonstrated equivalent with the EPRI PWR Steam Generator Examination Guidelines. Several modes of degradation were detected during the exams. By benchmarking actual inspection results with previous projections, reasonable projections can be made for EOC 18. The structural aspects of the various modes of degradation are either bound by previous in-situ testing or considered not a concern based on location within the tubesheet (e.g., URT, re-roll flaws).

Additionally, the HAZ flaws and the upper tubesheet IGA are being addressed through specific Technical Specification requirements. The conclusion of this condition monitoring evaluation is that none of the performance criteria in NEI-97-06 were exceeded and based on the comprehensive exams performed it is concluded that the EOC 18 condition would not exceed the performance criteria. The combined EOC accident induced leakage values are provided in Table 3.1. As shown in Table 3.1, the total leakage contribution is approximately 0.74 gpm. Therefore, based on this evaluation, Entergy Operations has concluded that the OTSGs pose no concern relative to the safe operation of the plant or the health and safety of the public for the remainder of cycle 18.

5.0 References

1.

Engineering Report 00-R-1005-01, Rev. 1, Management Program for Volumetric ODIGA in the Upper Tubesheets of OTSGs at Arkansas Nuclear One - Unit One

2.

Amendment 213 to facility operating license No. DPR-5 1-Arkansas Nuclear One, Unit No.

1 (TAC No. MA 9879)

3.

1CAN040101, Special Report - ANO-1 Steam Generator C-3 Report For 1R16

4.

1 CAN010001, Once Through Steam Generator Inservice Inspection Report

5.

ER-ANO-2002-0820, ANO-1 1R17 Impact on Recent OE's at OTSG 15

TABLE 4 ANO-i "A" OTSG 1R17 WEAR RESULTS ROW TUBE IND

%TW LOCATION STATUS REPAIR

1.

2 8

WAR 5

loS

+0.43 INSERVICE WEAR <40 2

3 3

WAR 7

11S

+022 INSERVICE WEAR <40

3.

3 5

WAR 12 11S

-028 INSERVICE WEAR <40

4.

3 5

WAR 14 1OS

+0.38 INSERVICE WEAR <40

5.

3 6

WAR 6

1IS

-0.55 INSERVICE WEAR <40

6.

3 7

WAR 15 10S

+0.36 INSERVICE WEAR <40

7.

4 1

WAR 7

10S

+0.60 INSERVICE WEAR <40

8.

4 16 WAR 7

loS

+0.60 INSERVICE WEAR <40

9.

4 34 WAR 16 09S

-0.33 INSERVICE WEAR <40

10.

5 1

WAR 10 loS

+0.36 INSERVICE WEAR <40

11.

5 22 WAR 7

08S

-0.66 INSERVICE WEAR <40

12.

5 22 WAR 4

09S

+0.64 INSERVICE WEAR <40

13.

5 37 WAR 13 09S

-0.07 INSERVICE WEAR <40

14.

5 45 WAR 9

09S

-0.81 INSERVICE WEAR <40

15.

6 41 WAR 8

08S

-0.57 INSERVICE WEAR <40

16.

6 41 WAR 9

09S

-008 INSERVICE WEAR <40

17.

6 41 WAR 11 08S

-0.54 INSERVICE WEAR <40

18.

6 41 WAR 10 08S

+0.61 INSERVICE WEAR <40

19.

7 50 WAR 5

08S

+0.64 INSERVICE WEAR <40

20.

7 54 WAR 7

loS

+0.58 INSERVICE WEAR <40

21.

8 57 WAR 5

loS

+0.55 INSERVICE WEAR <40

22.

9 2

WAR 8

09S

+0.31 INSERVICE WEAR <40

23.

9 3

WAR 7

09S

-039 INSERVICE WEAR <40

24.

9 60 WAR 6

loS

+0.62 INSERVICE WEAR <40

25.

9 61 WAR 12 loS

+0.66 INSERVICE WEAR <40 26 10 7

WAR 13 08S

+0.04 INSERVICE WEAR <40

27.

10 7

WAR 23 08S

-0.40 INSERVICE WEAR <40

28.

10 12 WAR 3

07S

+0.70 INSERVICE WEAR <40

29.

11 59 WAR 3

09S

-0.85 INSERVICE WEAR <40

30.

11 61 WAR 5

07S

+0.32 INSERVICE WEAR <40

31.

11 67 WAR 6

10S

+0.62 INSERVICE WEAR <40

32.

12 2

WAR 11 09S

+0.16 INSERVICE WEAR <40

33.

12 10 WAR 9

07S

-0.13 INSERVICE WEAR <40

34.

12 61 WAR 9

07S

-0.24 INSERVICE WEAR <40 35 12 68 WAR 16 10S

+0.48 INSERVICE WEAR <40

36.

12 69 WAR 20 loS

+0.57 INSERVICE WEAR <40

37.

12 70 WAR 15 10S

+0.64 INSERVICE WEAR <40

38.

13 71 WAR 15 10S

+0.70 INSERVICE WEAR <40

39.

13 73 WAR 10 loS

+0.66 INSERVICE WEAR <40

40.

14 31 WAR 7

08S

-032 INSERVICE WEAR <40

41.

14 73 WAR 6

10S

+0.60 INSERVICE WEAR <40

42.

14 75 WAR 5

10S

+0.53 INSERVICE WEAR <40

43.

15 16 WAR 9

07S

+0.45 INSERVICE WEAR <40

44.

15 77 WAR 12 1OS

+0.64 INSERVICE WEAR <40

45.

16 14 WAR 13 08S

+0.06 INSERVICE WEAR <40

46.

16 80 WAR 16 lOS

+0.68 INSERVICE WEAR <40

47.

17 18 WAR 17 08S

-049 INSERVICE WEAR <40

48.

18 78 WAR 11 08S

+0.66 INSERVICE WEAR <40 16

TABLE 4 ANO-1 "A" OTSG 1R17 WEAR RESULTS

49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.

85

86.
87.
88.
89.
90.
91.
92.
93.

94

95.
96.

97.

ROW 18 18 19 19 19 19 20 20 21 22 22 22 22 23 23 23 24 25 25 25 25 25 26 26 28 29 29 31 31 31 32 32 32 32 34 35 35 37 37 37 38 38 39 40 41 42 43 44 44 TUBE 80 84 78 80 83 83 75 84 86 68 82 87 88 4

82 94 48 1

4 36 89 98 39 47 1

1 6

101 103 104 4

5 6

87 7

32 37 5

6 113 93 112 98 114 115 115 45 58 76 IND WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR

%TW 14 7

7 4

9 8

21 11 8

10 15 15 12 7

18 6

8 4

5 6

6 7

6 5

9 14 16 8

2 8

12 19 7

6 6

8 13 10 9

10 10 13 6

13 5

17 7

7 9

LOCATION 09S

-066 10S

+0.59 08S

+0.57 08S

+0.64 09S

-0.39 08S

-075 08S

-029 lS

-0.79 07S

-0.30 07S

-0.23 08S

-0.29 08S

-0.07 07S

-064 03S

+069 08S

+0.64 1OS

+066 07S

-0.24 14S

-0.75 09S

-0.75 08S

+0.53 07S

+0.55 05S

-0.32 08S

-0.31 05S

+0.48 loS

+0.58 1OS

-0.55 09S

+0.56 09S

-0.41 05S

-0.18 08S

+0.59 09S

+0.52 09S

+0.62 09S

+0.57 07S

-0.53 08S

+0.50 07S

-0.36 07S

-0.15 09S

+0.62 09S

+0.59 13S

-0.77 07S

-0.62 09S

-0.39 08S

-0.23 08S

+0.59 08S

+0.58 08S

+0.57 06S

+0.60 06S

-0.51 07S

-0.39 STATUS INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE REPAIR WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 17

TABLE 4 ANO-1 "A" OTSG 1R17 WEAR RESULTS

98.
99.

100.

101.

102.

103.

104.

105.

106.

107.

108.

109.

110.

111.

112.

113.

114.

115.

116.

117.

118.

119.

120.

121.

122.

123.

124.

125.

126.

127.

128.

129.

130 131.

132.

133.

134.

135.

136.

137.

138.

139.

140.

141.

142.

143.

144.

145.

146.

ROW 45 47 47 48 48 49 49 49 50 50 50 50 50 52 52 52 52 52 52 52 53 53 54 54 54 54 54 55 55 55 56 56 56 57 57 57 57 57 58 58 58 59 60 60 60 60 61 61 62 TUBE 105 2

11 3

24 33 59 121 2

11 30 67 101 50 65 67 67 67 73 120 27 68 47 56 61 64 75 4

55 67 58 63 125 64 67 67 69 70 42 79 125 52 77 87 89 98 100 113 26 IND WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR

%TW 9

13 8

5 4

16 7

7 10 8

11 9

11 8

7 6

4 9

8 7

13 15 7

6 4

6 6

7 11 5

21 5

5 4

5 7

6 12 7

9 11 6

6 8

8 7

11 8

4 LOCATION 08S

-042 09S

+0.67 09S

+0.59 09S

+0.57 07S

+0.29 09S

+0.62 05S

+0.51 05S

-0.05 09S

+0.58 09S

+0.59 08S

+0.39 06S

+0.39 07S

+0.20 05S

+0.47 06S

+0.55 05S

+0.56 06S

+0.70 07S

+0.66 06S

+0.46 09S

-0.69 12S

+0.83 06S

+0.62 07S

+0.47 05S

+0.53 05S

+0.48 05S

+0.55 05S

+0.53 08S

+0.49 06S

+0.60 06S

+0.20 07S

+0.62 06S

+0.55 08S

+0.22 05S

+0.37 07S

+0.68 06S

+0.27 05S

+0.66 06S

+0.23 05S

+0.53 06S

+0.20 09S

-0.70 06S

+0.75 06S

-0.02 15S

+0.57 07S

-055 06S

+0.63 05S

+0.68 08S

-0.52 06S

+0.71 STATUS INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE REPAIR WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 18

TABLE 4 ANO-1 "A" OTSG 1R17 WEAR RESULTS ROW 147.

62 148.

62 149.

62 150.

63 151.

63 152.

63 153.

63 154.

64 155.

64 156.

65 157.

65 158.

65 159.

65 160 65 161.

65 162.

65 163.

65 164.

66 165.

66 166.

66 167.

66 168.

67 169.

67 170.

67 171.

68 172.

68 173.

68 174.

68 175.

68 176.

68 177.

69 178 69 179.

69 180.

69 181.

69 182.

69 183.

69 184.

69 185.

70 186.

70 187.

70 188 70 189.

70 190. 70 191.

70 192.

71 193.

71 194.

71 195.

71 TUBE 111 126 129 80 89 124 127 73 123 2

41 58 58 77 92 118 123 25 109 125 126 47 114 119 3

28 53 57 85 96 28 53 72 72 73 98 118 122 73 95 98 116 125 126 130 58 64 67 77 IND WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR

%TW 13 9

15 10 17 10 10 4

11 11 25 9

8 16 4

17 5

4 16 7

10 12 6

9 4

12 15 7

20 14 7

14 14 8

11 6

7 8

8 10 3

5 6

10 8

7 3

7 10 LOCATION 08S

-0.87 09S

-0.83 1OS

+0.60 06S

-0.26 06S

-0.64 08S

+0.63 09S

+0.61 06S

+0.26 08S

+0.65 09S

+0.55 06S

+0.64 08S

-0.58 07S

+0.76 06S

-0.52 06S

-0.39 08S

-0.51 08S

+0.69 07S

+0.50 07S

-0.29 08S

+0.65 08S

+0.57 09S

+0.75 06S

+062 06S

+060 09S

+0.52 09S

+0.68 09S

+0.69 09S

-0.19 06S

-097 06S

+0.22 1OS

+0.73 09S

+064 09S

+056 09S

-0.58 09S

-0.65 06S

+0.67 06S

+0.60 06S

+0.65 06S

-0.17 06S

-0.59 06S

+0.60 06S

+0.51 08S

+0.60 08S

+0.66 llS

-054 08S

+0.65 08S

+0.67 07S

+0.52 07S

+0.53 STATUS INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 19 REPAIR WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40

TABLE 4 ANO-1 "A" OTSG 1R17 WEAR RESULTS 196.

197.

198.

199.

200.

201.

202.

203.

204.

205.

206.

207.

208.

209.

210.

211.

212.

213.

214.

215.

216.

217.

218.

219.

220.

221.

222.

223.

224.

225.

226.

227.

228.

229.

230.

231.

232.

233.

234.

235.

236.

237.

238.

239.

240.

241.

242.

243.

244.

ROW 71 71 71 71 72 72 72 72 72 72 72 72 72 73 73 73 73 73 73 73 73 73 73 73 73 74 74 74 74 74 75 75 75 75 75 75 76 76 76 76 76 76 77 77 77 77 77 79 79 20 TUBE 91 105 115 131 9

11 46 71 71 73 84 88 130 55 57 59 69 73 73 73 83 93 117 119 130 4

30 99 115 116 26 90 113 115 115 118 69 92 94 109 110 122 37 37 68 69 72 29 36 IND WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR

%TW LOCATION 6

06S

+0.33 12 06S

+0.52 9

06S

+0.55 7

lOS

+0.52 10 09S

+049 8

09S

+0.36 3

07S

+0.78 8

07S

+0.07 14 08S

-0.19 12 09S

-0.70 10 06S

-0.58 6

07S

-0.55 6

lOS

+0.59 12 07S

+0.69 9

lOS

+0.27 7

09S

+0.73 11 11S

+0.68 5

08S

-072 7

09S

+0.63 6

03S

+0.70 10 06S

-0.49 15 06S

-0.11 3

06S

+0.53 3

06S

+0.55 13 11S

-0.34 8

11S

+0.63 13 08S

+0.49 6

06S

+0.63 11 06S

+0.54 7

06S

+0.51 8

04S

-0.73 8

06S

-0.11 3

06S

+0.57 8

08S

-023 2

06S

+0.55 9

06S

+0.56 12 09S

-0.70 5

06S

-0.33 6

07S

-0.56 6

06S

+0.53 6

06S

+0.50 11 08S

-009 11 08S

+0.06 12 08S

+0.31 14 09S

-0.65 5

09S

-0.68 6

08S

-0.66 7

11S

-0.42 12 12S

-0.55 STATUS INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE REPAIR WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40

TABLE 4 ANO-1 "A" OTSG 1R17 WEAR RESULTS 245.

246.

247.

248.

249.

250.

251.

252.

253.

254.

255.

256.

257.

258 259.

260.

261.

262.

263.

264.

265.

266.

267.

268.

269.

270.

271.

272.

273.

274.

275.

276.

277.

278.

279.

280.

281.

282.

283.

284.

285.

286.

287.

288.

289.

290.

291.

292.

293.

ROW 79 79 79 79 80 80 80 80 80 80 80 80 81 81 81 81 81 82 82 82 82 82 82 82 82 82 83 83 83 83 83 83 83 84 84 84 84 84 85 85 85 85 86 86 86 86 86 86 87 TUBE 36 70 80 121 49 51 51 53 53 53 58 92 32 43 47 71 130 7

27 52 52 54 54 56 70 127 45 50 50 53 54 58 75 5

11 52 77 82 37 52 53 94 12 13 16 17 46 87 12 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR

%TW 8

21 5

4 13 6

8 11 7

4 4

4 5

6 7

8 4

7 6

8 8

9 7

14 21 10 7

7 8

14 6

15 6

9 4

13 11 5

11 12 11 7

5 5

10 12 9

9 10 LOCATION llS

+0.59 08S

-0.74 03S

+0.47 06S

+0.56 08S

+0.55 07S

+0.75 08S

+0.55 07S

-0.66 08S

+0.60 07S 40.55 08S

-057 05S

+0.27 09S

-0.78 11S

+0.83 07S

-0.70 08S

-0.45 09S

+0.67 08S

+0.61 13S

+0.70 08S

-0.64 08S

+0.18 08S

-0.62 08S

+0.04 08S

-0.72 08S

-068 07S

-0.72 09S

-0.68 09S

-0.37 09S

-0.72 08S

-0.47 08S

-065 09S

-0.65 07S

-061 08S

+040 06S

+0.29 09S

-0.43 06S

-0.61 06S

+0.29 09S

-0.70 09S

-0.44 08S

-0.46 06S

+0.33 1OS

-0.78 1OS

-0.72 1OS

-0.75 1OS

-0.71 05S

+0.51 06S

+0.65 1OS

-0.51 STATUS INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE REPAIR WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 21

TABLE 4 ANO-1 "A" OTSG 1R17 WEAR RESULTS 294.

295.

296.

297.

298.

299.

300.

301.

302.

303.

304.

305.

306.

307.

308.

309.

310.

311.

312.

313.

314.

315.

316.

317.

318.

319.

320.

321.

322.

323.

324.

325.

326.

327.

328.

329.

330.

331.

332.

333.

334.

335.

336.

337.

338.

339.

340.

341.

342.

ROW 87 87 87 87 91 91 91 91 93 93 93 94 94 94 95 95 98 98 98 99 99 100 100 100 100 100 101 101 101 102 102 102 102 103 103 103 103 104 104 104 104 104 105 105 105 105 105 106 106 TUBE 22 22 50 58 5

41 81 84 2

76 84 24 52 127 53 109 59 59 64 60 119 9

20 62 99 99 69 76 108 49 62 77 95 64 71 82 119 4

8 39 43 74 7

40 44 73 80 4

4 IND WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR

%TW 5

4 4

4 7

15 3

9 10 3

10 4

6 8

15 5

7 10 5

7 6

6 3

7 8

6 6

4 3

7 9

5 12 6

5 6

6 7

5 9

16 4

9 11 5

7 5

5 12 LOCATION 09S

-0.72 08S

+0.20 08S

-018 05S

+0.58 08S

+0.42 07S

+0.12 07S

-0.42 05S

+033 09S

+0.52 06S

+0.06 15S

+0.92 08S

-0.52 05S

+0.62 08S

+0.56 03S

+0.08 05S

+0.44 05S

+0.60 06S

-0.77 05S

+0.40 05S

+0.52 09S

-0.48 09S

-0.74 15S

+0.76 05S

+0.49 07S

+0.22 07S

+0.20 05S

+0.62 06S

-0.31 06S

+0.36 05S

+0.56 07S

-067 05S

+0.58 14S

+0.36 05S

+0.50 06S

+0.15 06S

-0.07 09S

-0.62 1OS

+053 06S

+0.51 07S

+0.58 07S

+0.62 07S

-062 06S

+0.42 07S

+0.13 05S

+0.56 06S

-0.23 12S

+0.27 07S

+0.42 1OS

+0.71 STATUS INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 1NSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE REPAIR WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 22

TABLE 4 ANO-1 "A" OTSG 1R17 WEAR RESULTS 343.

344.

345.

346.

347.

348.

349.

350.

351.

352.

353.

354.

355.

356.

357.

358.

359.

360.

361.

362.

363.

364.

365.

366.

367.

368 369 370.

371.

372.

373.

374.

375.

376.

377.

378 379.

380.

381.

382.

383.

384.

385.

386.

387.

388.

389.

390.

391.

ROW 106 106 106 107 107 107 108 108 108 108 108 108 109 109 109 109 110 110 110 110 110 111 111 111 111 111 111 112 112 112 112 113 113 113 114 115 115 115 115 115 116 116 116 116 119 120 121 121 121 TUBE 7

8 66 2

4 69 4

46 50 51 54 68 1

2 41 52 13 51 53 63 90 7

50 53 58 68 102 39 71 80 90 3

24 47 44 4

8 38 48 50 31 81 92 97 42 47 4

19 52 IND WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR

%TW 5

5 4

4 9

5 6

3 5

8 13 7

11 6

11 5

5 13 8

12 6

3 7

11 6

7 1

6 4

9 4

8 7

4 6

6 18 6

5 6

11 8

6 9

7 15 7

16 8

LOCATION 06S

+0.42 06S

+0.51 05S

-0.44 08S

+0.44 1OS

+060 06S

+0.45 1OS

+0.62 06S

+0.15 05S

+0.36 05S

+0.58 05S

+0.40 06S

-0.05 01S

-0.65 08S

+0.42 07S

+0.52 05S

+0.63 08S

+0.40 05S

+0.54 05S

+0.40 07S

+0.00 06S

+0.43 08S

+0.40 05S

+0.60 05S

+0.41 05S

+0.50 07S

-0.51 03S

+0.00 07S

+0.18 06S

-0.15 07S

+0.14 07S

-0.48 08S

+0.50 08S

-0.08 06S

+045 07S

+029 08S

+0.37 08S

+0.42 06S

+0.52 06S

+0.25 06S

+0.18 07S

+0.58 02S

+0.49 15S

+0.90 08S

+0.49 07S

-0.33 06S

+0.62 08S

+0.51 08S

-0.40 08S

+0.81 STATUS INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE REPAIR WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 23

TABLE 4 ANO-1 "A" OTSG 1R17 WEAR RESULTS 392.

393.

394.

395.

396.

397.

398.

399.

400.

401.

402.

403.

404.

405.

406.

407.

408.

409.

410.

411.

412.

413.

414.

415.

416.

417.

418.

419.

420.

421.

422.

423.

424.

425.

426.

427.

428.

429.

430.

431.

432.

433.

434.

435.

436.

437.

ROW 121 122 123 124 125 125 125 125 126 126 128 129 130 130 132 132 132 133 133 134 134 135 136 143 144 147 148 149 149 149 149 149 149 150 150 150 150 150 150 150 150 151 151 151 151 151 24 TUBE 88 10 93 67 1

7 77 86 7

42 9

93 6

54 22 30 83 5

61 42 82 2

3 49 6

40 7

2 26 27 28 28 30 10 12 18 19 20 21 21 27 5

9 10 13 15 IND WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR

%TW LOCATION 3

07S

-0.02 4

09S

+0.53 3

06S

+0.61 9

06S

+055 7

10S

+0.49 8

08S

+0.63 5

07S

-0.47 3

07S

-0.42 11 08S

+0.63 6

03S

-078 7

06S

-0.26 5

1OS

+0.45 6

1OS

+0.63 12 07S

-0.49 18 07S

+0.38 4

07S

-0.47 7

1OS

-0.74 7

06S

+0.65 9

07S

+0.00 10 08S

-0.53 5

09S

-0.14 5

1OS

+0.63 6

1OS

+0.55 9

03S

+0.45 7

08S

-027 6

11S

+0.38 4

08S

+0.18 19 09S

+0.35 4

1OS

+0.61 6

lOS

+0.69 5

1OS

-0.74 4

lOS

+0.70 5

1OS

-0.55 7

1OS

+0.64 6

1OS

+0.62 11 1OS

-054 12 10S

+0.79 8

10S

+066 8

1OS

+0.56 5

1OS

-0.66 12 1OS

+064 10 1OS

+0.69 5

11S

-0.46 7

07S

-0.82 8

llS

-019 4

10S

+0.63 STATUS INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE REPAIR WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40

TABLE 5 ANO-1 "B" OTSG 1R17 WEAR RESULTS ROW TUBE IND

%TW LOCATION STATUS

1.
2.
3.
4.
5.
6.
7.

8

9.
10.
11.
12.
13.

14

15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.

48 REPAIR 1

2 3

3 4

4 4

4 4

4 4

4 5

5 5

5 5

5 6

6 6

6 6

6 7

7 7

7 7

7 7

8 10 10 11 11 11 11 12 12 12 12 12 13 13 13 13 13 7

4 16 33 1

11 14 15 21 28 32 41 3

7 9

14 15 16 9

12 14 15 22 39 13 14 18 33 33 44 45 22 8

65 4

6 6

21 34 66 70 71 71 1

2 3

63 63 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 5

6 3

9 12 8

5 12 10 4

8 16 11 5

14 6

12 14 6

10 6

9 6

12 21 3

4 6

6 12 8

8 11 6

7 8

7 7

6 7

7 6

7 6

7 5

7 4

25 13S 14S 08S 1Os 11S los los los 14S 09S 08S lS 11S los los los los 10S los 10S los los 1os los 09S 03S 14S 14S 13S 09S 07S 09S los lS 05S 08S 08S 14S 03S 07S l1S 14S lS 05S 07S 05S 07S 07S

-0.72

-0.83

+0.74

-0.73

+0.68

+0.58

+0.58

+0.56

-0.78

-0.51

+0.51

+0.71

+0.68

+0.49

+0.56

+0 67

+0.52

+0.62

+0.66

+0.66

+0.49

+0.60

-0.85

-0.77

-0.75

+0.69

-0.81

-0.78

-0.71

+0.23

-034

-068

-0.78

+0.80

-0.75

+0.50

-0.18

-085

+0.67

-0.52

+0.58

-0.74

+0.56

-0.76

+0.61

-0.70

+067

+0.16 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40

TABLE 5 ANO-1 "B" OTSG 1R17 WEAR RESULTS

49.

50

51.
52.
53.
54.
55.
56.
57.

58

59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
88.
89.
90.
91.
92.
93.
94.
95.
96.
97.

98.

14 14 15 15 16 16 16 16 16 16 17 18 19 20 21 22 22 22 22 23 23 23 24 24 24 24 24 26 27 28 28 28 29 29 29 30 30 30 30 32 32 32 32 32 32 32 32 33 33 33 6

74 56 73 1

2 11 52 70 75 51 85 48 83 15 1

1 43 91 6

32 91 1

1 3

19 47 69 44 28 44 56 15 39 70 11 23 82 101 5

6 7

7 7

19 82 86 43 107 108 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 5

10 14 5

5 10 12 8

9 5

4 5

9 9

11 7

5 4

7 12 11 4

4 10 7

4 5

14 4

9 7

5 8

6 11 8

8 8

14 9

11 8

19 7

15 6

7 9

17 26 06S 1is los 07S 14S 14S 08S los 05S los 07S 03S 07S los 08S 14S 14S 03S 10S 09S lOS 08S lis 03S lOS 08S 07S 08S 05S 07S 07S 08S 07S 14S 07S 14S 07S 08S 14S 09S 12S l1S 13S 12S 07S 08S 15S 07S los 14S

-0.32

-0.60

-0.79

-0.54

-0.82

-0.86

-0.76

+0.75

-0.68

+0.36

+0.58

-0.74

+0.41

+0.57

-0.73

-0.78

+0.54

+065

+0.61

-0.81

-0.80

-0.55

+0.76

+0.68

+0.57

-044

+0.48

-0.55

+0.26

+0.55

-0.12

-0.69

-0.43

-0.66

-0.48

-0.87

-0.65

-0.55

-0.71

-0.63

-0.72

+0.63

-0.68

-0.67

-0.39

-0.60

+0.46

+0.19

-0.75

-0.76 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40

TABLE 5 ANO-1 "B" OTSG 1R17 WEAR RESULTS

99.

34 20 WAR 5

05S

-0.43 INSERVICE WEAR <40 100.

34 23 WAR 7

07S

-0.41 INSERVICE WEAR <40 101.

34 25 WAR 7

07S

-0.26 INSERVICE WEAR <40 102.

34 36 WAR 7

07S

-0.10 INSERVICE WEAR <40 103.

34 105 WAR 6

08S

-0.22 INSERVICE WEAR <40 104.

34 107 WAR 5

08S

+0.70 INSERVICE WEAR <40 105.

36 5

WAR 5

08S

-0.21 INSERVICE WEAR <40 106.

36 13 WAR 13 11S

-0.61 INSERVICE WEAR <40 107.

36 20 WAR 9

05S

-0.03 INSERVICE WEAR <40 108.

36 28 WAR 7

07S

+0.54 INSERVICE WEAR <40 109.

36 102 WAR 6

15S

+0.76 INSERVICE WEAR <40 110.

36 111 WAR 11 08S

+0.68 INSERVICE WEAR <40 111.

36 113 WAR 9

14S

-066 INSERVICE WEAR<40 112.

37 34 WAR 7

07S

-0.73 INSERVICE WEAR <40 113.

38 60 WAR 7

loS

-0.74 INSERVICE WEAR <40 114.

38 111 WAR 10 14S

-0.75 INSERVICE WEAR <40 115.

39 57 WAR 12 09S

-0.78 INSERVICE WEAR <40 116.

39 98 WAR 8

13S

-080 INSERVICE WEAR <40 117.

40 2

WAR 7

10S

+0.70 INSERVICE WEAR <40 118.

40 50 WAR 10 06S

+0.48 INSERVICE WEAR <40 119.

40 106 WAR 7

15S

+0.73 INSERVICE WEAR <40 120.

40 117 WAR 9

14S

-0.49 INSERVICE WEAR <40 121.

41 106 WAR 7

15S

+0.75 INSERVICE WEAR <40 122.

41 110 WAR 14 12S

+0.59 INSERVICE WEAR <40 123.

41 110 WAR 14 13S

+0.57 INSERVICE WEAR <40 124.

41 110 WAR 23 14S

-0.80 INSERVICE WEAR <40 125.

41 113 WAR 7

13S

-0.80 INSERVICE WEAR <40 126.

42 4

WAR 19 08S

-0.57 INSERVICE WEAR <40 127.

42 29 WAR 13 08S

+0.05 INSERVICE WEAR <40 128.

43 30 WAR 9

07S

+0.54 INSERVICE WEAR <40 129.

43 41 WAR 8

07S

-0.47 INSERVICE WEAR <40 130.

44 54 WAR 9

los

-0.80 INSERVICE WEAR <40 131.

44 92 WAR 12 08S

-0.73 INSERVICE WEAR <40 132.

44 119 WAR 7

09S

+0.11 INSERVICE WEAR <40 133 45 35 WAR 10 07S

-0.12 INSERVICE WEAR <40 134.

45 37 WAR 6

08S

-0.48 INSERVICE WEAR <40 135.

46 6

WAR 8

06S

-0.32 INSERVICE WEAR <40 136.

47 9

WAR 8

05S

-0.69 INSERVICE WEAR <40 137.

47 23 WAR 4

08S

-0.30 INSERVICE WEAR <40 138.

47 32 WAR 8

07S

-0.28 INSERVICE WEAR <40 139.

47 119 WAR 1

09S

-0.83 INSERVICE WEAR <40 140.

48 117 WAR 10 14S

-0.72 INSERVICE WEAR <40 141.

48 118 WAR 5

08S

-0.72 INSERVICE WEAR <40 142.

49 35 WAR 8

09S

-0.81 INSERVICE WEAR <40 143.

49 119 WAR 6

08S

-0.73 INSERVICE WEAR <40 144.

49 121 WAR 5

14S

-0.72 INSERVICE WEAR <40 145.

49 124 WAR 8

13S

+0.64 INSERVICE WEAR <40 146.

50 6

WAR 12 14S

-0.69 INSERVICE WEAR <40 147.

50 35 WAR 11 07S

-0.64 INSERVICE WEAR <40 148.

50 119 WAR 11 14S

-0.75 INSERVICE WEAR <40 27

TABLE 5 ANO-1 "B" OTSG 1R17 WEAR RESULTS 149.

150 151.

152.

153.

154.

155.

156.

157.

158 159.

160.

161.

162.

163.

164.

165.

166.

167.

168.

169.

170.

171.

172.

173.

174.

175.

176 177.

178.

179.

180.

181.

182.

183.

184.

185.

186.

187.

188.

189.

190.

191.

192.

193.

194.

195.

196.

197.

198.

50 51 51 51 51 52 52 52 52 53 54 54 54 55 55 55 56 56 56 56 57 59 59 59 59 60 60 61 62 62 62 62 63 63 63 63 63 64 65 66 67 67 67 67 68 68 68 68 69 69 119 6

83 119 122 1

95 115 121 122 36 119 122 95 99 122 94 121 122 123 29 37 93 122 122 14 18 1

3 27 71 105 1

26 124 130 130 126 24 117 29 44 105 113 26 31 115 117 21 53 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 11 9

8 9

6 9

5 7

4 3

5 5

6 4

6 6

5 8

5 9

4 6

3 8

8 5

12 13 6

12 13 8

11 3

13 9

7 10 10 7

6 4

5 15 8

15 6

13 7

9 28 osS 14S 04S 14S 04S 1is 03S 07S 15S 04S 09S 14S 14S 06S 09s 14S 07S 08S 15S 14S osS 07S 06S 08S 07S 07S 08S 14S 09S 07S 06S 07S 09S 07S 04S lis lis 09S 04S 08s 07S los 05S 08S lOS 09s 06S 13S 09S 06S

-0.51

-0.72

"+0.53

+0.77

-075

+0.61

+0.75

-0.60

+0.84

-0.72

-0.80

+0.69

-0.72

+0.67

-0.76

-0.85

+0.07

-0.76

+0.77

-0.75

+0.65

-0.63

+0.44

-0.83

-0.35

+0.35

+0.72

-0.68

-0.35

-0.23

-0.01

-0.49

+0.72

+0.60

-0.79

+0.52

-0.48

+0.68

-0.78

+0.42

+0.65

-0.80

+0.69

-0.16

-0.76

+0.65

+0.07

-081

+0.62

+0.26 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40

TABLE 5 ANO-1 "B" OTSG 1R17 WEAR RESULTS 199.

69 110 WAR 8

05S

-069 INSERVICE WEAR <40 200.

69 127 WAR 3

08S

-0.55 INSERVICE WEAR <40 201.

70 18 WAR 9

09S

+068 INSERVICE WEAR <40 202.

70 47 WAR 10 08S

-0.74 INSERVICE WEAR <40 203.

70 47 WAR 4

04S

-0.82 INSERVICE WEAR <40 204.

70 74 WAR 11 O0S

-0.41 INSERVICE WEAR <40 205.

71 31 WAR 4

08S

+069 INSERVICE WEAR <40 206.

71 43 WAR 10 07S

+0.49 INSERVICE WEAR <40 207.

71 44 WAR 5

07S

-0.26 INSERVICE WEAR <40 208.

71 44 WAR 5

07S

+0.52 INSERVICE WEAR <40 209.

71 46 WAR 9

07S

+0.71 INSERVICE WEAR <40 210.

71 127 WAR 13 08S

+0.64 INSERVICE WEAR <40 211.

71 131 WAR 11 08S

+0.61 INSERVICE WEAR <40 212.

72 27 WAR 10 loS

-0.73 INSERVICE WEAR <40 213.

72 31 WAR 13 09S

+068 INSERVICE WEAR <40 214.

72 64 WAR 12 08S

+0.52 INSERVICE WEAR <40 215.

72 64 WAR 2

08S

-0.77 INSERVICE WEAR <40 216.

72 88 WAR 10 06S

+0.38 INSERVICE WEAR <40 217.

72 121 WAR 8

06S

-0.05 INSERVICE WEAR <40 218.

72 130 WAR 9

08S

-0.73 INSERVICE WEAR <40 219.

73 31 WAR 6

los

-0.80 INSERVICE WEAR <40 220.

73 47 WAR 6

09S

+070 INSERVICE WEAR <40 221.

73 57 WAR 14 07S

-0.30 INSERVICE WEAR <40 222.

73 116 WAR 9

08S

-066 INSERVICE WEAR <40 223.

73 126 WAR 8

07S

+0.71 INSERVICE WEAR <40 224.

74 3

WAR 4

13S

-0.41 INSERVICE WEAR <40 225.

74 3

WAR 5

14S

-0.57 INSERVICE WEAR <40 226.

74 47 WAR 9

02S

+0.68 INSERVICE WEAR <40 227.

75 5

WAR 7

14S

+0.62 INSERVICE WEAR <40 228.

75 9

WAR 7

14S

+0.63 INSERVICE WEAR <40 229.

75 9

WAR 5

13S

+0.67 INSERVICE WEAR <40 230.

75 125 WAR 9

13S

-0.67 INSERVICE WEAR <40 231.

75 126 WAR 10 11S

-0.14 INSERVICE WEAR <40 232.

76 119 WAR 6

05S

-0.74 INSERVICE WEAR <40 233.

76 121 WAR 5

04S

-0.70 INSERVICE WEAR <40 234.

77 96 WAR 4

15S

-0.75 INSERVICE WEAR <40 235.

78 24 WAR 8

04S

-0.81 INSERVICE WEAR <40 236.

78 68 WAR 10 07S

+0.66 INSERVICE WEAR <40 237.

79 7

WAR 14 08S

+0.64 INSERVICE WEAR <40 238.

79 9

WAR 4

11S

-0.49 INSERVICE WEAR <40 239.

79 19 WAR 5

10S

-0.75 INSERVICE WEAR <40 240.

79 29 WAR 5

1OS

-0.76 INSERVICE WEAR <40 241.

79 46 WAR 6

09S

-0.24 INSERVICE WEAR <40 242.

79 59 WAR 8

loS +0.33 INSERVICE WEAR <40 243.

79 65 WAR 6

1OS

-0.48 INSERVICE WEAR <40 244.

79 66 WAR 6

O0S

-0.79 INSERVICE WEAR <40 245.

79 112 WAR 6

05S

-0.71 INSERVICE WEAR <40 246.

79 123 WAR 9

08S

-0.37 INSERVICE WEAR <40 247.

80 36 WAR 5

1OS

-0.74 INSERVICE WEAR <40 248.

80 71 WAR 9

08S

+0.68 INSERVICE WEAR <40 29

TABLE 5 ANO-1 "B" OTSG 1R17 WEAR RESULTS 249.

250.

251.

252.

253.

254.

255.

256.

257.

258.

259.

260.

261.

262.

263.

264.

265.

266.

267.

268.

269.

270.

271.

272.

273.

274.

275.

276.

277.

278.

279.

280.

281.

282.

283.

284.

285.

286.

287.

288.

289.

290.

291.

292.

293.

294.

295.

296.

297.

298.

80 80 80 81 81 81 81 81 81 81 82 82 82 83 83 83 83 83 84 84 84 84 84 84 84 85 85 85 85 86 86 87 88 88 88 89 90 90 91 91 91 92 92 93 93 94 94 95 96 97 87 126 130 26 27 27 56 64 80 118 1

116 120 1

21 115 118 130 12 36 45 57 111 122 126 39 69 114 127 84 116 118 50 77 122 18 21 31 30 76 126 72 87 1

29 80 128 117 66 12 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 9

12 4

5 12 6

7 12 6

5 5

10 7

8 4

7 5

6 10 8

9 5

7 8

6 14 9

8 6

5 8

9 6

7 12 9

7 7

4 6

14 6

9 10 7

8 6

4 4

4 30 06S 08S 08S 09S los 05S 07S 07S 06S 06S 07S 08S 08S liS los 08S 02S 08S liS los 08S 06S 06S 08S 04S 06S 05S 04S 07S 05S 08S 04S 06S 06S 14S 08S los 07S 07S 06S 06S 03S 05S 08S 07S 07S 07S 15S 05S 08S

-+-0.44

-0.09

-0.59

-0.75

-0.70

-0.67

-0.19

+0.70

-0.51

+0.28

-0.79

-0.45

-0.39

-0.68

-0.79

+0.59

-0.26

+0.00

-0.71

-0.69

-0.45

-0.72

-039

-0.47

-0.56

+0.17

-0.77

+0.68

-0.56

+0.44

-0.11

-0.66

+0.53

-0.28

-0.02

+0.63

-0.74

-0.35

+0.11

+0.07

-0.77

+0.48

+0.24

+0.74

-0.33

+0.44

-0.72

+0.73

-0.77

-0.59 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40

TABLE 5 ANO-1 "B" OTSG 1R17 WEAR RESULTS 299.

97 44 WAR 7

06S

-0.39 INSERVICE WEAR <40 300.

100 26 WAR 4

07S

+0.50 INSERVICE WEAR <40 301.

100 122 WAR 9

07S

-0 60 INSERVICE WEAR <40 302.

101 68 WAR 10 12S

-0.57 INSERVICE WEAR <40 303.

102 84 WAR 5

05S

-0.78 INSERVICE WEAR <40 304.

103 47 WAR 6

06S

-0.02 INSERVICE WEAR <40 305.

103 58 WAR 8

05S

-0.76 INSERVICE WEAR <40 306.

103 110 WAR 9

08S

-049 INSERVICE WEAR <40 307.

104 13 WAR 5

04S

-0.72 INSERVICE WEAR <40 308.

105 119 WAR 4

14S

-0.78 INSERVICE WEAR <40 309.

106 110 WAR 6

07S

-0.68 INSERVICE WEAR <40 310.

107 37 WAR 12 02S

-0.81 INSERVICE WEAR <40 311.

107 115 WAR 13 14S

-0.64 INSERVICE WEAR <40 312.

108 78 WAR 9

07S

-0.11 INSERVICE WEAR <40 313.

108 106 WAR 6

15S

+0.53 INSERVICE WEAR <40 314.

108 115 WAR 9

09S

+0.52 INSERVICE WEAR <40 315.

109 6

WAR 12 08S

+0.30 INSERVICE WEAR <40 316.

109 114 WAR 12 09S

+0.72 INSERVICE WEAR <40 317.

109 115 WAR 7

09S

+0.55 INSERVICE WEAR <40 318.

110 56 WAR 9

05S

-0.78 INSERVICE WEAR <40 319.

110 108 WAR 7

15S

+0.60 INSERVICE WEAR <40 320.

110 113 WAR 8

09S

+0.70 INSERVICE WEAR <40 321.

110 113 WAR 18 13S

+0.00 INSERVICE WEAR <40 322.

110 115 WAR 9

13S

-0.77 INSERVICE WEAR <40 323.

111 113 WAR 10 09S

+0.68 INSERVICE WEAR <40 324.

112 24 WAR 7

07S

+0.00 INSERVICE WEAR <40 325.

112 84 WAR 9

05S

-0.77 INSERVICE WEAR <40 326.

112 107 WAR 7

04S

-0.89 INSERVICE WEAR <40 327.

112 112 WAR 4

09S

+0.67 INSERVICE WEAR<40 328.

113 29 WAR 7

08S

-0.22 INSERVICE WEAR <40 329.

113 57 WAR 9

05S

-0.84 INSERVICE WEAR <40 330.

113 58 WAR 5

05S

-0.76 INSERVICE WEAR <40 331.

113 111 WAR 4

09S

+0.81 INSERVICE WEAR <40 332.

113 114 WAR 5

09S

+0.70 INSERVICE WEAR <40 333.

114 31 WAR 6

07S

-0.45 INSERVICE WEAR <40 334.

114 102 WAR 13 08S

-0.25 INSERVICE WEAR <40 335.

114 109 WAR 10 09S

+0.24 INSERVICE WEAR <40 336.

114 110 WAR 3

09S

+068 INSERVICE WEAR <40 337.

114 112 WAR 5

09S

+0.71 INSERVICE WEAR <40 338.

115 46 WAR 7

07S

-0.22 INSERVICE WEAR <40 339.

115 56 WAR 6

07S

-0.32 INSERVICE WEAR <40 340.

115 108 WAR 11 09S

+0.68 INSERVICE WEAR <40 341.

116 1

WAR 13 1OS

+0.43 INSERVICE WEAR <40 342.

116 109 WAR 17 13S

-0.71 INSERVICE WEAR <40 343.

116 109 WAR 8

12S

-0.70 INSERVICE WEAR <40 344.

116 109 WAR 7

09S

+0.68 INSERVICE WEAR <40 345.

117 78 WAR 8

06S

-0.81 INSERVICE WEAR <40 346.

117 104 WAR 4

09S

+0.69 INSERVICE WEAR <40 347.

117 105 WAR 9

13S

-0.77 INSERVICE WEAR <40 348.

117 106 WAR 3

13S

-0.74 INSERVICE WEAR <40 31

TABLE 5 ANO-1 "B" OTSG 1R17 WEAR RESULTS 349.

350.

351.

352.

353.

354.

355.

356.

357.

358 359.

360.

361.

362.

363.

364.

365.

366.

367.

368.

369.

370.

371.

372.

373.

374.

375.

376.

377.

378.

379.

380.

381.

382.

383.

384 385.

386.

387.

388.

389.

390.

391.

392.

393.

394.

395.

396.

397.

398.

118 118 119 119 119 119 121 121 121 121 122 122 123 124 124 125 125 126 126 126 127 127 127 127 127 128 128 129 129 129 130 130 130 131 131 131 132 132 132 133 133 133 134 134 136 137 137 138 138 138 27 27 69 93 106

.108 39 41 95 99 29 39 81 11 93 96 97 21 95 96 56 73 91 94 95 1

27 47 48 61 2

9 28 7

43 86 1

26 27 3

26 26 2

3 4

3 78 28 53 67 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 13 6

11 7

14 6

15 11 8

9 12 10 13 15 6

5 5

6 5

5 7

8 12 5

3 5

16 7

8 7

7 8

7 5

6 10 6

7 6

6 6

5 4

6 8

6 7

6 8

9 32 08S 02S 06S 08S 09S 07S 06S 15S 05S 06S 04S 07S 08S 08S 07S 09S 09S 07S 09S 09S 08S 08S 06S 09S 09S liS 08S 06S 06S 05S los 02S 07S 06S 05S 08S 10S 02S 06S los 05S 06S los los los 09S 08S 06S 04S 09S

+0.46

-0.76

-0.70

-0.02

+0.63

-079

-0.77

-0.81

+0.33

-0.79

-0.79

-0.53

-0.55

+0.66

+0.31

+0.74

+0.70

-0.40

+0.72

+068

+0.04

-0.35

-0.75

+0.76

+0.62

-0.65

+0.59

-0.75

-0.69

-0.83

+0.63

-0.76

+0.62

-0.83

-0.80

-0.16

+0.67

-0.75

-083

-0.73

-0.77

-0.71

+0.70

+0.65

+0.61

+0.75

+0.73

-0.72

+0.40

-0.43 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40 WEAR <40

TABLE 5 ANO-1 "B" OTSG 1R17 WEAR RESULTS 399.

139 4

WAR 7

06S

-0.78 INSERVICE WEAR <40 400.

141 9

WAR 7

06S

-0.48 INSERVICE WEAR <40 401.

142 3

WAR 8

los

+0.59 INSERVICE WEAR <40 402.

142 3

WAR 12 09S

+0.63 INSERVICE WEAR <40 403.

142 55 WAR 6

08S

-0.04 INSERVICE WEAR <40 404.

143 1

WAR 9

08S

-0.78 INSERVICE WEAR <40 405.

143 23 WAR 9

13S

-0.68 INSERVICE WEAR <40 406.

144 1

WAR 6

1OS

+0.55 INSERVICE WEAR <40 407.

144 9

WAR 9

07S

-0.46 INSERVICE WEAR <40 408.

144 23 WAR 8

06S

-0.68 INSERVICE WEAR <40 409.

145 11 WAR 4

08S

+0.60 INSERVICE WEAR <40 410.

145 25 WAR 12 12S

-0.67 INSERVICE WEAR <40 411.

146 8

WAR 7

08S

+0.66 INSERVICE WEAR <40 412.

146 10 WAR 12 08S

-075 INSERVICE WEAR <40 413.

146 13 WAR 6

06S

-0.73 INSERVICE WEAR <40 414.

146 16 WAR 10 1IS

-0.77 INSERVICE WEAR <40 415.

146 21 WAR 4

11S

-079 INSERVICE WEAR <40 416.

146 34 WAR 6

14S

-0.76 INSERVICE WEAR <40 417.

146 35 WAR 10 13S

+0.61 INSERVICE WEAR <40 418.

146 45 WAR 10 09S

-0.04 INSERVICE WEAR <40 419.

147 1

WAR 5

08S

+0.69 INSERVICE WEAR <40 420.

147 2

WAR 9

08S

+0.64 INSERVICE WEAR <40 421.

147 3

WAR 8

06S

-0.78 INSERVICE WEAR <40 422.

147 15 WAR 4

08S

+0.39 INSERVICE WEAR <40 423.

147 15 WAR 17 13S

-0.65 INSERVICE WEAR <40 424.

147 27 WAR 8

09S

+0.66 INSERVICE WEAR <40 425.

147 41 WAR 5

06S

-0.83 INSERVICE WEAR <40 426.

147 44 WAR 12 07S

+0.04 INSERVICE WEAR <40 427.

148 7

WAR 6

06S

-0.79 INSERVICE WEAR <40 428.

148 7

WAR 9

08S

+0.68 INSERVICE WEAR <40 429.

148 18 WAR 10 11S

-0.76 INSERVICE, WEAR <40 430.

149 1

WAR 12 08S

+0.63 INSERVICE WEAR <40 431.

149 1

WAR 6

06S

-078 INSERVICE WEAR <40 432.

149 3

WAR 11 06S

-075 INSERVICE WEAR <40 433.

149 14 WAR 7

1OS

+0.71 INSERVICE WEAR <40 434.

149 16 WAR 9

10S

+0.69 INSERVICE WEAR <40 435.

149 19 WAR 7

loS

+0.68 INSERVICE WEAR <40 436 149 19 WAR 8

09S

+0.59 INSERVICE WEAR <40 437.

149 20 WAR 4

1OS

+0.69 INSERVICE WEAR <40 438.

150 8

WAR 8

loS

+0.66 INSERVICE WEAR <40 439.

150 14 WAR 8

11S

-0.72 INSERVICE WEAR <40 440.

150 16 WAR 10 IS

-0.72 INSERVICE WEAR <40 441.

150 16 WAR 11 0OS

+0.61 INSERVICE WEAR <40 442.

150 17 WAR 9

loS

+0.70 INSERVICE WEAR <40 443.

150 20 WAR 7

lOS

+066 INSERVICE WEAR <40 444.

150 23 WAR 9

lOS

+0.73 INSERVICE WEAR <40 445.

151 1

WAR 6

06S

-0.79 INSERVICE WEAR <40 446.

151 8

WAR 7

lOS

+0.68 INSERVICE WEAR <40 447.

151 12 WAR 6

09S

-0.82 INSERVICE WEAR <40 448.

151 14 WAR 7

1OS

+0.70 INSERVICE WEAR <40 33

TABLE 6 ANO-1 "A" OTSG 1R17 ODIGA ARC RESULTS ROW TUBE IND

%TW LOCATION STATUS REPAIR

1.

4 36 VOL UTS

+9.41 INSERVICE ARC IGA

2.

8 39 VOL UTS

+7.12 INSERVICE ARC IGA

3.

9 10 VOL UTS

+6.77 INSERVICE ARC IGA

4.

9 23 VOL UTS

+5.43 INSERVICE ARC IGA

5.

9 32 VOL UTS

+6.70 INSERVICE ARC IGA

6.

10 22 VOL UTS

+11.52 INSERVICE ARC IGA

7.

10 35 VOL UTS

+6.33 INSERVICE ARC IGA 8

11 30 VOL UTS

+839 INSERVICE ARC IGA

9.

12 24 VOL UTS

+6.91 INSERVICE ARC IGA

10.

13 15 VOL UTS

+8.06 INSERVICE ARC IGA

11.

13 25 VOL UTS

+7.39 INSERVICE ARC IGA

12.

15 37 VOL UTS

+8.03 INSERVICE ARC IGA

13.

17 44 VOL UTE

-4.26 INSERVICE ARC IGA

14.

19 53 VOL UTS

+6.47 INSERVICE ARC IGA

15.

21 49 VOL UTS

+6.58 INSERVICE ARC IGA

16.

23 42 VOL UTS

+16.58 INSERVICE ARC IGA

17.

23 53 VOL UTS

+6.43 INSERVICE ARC IGA 18 23 56 VOL UTS

+6.04 INSERVICE ARC IGA

19.

24 16 VOL UTS

+10.14 INSERVICE ARC IGA

20.

24 62 VOL UTS

+8.56 INSERVICE ARC IGA

21.

25 82 VOL UTS

+5.92 INSERVICE ARC IGA

22.

26 52 VOL UTS

+8.08 INSERVICE ARC IGA

23.

26 55 VOL UTS

+8.18 INSERVICE ARC IGA

24.

27 27 VOL UTS

+5.19 INSERVICE ARC IGA

25.

27 27 VOL UTS

+4.85 INSERVICE ARC IGA

26.

28 2

VOL UTS

+10.03 INSERVICE ARC IGA

27.

28 8

VOL UTE

-5.97 INSERVICE ARC IGA 28 29 5

VOL UTS

+6.56 INSERVICE ARC IGA

29.

29 53 VOL UTS

+4.04 INSERVICE ARC IGA

30.

30 88 VOL UTE

-10.43 INSERVICE ARC IGA

31.

30 104 VOL UTS

+12.53 INSERVICE ARC IGA

32.

31 23 VOL UTE

-11.51 INSERVICE ARCIGA

33.

31 106 VOL UTS

+12.87 INSERVICE ARC IGA

34.

32 94 VOL UTS

+8.33 INSERVICE ARC IGA

35.

32 94 VOL UTS

+8.66 INSERVICE ARC IGA

36.

33 105 VOL UTS

+11.61 INSERVICE ARC IGA

37.

34 13 VOL UTS

+8.69 INSERVICE ARC IGA

38.

36 24 VOL UTS

+9.39 INSERVICE ARC IGA

39.

37 12 VOL UTS

+5.60 INSERVICE ARC IGA

40.

37 13 VOL UTS

+9.08 INSERVICE ARC IGA

41.

37 110 VOL UTS

+13.17 INSERVICE ARC IGA

42.

37 111 VOL UTS

+11.58 INSERVICE ARC IGA

43.

37 113 VOL UTS

+8.96 INSERVICE ARC IGA

44.

38 5

VOL UTE

-11.28 INSERVICE ARC IGA

45.

38 10 VOL UTS

+4.15 INSERVICE ARC IGA

46.

38 15 VOL UTS

+8.30 INSERVICE ARC IGA

47.

38 104 VOL UTS

+7.95 INSERVICE ARC IGA

48.

39 47 VOL UTS

+603 INSERVICE ARC IGA 34

49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
88.
89.
90.
91.
92.
93.
94.
95.
96.
97.

98.

40 40 40 41 41 41 41 43 43 43 43 44 46 46 46 46 46 47 48 48 48 48 49 50 51 51 52 52 53 53 54 55 55 55 55 55 55 55 55 56 56 56 56 56 57 57 58 58 58 59 35 13 36 100 3

7 7

15 11 105 107 108 33 110 110 117 118 118 121 21 24 117 119 16 119 21 119 115 125 68 97 18 5

12 62 62 123 123 124 124 3

3 23 125 127 12 123 26 26 121 5

TABLE 6 ANO-1 "A" OTSG 1R17 ODIGA ARC RESULTS VOL UTS

+6.13 VOL UTS

+5.17 VOL UTS

+6.15 VOL UTE

-9.80 VOL UTE

-1.83 VOL UTE

-1.79 VOL UTS

+11.72 VOL UTS

+6.53 VOL UTS

+12.77 VOL UTS

+9.57 VOL UTS

+10 90 VOL UTS

+5.08 VOL UTS

+7.78 VOL UTS

+7.41 VOL UTS

+7.37 VOL UTS

+6.74 VOL UTS

+8.68 VOL UTS

+9.84 VOL UTS

+2.71 VOL UTS

+5.46 VOL UTS

+6.76 VOL UTS

+7.94 VOL UTS

+1020 VOL UTS

+8.37 VOL UTS

+11.68 VOL UTS

+9.33 VOL UTS

+5.15 VOL UTS

+8.06 VOL UTS

+1064 VOL UTS

+5.47 VOL UTS

+8.16 VOL UTE

-2.35 VOL UTE

-8.20 VOL UTS

+9.12 VOL UTS

+7.41 VOL UTS

+11.77 VOL UTS

+8.77 VOL UTS

+7.01 VOL UTS

+10 10 VOL UTS

+6.58 VOL UTS

+9.22 VOL UTS

+11.30 VOL UTS

+8.61 VOL UTS

+8.72 VOL UTS

+6.04 VOL UTS

+8.68 VOL UTS

+8.23 VOL UTS

+11.79 VOL UTS

+6.44 VOL UTE

-4.32 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA

99.

100.

101.

102.

103.

104.

105.

106.

107.

108.

109.

110.

111.

112.

113.

114.

115.

116.

117.

118.

119.

120.

121.

122.

123.

124.

125.

126.

127.

128.

129.

130.

131.

132.

133.

134.

135.

136 137.

138.

139.

140.

141.

142.

143.

144.

145.

146.

147.

148.

59 59 59 59 60 60 60 60 60 61 61 61 62 63 63 63 64 64 64 64 65 65 65 65 65 65 65 65 65 66 66 66 66 66 66 66 67 67 67 67 68 68 68 68 68 68 68 69 69 69 36 8

9 17 113 2

27 121 121 121 14 28 111 99 5

61 123 22 53 60 81 6

47 47 47 56 56 63 120 124 12 12 43 53 123 127 127 10 10 62 120 8

16 17 17 36 59 130 16 20 22 TABLE 6 ANO-1 "A" OTSG 1R17 ODIGA ARC RESULTS VOL UTS

+11.64 VOL UTS

+10.38 VOL UTS

+9.36 VOL UTE

-11.52 VOL UTS

+7.39 VOL UTS

+6.41 VOL UTS

+9.23 VOL UTS

+9.56 VOL UTS

+9.86 VOL UTS

+4.42 VOL UTS

+6.45 VOL UTS

+4.30 VOL UTS

+3.90 VOL UTE

-1.94 VOL UTS

+19.46 VOL UTS

+6.22 VOL UTS

+4.46 VOL UTS

+10.28 VOL UTS

+18.97 VOL UTS

+21.20 VOL UTE

-225 VOL UTS

+5.27 VOL UTS

+8.64 VOL UTS

+662 VOL UTS

+13.48 VOL UTS

+11.71 VOL UTS

+17.13 VOL UTS

+9.53 VOL UTS

+4.61 VOL UTE

-6.67 VOL UTS

+6.44 VOL UTS

+10.09 VOL UTS

+16 52 VOL UTS

+8.31 VOL UTS

+5.72 VOL UTS

+7.34 VOL UTS

+10.80 VOL UTS

+13.38 VOL UTS

+8.63 VOL UTS

+4.97 VOL UTS

+10.49 VOL UTS

+12.07 VOL UTS

+7.96 VOL UTS

+12.38 VOL UTS

+12.53 VOL UTS

+5.72 VOL UTS

+5.99 VOL UTS

+2.88 VOL UTE

-10.59 VOL UTS

+7.40 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA

149.

150.

151.

152.

153.

154.

155.

156.

157.

158.

159.

160.

161.

162.

163.

164.

165.

166.

167.

168.

169.

170.

171.

172.

173.

174.

175.

176.

177.

178.

179.

180.

181.

182.

183.

184.

185.

186.

187.

188.

189.

190.

191.

192.

193.

194.

195.

196.

197.

198.

69 69 69 69 69 69 69 70 70 70 70 70 71 71 72 72 72 73 73 74 74 76 78 79 79 80 80 80 81 81 81 81 82 82 82 82 82 82 82 82 82 83 83 83 83 83 83 83 83 84 37 30 39 39 74 117 124 127 11 19 61 65 120 32 45 47 56 106 40 65 47 85 78 34 65 123 34 62 64 25 56 56 57 23 27 32 34 37 50 55 55 64 20 50 51 51 51 114 114 130 35 TABLE 6 ANO-1 "A" OTSG 1R17 ODIGA ARC RESULTS VOL UTS

+11.54 VOL UTE

-10.32 VOL UTE

-13.34 VOL UTS

+18.65 VOL UTS

+6.31 VOL UTS

+7.11 VOL UTS

+6.80 VOL UTS

+15.06 VOL UTS

+16.10 VOL UTS

+17.98 VOL UTS

+14.85 VOL UTS

+9.68 VOL UTS

+7.14 VOL UTS

+7.05 VOL UTS

+1.61 VOL UTS

+4.80 VOL UTE

-10.70 VOL UTS

+5.01 VOL UTS

+16.69 VOL UTS

+1.64 VOL USR

-1.22 VOL UTE

-4.18 VOL UTS

+6.31 VOL UTS

+14.79 VOL UTS

+7.30 VOL UTS

+5.92 VOL UTS

+15.81 VOL UTS

+21.05 VOL UTS

+18.20 VOL UTS

+10.65 VOL UTS

+15.99 VOL UTS

+8.69 VOL UTS

+16.43 VOL UTS

+6.90 VOL UTS

+5.81 VOL UTS

+8.52 VOL UTS

+12.04 VOL UTS

+10.85 VOL UTS

+14.03 VOL UTS

+11.10 VOL UTS

+15.87 VOL UTS

+3.33 VOL UTS

+21.18 VOL UTS

+16.38 VOL UTS

+18.35 VOL UTS

+11.03 VOL UTS

+5.90 VOL UTS

+6.41 VOL UTS

+6.72 VOL UTS

+12.44 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 1NSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA

199.

200.

201.

202.

203.

204.

205.

206.

207.

208.

209.

210.

211.

212.

213.

214.

215.

216.

217.

218.

219.

220.

221.

222.

223.

224.

225.

226.

227.

228.

229.

230.

231.

232.

233.

234.

235.

236 237.

238.

239.

240.

241.

242.

243.

244.

245.

246.

247.

248.

84 84 85 85 85 85 85 85 86 86 86 86 86 86 86 86 86 86 87 87 88 88 88 90 92 92 92 94 94 94 95 95 96 96 96 97 97 98 99 99 100 101 101 102 102 102 102 102 103 104 38 45 109 26 43 43 53 53 53 16 32 34 74 75 113 113 121 130 130 6

12 59 117 117 17 109 119 127 5

58 121 30 126 7

54 54 109 119 6

120 121 110 112 121 2

2 14 66 112 8

14 TABLE 6 ANO-1 "A" OTSG 1R17 ODIGA ARC RESULTS VOL UTS

+15.22 VOL UTE

-7.73 VOL UTS

+8.10 VOL UTS

+19.11 VOL UTS

+21.45 VOL UTS

+17.46 VOL UTS

+17.87 VOL UTS

+17.11 VOL UTS

+5.45 VOL UTS

+12.34 VOL UTS

+8.58 VOL UTS

+5.32 VOL UTS

+4.74 VOL UTE

-3.51 VOL UTE

-5.02 VOL UTS

+12.44 VOL UTS

+8.36 VOL UTS

+3.68 VOL UTE

-2.42 VOL UTS

+6.13 VOL UTS

+15.16 VOL UTS

+19.69 VOL UTS

+5.07 VOL UTS

+8.34 VOL UTS

+4.42 VOL UTS

+7.07 VOL UTS

+6.50 VOL UTS

+12.90 VOL UTS

+19.42 VOL UTS

+6.09 VOL UTS

+12.95 VOL UTS

+5.25 VOL UTS

+10.15 VOL UTS

+19.83 VOL UTS

+12.04 VOL UTS

+3.13 VOL UTS

+3.90 VOL UTS

+6.37 VOL UTE

-12.05 VOL UTS

+10.69 VOL UTS

+4.38 VOL UTS

+9.72 VOL UTE

-11.83 VOL UTS

+11.43 VOL UTS

+12.81 VOL UTS

+10.00 VOL UTE

-3.23 VOL UTS

+12.11 VOL UTS

+1082 VOL UTS

+8.51 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA

249.

250.

251.

252.

253.

254.

255.

256.

257.

258 259.

260.

261.

262.

263.

264.

265.

266.

267.

268.

269.

270.

271.

272.

273.

274.

275.

276.

277.

278.

279.

280.

281.

282.

283.

284.

285.

286.

287.

288.

289.

290.

291.

292.

293.

294.

295.

296.

297.

298.

105 105 105 105 105 108 111 111 112 114 114 114 114 114 114 115 115 115 115 116 116 116 116 116 116 117 117 117 118 118 118 119 119 120 120 120 120 120 121 122 123 124 125 125 125 125 126 126 126 127 39 3

3 9

112 112 99 107 109 108 2

2 10 44 94 113 2

25 108 113 72 85 98 104 106 112 16 66 99 15 42 100 3

105 92 99 105 106 106 72 104 100 12 90 96 96 98 96 99 99 27 TABLE 6 ANO-1 "A" OTSG 1R17 ODIGA ARC RESULTS VOL UTS

+14.73 VOL UTS

+9.24 VOL UTS

+6.14 VOL UTS

+8.51 VOL UTS

+8.24 VOL UTS

+4.33 VOL UTS

+6.78 VOL UTS

+5.10 VOL UTS

+7.79 VOL UTS

+3.92 VOL UTS

+8.34 VOL UTS

+4.76 VOL UTS

+6.20 VOL UTS

+3.63 VOL UTS

+10.76 VOL UTE

-11.57 VOL UTS

+3.93 VOL UTS

+10.78 VOL UTS

+9.34 VOL UTE

-9.17 VOL UTS

+4.29 VOL UTE

-6.33 VOL UTS

+5.06 VOL UTS

+7.31 VOL UTS

+8.67 VOL UTS

+6.30 VOL UTE

-6.56 VOL UTS

+3.89 VOL UTS

+12.55 VOL UTS

+7.55 VOL UTS

+6.58 VOL UTS

+840 VOL UTS

+5.16 VOL UTS

+6.56 VOL UTS

+7.88 VOL UTS

+5.25 VOL UTS

+3.80 VOL UTS

+4.90 VOL UTE

-9.65 VOL UTS

+3.99 VOL UTS

+7.01 VOL UTS

+12.47 VOL UTS

+11.73 VOL UTS

+10.13 VOL UTS

+11.74 VOL UTS

+10.50 VOL UTS

+8.90 VOL UTS

+7.48 VOL UTS

+8.46 VOL UTS

+3.80 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA

299.

300.

301.

302.

303.

304.

305.

306.

307.

308.

309.

310.

311.

312.

313.

314.

315.

316.

317.

318.

319.

320.

321.

322.

323.

324.

325.

326.

327.

328.

329.

330.

331.

332.

333.

334.

335.

127 127 129 132 132 134 134 134 136 136 136 137 137 137 137 138 138 138 138 139 139 139 140 140 142 142 142 143 143 143 143 143 145 146 146 147 148 40 34 67 91 29 80 3

31 37 2

33 76 3

12 29 51 25 31 40 72 31 51 52 29 29 28 49 49 19 19 19 38 52 24 28 48 37 6

TABLE 6 ANO-1 "A" OTSG 1R17 ODIGA ARC RESULTS VOL UTS

+5.07 VOL UTE

-6.90 VOL UTS

+8.54 VOL UTS

+7.36 VOL UTS

+10.91 VOL UTS

+7.72 VOL UTS

+9.82 VOL UTE

-10.53 VOL UTS

+692 VOL UTS

+12.22 VOL UTS

+12.32 VOL UTS

+682 VOL UTS

+6.93 VOL UTS

+8.90 VOL UTS

+5.54 VOL UTS

+11.43 VOL UTS

+5.37 VOL UTS

+9.90 VOL UTS

+7.03 VOL UTS

+6.14 VOL UTS

+8.40 VOL UTS

+6.30 VOL UTS

+5.68 VOL UTS

+5.27 VOL UTS

+3.92 VOL UTS

+655 VOL UTS

+7.33 VOL UTS

+3.25 VOL UTS

+3.90 VOL UTS

+4.40 VOL UTS

+10.59 VOL UTS

+5.66 VOL UTS

+7.31 VOL UTS

+10.90 VOL UTS

+7.73 VOL UTE

-10.44 VOL UTS

+7.63 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA

TABLE 7 ANO-1 "B" OTSG 1R17 ODIGA ARC RESULTS ROW TUBE IND

%TW LOCATION

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.

38

39.
40.
41.
42.
43.
44.
45.
46.
47.

48.

7 22 25 26 29 40 48 50 52 52 53 53 53 54 54 54 55 55 55 58 59 60 60 60 62 63 63 64 64 65 65 68 68 68 69 69 69 69 69 70 70 70 71 71 71 71 71 71 STATUS 6

90 58 18 102 85 7

1 102 122 3

3 5

2 2

106 3

8 8

41 115 9

96 113 4

6 6

6 8

11 11 15 15 23 11 25 40 41 51 19 27 27 15 15 15 18 28 28 41 VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL "VOL VOL VOL VOL VOL VOL UTS UTS UTE UTS UTS UTE IJTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS PLG UTS PLG UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS

+681

+6.26

-2.12

+6.28

+6.17

-2.25

+460

+9.91

+3.09

+3.27

+7.00

+8.00

+5.94

+4.09

+4.37

+4.45

+6.95

+7.14

+6.80

+4.48

+9.20

+4.42

+5.27

+4.51

+5.98

+5.14

+5.57

+6.79

+5.95

+3.04

+4.05

+4.90

+3.27

+7.31

+5.05

+9.36

+5.36

+4.98

+8.13

+3.31

+3.52

+5.37

+4.76

+5.42

+6.89

+5.35

+3.47

+6.32 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE REPAIR ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA

49.

50

51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.

62

63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
88.
89.
90.
91.
92.
93.
94.
95.
96.
97.

98.

71 72 72 72 72 72 72 72 72 72 73 73 73 73 73 73 73 73 73 73 74 74 74 75 75 75 77 78 78 78 78 79 79 79 79 79 79 79 80 80 80 80 80 80 80 80 80 80 80 80 42 50 14 14 14 16 23 24 24 27 56 18 25 51 65 65 65 65 93 93 93 58 58 58 37 44 48 66 44 58 63 68 24 24 32 33 35 53 57 13 13 13 22 22 22 22 28 28 31 53 101 TABLE 7 ANO-1 "B" OTSG 1R17 ODIGA ARC RESULTS VOL UTE

-12.35 VOL UTS

+2.86 VOL UTS

+3.31 VOL UTS

+4.32 VOL UTS

+4.77 VOL UTS

+4.51 VOL UTS

+3.85 VOL UTS

+6.26 VOL UTS

+4.53 VOL UTS

+5.51 VOL UTS

+4.00 VOL UTS

+4.77 VOL UTS

+7.56 VOL UTS

+3.10 VOL UTS

+4.31 VOL UTS

+7.18 VOL UTS

+7.89 VOL UTE

-3.23 VOL UTE

-3.97 VOL UTE

-3.70 VOL UTS

+4.81 VOL UTS

+6.33 VOL UTS

+3.59 VOL UTS

+4.86 VOL UTS

+5.47 VOL UTS

+4.87 VOL UTS

+4.24 VOL UTS

+4.10 VOL UTS

+3.61 VOL UTS

+6.00 VOL UTS

+5.33 VOL UTE

-5.86 VOL UTE

-5.06 VOL UTS

+4.99 VOL UTS

+5.39 VOL UTS

+4.09 VOL UTS

+6.30 VOL UTS

+645 VOL UTS

+3.05 VOL UTS

+4.77 VOL UTS

+4.09 VOL UTS

+4.03 VOL UTS

+3.96 VOL UTS

+4.77 VOL UTS

+5.18 VOL UTS

+4.24 VOL UTS

+8.02 VOL UTS

+3.98 VOL UTS

+1183 VOL UTE

-3.72 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA

99.

100.

101.

102.

103.

104.

105.

106.

107.

108.

109.

110.

111.

112.

113.

114.

115.

116.

117.

118.

119.

120.

121.

122.

123.

124.

125.

126.

127.

128.

129.

130.

131.

132.

133.

134.

135.

136.

137.

138 139.

140.

141.

142.

143.

144.

145.

146.

147.

148.

80 81 81 82 82 82 82 83 83 83 83 83 83 84 84 84 84 84 84 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 86 86 86 87 87 87 87 87 88 89 89 89 43 101 36 37 26 45 56 58 14 14 14 14 14 38 12 15 20 20 30 30 14 16 16 18 18 18 19 19 19 19 21 21 21 21 25 25 45 45 56 25 25 29 11 25 25 25 61 15 10 110 110 TABLE 7 ANO-1 "B" OTSG 1R17 ODIGA ARC RESULTS VOL UTE

-2.34 VOL UTS

+7.85 VOL UTS

+7.03 VOL UTS

+3.40 VOL UTS

+7.16 VOL UTS

+9.41 VOL UTS

+8.52 VOL UTS

+13.73 VOL UTS

+4.83 VOL UTS

+7.23 VOL UTS

+11.23 VOL UTS

+10.55 VOL UTS

+7.42 VOL UTS

+8.92 VOL UTS

+949 VOL UTE

-5.07 VOL UTE

-365 VOL UTS

+4.75 VOL UTS

+5.82 VOL PLG IUTS

+3.46 VOL UTS

+3.12 VOL UTS

+3.60 VOL UTS

+2.77 VOL UTS

+3.64 VOL UTS

+5.25 VOL UTE

-2.83 VOL UTE

-6.56 VOL UTE

-7.73 VOL UTE

-8.36 VOL UTS

+4.30 VOL UTS

+5.55 VOL UTS

+6.91 VOL UTS

+11.44 VOL UTS

+5.97 VOL UTS

+7.40 VOL UTS

+6.22 VOL UTS

+8.14 VOL UTS

+562 VOL UTS

+4.52 VOL UTS

+6.50 VOL UTS

+5.38 VOL UTS

+5.03 VOL UTS

+5.19 VOL UTS

+7.55 VOL UTS

+8.26 VOL UTS

+4.38 VOL UTS

+12.24 VOL UTS

+5.95 VOL UTE

-409 VOL UTE

-3.11 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA

149.

150.

151.

152.

153.

154.

155.

156 157.

158.

159.

160.

161.

162.

163.

164.

165.

166.

167.

168.

169.

170.

171.

172.

173.

174.

175.

176.

177.

178.

179.

180.

181.

182.

183.

184.

185.

186.

187.

188.

189.

190.

191.

192.

193.

194.

195.

196.

197.

198.

89 92 93 93 93 96 96 96 96 96 96 97 98 98 100 100 100 100 101 101 101 101 101 101 102 102 102 103 103 103 103 104 104 106 106 106 107 107 109 110 110 110 110 111 114 116 116 117 117 117 44 110 10 5

5 5

1 1

14 14 18 34 23 9

9 2

2 5

11 3

3 10 10 10 10 9

9 9

15 18 19 22 2

2 17 17 74 9

73 117 2

2 3

3 115 91 2

13 3

4 4

TABLE 7 ANO-1 "B" OTSG 1R17 ODIGA ARC RESULTS VOL UTE

-2.59 VOL UTS

+4.54 VOL UTS

+4.83 VOL UTS

+5.72 VOL UTS

+7.86 VOL UTS

+4.64 VOL UTS

+5.12 VOL UTS

+5.40 VOL UTS

+4.53 VOL UTS

+5.89 VOL UTS

+4.12 VOL UTS

+563 VOL UTS

+5.84 VOL UTS

+6.34 VOL UTS

+4.25 VOL UTS

+4.79 VOL UTS

+6.90 VOL UTS

+6.73 VOL UTS

+4.02 VOL UTS

+6.19 VOL UTS

+6.61 VOL UTS

+7.56 VOL UTS

+5.39 VOL UTS

+6.60 VOL UTS

+3.28 VOL UTS

+5.17 VOL UTS

+5.54 VOL UTS

+4.13 VOL UTS

+3.95 VOL UTS

+4.90 VOL UTS

+6.58 VOL UTS

+4.06 VOL UTS

+5.20 VOL UTS

+5.48 VOL UTS

+5.77 VOL UTS

+20.84 VOL UTS

+3.41 VOL UTE

-2.78 VOL UTS

+7.13 VOL UTS

+4.18 VOL UTS

+6.16 VOL UTS

+3.10 VOL UTS

+6.11 VOL UTS

+5.36 VOL UTS

+3.43 VOL UTS

+7.24 VOL UTS

+4.99 VOL PLG UTS

+501 VOL PLG UTS

+3.69 VOL PLG UTS

+5.32 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA

199.

200.

201.

202.

203.

204.

205.

206.

207.

208.

209.

210.

211.

212.

213.

214.

215.

216.

217.

218.

219.

220.

221.

222.

223.

224.

225.

226.

45 117 117 118 118 118 118 119 119 121 122 123 125 126 131 131 131 134 137 137 141 141 144 145 145 146 149 150 150 4

5 3

3 3

34 4

4 4

1 8

5 8

6 7

7 11 6

22 20 20 18 11 11 38 13 18 18 TABLE 7 ANO-1 "B" OTSG 1R17 ODIGA ARC RESULTS VOL PLG UTS

+5.78 VOL UTS

+4.76 VOL UTS

+4.42 VOL UTS

+5.13 VOL UTS

+5.69 VOL UTS

+2.49 VOL UTS

+3.95 VOL UTS

+4.97 VOL UTS

+4.50 VOL UTS

+3.03 VOL UTS

+8.34 VOL UTS

+7.45 VOL UTS

+4.00 VOL UTS

+1.08 VOL UTS

+4.09 VOL UTS

+4.96 VOL UTS

+2.53 VOL UTS

+6.19 VOL UTS

+4.07 VOL UTS

+5.16 VOL UTS

+3.85 VOL UTS

+5.14 VOL UTS

+5.66 VOL UTS

+6.16 VOL UTS

+4.56 VOL UTS

+4.47 VOL UTS

+5.96 VOL UTS

+6.89 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA ARC IGA

TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS ROW TUBE INm

%TW LOCATION STATUS REPAIR

1.

3 12 SAA UTE

-0.19 INSERVICE ARC TEC

2.

3 16 SAA UTE

-0.20 INSERVICE ARC TEC

3.

4 21 SAA UTE

-0.28 INSERVICE ARC TEC

4.

4 22 SAA UTE

-0.21 INSERVICE ARC TEC

5.

4 27 SAA UTE

-0.30 INSERVICE ARC TEC

6.

4 37 MAA UTE

-028 INSERVICE ARC TEC

7.

5 24 MAA UTE

-0.27 INSERVICE ARC TEC

8.

5 25 MAA UTE

-0.19 INSERVICE ARC TEC

9.

5 26 MAA UTE

-0.26 INSERVICE ARC TEC

10.

5 44 SAA UTE

-0.32 INSERVICE ARC TEC

11.

5 46 SAA UTE

-0.34 INSERVICE ARC TEC

12.

6 21 SAA UTE

-0.17 INSERVICE ARC TEC

13.

6 28 MAA UTE

-0.30 INSERVICE ARC TEC

14.

6 36 MAA UTE

-030 INSERVICE ARC TEC

15.

6 50 SAA UTE

-0.38 INSERVICE ARC TEC

16.

7 6

SAA UTE

-0.16 INSERVICE ARC TEC

17.

7 19 SAA UTE

-0.30 INSERVICE ARC TEC

18.

7 21 MAA UTE

-0.29 INSERVICE ARC TEC

19.

7 22 SAA UTE

-0.25 INSERVICE ARC TEC

20.

7 28 SAA UTE

-0.25 INSERVICE ARC TEC

21.

7 43 MAA UTE

-044 INSERVICE ARC TEC

22.

7 52 MAA UTE

-0.30 INSERVICE ARC TEC

23.

8 6

MAA UTE

-0.23 INSERVICE ARC TEC

24.

8 7

SAA UTE

-0.30 INSERVICE ARC TEC

25.

8 8

SAA UTE

-0.17 INSERVICE ARC TEC

26.

8 12 SAA UTE

-0.17 INSERVICE ARC TEC

27.

8 27 MAA UTE

-0.27 INSERVICE ARC TEC

28.

8 39 MAA UTE

-0.29 INSERVICE ARC TEC

29.

8 44 SAA UTE

-0.24 INSERVICE ARC TEC

30.

8 49 SAA UTE

-0.36 INSERVICE ARC TEC

31.

8 56 SAA UTE

-0.23 INSERVICE ARC TEC

32.

9 9

SAA UTE

-028 INSERVICE ARC TEC

33.

9 10 MAA UTE

-0.22 INSERVICE ARC TEC

34.

9 12 MAA UTE

-0.18 INSERVICE ARC TEC

35.

9 14 MAA UTE

-0.15 INSERVICE ARC TEC

36.

9 15 MAA UTE

-0.41 INSERVICE ARC TEC

37.

9 35 MAA UTE

-0.44 INSERVICE ARC TEC

38.

9 46 SAA UTE

-0.27 INSERVICE ARC TEC

39.

9 56 SAA U13E

-0.24 INSERVICE ARC TEC

40.

10 8

MAA UTE

-0.08 INSERVICE ARC TEC

41.

10 11 SAA UTE

-0.28 INSERVICE ARC TEC

42.

10 15 SAA UTE

-0.18 INSERVICE ARC TEC

43.

10 21 MAA UTE

-0.22 INSERVICE ARC TEC

44.

10 26 MAA UTE

-0.27 INSERVICE ARC TEC

45.

10 30 SAA UTE

-0.17 INSERVICE ARC TEC

46.

10 32 MAA UTE

-0.23 INSERVICE ARC TEC

47.

10 35 MAA UTE

-0.28 INSERVICE ARC TEC

48.

10 47 SAA UTE

-0.25 INSERVICE ARC TEC 46

49.
50.
51.
52.
53.
54.
55.

56

57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
88.
89.
90.
91.
92.
93.
94.
95.
96.
97.

98.

10 10 11 11 11 11 11 11 11 11 11 12 12 12 12 12 12 12 13 13 13 14 14 14 14 14 14 14 14 14 14 14 15 16 16 16 16 16 16 16 16 16 17 17 17 17 17 17 17 18 47 56 58 23 45 49 50 57 59 60 61 63 16 31 32 34 47 60 62 16 27 64 4

6 16 35 39 62 63 65 66 69 72 55 7

8 9

19 22 41 43 44 66 8

11 13 21 54 67 69 5

TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.34 SAA UTE

-0.41 MAA UTE

-0.30 SAA UTE

-0.25 SAA UTE

-0.19 SAA UTE

-0.28 SAA UTE

-0.29 MAA UTE

-0.21 SAA IJTE

-0.18 MAA UTE

-0.23 SAA UTE

-0.34 SAA UTE

-0.26 MAA UTE

-0.14 SAA UTE

-0.30 MAA UTE

-0.14 SAA UTE

-0.21 SAA UTE

-0.28 MAA UTE

-029 MAA UTE

-0.23 SAA UTE

-0.29 MAA UTE

-0.18 SAA UTE

-0.34 MAA UTE

-0.28 SAA UTE

-0.35 SAA UTE

-0.29 SAA UTE

-0.23 MAA UTE

-0.26 SAA UTE

-0.29 MAA UTE

-0.36 MAA UTE

-0.33 SAA UTE

-0.33 MAA UTE

-0.29 SAA UTE

-0.34 SAA UTE

-0.34 MAA UTE

-0.20 SAA UTE

-0.26 SAA UTE

-0.36 SAA UTE

-0.24 SAA UTE

-0.24 SAA UTE

-0.19 MAA UTE

-0.26 MAA UTE

-0.28 SAA UTE

-0.36 SAA UTE

-0.22 SAA UTE

-0.21 MAA UTE

-0.19 MAA UTE

-0.25 MAA UTE

-0.26 MAA UTE

-0.36 MAA UTE

-0.22 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

99.

100.

101.

102.

103.

104.

105 106.

107.

108.

109.

110.

111.

112.

113.

114.

115.

116.

117.

118 119.

120.

121.

122.

123.

124.

125.

126.

127.

128.

129.

130.

131.

132.

133.

134.

135.

136.

137.

138.

139.

140.

141.

142.

143.

144.

145.

146.

147.

148 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 19 19 19 19 19 19 19 19 19 19 19 20 20 20 20 20 20 20 20 20 20 20 20 21 21 21 21 21 21 21 21 21 21 21 48 14 20 26 32 36 38 40 41 49 55 59 67 68 72 78 82 3

6 10 30 31 39 66 68 69 70 75 6

9 10 13 15 28 41 45 49 64 69 73 3

8 9

10 11 12 17 23 26 69 74 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.27 MAA UTE

-0.17 SAA UTE

-0.24 SAA UTE

-0.22 MAA UTE

-0.24 SAA UTE

-0.27 MAA UTE

-0.24 MAA UTE

-0.22 MAA UTE

-0.26 MAA UTE

-0.22 SAA UTE

-0.27 SAA UTE

-0.27 MAA UTE

-0.25 SAA UTE

-0.50 MAA UTE

-0.43 MAA UTE

-0.22 SAA UTE

-0.24 MAA UTE

-0.16 SAA UTE

-0.24 MAA UTE

-0.21 SAA UTE

-0.24 MAA UTE

-0.25 SAA UTE

-0.24 SAA UTE

-0.25 SAA UTE

-0.24 SAA UTE

-029 SAA UTE

-0.34 MAA UTE

-0.26 MAA UTE

-0.26 SAA UTE

-0.34 MAA UTE

-028 SAA UTE

-0.23 MAA UTE

-0.30 MAA UTE

-0.20 SAA UTE

-0.22 MAA UTE

-0.21 MAA UTE

-0.11 SAA UTE

-0.24 SAA UTE

-0.24 SAA UTE

-0.21 SAA IUTE

-0.23 MAA UTE

-0.21 SAA UTE

-0.28 SAA UTE

-0.25 SAA UTE

-0.29 SAA UTE

-0.28 SAA UTE

-0.26 MAA UTE

-0.24 MAA UTE

-0.29 SAA UTE

-0.22 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

149.

22 150.

22 151.

22 152.

22 153.

22 154.

22 155.

22 156.

22 157.

22 158.

22 159.

22 160.

22 161.

22 162.

22 163.

22 164.

22 165.

23 166.

23 167.

23 168.

23 169.

23 170 23 171.

23 172.

23 173.

23 174.

23 175.

23 176.

23 177.

23 178.

24 179.

24 180.

24 181.

24 182.

24 183.

24 184.

24 185.

24 186.

24 187.

24 188 25 189.

25 190.

25 191.

25 192.

25 193.

25 194.

25 195.

25 196.

25 197.

25 198.

25 4

7 8

9 11 12 13 14 18 25 30 41 55 72 74 76 4

12 15 17 18 26 53 54 60 74 75 76 77 6

9 10 28 29 30 31 34 49 89 9

10 12 13 14 16 19 34 73 74 75 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.30 SAA UTE

-0.21 MAA UTE

-0.32 MAA UTE

-0.30 MAA UTE

-0.30 SAA UTE

-0.26 SAA UTE

-0.23 SAA UTE

-0.30 MAA UTE

-0.25 MAA UTE

-0.19 SAA UTE

-0.25 SAA UTE

-0.20 MAA UTE

-0.32 MAA UTE

-0.14 SAA UTE

-0.37 SAA UTE

-0.37 SAA UTE

-0.22 SAA UTE

-0.32 MAA UTE

-0.25 SAA UTE

-025 SAA UTE

-0.29 SAA UTE

-0.25 SAA UTE

-0.16 SAA UTE

-0.21 SAA UTE

-0.21 MAA UTE

-0.39 MAA UTE

-0.20 MAA UTE

-031 MAA UTE

-025 MAA UTE

-0.21 MAA UTE

-0.28 MAA UTE

-0.24 SAA UTE

-0.33 MAA UTE

-0.25 SAA UTE

-0.27 MAA UTE

-0.26 SAA UTE

-0.21 MAA UTE

-024 MAA UTE

-0.42 MAA UTE

-0.26 SAA UTE

-0.35 MAA UTE

-0.28 SAA UTE

-0.18 MAA UTE

-0.27 MAA UTE

-0.26 SAA

=TE

-0.24 MAA UTE

-0.21 MAA UTE

-0.22 SAA UTE

-0.27 MAA UTE

-0.27 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 49 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

199.

200.

201.

202.

203.

204.

205 206.

207.

208.

209.

210.

211.

212.

213.

214.

215.

216.

217.

218.

219.

220.

221.

222.

223.

224.

225.

226.

227.

228.

229.

230.

231.

232.

233.

234.

235.

236.

237.

238.

239.

240.

241.

242.

243.

244.

245.

246.

247.

248 26 26 26 26 26 26 26 26 26 26 26 26 26 27 27 27 27 27 27 27 27 27 27 27 28 28 28 28 28 28 28 28 28 28 28 28 28 29 29 29 29 29 29 29 29 29 29 29 29 29 50 4

8 11 14 15 17 18 50 56 73 79 81 94 3

12 15 17 30 51 76 81 82 83 89 5

8 9

14 15 30 31 32 47 51 74 95 98 4

6 9

11 12 15 16 17 19 31 42 44 52 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.23 MAA UTE

-0.26 SAA UTE

-0.32 MAA UTE

-0.29 SAA UTE

-0.32 MAA UTE

-0.28 SAA UTE

-0.25 MAA UJTE

-0.28 MAA UTE

-0.24 MAA UTE

-0.25 SAA UTE

-0.25 SAA UTE

-0.23 SAA UTE

-0.21 SAA UTE

-028 SAA UTE

-0 17 SAA UTE

-0.24 MAA UTE

-0.29 SAA UTE

-027 SAA UTE

-0.25 SAA UTE

-0.18 SAA UTE

-0.23 MAA UTE

-0.20 SAA UTE

-0.29 MAA UTE

-0.30 MAA UTE

-0.20 SAA UTE

-0.30 SAA UTE

-0.19 SAA UTE

-0.30 SAA UTE

-0.23 MAA UTE

-0.28 SAA UTE

-0.27 MAA UTE

-0.30 SAA UTE

-0.24 MAA UTE

-0.17 MAA UIE

-0.19 MAA UTE

-0.33 MAA UTE

-0.42 MAA 11TE

-0.25 MAA UTE

-0.22 MAA UTE

-0.23 MAA 1TH

-0.35 SAA UTE

-0.20 MAA UTE

-0.35 SAA 11TE

-0.17 MAA UTE

-0.32 SAA UTE

-0.22 SAA UTE

-0.29 SAA UTE

-0.18 SAA LITE

-0.21 MAA UTE

-0.25 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

249.

250.

251.

252.

253.

254.

255.

256.

257.

258.

259.

260.

261.

262.

263.

264.

265.

266.

267.

268.

269.

270.

271.

272.

273.

274.

275.

276.

277.

278.

279.

280.

281.

282.

283.

284.

285.

286.

287.

288.

289.

290.

291.

292.

293.

294.

295.

296.

297.

298.

29 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 31 31 31 31 31 31 32 32 32 32 32 32 32 32 32 32 32 32 33 33 33 33 33 33 33 33 33 51 75 2

3 4

5 8

9 10 13 14 16 20 21 44 49 50 54 55 64 78 80 88 103 3

19 21 34 56 79 3

6 11 34 37 40 55 78 98 101 103 105 4

21 27 35 43 96 98 99 103 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.19 SAA UTE

-0.13 MAA UTE

-0.33 MAA UTE

-0.22 MAA UTE

-0.30 MAA UTE

-0.19 SAA UTE

-025 MAA UTE

-019 SAA UTE

-0.21 MAA UTE

-0.32 SAA UTE

-0.44 SAA UTE

-0 26 MAA UTE

-0.28 SAA UTE

-0 17 SAA UrE

-023 SAA UTE

-0.21 MAA UTE

-0.20 SAA UTE

-0.18 MAA UTE

-0.22 MAA UTE

-019 SAA UTE

-0.19 SAA UTE

-0.26 SAA LTrE

-0.22 SAA UTE

-0.26 SAA UTE

-0.30 MAA UTE

-0.26 SAA UTE

-0.28 MAA UTE

-0.24 MAA UTE

-0.20 MAA UTE

-0.19 MAA UTE

-0.29 MAA UTE

-0.11 SAA UTE

-0.21 SAA UTE

-0.33 SAA UTE

-0.24 SAA UTE

-0.22 SAA UTE

-0.19 SAA IJTE

-0.29 MAA UTE

-0.24 MAA UTE

-0.29 SAA UTE

-026 MAA UTE

-0.17 SAA UTE

-0.28 MAA UTE

-0.25 MAA UTE

-029 MAA UTE

-0.24 MAA UTE

-0.34 SAA UTE

-0.33 MAA UTE

-0.24 MAA UTE

-0.21 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

299.

300.

301.

302.

303.

304.

305.

306.

307.

308.

309.

310.

311.

312.

313.

314.

315.

316.

317.

318.

319.

320.

321.

322.

323.

324.

325.

326.

327.

328.

329.

330.

331.

332.

333.

334.

335.

336.

337.

338.

339.

340.

341.

342.

343.

344.

345.

346.

347.

348.

33 33 34 34 34 34 34 34 34 34 34 34 35 35 35 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 37 37 37 37 37 37 37 37 37 37 38 38 38 38 38 38 38 38 52 105 107 4

8 22 53 65 80 97 102 104 107 8

82 106 2

10 11 17 21 25 28 45 53 60 71 77 81 101 106 108 109 5

10 16 20 51 53 57 103 105 107 8

11 17 20 24 37 39 102 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.26 SAA UTE

-0.29 MAA UTE

-0.22 MAA UTE

-0.29 MAA UTE

-0.24 MAA UTE

-0.21 MAA UTE

-0.24 SAA UTE

-0.22 SAA UTE

-0.47 MAA UTE

-0.28 MAA UTE

-0.29 SAA UTE

-0.30 SAA UTE

-025 SAA ITE

-0.36 MAA UTE

-0.26 SAA UTE

-0.30 MAA UTE

-0.24 MAA UTE

-0.19 SAA UTE

-0.23 SAA UTE

-0.18 SAA UTE

-0.26 MAA UTE

-0.21 MAA UTE

-0.21 SAA UTE

-0.20 SAA UTE

-0.25 SAA UTE

-023 SAA UTE

-0.29 SAA UTE

-0.28 SAA UTE

-0.38 MAA UTE

-0.28 MAA UTE

-0.17 SAA UTE

-0.28 MAA UTE

-0.26 SAA UTE

-0.26 MAA UTE

-0.20 SAA UTE

-0.16 SAA UTE

-0.21 SAA UTE

-0.18 SAA UTE

-0.25 MAA UTE

-0.34 MAA UTE

-0.31 MAA UTE

-0.33 SAA UTE

-0.21 MAA UTE

-0.28 MAA UTE

-0.22 MAA UTE

-0.26 SAA UTE

-0.21 MAA UTE

-0.27 SAA UTE

-0.18 MAA UTE

-0.34 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC

349.

38 350.

38 351.

38 352.

39 353.

39 354.

39 355.

39 356.

39 357.

39 358.

39 359.

39 360.

39 361.

39 362.

39 363.

39 364.

39 365.

40 366.

40 367.

40 368.

40 369.

40 370.

40 371.

40 372.

40 373.

40 374.

40 375.

40 376.

40 377.

40 378 40 379.

40 380.

40 381.

41 382.

41 383.

41 384.

41 385.

41 386.

41 387.

41 388.

41 389.

41 390.

41 391.

41 392.

41 393.

41 394.

41 395.

41 396.

41 397.

41 398.

42 106 110 112 5

6 9

24 44 47 62 63 104 106 107 110 112 4

5 6

9 12 15 21 26 27 38 83 85 99 102 105 115 6

17 19 25 36 39 46 54 58 61 62 63 67 103 105 113 114 8

TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.21 SAA UTE

-0.30 SAA UTE

-039 MAA UTE

-020 MAA UTE

-0.22 SAA IJTE

-0.18 MAA UTE

-0.25 SAA UTE

-0.20 SAA UTE

-0.16 MAA UTE

-0.27 MAA UTE

-0.32 MAA UTE

-0.36 SAA UTE

-0.37 SAA UTE

-0.32 SAA UTE

-0.42 MAA UTE

-0.39 MAA UTE

-0.26 MAA UTE

-0.21 MAA UTE

-0.31 MAA UTE

-0.19 MAA UTE

-0.28 MAA UTE

-0.27 SAA UTE

-0.23 MAA UTE

-0.24 SAA UTE

-0.29 MAA UTE

-0.17 MAA UTE

-0.25 SAA UTE

-0.21 SAA UTE

-0.25 SAA UTE

-0.21 SAA UTE

-0.20 MAA UTE

-026 MAA UTE

-0.10 SAA UTE

-0.17 SAA UTE

-0.19 SAA UTE

-0.22 SAA UTE

-0.20 MAA UTE

-0.24 SAA UTE

-0.21 MAA UTE

-017 MAA UTE

-018 MAA UTE

-0.23 MAA UTE

-0.15 MAA UTE

-0.23 MAA UTE

-0.20 SAA UTE

-0.27 SAA UTE

-0.33 MAA UTE

-035 SAA UTE

-0.27 MAA UTE

-0.31 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 53 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

399.

42 400 42 401.

42 402.

42 403.

42 404.

42 405.

42 406.

42 407.

42 408.

42 409.

42 410 42 411.

42 412.

42 413.

42 414.

43 415.

43 416.

43 417.

43 418.

43 419.

43 420.

43 421.

43 422.

43 423.

43 424.

43 425.

43 426.

43 427.

43 428.

43 429.

43 430.

43 431.

43 432.

44 433.

44 434.

44 435.

44 436 44 437.

44 438.

44 439.

44 440.

44 441.

44 442.

44 443.

44 444.

44 445.

44 446.

44 447.

44 448.

44 22 30 38 42 47 53 54 69 82 88 103 104 111 112 113 6

10 12 23 39 40 51 52 53 63 74 79 82 100 103 105 112 113 8

9 19 22 31 39 54 55 64 68 70 96 99 100 105 106 107 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.25 MAA UTE

-0.16 SAA UTE

-0.18 MAA UTE

-0.16 SAA MTE

-0.15 MAA UTE

-0.22 SAA UTE

-0.20 MAA UTE

-0.17 MAA UTE

-0.22 MAA SAA SAA SAA SAA SAA MAA MAA SAA MAA SAA SAA MAA SAA MAA SAA SAA MAA SAA SAA SAA SAA SAA SAA SAA SAA SAA MAA MAA MAA MAA SAA MAA MAA MAA SAA SAA SAA SAA SAA MAA UTE

-0.26 UTE

-030 UTE

-0.40 UTE

-0.32 UTE

-0.26 UTE

-0.30 UTE

-0.22 UTE

-0.17 UTE

-0.32 UTE

-0.18 UTE

-0.23 UTE

-0.18 UTE

-0.22 UTE

-0.21 UTE

-0.21 UTE

-0.17 UTE

-0.24 UTE

-0.12 UTE

-0.17 UTE

-0.20 UTE

-0.31 UTE

-0.30 UTE

-0.25 UTE

-0.30 UTE

-0.25 UTE

-0.20 UTE

-0.27 UTE

-0.24 UTE

-0.19 UTE

-0.20 UTE

-0.30 UTE

-0.18 UTE

-016 UTE

-0.21 UTE

-0.30 UTE

-0.28 UTE

-0.30 UTE

-0.28 UTE

-0.30 UTE

-0.32 UTE

-0.31 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 54 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

449.

44 450.

44 451.

44 452.

45 453.

45 454.

45 455.

45 456.

45 457.

45 458.

45 459.

45 460.

45 461.

45 462.

45 463.

45 464.

45 465.

45 466.

46 467.

46 468.

46 469.

46 470.

46 471.

46 472.

46 473.

46 474.

46 475.

46 476.

46 477.

46 478.

46 479.

46 480.

46 481.

46 482.

46 483.

46 484.

46 485.

46 486.

47 487.

47 488.

47 489.

47 490.

47 491.

47 492.

47 493.

47 494.

47 495.

47 496.

47 497.

47 498.

47 111 114 115 7

24 28 32 69 77 78 83 89 102 103 107 110 115 6

8 10 12 18 22 32 44 54 85 99 101 104 106 107 110 113 115 117 119 7

8 12 20 21 23 55 68 86 87 89 107 110 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.33 MAA UTE

-0.34 MAA UTE

-0.33 MAA UTE

-0.31 SAA UTE

-0.17 MAA UTE

-0.17 MAA UTE

-0.22 SAA UTE

-0.23 SAA UTE

-0.16 SAA UTE

-0.21 MAA UTE

-0.16 SAA UTE

-0.31 SAA UTE

-0.29 SAA UTE

-0.32 MAA UTE

-0.37 MAA UTE

-0.32 MAA UTE

-0.36 MAA UTE

-0.16 MAA UTE

-0.25 SAA UTE

-0.15 MAA UTE

-0.18 MAA UTE

-0.24 SAA UTE

-0.25 SAA UTE

-0.18 MAA UTE

-0.28 MAA UTE

-0.16 MAA UTE

-024 SAA UTE

-0.29 SAA UTE

-0.30 MAA UTE

-0.36 MAA UTE

-038 MAA UTE

-031 MAA UTE

-0.35 MAA UTE

-0.33 MAA UTE

-0.36 MAA UTE

-0.30 SAA UTE

-0.34 SAA UTE

-037 MAA UTE

-0.33 SAA UTE

-0.25 MAA UTE

-0.19 MAA UTE

-0.22 MAA UTE

-0.19 MAA UTE

-0.24 SAA UTE

-0.25 SAA UTE

-0.20 SAA UTE

-0.25 MAA UTE

-0.30 SAA UTE

-0.37 MAA UTE

-0.35 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 55 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

499.

47 500.

47 501.

47 502.

47 503.

48 504.

48 505.

48 506.

48 507.

48 508.

48 509.

48 510.

48 511.

48 512.

48 513.

48 514.

48 515.

48 516.

48 517.

49 518 49 519.

49 520.

49 521.

49 522.

49 523.

49 524.

49 525.

49 526.

49 527.

49 528.

49 529.

49 530.

49 531.

49 532.

49 533.

49 534.

49 535.

50 536.

50 537.

50 538.

50 539.

50 540.

50 541.

50 542.

50 543.

50 544.

50 545.

50 546.

50 547.

50 548 50 112 113 115 117 14 16 17 19 21 24 26 28 63 66 70 72 115 118 5

21 31 62 66 68 81 89 90 107 110 112 113 115 116 117 120 123 5

10 12 18 33 79 85 89 90 103 112 115 117 119 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.33 SAA UTE

-0.41 MAA UTE

-0.34 SAA UTE

-0.31 MAA UTE

-0.27 MAA UTE

-0.20 MAA UTE

-0.24 MAA UTE

-0.22 MAA UTE

-0.20 MAA UTE

-0.20 MAA UTE

-0.16 SAA UTE

-0.21 SAA UTE

-0.10 MAA UTE

-0.18 SAA UTE

-0.20 MAA UTE

-0.21 SAA UTE

-038 MAA UTE

-0.37 SAA UTE

-0.23 MAA UTE

-0.18 MAA UTE

-019 MAA UTE

-0.25 MAA UTE

-0.24 MAA UTE

-0.25 SAA UTE

-0.20 SAA UTE

-0.19 SAA UTE

-0.32 SAA UTE

-0.15 MAA UTE

-0.32 MAA UTE

-0.42 SAA UTE

-0.46 SAA UTE

-0.42 SAA UTE

-035 SAA UTE

-0.33 SAA UTE

-0.35 MAA UTE

-0.27 SAA UTE

-0.20 MAA UTE

-0.34 SAA UTE

-0.19 SAA UTE

-0.21 MAA UTE

-0.23 MAA UTE

-029 MAA UTE

-0.29 SAA UTE

-0.22 SAA UTE

-0.18 SAA UTE

-0.18 SAA UTE

-0.32 MAA UTE

-0.20 MAA UTE

-0.23 MAA UTE

-0.33 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 56 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

549.

51 550.

51 551.

51 552.

51 553.

51 554.

51 555.

51 556.

51 557.

51 558.

51 559.

51 560.

51 561.

51 562.

52 563.

52 564.

52 565.

52 566.

52 567.

52 568.

52 569.

52 570.

52 571.

52 572.

52 573.

52 574.

52 575.

53 576.

53 577.

53 578.

53 579.

53 580.

53 581.

53 582.

53 583.

53 584.

53 585.

53 586.

53 587.

53 588.

53 589.

53 590 53 591.

53 592.

53 593.

53 594.

53 595.

54 596.

54 597.

54 598.

54 14 26 27 34 48 79 89 90 104 109 110 119 120 8

18 23 32 58 67 76 89 103 104 117 119 120 5

6 9

12 14 18 30 42 52 54 56 76 89 92 104 114 115 119 120 121 3

6 14 23 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.31 SAA UTE

-0.24 SAA UTE

-0.23 MAA UTE

-0.22 SAA UTE

-0.13 MAA UTE

-0.29 SAA UTE

-0.25 SAA UTE

-0.27 SAA UTE

-0.28 SAA UTE

-0 19 MAA UTE

-0.27 MAA UTE

-0.14 SAA UTE

-0.23 MAA UTE

-0.21 MAA UTE

-0.20 MAA UTE

-0.26 MAA UTE

-0.22 SAA UTE

-0.49 MAA UTE

-0.15 MAA UTE

-0.20 SAA LTE

-0.30 SAA UTE

-0.31 SAA UTE

-0.20 SAA UTE

-0.21 MAA UTE

-0.18 SAA UTE

-0.20 SAA UTE

-0 14 MAA UTE

-0.19 MAA UTE

-0.22 SAA UTE

-0.19 MAA UTE

-0.18 MAA UTE

-0.18 SAA UTE

-0.17 MAA UTE

-0.24 SAA UTE

-0.18 SAA UTE

-0.16 MAA UTE

-0.13 MAA UTE

-0.24 MAA UTE

-0.25 SAA UTE

-0.21 SAA UTE

-0.22 SAA UTE

-0.27 MAA UTE

-0.26 MAA UTE

-0.31 SAA UTE

-0.26 MAA UTE

-0.27 SAA UTE

-0.33 MAA UTE

-0.12 SAA UTE

-0.15 MAA UTE

-0.18 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 57 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARCTEC ARC TEC

599.

54 600.

54 601.

54 602.

54 603.

54 604.

54 605.

54 606.

54 607.

54 608.

54 609.

54 610.

54 611.

54 612.

54 613.

54 614.

54 615.

54 616 54 617.

54 618.

54 619.

54 620.

54 621.

54 622.

55 623.

55 624.

55 625.

55 626.

55 627.

55 628 55 629 55 630.

55 631.

55 632.

55 633.

55 634.

55 635.

55 636.

55 637.

55 638.

55 639.

55 640.

55 641.

55 642.

55 643.

56 644.

56 645.

56 646.

56 647.

56 648.

56 24 25 28 29 31 50 67 72 92 99 102 103 104 108 109 111 112 113 116 119 120 121 125 4

8 10 11 22 23 26 30 31 33 42 44 54 56 61 62 68 76 91 112 117 7

8 9

18 31 32 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.15 MAA UTE

-0.19 SAA UTE

-0.18 SAA UTE

-0.25 MAA UTE

-0.19 MAA UTE

-0.17 MAA UTE

-029 MAA UTE

-023 SAA UTE

-0.19 SAA UTE

-0.21 SAA UTE

-0.18 MAA UTE

-0.21 MAA UTE

-0.21 SAA UTE

-008 MAA UTE

-0.43 MAA UTE

-0.37 MAA UTE

-0.23 MAA UTE

-0.31 MAA UTE

-0.24 SAA UTE

-0.34 MAA UTE

-033 MAA UTE

-0.16 MAA UTE

-0.21 MAA UTE

-0.16 MAA UTE

-0.25 SAA UTE

-0.18 SAA UTE

-0.22 MAA UTE

-0.17 SAA IJTE

-0.15 MAA UTE

-0.25 MAA IJTE

-0.22 MAA UTE

-0.23 MAA UTE

-0.20 MAA UTE

-0.29 SAA UTE

-0.18 SAA UTE

-0.13 MAA UTE

-023 SAA UTE

-0.25 SAA UTE

-0.15 MAA UTE

-0.23 SAA UTE

-0.20 MAA UTE

-0.17 SAA UTE

-0.20 SAA UTE

-0.20 SAA UTE

-0.38 SAA UTE

-0.28 MAA UTE

-0.26 SAA UTE

-0.28 SAA lUTE

-0.47 MAA UTE

-0.22 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 58 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

649.

56 650.

56 651.

56 652.

56 653.

56 654.

56 655.

56 656.

56 657.

56 658.

56 659.

56 660.

57 661.

57 662.

57 663.

57 664.

57 665.

57 666.

57 667.

57 668.

57 669.

57 670.

57 671.

57 672.

58 673.

58 674.

58 675.

58 676.

58 677.

58 678.

58 679.

58 680.

58 681.

58 682.

58 683.

58 684.

58 685.

58 686.

58 687.

58 688 59 689.

59 690.

59 691.

59 692.

59 693.

59 694 59 695.

59 696.

59 697.

59 698.

59 36 47 57 74 104 109 114 116 121 122 125 6

10 14 15 23 30 60 68 115 116 122 124 4

6 25 26 29 35 36 58 60 90 106 116 120 122 123 124 8

9 11 12 29 32 34 84 102 118 120 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA IUTE

-0.22 MAA UTE

-0.23 SAA UTE

-0.26 SAA UTE

-023 SAA UTE

-0.15 SAA UTE

-024 MAA UTE

-0.17 MAA UTE

-019 SAA UTE

-0.20 SAA UTE

-0.28 SAA UTE

-0.29 SAA UTE

-0.26 SAA UTE

-0.26 MAA UTE

-0.26 SAA UTE

-0.27 MAA UTE

-0.25 MAA UTE

-0.19 SAA UTE

-0.11 MAA UTE

-022 SAA UTE

-0.31 MAA UTE

-0.35 MAA UTE

-0.27 MAA UTE

-0.22 MAA UTE

-0.24 SAA UTE

-0.16 MAA UTE

-0.19 MAA UTE

-0.27 SAA UTE

-0.34 MAA UTE

-0.26 MAA UTE

-0.21 MAA UTE

-0.22 MAA UTE

-0.33 SAA UTE

-0.15 MAA UTE

-0.20 SAA UTE

-0.18 MAA UTE

-029 SAA UTE

-0.27 SAA UTE

-0.12 SAA UTE

-0.30 SAA UTE

-0.16 MAA UTE

-0.21 MAA UTE

-0.24 SAA UTE

-0.19 MAA UTE

-0.20 SAA UTE

-0.19 MAA UTE

-0.19 SAA UTE

-0.26 SAA UTE

-0.47 SAA UTE

-0.21 SAA UTE

-0.22 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 59 ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC

699.

59 700.

60 701.

60 702.

60 703.

60 704.

60 705.

60 706.

60 707.

60 708.

60 709.

60 710.

60 711.

60 712.

60 713.

61 714.

61 715.

61 716.

61 717.

61 718.

61 719.

61 720.

61 721.

61 722.

61 723 61 724.

61 725.

61 726.

61 727.

61 728.

62 729.

62 730.

62 731.

62 732.

62 733.

62 734.

62 735.

62 736.

62 737.

62 738.

63 739.

63 740.

63 741.

63 742.

63 743.

63 744.

63 745.

63 746.

63 747.

63 748.

63 122 7

17 22 25 33 39 105 106 116 118 119 121 122 9

18 25 26 32 35 50 88 106 108 109 110 111 114 123 32 36 37 39 102 112 117 118 120 126 24 26 31 32 39 40 58 69 92 94 109 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.19 SAA UTE

-0.34 SAA UTE

-0.18 SAA UTE

-0.18 SAA UTE

-0.21 MAA UTE

-0.19 SAA UTE

-0.22 MAA UTE

-0.27 SAA UTE

-0.21 MAA UTE

-0.30 MAA UTE

-0.20 MAA UTE

-0.22 MAA UTE

-0.22 MAA UTE

-0.22 MAA UTE

-0.15 SAA UTE

-0.34 SAA UTE

-032 SAA UTE

-0.22 MAA UTE

-0.21 MAA UTE

-0.23 SAA UTE

-0.25 SAA UTE

-0.26 SAA UTE

-0.22 SAA UTE

-0.17 SAA UTE

-0.29 MAA UTE

-0.24 SAA UTE

-0.12 MAA UTE

-0.22 SAA UTE

-0.32 SAA UTE

-0.25 MAA UTE

-0.21 SAA UTE

-0.21 MAA UTE

-0.16 SAA UTE

-0.28 SAA UTE

-0.15 MAA UTE

-0.20 SAA UTE

-0.34 MAA UTE

-0.31 MAA UTE

-0.17 SAA UTE

-0.19 SAA UTE

-0.20 SAA UTE

-0.20 SAA UTE

-0.15 MAA UTE

-0.20 MAA UTE

-0.21 SAA UTE

-0.13 MAA UTE

-0.30 MAA UTE

-0.21 SAA UTE

-0.27 MAA UTE

-0.27 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 60 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

749.

63 750.

63 751.

64 752.

64 753 64 754.

64 755.

64 756.

64 757.

64 758.

64 759.

64 760.

64 761.

64 762.

65 763.

65 764.

65 765.

65 766.

65 767.

65 768 65 769.

65 770.

65 771.

65 772.

65 773.

65 774.

65 775.

65 776.

66 777.

66 778.

66 779.

66 780.

66 781.

66 782.

66 783.

66 784.

66 785.

66 786.

66 787.

66 788.

66 789.

66 790 66 791.

67 792.

67 793.

67 794.

67 795.

67 796.

67 797.

67 798.

67 110 127 69 79 91 107 108 110 116 120 121 123 125 18 26 27 55 68 84 93 102 107 120 121 122 127 130 19 31 34 41 53 60 69 70 92 95 111 115 120 126 127 20 21 24 67 93 108 122 123 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.21 SAA UTE

-0.15 MAA UTE

-0.24 MAA UTE

-0.16 MAA UTE

-0.16 SAA UTE

-0.22 MAA UTE

-0.22 MAA UTE

-0.29 MAA UTE

-0.23 MAA UTE

-0.23 SAA UTE

-0.20 MAA UTE

-0.24 MAA UTE

-0.22 SAA UTE

-0.18 SAA UTE

-0.24 SAA UTE

-0.25 SAA UTE

-0.31 SAA UTE

-0.22 SAA UTE

-0.24 SAA UTE

-0 19 SAA UTE

-0.29 MAA UTE

-0.20 SAA UTE

-0.27 SAA UTE

-0.25 SAA UTE

-0.28 SAA UTE

-0.21 MAA UTE

-0.24 MAA UTE

-0.27 SAA UTE

-0.18 SAA UTE

-0.21 SAA UTE

-0.17 SAA UTE

-0.27 SAA UTE

-0.11 SAA UTE

-0.26 SAA UTE

-0.27 MAA UTE

-0.31 SAA UTE

-0.21 SAA UTE

-0.22 MAA UTE

-0.27 SAA UTE

-0.31 SAA UTE

-0.28 MAA UTE

-0.25 SAA UTE

-0.09 SAA UTE

-0.21 SAA UTE

-0.23 MAA UTE

-0.19 SAA UTE

-0.16 SAA UTE

-0.20 SAA UTE

-0.16 SAA UTE

-0.22 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 61 ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

799.

67 800.

68 801.

68 802.

68 803.

68 804.

68 805.

68 806.

68 807.

68 808 68 809.

68 810.

68 811.

69 812.

69 813.

69 814.

69 815.

69 816.

69 817.

69 818.

70 819.

70 820.

70 821.

70 822.

70 823.

70 824.

70 825.

70 826.

70 827.

71 828.

71 829.

71 830.

71 831.

71 832.

71 833.

72 834.

72 835.

72 836.

72 837.

72 838.

72 839.

72 840.

72 841.

72 842.

72 843.

73 844.

73 845.

73 846.

73 847.

73 848.

73 124 17 32 34 38 40 67 73 76 111 116 119 26 31 70 74 90 121 124 23 31 34 94 105 108 109 117 118 56 70 99 120 123 125 33 43 91 109 112 114 117 122 123 124 14 35 59 64 69 91 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.18 MAA UTE

-0.16 SAA UTE

-0.23 MAA UTE

-0.19 MAA UTE

-0.28 SAA UTE

-0.25 MAA UTE

-0.29 SAA UTE

-0.25 SAA UTE

-0.19 MAA UTE

-0.21 SAA UTE

-0.22 SAA UTE

-0.20 SAA UTE

-0.12 MAA UTE

-0.22 MAA UTE

-0.24 SAA UTE

-0.24 SAA UTE

-0.33 SAA UTE

-0.39 SAA UTE

-0.42 SAA UTE

-0.15 MAA UTE

-0.18 SAA UTE

-025 MAA UTE

-0.28 MAA UTE

-018 SAA UTE

-0.19 SAA UTE

-0.18 SAA UTE

-0.23 MAA UTE

-0.22 MAA UTE

-0.21 MAA UTE

-0 26 MAA UTE

-0.19 MAA UTE

-0.19 SAA UTE

-0.33 SAA UTE

-0.25 SAA UTE

-0.26 SAA UTE

-0.21 MAA UTE

-0.24 SAA UTE

-0.19 MAA UTE

-0.37 SAA UTE

-0.26 SAA UTE

-0.28 SAA UTE

-0.27 SAA UTE

-0.38 MAA UTE

-0.20 MAA UTE

-0.12 MAA UTE

-0.26 MAA UTE

-0.22 MAA UTE

-0.26 MAA UTE

-0.30 SAA UTE

-0.26 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 62 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

849.

73 850.

73 851.

73 852.

73 853.

74 854.

74 855.

74 856.

74 857.

74 858.

74 859.

74 860.

74 861.

74 862.

74 863.

74 864.

74 865.

74 866.

75 867.

75 868.

75 869.

75 870.

76 871.

76 872 76 873.

77 874.

77 875.

77 876 77 877.

78 878.

78 879.

78 880.

78 881.

78 882.

78 883.

78 884.

79 885.

79 886.

79 887.

79 888.

79 889.

79 890.

79 891.

80 892.

80 893.

80 894.

81 895.

81 896.

81 897.

81 898.

81 118 119 123 125 36 40 51 54 59 61 88 100 115 117 120 121 125 56 116 118 126 74 79 112 45 115 117 125 48 55 68 71 74 120 123 35 49 59 70 73 78 81 52 55 74 37 59 60 68 78 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.31 SAA LITE

-0.20 SAA UTE

-0.22 SAA UTE

-0.29 MAA UTE

-0.23 MAA UTE

-0 24 SAA UTE

-0.15 MAA UTE

-0.18 MAA UTE

-0.14 MAA UTE

-0.24 SAA UTE

-0.19 SAA JTE

-0.21 SAA UTE

-0.48 SAA UTE

-0.49 SAA UTE

-0.45 MAA UTE

-0.25 MAA UTE

-0.37 SAA UTE

-0.20 SAA UTE

-0.35 MAA UTE

-0.31 SAA UTE

-0.26 SAA UTE

-0.12 SAA UTE

-0.22 SAA UTE

-0.23 MAA UTE

-0.19 MAA UTE

-0.38 SAA UTE

-0.31 SAA UTE

-0.30 SAA UTE

-023 MAA UTE

-0.22 SAA UTE

-0.21 MAA UTE

-0.23 SAA UTE

-0.18 MAA UTE

-0.17 MAA UTE

-0.19 SAA UTE

-0.21 SAA UTE

-0.19 MAA UTE

-0.22 SAA UTE

-0.19 MAA UTE

-0.23 MAA UTE

-0.18 SAA UTE

-0.22 SAA UTE

-0.22 SAA UTE

-0.20 MAA UTE

-0.22 SAA UTE

-0.23 SAA UTE

-0.12 SAA UTE

-0.24 MAA UTE

-0.24 MAA UTE

-0.16 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 63 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

899.

81 900.

81 901.

82 902.

82 903.

82 904.

82 905.

82 906.

82 907.

82 908.

82 909.

82 910.

83 911.

83 912.

83 913.

83 914.

83 915.

83 916.

83 917.

83 918.

83 919.

83 920.

84 921.

84 922.

84 923.

84 924.

84 925.

84 926.

84 927.

84 928 85 929.

85 930.

85 931.

85 932.

85 933.

85 934.

85 935.

85 936.

85 937.

85 938.

85 939.

86 940.

86 941.

86 942.

86 943.

86 944.

86 945.

86 946.

86 947.

86 948.

86 101 106 35 36 47 73 75 79 100 105 107 35 36 37 38 55 59 60 71 74 81 13 14 15 24 34 49 68 86 7

14 17 24 48 49 52 81 92 101 106 15 18 19 51 71 78 79 81 82 104 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.23 SAA UTE

-0.21 MAA UTE

-0.23 SAA UTE

-0.23 MAA UTE

-0.21 MAA UTE

-0.17 MAA UTE

-0.17 MAA LITE

-0.18 MAA UTE

-0.29 MAA UTE

-0.26 SAA UTE

-0.15 MAA UTE

-0 23 MAA UTE

-0.27 SAA UTE

-0.21 SAA UTE

-0.24 SAA UTE

-0.20 MAA UTE

-0.16 SAA lrTE

-0.23 SAA UTE

-0.22 SAA UTE

-0.14 MAA UTE

-0.28 SAA UTE

-0.21 SAA UTE

-0.12 MAA UTE

-0.36 SAA UTE

-0.20 MAA UTE

-0.27 SAA UTE

-0.25 SAA UTE

-0.18 SAA UTE

-0.20 SAA UTE

-0.25 SAA UTE

-0.27 MAA UTE

-0.31 MAA UTE

-0.25 SAA UTE

-0.26 MAA UTE

-0.20 SAA UTE

-0.12 MAA UTE

-0.20 SAA UTE

-0.21 SAA UTE

-0.25 SAA UTE

-0.17 SAA UTE

-0.24 SAA UTE

-0.15 SAA UTE

-0.17 MAA UTE

-0.22 SAA UTE

-0.21 MAA UTE

-0.19 SAA UTE

-0.35 MAA UTE

-0.23 SAA UTE

-0.20 SAA UTE

-0.13 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 64 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

949.

86 950.

86 951.

86 952.

87 953.

87 954.

87 955.

87 956 87 957.

87 958.

87 959.

87 960.

87 961.

87 962.

87 963.

87 964.

88 965.

88 966.

88 967.

88 968.

88 969.

88 970.

88 971.

89 972.

89 973.

89 974.

89 975.

89 976.

89 977.

89 978.

89 979.

89 980.

89 981.

90 982.

90 983.

90 984.

90 985.

90 986.

90 987.

91 988 91 989.

91 990.

91 991.

92 992.

92 993.

92 994.

92 995.

92 996.

92 997.

92 998.

92 105 107 124 6

10 36 39 41 61 79 90 95 96 107 113 14 32 40 78 79 81 107 6

41 66 68 73 74 79 82 90 97 10 11 104 105 122 125 30 49 73 83 22 40 47 48 57 58 73 83 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.28 MAA UTE

-0.18 SAA UTE

-0.16 MAA UTE

-0.11 SAA UTE

-0.24 SAA UTE

-0.22 MAA UTE

-0.21 SAA UTE

-0.22 SAA UTE

-0.17 MAA UTE

-0.20 SAA UTE

-0.16 SAA UTE

-0.35 SAA UTE

-0.11 MAA UTE

-0.24 MAA UTE

-048 SAA UTE

-0.33 SAA UTE

-0.23 SAA UTE

-025 MAA UTE

-0.17 SAA UTE

-0.21 SAA UTE

-0.20 MAA UTE

-0.26 MAA UTE

-0.20 SAA SAA SAA MAA SAA SAA MAA SAA MAA SAA MAA SAA SAA SAA SAA SAA MAA SAA SAA SAA MAA SAA SAA MAA SAA MAA MAA UTE

-0.18 UTE

-0.20 UTE

-0.24 UTE

-0.20 UTE

-0.16 UTE

-0.21 UTE

-0.18 UTE

-0.19 UTE

-0.07 UTE

-0.18 UTE

-0.17 UTE

-0.25 UTE

-0.30 UTE

-0.45 UTE

-0.39 UTE

-0.20 UTE

-0.23 UTE

-0.24 UTE

-0.26 UTE

-0.15 UTE

-0.20 UTE

-0.37 UTE

-0.21 UTE

-0.17 UTE

-0.22 UTE

-0.21 UTE

-0.28 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 65 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

999.

1000.

1001.

1002.

1003.

1004.

1005.

1006.

1007.

1008.

1009.

1010.

1011.

1012.

1013.

1014.

1015.

1016.

1017.

1018.

1019.

1020.

1021.

1022.

1023.

1024.

1025.

1026.

1027.

1028.

1029.

1030.

1031.

1032 1033.

1034.

1035.

1036.

1037.

1038.

1039.

1040.

1041.

1042.

1043.

1044.

1045.

1046.

1047.

1048.

92 92 92 92 93 93 93 93 93 93 93 93 93 93 94 94 94 94 94 94 94 95 95 95 95 95 95 95 95 95 95 95 95 95 96 96 96 96 96 96 96 96 97 97 97 97 97 97 98 98 66 85 89 106 117 34 49 70 75 76 86 97 99 100 101 10 12 15 53 74 79 106 3

5 6

8 9

10 12 15 29 34 51 69 100 8

29 33 49 55 104 105 126 10 11 23 56 68 76 14 19 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0 27 MAA UTE

-0.20 MAA UTE

-0.20 SAA UTE

-0.41 MAA UTE

-0.19 MAA UTE

-0.32 MAA UTE

-0.20 SAA UTE

-0.13 SAA UTE

-022 SAA UTE

-021 MAA UTE

-0.35 MAA UTE

-0.36 SAA UTE

-0.26 SAA UTE

-0.16 SAA UTE

-0.25 SAA UTE

-0.15 SAA UTE

-0.26 SAA UTE

-0.29 MAA UTE

-0.24 SAA UTE

-0.13 MAA UTE

-0.18 SAA UTE

-0.29 MAA UTE

-020 SAA UTE

-0.21 SAA UTE

-0.23 SAA UTE

-0.20 MAA UTE

-0.21 MAA UTE

-0.27 MAA UTE

-0.23 SAA UTE

-0.22 MAA UTE

-0.19 SAA UTE

-0.21 MAA UTE

-0.17 SAA UTE

-0.32 SAA UTE

-0.24 SAA UTE

-0.22 MAA UTE

-0.25 MAA UTE

-0.31 MAA UTE

-0.21 MAA UTE

-0.25 SAA UTE

-025 SAA UTE

-0.27 MAA UTE

-023 MAA UTE

-0.22 SAA UTE

-0.16 SAA UTE

-0.21 MAA UTE

-0.23 MAA UTE

-0.21 SAA UTE

-0.24 MAA UTE

-0.07 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

1049.

1050.

1051.

1052.

1053.

1054.

1055.

1056.

1057.

1058.

1059.

1060.

1061.

1062.

1063.

1064.

1065.

1066.

1067.

1068.

1069.

1070.

1071.

1072.

1073.

1074.

1075.

1076.

1077.

1078 1079.

1080.

1081.

1082.

1083.

1084.

1085.

1086.

1087.

1088.

1089.

1090.

1091.

1092.

1093.

1094.

1095.

1096.

1097.

1098 98 98 99 99 99 99 99 99 99 99 99 99 99 100 100 100 100 100 100 101 101 101 101 101 101 101 101 101 101 102 102 102 102 102 102 102 103 103 103 103 103 103 104 104 104 104 104 104 104 104 67 25 31 3

28 29 30 38 40 41 53 69 99 101 7

10 36 54 62 81 12 27 41 43 62 74 76 101 104 107 7

20 32 67 74 109 119 13 73 81 93 109 119 7

11 21 24 46 53 61 67 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.23 SAA UTE

-0.23 MAA UTE

-0.25 SAA UTE

-0.21 SAA UTE

-0.18 SAA UTE

-0.23 MAA UTE

-0.25 MAA UTE

-0.23 MAA UTE

-0.19 SAA LITE

-0.29 MAA UTE

-0.23 SAA UTE

-0.24 SAA UTE

-0.18 MAA UTE

-0.21 MAA UTE

-0.17 SAA UTE

-0.20 SAA UTE

-0.19 MAA UTE

-0.21 SAA UTE

-0.21 SAA UTE

-0.19 SAA UTE

-0.20 SAA UTE

-0.21 SAA UTE

-0.21 SAA UTE

-0.25 SAA UTE

-0.20 SAA UTE

-0.23 MAA UTE

-0.17 MAA UTE

-0.26 SAA UTE

-0.20 MAA UTE

-0.15 MAA UTE

-0.17 SAA UTE

-0.21 MAA UTE

-0.13 SAA UTE

-0.20 MAA UTE

-0.23 SAA UTE

-0.21 MAA UTE

-0.21 MAA UTE

-021 MAA UTE

-0.23 SAA UTE

-0.18 SAA UTE

-0.30 MAA UTE

-0.15 SAA UTE

-0.17 SAA UTE

-0.23 SAA UTE

-0.25 MAA UTE

-0.19 SAA UTE

-0.24 SAA UTE

-0.27 SAA UTE

-0.25 SAA UTE

-0.18 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

1099.

1100.

1101.

1102.

1103.

1104.

1105.

1106.

1107.

1108.

1109.

1110.

1111.

1112.

1113.

1114.

1115.

1116.

1117.

1118.

1119.

1120.

1121.

1122.

1123.

1124.

1125.

1126.

1127.

1128.

1129.

1130.

1131.

1132.

1133.

1134.

1135.

1136.

1137.

1138.

1139.

1140.

1141.

1142.

1143.

1144.

1145.

1146.

1147.

1148.

104 104 104 104 104 105 105 105 105 105 105 105 105 105 105 105 105 105 105 106 106 106 106 106 106 106 107 107 107 107 107 107 107 107 107 107 108 108 108 108 108 108 109 109 109 109 110 110 110 110 68 73 75 79 98 120 5

36 52 53 54 62 66 68 73 75 81 85 105 112 5

6 34 37 83 95 97 11 33 37 53 59 60 63 71 80 120 18 71 72 73 76 78 40 62 64 70 10 22 37 64 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-016 SAA UTE

-0.23 MAA UTE

-0.23 MAA UTE

-0.23 MAA UTE

-0.18 MAA UTE

-0.21 SAA UTE

-0.22 SAA UTE

-0.23 SAA UTE

-0.21 MAA UTE

-0.24 SAA UTE

-0.16 SAA UTE

-0.18 SAA UTE

-0.24 SAA UTE

-0 18 MAA UTE

-0 22 SAA UTE

-0.27 SAA UTE

-0.21 SAA UTE

-0.23 SAA UTE

-0.14 MAA UTE

-0.21 MAA UTE

-0.19 SAA UTE

-0.20 SAA UTE

-0.22 SAA UTE

-0.18 SAA lUTE

-0.30 MAA UTE

-0.23 MAA UTE

-0.26 MAA UTE

-0.15 SAA UTE

-0.19 SAA UTE

-0.20 SAA UTE

-0.27 MAA UTE

-0.25 MAA UTE

-0.20 SAA UTE

-0.19 SAA UTE

-0.16 SAA UTE

-0.15 MAA UTE

-0.20 MAA UTE

-0.17 MAA UTE

-0.26 MAA UTE

-0.14 MAA UTE

-0.20 SAA UTE

-0.17 SAA UTE

-0.21 MAA UTE

-0.20 SAA UTE

-0.17 MAA UTE

-0.21 SAA UTE

-0.19 MAA UTE

-0.21 MAA UTE

-0.25 SAA UTE

-0.17 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

1149.

1150.

1151.

1152.

1153.

1154.

1155.

1156.

1157.

1158.

1159.

1160.

1161.

1162.

1163.

1164.

1165.

1166.

1167.

1168.

1169.

1170.

1171.

1172.

1173.

1174.

1175.

1176.

1177.

1178.

1179.

1180.

1181.

1182.

1183.

1184.

1185.

1186.

1187.

1188.

1189.

1190.

1191.

1192.

1193.

1194.

1195.

1196.

1197.

1198.

110 110 110 110 111 111 111 111 111 111 111 111 111 111 112 112 112 112 113 113 113 113 114 115 115 115 115 115 115 115 115 115 115 115 115 115 116 116 116 116 116 116 116 116 116 116 116 117 117 117 69 69 78 80 81 3

9 12 14 17 30 33 61 68 80 33 40 45 59 43 45 50 75 90 5

11 14 15 16 19 35 44 59 62 69 71 79 16 23 67 75 76 78 79 85 88 91 96 1

5 87 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.12 SAA UTE

-0.15 SAA UTE

-0.20 SAA UTE

-0.23 SAA UTE

-0.21 SAA UTE

-0 12 MAA UTE

-0.21 SAA UTE

-0.22 SAA UTE

-0.19 SAA UTE

-0.19 SAA UTE

-0.22 MAA UTE

-0.19 SAA UTE

-0.13 MAA UTE

-0.17 MAA UTE

-0.23 SAA UTE

-0.18 MAA UTE

-024 SAA UTE

-0.20 SAA UTE

-0.24 SAA UTE

-0.25 MAA UTE

-0.21 MAA UTE

-0.22 SAA UTE

-0.12 SAA UTE

-0.17 MAA UTE

-0.14 SAA UTE

-0.17 MAA UTE

-0.19 SAA UTE

-0.22 MAA UTE

-0.11 SAA UTE

-0.21 MAA UTE

-0.28 MAA UTE

-0.18 SAA UTE

-0.19 MAA UTE

-0.18 SAA UTE

-0.25 SAA UTE

-0.21 MAA UTE

-0.22 MAA UTE

-0.23 MAA UTE

-0.21 MAA UTE

-0.22 SAA UTE

-0.22 SAA UTE

-0.20 MAA

=TE

-0.21 MAA UTE

-0.30 MAA UTE

-0.45 SAA UTE

-0.30 MAA rITE

-0.19 SAA UTE

-0.25 MAA UTE

-0.15 SAA UTE

-0.33 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

1199.

118 1200 118 1201.

118 1202.

118 1203.

118 1204.

118 1205.

118 1206.

118 1207.

118 1208.

118 1209.

118 1210.

118 1211.

118 1212.

118 1213.

119 1214.

119 1215.

119 1216.

119 1217.

119 1218.

119 1219.

119 1220.

119 1221.

119 1222.

119 1223.

120 1224.

120 1225.

120 1226.

120 1227.

120 1228.

120 1229.

120 1230.

120 1231.

120 1232.

120 1233.

120 1234.

120 1235.

121 1236.

121 1237.

121 1238.

121 1239.

121 1240.

121 1241.

121 1242.

121 1243.

121 1244.

121 1245.

122 1246.

122 1247.

122 1248.

122 4

5 16 54 65 69 71 73 74 94 99 101 102 105 3

21 64 79 84 96 97 101 102 105 4

13 21 26 34 43 69 98 99 104 105 107 29 37 44 64 65 83 97 99 103 104 10 11 13 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.15 SAA UTE

-022 MAA UTE

-0.24 MAA UTE

-0.19 MAA UTE

-0.29 MAA UTE

-0.18 SAA UTE

-0.16 SAA UTE

-0.18 MAA UTE

-0.12 SAA UTE

-0.32 MAA UTE

-0.19 MAA UTE

-0.17 MAA UTE

-0.23 SAA UTE

-0.15 MAA UTE

-0.13 SAA UTE

-0.24 MAA UTE

-0.24 MAA UTE

-0.19 MAA UTE

-0.13 MAA UTE

-0.31 SAA UTE

-0.15 MAA UTE

-0.17 SAA UTE

-0.30 SAA LITE

-0.16 MAA UTE

-0.19 MAA UTE

-0.25 SAA UTE

-0.27 SAA UTE

-0.24 MAA UTE

-0.18 MAA UTE

-023 MAA UTE

-0.24 MAA UTE

-0.12 MAA UJTE

-0.30 MAA UTE

-0.36 MAA UTE

-0.25 MAA UTE

-0.25 MAA UTE

-0.26 MAA UTE

-0.26 SAA UTE

-0.25 SAA UTE

-0.22 MAA UTE

-0.24 MAA UTE

-0.21 MAA UTE

-0.15 MAA UTE

-0.26 MAA UTE

-0.16 MAA UTE

-0.19 MAA UTE

-0.19 MAA UTE

-0.23 MAA UTE

-0.25 37 SAA UTE

-0.24 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 70 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

1249.

1250.

1251.

1252.

1253.

1254.

1255.

1256.

1257.

1258.

1259.

1260.

1261.

1262.

1263.

1264.

1265.

1266.

1267.

1268.

1269.

1270.

1271.

1272.

1273.

1274.

1275.

1276.

1277.

1278 1279.

1280.

1281.

1282.

1283.

1284 1285.

1286.

1287.

1288.

1289.

1290.

1291.

1292.

1293.

1294.

1295.

1296.

1297.

1298.

122 122 122 122 122 122 122 122 123 123 123 123 123 123 123 123 124 124 124 124 124 124 124 124 124 124 124 124 124 124 125 125 125 125 125 125 125 126 126 126 126 126 127 127 127 127 127 127 128 128 71 48 55 66 70 74 96 102 103 5

57 63 64 68 74 90 99 8

15 16 18 30 45 51 53 56 62 68 91 98 99 55 65 68 72 75 78 82 44 60 66 71 95 28 37 40 43 59 65 24 26 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.24 MAA UTE

-0.26 SAA UTE

-0.24 MAA UTE

-0.25 SAA UTE

-0.24 SAA UTE

-0.33 MAA UTE

-0.36 SAA UTE

-0.19 MAA UTE

-0.24 MAA UTE

-0.26 SAA UTE

-0.24 SAA UTE

-0.36 MAA UTE

-0.24 MAA UTE

-0.32 SAA UTE

-0.16 MAA UTE

-0.13 MAA UTE

-0.24 MAA UTE

-0.20 MAA UTE

-0.21 MAA UTE

-0.29 SAA UTE

-0.19 MAA UTE

-0.23 SAA UTE

-023 SAA UTE

-0.22 MAA UTE

-0.25 SAA UTE

-0.28 MAA UTE

-0.28 SAA IJTE

-0.16 SAA UTE

-0.14 MAA UTE

-0.25 SAA UTE

-0.21 SAA UTE

-0.24 MAA UTE

-0.25 MAA UTE

-0.31 MAA UTE

-0.27 MAA UTE

-0 12 MAA UTE

-0.15 MAA UTE

-0.21 MAA UTE

-0.19 SAA UTE

-0.26 MAA UTE

-0.26 MAA UTE

-0.26 SAA UTE

-0.26 MAA UTE

-0.22 SAA UTE

-0.24 SAA UTE

-0.23 SAA UTE

-0 19 SAA UTE

-0.11 MAA UTE

-026 SAA UTE

-0.19 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARCTEC ARCTEC ARCTEC ARC TEC ARCTEC ARCTEC ARCTEC ARCTEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

1299.

1300.

1301.

1302.

1303.

1304.

1305.

1306.

1307.

1308.

1309.

1310.

1311.

1312.

1313.

1314.

1315.

1316.

1317.

1318 1319.

1320.

1321.

1322.

1323.

1324.

1325.

1326.

1327.

1328.

1329.

1330.

1331.

1332.

1333.

1334.

1335.

1336.

1337.

1338.

1339.

1340.

1341.

1342.

1343.

1344.

1345 1346 1347.

1348.

128 128 128 128 128 128 128 129 129 129 129 129 129 129 130 130 130 130 131 131 131 132 132 132 132 132 133 133 133 133 133 133 133 133 133 133 133 133 134 134 134 135 135 135 135 136 136 136 136 136 72 28 36 38 39 48 57 58 22 38 56 57 60 64 84 18 38 50 57 7

51 53 16 31 33 46 84 8

11 22 24 39 49 52 54 55 62 64 68 52 53 63 8

21 51 81 20 44 49 77 80 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.20 SAA UTE

-0.24 SAA UTE

-026 MAA UTE

-0.21 MAA UTE

-0.24 MAA UTE

-0.22 SAA UTE

-0 17 SAA UTE

-0.37 SAA UTE

-0.25 MAA UTE

-0.24 SAA UTE

-0.18 SAA UTE

-0.22 MAA UTE

-0.22 MAA UTE

-0.16 SAA UTE

-0.21 SAA UTE

-0.21 SAA UTE

-0.22 MAA UTE

-0.21 MAA UTE

-0.11 MAA UTE

-0.23 SAA UTE

-0.31 SAA UTE

-0.19 SAA UTE

-0.19 SAA UTE

-0.23 SAA UTE

-0.11 SAA UTE

-0.10 SAA UTE

-0.21 SAA UTE

-0.19 SAA UTE

-0.23 MAA UTE

-0.27 SAA UTE

-0.46 MAA UTE

-0.17 MAA UTE

-0.17 SAA UTE

-0.20 SAA UTE

-0.27 MAA UTE

-0.26 SAA UTE

-0.25 SAA UTE

-0.27 SAA UTE

-018 MAA UTE

-0.23 SAA UTE

-0.27 SAA UTE

-0.17 M.AA UTE

-0.14 SAA UTE

-0.21 SAA UTE

-0.12 MAA UTE

-0.23 MAA UTE

-0.17 SAA UTE

-0.22 SAA UTE

-0.11 MAA UTE

-0.20 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARCTEC ARCTEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

1349.

137 1350.

137 1351.

137 1352.

138 1353.

139 1354.

139 1355.

139 1356.

139 1357.

140 1358.

140 1359.

141 1360.

141 1361.

141 1362.

142 1363.

142 1364.

142 1365.

142 1366.

143 1367.

143 1368.

143 1369.

143 1370.

144 1371.

145 1372.

145 1373.

145 1374.

146 1375.

146 1376.

146 1377.

146 1378.

147 1379.

147 1380.

147 1381.

147 1382.

148 1383.

149 29 39 70 44 7

24 30 31 27 43 11 29 45 9

11 20 43 15 22 24 26 19 4

12 16 10 11 14 37 3

11 24 29 23 18 TABLE 8 ANO-1 "A" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.25 SAA UTE

-0.22 SAA UTE

-0.32 MAA UTE

-0.21 SAA UTE

-0.25 SAA UTE

-0.20 SAA UTE

-0.16 SAA UTE

-0.23 SAA UTE

-0.25 MAA UTE

-0.29 MAA UTE

-0.26 SAA UTE

-0.20 MAA UTE

-0.23 SAA lUrE

-0.18 SAA UTE

-0.15 SAA UTE

-0.20 SAA UTE

-0.24 SAA UTE

-0.14 MAA UTE

-029 SAA UTE

-0.24 SAA UTE

-0.30 MAA UTE

-0.18 SAA UT E

-022 SAA UTE

-0.21 SAA UTE

-0.25 SAA UTE

-0.14 SAA UTE

-0.22 SAA UTE

-0.24 SAA IJTE

-0.25 SAA UTE

-0.23 SAA UTE

-0.19 MAA UTE

-0.17 SAA UTE

-0.25 SAA UTE

-0.23 SAA LTrE

-0.16 73 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS ROW TUBE IND

%TW LOCATION STATUS REPAIR

1.

1 5

MAA UTE

-0.22 INSERVICE ARC TEC

2.

2 21 MAA UTE

-0.20 INSERVICE ARC TEC

3.

2 27 MAA UTE

-028 INSERVICE ARC TEC

4.

3 5

SAA UTE

-0.28 INSERVICE ARC TEC

5.

3 12 SAA UTE

-0.24 INSERVICE ARC TEC

6.

4 13 MAA UTE

-0.24 INSERVICE ARC TEC

7.

4 18 SAA UTE

-0.25 INSERVICE ARC TEC

8.

4 22 MAA UTE

-0.23 INSERVICE ARC TEC

9.

4 23 MAA UTE

-0.25 INSERVICE ARC TEC

10.

4 24 SAA UTE

-0.24 INSERVICE ARC TEC

11.

5 12 SAA UTE

-0.21 INSERVICE ARC TEC

12.

5 13 SAA UTE

-0.30 INSERVICE ARC TEC

13.

5 27 MAA UTE

-0.27 INSERVICE ARC TEC

14.

6 3

SAA UTE

-0.19 INSERVICE ARC TEC

15.

6 4

SAA UTE

-0.26 INSERVICE ARC TEC

16.

6 6

SAA UTE

-0.27 INSERVICE ARC TEC

17.

6 14 MAA UTE

-0.25 INSERVICE ARC TEC

18.

6 16 MAA UTE

-0.23 INSERVICE ARC TEC

19.

6 17 MAA UTE

-0.19 INSERVICE ARCTEC

20.

6 19 SAA UTE

-027 INSERVICE ARC TEC

21.

6 21 SAA UTE

-028 INSERVICE ARC TEC

22.

6 29 MAA UTE

-0.24 INSERVICE ARC TEC

23.

6 33 MAA UTE

-0.24 INSERVICE ARC TEC

24.

6 39 SAA UTE

-0.19 INSERVICE ARC TEC

25.

6 42 MAA UTE

-0.26 INSERVICE ARC TEC

26.

6 49 MAA UTE

-0.18 INSERVICE ARC TEC

27.

7 11 MAA UTE

-0.22 INSERVICE ARC TEC

28.

7 15 SAA UTE

-0.16 INSERVICE ARC TEC

29.

7 20 MAA UTE

-0.20 INSERVICE ARC TEC

30.

7 25 MAA UTE

-0.25 INSERVICE ARC TEC

31.

7 27 MAA UTE

-0.21 INSERVICE ARC TEC

32.

7 36 SAA UTE

-0.28 INSERVICE ARC TEC

33.

7 42 MAA UTE

-0.27 INSERVICE ARC TEC

34.

7 43 SAA UTE

-021 INSERVICE ARC TEC

35.

7 47 SAA UTE

-0.19 INSERVICE ARC TEC

36.

8 24 SAA UTE

-0.24 INSERVICE ARC TEC

37.

8 27 MAA UTE

-0.25 INSERVICE ARC TEC

38.

8 56 SAA UTE

-0.24 INSERVICE ARC TEC

39.

9 1

SAA UTE

-0.27 INSERVICE ARC TEC

40.

9 5

MAA UTE

-0.23 INSERVICE ARC TEC

41.

9 24 SAA UTE

-0.19 INSERVICE ARC TEC

42.

9 32 SAA UTE

-0.20 INSERVICE ARC TEC

43.

9 60 SAA UTE

-0.16 INSERVICE ARC TEC

44.

10 10 SAA UTE

-0.19 INSERVICE ARC TEC

45.

10 12 SAA UTE

-0.23 INSERVICE ARC TEC

46.

10 27 MAA UTE

-0.28 INSERVICE ARC TEC

47.

10 32 SAA UTE

-0.21 INSERVICE ARC TEC

48.

10 33 MAA UTE

-0.19 INSERVICE ARC TEC 74

49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.

74

75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
88.
89.
90.
91.
92.
93.
94.
95.
96.
97.

98.

10 10 10 10 11 11 11 11 11 11 12 12 12 12 12 13 13 13 13 13 13 13 14 14 14 14 14 14 14 14 14 14 14 14 14 15 15 16 16 16 16 16 17 17 17 17 17 17 17 18 75 36 38 56 62 4

22 25 27 30 68 17 26 28 43 60 19 25 41 49 66 68 69 2

5 19 22 28 30 33 39 40 43 52 56 73 22 34 23 32 55 64 78 2

25 34 36 37 61 77 12 TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.21 SAA UTE

-0.20 SAA UTE

-0.25 SAA UTE

-0.20 SAA UTE

-0.28 SAA UTE

-0.25 MAA UTE

-0.40 MAA UTE

-0.22 SAA UTE

-025 SAA UTE

-0 18 SAA UTE

-0.18 MAA UTE

-0.21 MAA UTE

-0.22 SAA UTE

-0.19 MAA UTE

-0.18 SAA UTE

-0.17 MAA UTE

-0.19 MAA UTE

-0.20 MAA UTE

-0.34 MAA UTE

-0.26 MAA UTE

-0.19 MAA UTE

-0.26 MAA UTE

-0.23 MAA UTE

-0.24 MAA UTE

-0.25 MAA UTE

-0.23 MAA UTE

-0.20 SAA UTE

-0.20 SAA UTE

-0.25 MAA UTE

-0.22 MAA UTE

-024 MAA UTE

-0.22 MAA UTE

-019 SAA UTE

-0.23 MAA UTE

-0.27 SAA UTE

-0.34 MAA UTE

-0.30 SAA UTE

-0.26 SAA UTE

-0.22 SAA UTE

-0.18 MAA UTE

-0.29 SAA UTE

-0.29 SAA UTE

-0.12 MAA UTE

-0.23 MAA UTE

-0.27 MAA UTE

-0.26 SAA UTE

-0.26 SAA UTE

-0.18 MAA UTE

-0.25 MAA UTE

-0.30 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVItE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

99.

100.

101.

102.

103.

104.

105.

106.

107.

108.

109.

110.

111.

112.

113.

114.

115.

116.

117.

118.

119.

120 121.

122.

123.

124.

125.

126.

127.

128.

129.

130.

131.

132.

133.

134.

135.

136.

137.

138.

139.

140.

141.

142.

143.

144.

145.

146.

147.

148.

18 18 18 18 18 18 18 18 18 19 19 19 19 19 19 20 20 20 20 20 20 21 21 21 21 21 21 21 21 22 22 22 22 22 22 22 22 23 23 23 23 23 23 23 24 24 25 25 25 25 76 18 19 27 30 50 66 72 78 85 6

25 40 70 78 86 3

14 27 54 66 82 1

14 36 38 70 74 76 86 3

50 69 74 76 82 86 91 3

7 8

31 55 67 72 33 45 18 38 85 93 TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.20 SAA UTE

-0.24 SAA UTE

-0.25 SAA UTE

-0.21 MAA UTE

-0.22 MAA UTE

-0.23 MAA UTE

-0.35 MAA UTE

-027 SAA UTE

-020 SAA UTE

-0.28 SAA UTE

-0 25 MAA UTE

-0.22 SAA UTE

-0.13 MAA UTE

-0.25 MAA UTE

-0.14 MAA UTE

-025 SAA UTE

-0.22 MAA UTE

-0.28 MAA UTE

-0.25 SAA UTE

-0.23 SAA UTE

-0.25 SAA UTE

-0.28 SAA UTE

-0.26 SAA UTE

-0.24 SAA UTE

-0.19 SAA UTE

-0.22 SAA UTE

-0.23 MAA UTE

-0.24 SAA UTE

-026 SAA UTE

-0.27 SAA UTE

-0.27 MAA UTE

-0.26 SAA UTE

-0.23 SAA UTE

-0.25 MAA UTE

-0.21 MAA UTE

-0.22 SAA UTE

-0.18 SAA UTE

-0.20 MAA UTE

-0.17 MAA UTE

-0.25 MAA UTE

-0.26 SAA UTE

-0.23 SAA UTE

-0.19 MAA UTE

-0.23 SAA UTE

-0.20 SAA UTE

-0.22 SAA UTE

-0.31 SAA UTE

-0.23 SAA UTE

-0.30 MAA UTE

-0.21 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

149.

150.

151.

152.

153.

154.

155.

156.

157.

158.

159.

160.

161.

162.

163.

164.

165.

166.

167.

168.

169.

170.

171.

172.

173.

174.

175.

176.

177.

178.

179.

180.

181.

182 183 184.

185.

186.

187.

188.

189.

190 191.

192.

193.

194.

195.

196.

197.

198.

26 26 26 26 26 26 26 27 27 28 28 28 28 28 28 28 29 29 30 30 30 30 30 30 30 30 30 31 31 31 31 31 32 32 32 32 32 32 32 33 33 33 33 33 34 34 34 34 34 34 77 49 70 78 79 81 87 89 75 88 5

6 34 68 80 81 82 41 98 9

13 18 54 79 80 96 99 100 6

12 13 61 105 2

6 10 21 84 95 101 1

8 46 76 79 10 17 26 37 40 51 TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.26 SAA UTE

-0.21 SAA UTE

-0.25 SAA UTE

-0.29 MAA UTE

-0.26 SAA UTE

-0.27 SAA UTE

-0.24 SAA UTE

-0.25 SAA UTE

-0.29 MAA UTE

-0.22 MAA UTE

-0.31 MAA UTE

-0.33 SAA UTE

-0.25 MAA UTE

-0.26 SAA UTE

-0.23 MAA UTE

-0.31 SAA UTE

-0.23 SAA UTE

-028 SAA UTE

-0.27 SAA UTE

-0.27 MAA UTE

-0.31 SAA UTE

-024 MAA UTE

-0.27 MAA UTE

-0.20 MAA UTE

-0.34 SAA UTE

-0.16 SAA UTE

-0.33 SAA UTE

-0.28 SAA UTE

-0.28 MAA UTE

-0.20 SAA UTE

-024 MAA UTE

-012 SAA UTE

-027 SAA UTE

-0.23 SAA UTE

-027 SAA UTE

-0.32 SAA UTE

-0.31 SAA UTE

-0.25 MAA UTE

-0.28 SAA UTE

-0.25 SAA UTE

-0.25 SAA UTE

-0.27 SAA UTE

-0.24 SAA UTE

-0.27 SAA UTE

-0.17 SAA UTE

-0.31 SAA UTE

-0.18 SAA UTE

-0.22 SAA UTE

-0.24 SAA UTE

-0.20 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

199.

200.

201.

202.

203.

204.

205.

206.

207.

208.

209.

210.

211.

212.

213.

214.

215.

216.

217.

218 219.

220.

221.

222.

223.

224.

225.

226.

227.

228.

229.

230.

231.

232.

233.

234.

235.

236.

237.

238.

239.

240.

241.

242.

243.

244.

245.

246.

247.

248.

34 34 34 35 35 35 35 35 35 35 35 35 35 35 35 35 36 36 36 36 36 36 36 36 36 36 36 36 36 37 37 37 37 37 37 38 38 39 39 39 39 39 39 39 39 39 39 39 39 39 78 90 100 106 1

2 6

9 14 17 27 48 54 78 81 99 103 4

11 12 13 44 66 69 95 96 97 100 101 103 10 16 68 92 101 107 14 98 4

8 9

14 15 19 45 49 59 72 90 96 104 TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.27 MAA UTE

-023 MAA

=TE

-0.15 MAA UTE

-0.32 SAA UTE

-0.25 SAA UTE

-0.25 MAA UTE

-0.22 SAA UTE

-0.27 MAA UTE

-0.36 MAA UTE

-0.19 SAA UTE

-0.17 MAA UTE

-0.18 SAA UTE

-0.20 SAA UTE

-0.25 SAA UTE

-0.25 MAA UTE

-0.23 SAA UTE

-0.31 MAA UTE

-0.24 SAA UTE

-0.22 SAA UTE

-0.18 MAA UTE

-0.23 MAA UTE

-0.22 SAA UTE

-0.22 SAA UTE

-0.29 SAA UTE

-0.28 MAA UTE

-0.26 SAA UTE

-0.28 SAA UTE

-0.28 SAA UTE

-0.27 SAA UTE

-0.25 SAA UTE

-0.27 SAA UTE

-0.23 SAA UTE

-0.31 SAA UTE

-0.20 MAA UTE

-0.20 SAA UTE

-0.28 MAA UTE

-0.21 MAA UTE

-0.26 SAA UTE

-0.24 MAA UTE

-0.22 MAA UTE

-0.22 SAA UTE

-0.25 SAA UTE

-0.26 MAA UTE

-0.26 SAA UTE

-0.24 MAA UTE

-0.28 MAA UTE

-0.21 SAA UTE

-0.28 SAA UTE

-0.23 MAA UTE

-0.14 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

249.

250.

251.

252.

253.

254.

255.

256.

257.

258.

259.

260.

261.

262.

263.

264.

265.

266.

267.

268.

269.

270.

271.

272.

273.

274.

275.

276.

277.

278 279.

280.

281.

282.

283.

284.

285.

286.

287.

288.

289.

290.

291.

292.

293.

294.

295.

296.

297.

298.

39 39 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 41 41 41 41 41 41 41 41 41 41 41 41 41 41 42 42 42 42 43 43 43 43 43 43 43 44 44 44 45 45 79 109 110 7

14 19 30 34 51 72 81 89 90 96 98 102 103 105 106 110 116 7

9 17 31 33 93 95 97 98 105 108 110 114 115 31 32 105 111 16 20 90 100 110 112 114 6

15 50 19 85 TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.17 SAA UTE

-0.20 MAA UTE

-0.22 SAA UTE

-0.23 MAA UTE

-0.25 SAA UTE

-0.21 MAA UTE

-0.21 SAA UTE

-0.22 SAA UTE

-0.24 MAA UTE

-0.27 SAA UTE

-0.25 SAA UTE

-0.16 SAA UTE

-0.16 SAA UTE

-0.16 SAA UTE

-0.17 MAA UTE

-0.13 MAA UTE

-0.16 MAA UTE

-0.33 SAA UTE

-0.26 MAA UTE

-020 SAA UTE

-0.25 SAA UTE

-0.21 SAA UTE

-0.23 SAA UTE

-0.19 SAA UTE

-0.30 MAA UTE

-0.25 SAA UTE

-0.19 SAA UTE

-0.17 SAA UTE

-0.14 SAA UTE

-0.17 SAA UTE

-0.22 SAA UTE

-0.19 MAA UTE

-0.20 SAA UTE

-0.19 SAA UTE

-0.24 MAA UTE

-0.22 SAA UTE

-0.15 MAA UTE

-0.18 SAA UTE

-0.16 SAA UTE

-0.21 SAA UTE

-041 SAA UTE

-0.27 SAA UTE

-0.21 MAA UTE

-0.23 SAA UTE

-0.20 MAA UTE

-0.33 SAA UTE

-0.23 SAA UTE

-0.19 MAA UTE

-0.27 SAA UTE

-0.23 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARCTEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARCTEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

299.

300.

301.

302.

303.

304.

305.

306.

307.

308.

309.

310.

311.

312.

313.

314.

315.

316.

317.

318.

319.

320.

321.

322.

323.

324.

325.

326.

327.

328.

329.

330.

331.

332.

333.

334.

335.

336.

337.

338.

339.

340.

341.

342.

343.

344.

345.

346.

347.

348.

45 45 46 46 47 48 48 48 48 48 48 48 49 49 50 50 51 51 51 51 51 51 52 52 52 52 52 52 53 53 53 53 54 54 54 54 54 54 55 55 55 56 56 56 56 56 56 57 57 58 80 117 120 6

15 7

21 22 86 100 102 108 116 59 117 7

20 7

19 21 117 121 124 8

11 22 61 115 116 20 61 115 117 3

10 14 22 116 117 5

20 29 10 19 23 37 49 127 5

23 14 TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.25 SAA UTE

-0.09 MAA UTE

-0.25 SAA UTE

-0.29 SAA UTE

-0.27 SAA UTE

-0.29 SAA UTE

-0.30 SAA UTE

-024 SAA UTE

-0.23 SAA UTE

-0.24 SAA UTE

-0.25 SAA UTE

-0.24 SAA UTE

-0.26 SAA UTE

-024 MAA UTE

-0.21 MAA UTE

-0.26 MAA UTE

-0.25 SAA UTE

-0.21 SAA UTE

-0.25 SAA UTE

-0.20 SAA UTE

-0.33 SAA UTE

-0.10 SAA UTE

-0.23 SAA UTE

-0.19 MAA UTE

-0.24 SAA UTE

-0.26 SAA UTE

-0.26 MAA UTE

-0.28 SAA UTE

-0.35 SAA UTE

-0.19 MAA UTE

-0.20 MAA UTE

-0.21 SAA UTE

-0.35 MAA UTE

-0.27 SAA UTE

-0.25 SAA UTE

-028 MAA UTE

-0.19 MAA lrE

-0.30 SAA UTE

-0.26 MAA UTE

-0.30 SAA UTE

-0.48 MAA UTE

-0.22 MAA UTE

-0.28 MAA UTE

-0.21 SAA IJTE

-029 SAA UTE

-0.25 SAA UTE

-0.20 MAA UTE

-0.25 SAA UTE

-0.19 SAA UTE

-0.31 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARCTEC ARCTEC ARC TEC ARCTEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

349.

350.

351.

352.

353.

354.

355.

356.

357.

358.

359.

360.

361.

362.

363.

364.

365.

366.

367.

368.

369.

370.

371.

372.

373.

374.

375.

376.

377.

378.

379.

380.

381.

382.

383.

384.

385.

386.

387.

388.

389.

390.

391.

392.

393.

394.

395.

396.

397.

398.

58 58 58 58 59 59 59 59 59 60 60 61 61 61 62 62 62 63 64 64 64 64 64 65 66 66 66 66 66 66 66 67 67 67 68 68 68 68 68 68 69 69 69 69 69 69 71 72 72 72 81 19 22 24 120 11 22 35 44 116 24 122 1

6 20 11 19 123 4

6 7

20 25 40 104 8

11 23 40 99 105 109 14 104 106 8

26 102 104 109 111 23 24 27 75 82 130 37 70 129 130 TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS SAA UTE

-025 SAA UTE

-023 SAA UTE

-024 SAA UTE

-0.24 SAA UTE

-0.41 SAA UTE

-0.25 SAA UTE

-0.20 SAA UTE

-0.26 SAA UTE

-0.18 MAA UTE

-0.16 SAA UTE

-0.25 MAA UTE

-0.17 SAA UTE

-0.30 MAA UTE

-0.24 SAA UTE

-0.30 SAA UTE

-0.24 SAA UTE

-0.24 MAA UTE

-0.28 MAA UTE

-0.21 SAA UTE

-0.31 SAA UTE

-0.24 SAA UTE

-0.25 MAA MTE

-0.30 SAA UTE

-0.17 MAA UTE

-0.23 SAA UTE

-0.37 SAA UTE

-0.20 SAA UTE

-0.24 SAA UTE

-0.23 MAA UTE

-0.24 SAA UTE

-0.22 SAA UTE

-0.24 MAA UTE

-0.22 MAA UTE

-0.24 MAA UTE

-0.23 SAA liE

-0.24 SAA UTE

-0.23 SAA UTE

-0.20 SAA UTE

-0.26 SAA UTE

-0.20 MAA UTE

-0.24 MAA UTE

-0.27 SAA UTE

-0.26 SAA UTE

-0.21 SAA UTE

-0.26 SAA UTE

-0.13 SAA UTE

-0.25 SAA UTE

-0.15 SAA UTE

-0.15 SAA UTE

-0.22 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

399.

400.

401.

402.

403.

404.

405.

406.

407.

408.

409.

410.

411.

412.

413.

414.

415.

416.

417.

418.

419.

420.

421.

422.

423.

424.

425.

426.

427.

428.

429.

430.

431.

432.

433.

434.

435.

436.

437.

438.

439.

440.

441.

442.

443.

444.

445.

446.

447.

448.

73 75 75 77 79 79 79 80 81 81 83 83 83 84 84 84 85 85 85 85 85 86 86 86 87 87 87 87 88 88 88 88 89 89 89 89 89 89 90 90 90 90 90 90 91 91 91 91 91 92 82 72 37 126 101 20 40 130 96 12 131 32 129 132 13 46 47 11 12 17 79 80 13 15 18 8

59 69 80 12 19 100 102 5

6 22 53 63 130 14 18 20 29 53 120 5

6 49 94 114 1

TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.19 MAA UTE

-0.25 SAA UTE

-0.19 SAA UTE

-0.13 SAA UTE

-0.23 SAA UTE

-0.32 SAA UTE

-0.14 SAA UTE

-0.13 SAA UTE

-0.21 MAA UTE

-014 MAA UTE

-035 SAA UTE

-0.25 SAA UTE

-0.28 MAA UTE

-0.30 SAA UTE

-0.36 MAA UTE

-026 SAA UTE

-0.26 MAA UTE

-0.23 MAA UTE

-0.19 SAA UTE

-0.15 SAA UTE

-0.15 MAA UTE

-0.27 MAA UTE

-0.21 SAA UTE

-0.24 SAA UTE

-0.21 SAA UTE

-0.25 SAA UTE

-0.21 SAA UTE

-0.20 SAA UTE

-0.30 SAA UTE

-0.24 SAA UTE

-0.22 SAA UTE

-0.12 SAA UTE

-0.39 SAA UTE

-0.20 SAA UTE

-0.24 MAA UTE

-0.27 SAA UTE

-0.14 SAA UTE

-0.19 MAA UTE

-0.25 SAA UTE

-0.26 SAA UTE

-0.29 SAA UTE

-0.21 MAA UTE

-0.20 SAA UTE

-0.21 SAA UTE

-0.28 SAA UTE

-0.28 SAA UTE

-0.22 SAA UTE

-0.23 SAA UTE

-0.20 MAA UTE

-0.16 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

449.

92 450 92 451.

92 452.

92 453.

92 454.

92 455.

92 456.

92 457.

92 458.

92 459.

92 460.

93 461.

93 462.

93 463.

94 464.

94 465.

94 466.

94 467.

95 468.

95 469.

95 470.

95 471.

96 472.

96 473.

96 474.

97 475.

98 476.

98 477.

99 478.

99 479.

99 480 100 481.

100 482.

100 483.

100 484.

101 485.

102 486.

102 487.

103 488.

103 489.

103 490.

103 491.

104 492.

104 493.

104 494.

104 495.

104 496.

104 497.

104 498.

104 5

6 8

13 68 96 99 111 113 118 123 76 91 121 38 77 103 104 1

4 22 24 4

9 98 116 9

12 6

11 37 7

11 104 111 76 3

37 3

4 22 38 7

9 11 13 27 101 102 103 TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.29 SAA UTE

-0.24 MAA UTE

-0.32 MAA UTE

-0.33 SAA UTE

-0.23 SAA UTE

-0.19 MAA UTE

-0.26 SAA UTE

-0.23 SAA UTE

-0.25 SAA UTE

-0.14 SAA UTE

-0.27 MAA UTE

-0.27 SAA UTE

-0.12 MAA UTE

-0.28 MAA UTE

-0.16 SAA UTE

-0.25 MAA UTE

-023 SAA UTE

-0.20 SAA UTE

-0.16 SAA UTE

-0.21 SAA UTE

-0.28 SAA UTE

-0.24 SAA UTE

-0.18 SAA UTE

-0.21 SAA UTE

-0.27 SAA UTE

-0.19 SAA UTE

-0.23 SAA UTE

-0.24 MAA UTE

-0.29 SAA UTE

-0.22 SAA UTE

-0.29 MAA UTE

-0.40 SAA UTE

-0.35 MAA UTE

-020 SAA UTE

-0.23 SAA UTE

-0.15 SAA UTE

-0.37 SAA UTE

-034 SAA UTE

-0.41 SAA UTE

-0.18 SAA UTE

-0.25 SAA UTE

-0.28 SAA UTE

-0.29 MAA UTE

-0.27 SAA UTE

-0.24 SAA UTE

-0.28 MAA UTE

-0.26 SAA UTE

-0.18 SAA UTE

-0.38 MAA UTE

-0.18 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE 83 ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

499.

500.

501.

502.

503.

504.

505.

506.

507.

508.

509.

510.

511.

512.

513.

514.

515.

516.

517.

518 519.

520.

521.

522.

523.

524.

525.

526.

527.

528.

529.

530.

531.

532.

533.

534.

535.

536.

537.

538.

539.

540.

541.

542.

543.

544.

545.

546.

547.

548.

105 105 105 106 106 106 106 106 106 107 107 107 107 107 107 107 107 108 108 108 108 108 108 108 108 109 109 109 109 109 110 110 110 110 111 111 111 111 111 111 111 112 112 112 112 112 113 113 113 113 84 13 17 61 1

3 9

16 93 110 6

7 14 16 17 20 93 96 9

23 24 34 94 98 107 117 8

15 64 88 100 2

16 17 117 19 21 29 30 34 97 116 2

3 12 54 93 8

15 21 94 TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.27 MAA UTE

-0.21 SAA UTE

-0.22 MAA UTE

-0.14 MAA UTE

-0.25 SAA UTE

-0.26 SAA UTE

-0.29 SAA UTE

-0.40 SAA UTE

-0.20 SAA UTE

-0.20 SAA UTE

-0.12 SAA UTE

-0.24 MAA UTE

-0.34 SAA UTE

-0.23 MAA UTE

-0.44 SAA UTE

-0.18 MAA UTE

-0.33 MAA UTE

-0.35 MAA UTE

-0.29 SAA UTE

-0.44 SAA UTE

-0.32 SAA UTE

-0.29 SAA UTE

-0.18 SAA UTE

-0.23 SAA UTE

-0.24 MAA UTE

-0.32 SAA UTE

-0.25 SAA UTE

-020 SAA UTE

-0.15 SAA UTE

-020 MAA UTE

-0.24 MAA UTE

-0.16 MAA UTE

-0.28 SAA UTE

-0.20 MAA UTE

-0.24 SAA UTE

-0.22 SAA UTE

-0.30 MAA UTE

-0.33 SAA UTE

-0.30 MAA UTE

-0.26 MAA UTE

-0.20 MAA UTE

-0.17 SAA UTE

-0.23 SAA UTE

-0.24 SAA UTE

-0.24 MAA UTE

-0.16 SAA UTE

-0.19 SAA UTE

-0.22 SAA UTE

-0.40 SAA UTE

-0.25 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARCTEC ARCTEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

549.

550.

551.

552.

553.

554.

555.

556.

557.

558.

559.

560.

561.

562.

563.

564.

565 566.

567.

568.

569.

570.

571.

572.

573.

574.

575.

576.

577.

578.

579.

580.

581.

582.

583.

584.

585.

586.

587.

588.

589.

590.

591.

592.

593.

594.

595 596.

597.

598.

113 114 114 115 115 "115 116 116 116 117 117 117 117 117 117 118 118 118 118 118 118 118 119 120 120 120 120 121 121 121 122 122 122 123 123 123 123 123 123 123 124 124 124 124 124 124 125 125 125 125 85 111 5

70 11 58 96 3

16 18 10 11 17 68 83 108 7

9 12 15 18 60 107 10 1

7 88 99 49 67 86 10 90 94 3

20 24 57 78 88 97 18 29 30 62 80 84 3

14 22 50 TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.29 SAA UTE

-0.25 SAA UTE

-0 17 SAA UTE

-031 SAA UTE

-0.18 SAA UTE

-0.20 SAA UTE

-0.31 SAA UTE

-0.23 SAA UTE

-0.23 SAA UTE

-0.23 SAA UTE

-0.24 MAA UTE

-026 SAA UTE

-0.20 SAA UTE

-0.24 MAA UTE

-0.28 SAA UTE

-0 24 SAA UTE

-0.23 SAA UTE

-0.26 MAA UTE

-0.29 SAA UTE

-0.27 SAA UTE

-0.31 MAA UTE

-0.24 SAA UTE

-0.33 MAA UTE

-0.21 SAA UTE

-0.31 SAA UTE

-0.31 SAA UTE

-0.12 NIAA UTE

-0.15 SAA UTE

-0.32 SAA UTE

-0.28 MAA UTE

-0.14 MAA UTE

-0.11 SAA UTE

-0.11 SAA UTE

-0.20 SAA UTE

-0 24 MAA UTE

-0.29 SAA UTE

-0.14 MAA UTE

-0.27 MAA UTE

-0.25 SAA UTE

-0.15 SAA UTE

-0.37 MAA UTE

-0.29 SAA UTE

-0.17 SAA UTE

-0.25 MAA UTE

-0.14 SAA UTE

-0.18 SAA UTE

-0.20 SAA UTE

-0.25 SAA UTE

-0.38 SAA UTE

-0.26 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

599.

600.

601.

602.

603.

604.

605.

606.

607.

608.

609.

610.

611.

612.

613.

614.

615.

616.

617.

618.

619.

620.

621.

622.

623.

624.

625.

626.

627.

628.

629.

630.

631.

632.

633.

634.

635.

636.

637.

638.

639.

640.

641.

642.

643.

644.

645.

646.

647.

648.

125 125 125 126 126 126 126 126 126 126 126 126 127 127 127 127 127 127 127 127 128 128 128 128 129 129 129 130 130 130 130 130 130 131 131 131 131 131 131 132 132 132 132 132 132 132 132 133 133 133 86 60 79 97 1

3 9

22 23 81 83 87 93 16 19 22 37 77 83 91 96 1

75 78 94 14 52 68 20 22 71 84 88 90 61 63 75 76 80 84 1

12 62 64 68 74 76 78 14 19 50 TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.20 SAA UTE

-0.24 SAA UTE

-0.25 SAA UTE

-0.28 MAA UTE

-0.28 SAA UTE

-0.16 SAA UTE

-0.27 SAA UTE

-0.34 SAA UTE

-0.25 MAA UTE

-0.23 SAA UTE

-0.22 SAA UTE

-0.14 SAA UTE

-0.22 SAA UTE

-0.32 SAA UTE

-0.34 SAA UTE

-0.36 SAA UTE

-0.23 SAA UTE

-0.21 SAA UTE

-0.20 MAA UTE

-0.16 SAA UTE

-0.13 SAA UTE

-0 24 SAA UTE

-0.15 SAA UTE

-0.18 SAA UTE

-0.30 MAA UTE

-0.23 SAA UTE

-0.16 SAA UTE

-0.39 SAA UTE

-031 SAA UTE

-0.22 MAA UTE

-0.25 SAA UTE

-0.26 SAA UTE

-0.21 SAA UTE

-0.16 MAA UTE

-0.24 SAA UTE

-0.28 MAA UTE

-0.22 SAA UTE

-0.24 MAA UTE

-0.25 MAA UTE

-0.08 SAA UTE

-0.40 MAA UTE

-0.19 MAA UTE

-0.21 MAA UTE

-0.25 SAA UTE

-0.22 MAA UTE

-0.23 SAA UTE

-0.21 SAA UTE

-0.23 MAA UTE

-041 SAA UTE

-0.29 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

649.

650.

651.

652.

653.

654.

655.

656.

657.

658.

659.

660.

661.

662.

663.

664.

665.

666.

667.

668.

669.

670.

671.

672.

673.

674.

675.

676.

677.

678.

679.

680.

681.

682.

683.

684.

685.

686.

687.

688.

689.

690.

691.

692.

693.

694.

695.

696.

697.

698.

133 133 133 133 133 133 133 133 133 133 134 134 134 134 134 134 134 134 134 134 134 134 134 135 135 135 135 135 135 135 135 136 136 136 136 136 136 136 136 136 137 137 137 137 137 137 137 137 137 138 87 63 66 67 71 75 77 82 83 84 85 2

10 13 14 16 58 60 69 70 71 78 82 83 11 13 17 29 40 51 52 75 10 18 22 50 52 66 74 80 81 8

38 39 48 60 66 67 68 77 18 TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.24 MAA UTE

-0.36 SAA UTE

-0.22 MAA UTE

-0.21 MAA UTE

-0.19 SAA UTE

-0.20 SAA UTE

-0.24 MAA UTE

-0 20 MAA UTE

-0.23 MAA UTE

-0.16 MAA UTE

-0.22 SAA UTE

-0.38 MAA UTE

-0.32 SAA UTE

-0.49 SAA UTE

-0.38 MAA UTE

-0.32 SAA UTE

-0.30 SAA UTE

-0.22 MAA UTE

-0.18 SAA UTE

-0.23 SAA UTE

-019 MAA UTE

-0.21 SAA UTE

-0.30 MAA UTE

-0.23 SAA UTE

-0.36 SAA UTE

-0.19 SAA UTE

-0.32 SAA UTE

-0.30 SAA LITE

-0.25 MAA UTE

-0.28 SAA UTE

-0.22 SAA UTE

-0.41 SAA UTE

-0.32 MAA UTE

-0.26 MAA UTE

-0.23 SAA UTE

-0.28 SAA UTE

-0.25 MAA UTE

-0.22 SAA UTE

-0.25 MAA UTE

-0.20 MAA UTE

-0.23 MAA UTE

-0.33 SAA UTE

-0.27 SAA UTE

-0.24 SAA UTE

-0.29 SAA UTE

-0.32 SAA UTE

-0.21 SAA UTE

-0.25 SAA UTE

-0.26 SAA UTE

-0.24 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

699.

700.

701.

702.

703.

704.

705.

706.

707.

708.

709.

710.

711.

712.

713.

714.

715.

716.

717.

718.

719.

720.

721.

722.

723.

724.

725.

726.

727.

728.

729.

730.

731.

732.

733.

734.

735.

736 737.

738.

739.

740.

741.

742.

743.

744.

745.

746.

747.

748.

138 138 138 138 138 138 138 139 139 139 139 139 139 139 140 140 140 140 140 140 140 140 140 141 141 141 141 141 141 141 141 141 141 141 142 142 142 142 142 142 142 142 142 142 143 143 143 143 143 143 88 26 38 46 47 60 66 72 8

13 42 53 65 66 72 24 30 32 38 45 48 49 57 59 4

5 6

39 43 44 57 59 60 64 68 3

5 9

14 19 22 32 53 55 59 3

5 16 31 36 49 TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS SAA UTE

-0.24 SAA UTE

-0.24 MAA UTE

-0.25 MAA UTE

-0.24 SAA UTE

-0.27 SAA UTE

-0.21 MAA UTE

-0.21 SAA UTE

-0.21 SAA UTE

-0.23 MAA UTE

-0.21 SAA UTE

-0.19 MAA UTE

-0.26 SAA UTE

-0.18 SAA UTE

-0.21 MAA UTE

-0.23 SAA UTE

-0.20 SAA UTE

-0.32 MAA UTE

-0.25 SAA UTE

-0.19 MAA UTE

-0.29 MAA UTE

-0.28 SAA UTE

-028 SAA UTE

-030 MAA UTE

-0.28 SAA UTE

-0.18 MAA UTE

-0.33 MAA UTE

-0.22 SAA UTE

-0.22 SAA UTE

-0.27 SAA UTE

-0.14 SAA UTE

-0.22 SAA UTE

-0.33 SAA UTE

-0.30 SAA UTE

-0.18 SAA UTE

-0.12 MAA UTE

-0.12 MAA UTE

-0.24 SAA UTE

-0.27 SAA UTE

-0.17 SAA UTE

-0.30 SAA UTE

-0.31 SAA UTE

-0.27 SAA UTE

-0.16 MAA UTE

-0.22 MAA UTE

-0.25 SAA UTE

-0.21 SAA UTE

-0.21 SAA UTE

-0.23 SAA UTE

-0 19 SAA UTE

-0.32 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

749.

750.

751.

752.

753.

754.

755.

756.

757.

758.

759.

760.

761.

762.

763.

764.

765.

766.

767.

768.

769.

770.

771.

772.

773.

774.

775.

776.

777.

778.

779.

780.

781.

782.

783.

784.

785.

786.

787.

788.

789.

790.

791.

792.

793.

794.

795.

796.

797.

143 143 143 144 144 144 144 144 144 145 145 145 145 145 146 146 146 146 146 146 146 146 146 146 146 146 147 147 147 147 148 148 148 148 149 149 149 149 149 149 149 150 150 150 150 150 150 150 151 89 58 59 60 17 40 44 49 51 56 13 28 39 42 43 2

3 17 18 19 27 29 32 35 39 42 48 23 24 38 44 25 32 34 35 3

6 8

10 11 16 32 4

6 14 18 22 23 26 2

TABLE 9 ANO-1 "B" OTSG 1R17 TEC ARC RESULTS MAA UTE

-0.24 MAA UTE

-0.26 MAA UTE

-0.26 SAA UTE

-0.25 SAA UTE

-0.26 MAA UTE

-0.25 SAA UTE

-0.31 SAA UTE

-0.34 MAA UTE

-0.25 MAA UTE

-0.19 SAA UTE

-0.28 SAA UTE

-0.32 SAA UTE

-0.20 MAA UTE

-0.33 SAA UTE

-0.32 SAA UTE

-0.29 SAA ULTE

-025 SAA UTE

-0.16 SAA UTE

-0.25 SAA UTE

-0.24 MAA UTE

-0.23 SAA UTE

-0.24 MAA UTE

-0.24 MAA UTE

-0.28 MAA UTE

-0.23 SAA UTE

-0.27 SAA UTE

-0.21 SAA UTE

-0.25 SAA UTE

-0.24 MAA UTE

-0.16 SAA UTE

-0.26 MAA UTE

-0.23 MAA UTE

-0.20 SAA UTE

-0.25 SAA UTE

-0.08 SAA UTE

-0.23 MAA UTE

-0.08 SAA UTE

-0.13 SAA UTE

-0.26 MAA UTE

-0.23 MAA UTE

-0.18 MAA UTE

-0.19 MAA UTE

-0.18 SAA UTE

-0.20 SAA UTE

-0.22 MAA UTE

-0.16 MAA UTE

-0.21 MAA UTE

-0.28 SAA UTE

-0.25 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARCTEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC ARC TEC

TABLE 10 ANO-1 "A" OTSG 1R17 REROLL RESULTS ROW TUBE IND

%TW LOCATION STATUS REPAIR

1.

2 3

SCI UTE

-0.34 INSERVICE RRT

2.

5 44 SAA UTE

-0.32 INSERVICE RRT

3.

5 46 SAA UTE

-0.34 INSERVICE RRT

4.

6 50 SAA UTE

-0.38 INSERVICE RRT

5.

7 21 MAA UTE

-0.29 INSERVICE RRT

6.

7 43 MAA UTE

-0.44 INSERVICE RRT

7.

7 52 MAA UTE

-0.30 INSERVICE RRT

8.

8 6

MAA UTE

-0.23 INSERVICE RRT

9.

8 56 SAA UTE

-0.23 INSERVICE RRT

10.

9 15 MAA UTE

-041 INSERVICE RRT

11.

10 59 SCI UTE

-0.18 INSERVICE RRT

12.

13 64 MAA UTE

-0.18 INSERVICE RRT

13.

13 74 SCI UTE

-0.25 INSERVICE RRT

14.

14 65 MAA UTE

-0.36 INSERVICE RRT

15.

14 66 MAA UTE

-0.33 INSERVICE RRT

16.

14 72 MAA UTE

-0.29 INSERVICE RRT

17.

18 5

MAA UTE

-0.22 INSERVICE RRT

18.

18 78 MAA UTE

-0.43 INSERVICE RRT

19.

18 82 MAA UTE

-0.22 INSERVICE RRT

20.

19 6

MAA UTE

-0.16 INSERVICE RRT

21.

19 57 SAI UTE

-1.72 INSERVICE RRT

22.

20 9

MAA UTE

-0.26 INSERVICE RRT

23.

22 4

MAA UTE

-0.30 INSERVICE RRT

24.

24 7

SVI UTE

-1.55 INSERVICE RRT

25.

24 89 MAA UTE

-0.42 INSERVICE RRT

26.

26 4

MAA UTE

-0.23 INSERVICE RRT

27.

28 15 SCI UTE

-0.25 INSERVICE RRT 28 28 98 MAA UTE

-0.42 INSERVICE RRT

29.

29 4

MAA UTE

-0.25 INSERVICE RRT

30.

29 6

MAA UTE

-0.22 INSERVICE RRT

31.

30 2

SAA UTE

-0.13 INSERVICE RRT

32.

30 3

MAA UTE

-0.33 INSERVICE RRT

33.

30 4

MAA UTE

-0.22 INSERVICE RRT

34.

30 5

MAA UTE

-0.30 INSERVICE RRT

35.

32 3

MAA UTE

-0.19 INSERVICE RRT

36.

32 6

MAA UTE

-0.29 INSERVICE RRT

37.

32 103 MAA UTE

-0.29 INSERVICE RRT

38.

32 105 SCI UTE

-0.34 INSERVICE RRT

39.

33 4

MAA UTE

-0.17 INSERVICE RRT

40.

33 107 SAA UTE

-0.29 INSERVICE RRT

41.

34 104 MAA UTE

-0.29 INSERVICE RRT

42.

34 107 SVI UTE

-5.12 INSERVICE RRT

43.

35 77 SAI UTE

-1.44 INSERVICE RRT

44.

35 106 MAA UTE

-0.26 INSERVICE RRT

45.

36 2

SAA UTE

-0.30 INSERVICE RRT

46.

36 10 MAA UTE

-0.24 INSERVICE RRT

47.

36 106 MAA UTE

-0.28 INSERVICE RRT

48.

36 108 MAA 13TE

-0.17 INSERVICE RRT 90

49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
88.
89.
90.
91.
92.
93.
94.
95.
96.
97.

98.

37 37 37 37 37 38 40 40 41 43 44 45 46 46 46 46 46 46 46 47 48 48 48 49 52 52 53 54 54 54 54 54 56 58 58 58 58 61 63 64 64 65 65 71 71 74 74 75 75 77 91 7

49 58 60 107 29 4

115 5

6 114 7

6 48 72 113 115 117 119 48 24 39 118 123 41 119 121 6

45 50 121 125 112 4

38 46 88 9

4 123 125 35 130 80 126 121 125 48 126 125 TABLE 10 ANO-1 "A" OTSG 1R17 REROLL RESULTS SVI UTE

-4.49 SCI UTE

-0.29 MAI UTE

-1.48 SAI UTE

-1.46 MAA UTE

-0.33 SAI UTE

-1.51 MAA UTE

-026 MAA UTE

-0.26 SVI UTE

-4.56 MAA UTE

-0.22 MAA UTE

-0.34 MAA UTE

-0.31 MAA UTE

-0.16 SO UTE

-0.14 MVI UTE

-4.33 MAA UTE

-0.33 MAA UTE

-0.36 MAA UTE

-0.30 SAA UTE

-0.34 SO UTE

-0.13 SO UTE

-0.17 SAI UTE

-1.47 MAA UTE

-0.37 MAA UTE

-0.27 SAI UTE

-1.74 MAA UTE

-0.18 MAA UTE

-0.27 MAA UTE

-0.12 SVI UTE

-4.46 MCI UTE

-0.25 MAA UTE

-0.16 MAA UTE

-0.21 MCI UTE

-0.24 MAA UTE

-0.24 SAI UTE

-1.76 SAI UTE

-1.81 SCI UTE

-0.18 SAI UTE

-1.75 SAI UTE

-1.85 MAA UTE

-0.24 MAA UTE

-0.22 SAI UTE

-1.47 MAA UTE

-024 SCI UTE

-0.38 SCI UTE

-0.26 MAA UTE

-0.25 MAA UTE

-0.37 SCI UTE

-0.26 SAA UTE

-0.26 SAA UTE

-030 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE

  • INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT
99.

100.

101.

102.

103.

104.

105.

106.

107.

108.

109.

110.

111.

112.

113.

114.

115.

116.

117.

118.

119.

120.

121.

122.

123.

124.

125.

126.

127.

128.

129.

130.

131.

132.

133.

134.

135.

136.

137.

138.

139.

140.

141.

142.

143.

144.

145.

146 147.

148.

79 80 82 85 86 86 87 87 87 87 88 90 90 91 92 92 93 94 95 95 95 96 96 97 97 99 99 99 99 100 100 100 102 103 104 104 104 104 104 105 105 106 106 106 107 107 108 109 109 111 92 105 54 29 7

8 24 6

45 46 80 9

49 72 12 90 120 34 8

62 69 116 45 114 43 51 3

38 43 124 3

7 25 79 12 11 20 21 114 120 5

24 5

19 111 11 29 23 9

20 16 TABLE 10 ANO-1 "A" OTSG 1R17 REROLL RESULTS MAI UTE

-1.51 MAI UTE

-1.69 SAI UTE

-1.35 SAI UTE

-1.44 SAI UTE

-1.50 SAI UTE

-1.49 VOL UTE

-2.42 SCI UTE

-0.23 SCI UTE

-0.27 SVI UTE

-4.74 SCI UTE

-026 SAI UTE

-1.50 SAI UTE

-1.30 SAI UTE

-1.32 SAI UTE

-1.58 SO UTE

-0.20 SCI UTE

-0.27 MAI UTE

-1.49 SAI UTE

-1.63 SAI UTE

-1.34 SVI UTE

-4.75 SCI UTE

-0.20 SCI UTE

-0.31 MCI UTE

-0.29 SVI UTE

-4.53 MAA UTE

-0.25 SAI UTE

-1.73 MCI UTE

-0.28 MAI UTE

-1.46 SAI UTE

-1.30 MAA UTE

-0.21 SAI UTE

-1.50 MCI UTE

-0.18 SAI UTE

-1.47 SAI UTE

-1.51 SVI UTE

-9.35 SAI UTE

-1.49 MCI UTE

-0.29 MAA UTE

-0.18 MAA UTE

-0.21 MCI UTE

-0.27 MAA UTE

-0.21 SVI UTE

-4.32 SCI UTE

-0.25 SAI UTE

-1.50 MAI UTE

-1.83 SAI UTE

-1.42 SCI UTE

-0.24 SCI UTE

-0.23 SVI UTE

-4.61 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT

149.

150.

151.

152.

153.

154.

155.

156.

157.

158.

159.

160.

161.

162.

163.

164.

165.

166.

167.

168.

169.

170.

171.

172.

173.

174.

175.

176.

177.

178.

179.

180.

181.

182.

183.

184.

185.

186.

187.

111 111 115 115 117 117 117 118 119 120 120 120 120 120 121 121 122 123 123 124 124 124 125 126 129 129 131 131 132 135 136 136 141 145 147 147 148 150 151 93 19 97 6

18 1

5 17 101 3

4 92 104 105 107 103 104 102 5

99 8

9 99 100 95 52 69 6

23 84 81 21 80 11 4

3 24 12 14 10 TABLE 10 ANO-1 "A" OTSG 1R17 REROLL RESULTS SVI UTE

-454 SVI UTE

-4.58 SAI UTE

-1.62 ScI UTE

-027 SAA UTE

-0.25 MAA UTE

-0.15 SCI UTE

-0.34 MAA UTE

-0.17 MAA UTE

-0.13 MAA UTE

-0.19 SVI UTE

-474 MAA UTE

-0.36 MAA UTE

-0.25 MAA UTE

-0.25 MAA UTE

-0.16 MAA UTE

-0.19 MAA UTE

-0.36 MAA UTE

-0.24 MAA UTE

-0.13 MAA UTE

-0.24 ScI UTE

-0.34 MAA UTE

-025 SAI UTE

-1.80 MAA UTE

-0.26 SVI UTE

-4.86 SVI UTE

-3.83 MCI UTE

-0.28 SVI UTE

-4.42 ScI IJTE

-0.24 SAA UTE

-0.12 SCI UTE

-0.24 MAA UTE

-0.20 MAA UTE

-0.26 SAA UTE

-0.22 SAA UTE

-0.23 MAA UTE

-0.17 ScI UTE

-0.24 SAI UTE

-1.50 SVI UTIE

-1.13 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT

TABLE 11 ANO-1 "B" OTSG 1R17 REROLL RESULTS ROW TUBE IND

%TW LOCATION

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.

48.

1 2

2 3

4 4

5 6

6 6

6 7

8 9

9 10 10 11 11 11 14 14 17 18 19 20 21 21 22 22 27 28 31 32 32 33 35 35 43 45 51 54 56 56 57 57 62 63 STATUS REPAIR 5

21 27 5

4 13 36 3

4 17 49 25 56 1

60 33 62 4

35 68 2

73 2

85 86 3

1 82 3

91 7

5 105 2

102 1

1 2

115 120 124 76 125 127 5

127 27 4

MAA MAA MAA SAA SCO MAA SAI SAA SAA MAA MAA MAA SAA SAA SCO MAI SAA SAA SAI SAA MAA MAA SAA SAA MAA MAA SAA SAI SAA SAA SCO MAA MAA SAA MCI SAA MAA SAA MAI SAA SAA SAI ScI SAI MAA ScI SvI MAA UTE

-0.22 UTE

-0.20 UTE

-0.28 UTE

-0.28 UTE

-0.23 UTE

-0.24 UTE

-1.48 UTE

-0.19 UTE

-0.26 UTE

-0.19 UTE

-0.18 UTE

-0.25 UTE

-024 UTE

-0.27 UTE

-0.18 UTE

-1.49 UTE

-0.20 UTE

-0.28 UTE

-1.56 UTE

-0.18 UTE

-0.23 UTE

-0.27 UTE

-0.12 UTE

-0.20 UTE

-0.14 UTE

-0.25 UTE

-0.28 UTE

-4.63 UTE

-0.27 UTE

-0.18 UTE

-0.28 UTE

-0.22 UTE

-0.12 UTE

-0.27 UTE

-3.62 UTE

-0.25 UTE

-0.32 UTE

-0.25 UTE

-5.04 UTE

-0.09 UTE

-0.10 UTE

-1.43 UTE

-0.26 UTE

-1.50 UTE

-0.25 UTE

-0.31 UTE

-1.50 UTE

-0.28 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT 94

49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
88.
89.
90.
91.
92.
93.
94.
95.
96.
97.

98.

68 72 72 74 75 78 79 81 82 82 83 83 85 85 86 86 87 88 88 89 89 91 92 93 95 95 95 96 97 98 98 100 101 106 106 108 108 109 109 110 110 110 111 111 111 112 112 112 116 117 95 50 129 130 39 126 125 130 131 78 80 103 132 97 127 22 97 105 101 128 102 130 72 1

108 1

58 101 115 20 40 109 28 66 1

3 58 61 106 108 2

75 117 19 44 116 2

3 64 3

108 TABLE 11 ANO-1 "B" OTSG 1R17 REROLL RESULTS SAI UTE

-1.49 SAA UTE

-0 15 SAA UTE

-0.22 SVI UTE

-1.30 SAA UTE

-0.19 SO UTE

-0.23 SAA UTE

-0.14 MAA UTE

-0.14 MCI UTE

-1.10 SAI UTE

-1.83 SAI UTE

-1.50 SAA UTE

-0.28 SAI UTE

-4.83 SAI UTE

-1.48 MAI UTE

-1.59 MAI UTE

-4.57 SAI UTE

-1.51 SAI UTE

-1.49 SAI UTE

-1.50 SAI UTE

-1.51 SAA UTE

-0.19 SAI UTE

-0.43 MAA LUTE

-0.16 SAI UTE

-1.55 SAA UTE

-0.16 SAI UTE

-1.51 SVI UTE

-2.28 SAI UTE

-1.83 SAI UTE

-1.51 SAI UTE

-1.49 SAI UTE

-2.10 MAI UTE

-4.98 SVI UTE

-405 MAA UTE

-0.14 MAA ITE

-0.25 SAI UTE

-1.25 SAI UTE

-1.44 SAI UTE

-1.50 SAI UTE

-1.00 MAA UTE

-0.24 SAI UTE

-1.44 SAA UTE

-0.20 SCI UTE

-0.30 SAI UTE

-1.55 MAA UTE

-0.20 MAA UTE

-0.17 SAA UTE

-0.23 MAI UTE

-1.46 SAA UTE

-0.31 MAA UTE

-0.28 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT

99.

100.

101.

102.

103.

104.

105.

106.

107.

108.

109.

110.

111.

112.

113.

114.

115.

116.

117.

118.

119.

120.

121.

122.

123.

124.

125.

126.

127.

128.

129.

130.

131.

132.

133.

134.

135.

136.

137.

138.

139.

140.

141.

142.

143.

144.

145, 146.

147.

148.

118 118 118 119 119 120 123 124 125 126 126 127 128 128 128 128 132 132 133 133 133 134 134 136 136 139 141 141 142 142 143 143 143 144 144 144 144 145 146 146 146 146 147 148 149 149 149 149 150 150 96 87 95 107 45 50 1

3 30 48 1

3 96 1

24 41 94 1

47 48 84 85 2

83 80 81 72 4

68 3

14 3

59 60 12 13 44 56 9

2 3

35 48 44 34 3

6 16 32 4

6 TABLE 11 ANO-1 "B" OTSG 1R17 REROLL RESULTS SAI UTE

-1.50 MAI LrTE

-1.50 MAA UTE

-0.24 SAI UTE

-1.54 MAI UTE

-1.50 MAA UTE

-0.21 SAA UTE

-0.20 MAI UTE

-0.80 SCI UTE

-0.90 SAA UTE

-0.28 MAA UTE

-0.28 MAA UTE

-0 16 SAA UTE

-0.13 SAI UTE

-1.78 SAI UTE

-1.50 SAA UTE

-0.18 MAA UTE

-0.08 SCI UTE

-3.72 SCI UTE

-3.68 SAI UTE

-1.67 MAA UTE

-0.16 MAA UTE

-0.22 SCI UTE

-025 SAA UTE

-0.25 MAA UTE

-0.20 SAA UTE

-0.21 MAA UTE

-0.28 SAA UTE

-0.18 SAA UTE

-0.12 SO UTE

-0.16 MAA UTE

-0.25 MAA UTE

-026 MAA UTE

-026 MAI UTE

-4.82 SAI UTE

-1.66 MAA UTE

-0.25 MAA UTE

-0.25 SVI UTE

-0.24 SAA UTE

-0.32 SAA UTE

-0.29 MAA UTE

-0.24 SAA UTE

-0.27 MAA UTE

-0.16 MAA UTE

-0.20 SAA UTE

-0.08 SAA UTE

-0.23 MAA UTE

-0.23 MAA UTE

-0.18 MAA UTE

-0.19 MAA UTE

-0.18 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT

TABLE 11 ANO-1 "B" OTSG 1R17 REROLL RESULTS 14 SAA UTE

-0.

18 SAA UTE

-O.

22 MAA UTE

-0.:

23 26 2

MAA MAA SAA UTE UTE UTE 20 26 16

-0.21

-0.28

-0.25 97 149.

150.

151 152.

153.

154.

150 150 150 150 150 151 INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE INSERVICE RRT RRT RRT RRT RRT RRT

TABLE 12 ANO-1 "A" OTSG 1R17 PLUGGING RESULTS ROW TUBE IND.

%TW LOCATION STATUS REPAIR

1.

4 37 SI 15S +3.09 00S PLUG/STAB

2.

6 28 SMI 10S +10.83 00S PLUG

3.

9 27 SVI UTE -4.54 OOS PLUG

4.

9 28 SVI UTE -4.30 QOS PLUG

5.

10 1

PTP 00S PLUG/STAB

6.

10 2

PTP 00S PLUG/STAB

7.

11 2

PTP OOS PLUG/STAB

8.

11 4

PTP OOS PLUG/STAB

9.

12 4

PTP 00S PLUG/STAB

10.

12 5

PTP QOS PLUG/STAB

11.

23 7

SI 15S -13.47 OOS PLUG

12.

26 73 SMI UTS +0.72 OOS PLUG

13.

28 69 SMI UTS -6.33 QOS PLUG

14.

30 104 MCI UTE -0.22 OOS PLUG/STAB

15.

34 107 SVI UTE -5.12 OOS PLUG/STAB

16.

35 103 SVI UTS -18.10 OOS PLUG

17.

41 9

SVI UTE -4.64 OOS PLUG

18.

43 108 SMI UTS +0.82 OOS PLUG

19.

44 12 SAI 14S -4.28 00S SLV PLUG

20.

44 16 SAI 15S +10.44 OOS PLUG/STAB

21.

50 20 SMI 14S -4.28 OOS PLUG

22.

51 19 SAI 15S +9.16 OOS PLUG

23.

51 113 SI 11S +4.20 OOS PLUG

24.

53 123 SMI 12S -10.67 OOS PLUG

25.

53 124 SI 11S -6.10 OOS PLUG/STAB

26.

54 72 SMI 15S +18.81 OOS PLUG

27.

58 91 OBS QOS PLUG

28.

60 128 SMI 14S -14.70 OOS PLUG/STAB

29.

62 29 SMI 09S -1.66 OOS PLUG

30.

62 120 SMI UTS +0.83 OOS PLUG

31.

63 33 OBS 00S PLUG

32.

65 84 SAI UTS -5.30 QOS PLUG

33.

66 33 PTP QOS PLUG

34.

66 125 SMI UTS +0.55 QOS PLUG

35.

69 69 SVI UTE -3.59 OOS PLUG

36.

69 132 OBS OOS PLUG/STAB

37.

72 73 SMI UTS -16.32 OOS PLUG

38.

73 69 SMI UTS +0.51 OOS PLUG

39.

75 124 SI 1OS +11.73 QOS PLUG

40.

83 3

SVI 13S +6.65 QOS SLV PLUG

41.

84 25 SMI 15S+3870 OOS SLVPLUG

42.

87 16 SVI UTE -9.10 OOS PLUG

43.

93 124 PTP QOS PLUG/STAB

44.

94 127 PTP 00S PLUG/STAB

45.

95 127 PTP OOS PLUG/STAB

46.

96 126 PTP QOS PLUG/STAB

47.

96 127 PTP OCS PLUG/STAB

48.

98 126 PTP QOS PLUG/STAB 98

TABLE 12 ANO-1 "A" OTSG 1R17 PLUGGING RESULTS SAI 13S+5.82 SVI UTE -9.35 SAI 14S -6 34 SAI 15S+20.17 SCI UTE -0.32 SAI UTS +0 68 PTP PTP PTP PTP PTP PTP SAI 12S -6.26 SVI UTE -3.89

49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.

76.

99 104 106 116 123 124 126 126 127 127 128 128 131 133 136 136 136 136 136 136 137 137 138 138 138 139 139 141 35 20 21 15 13 12 95 96 94 96 93 94 1

15 75 76 77 78 79 80 73 76 72 74 75 72 73 55 00S OOS OOS 00S OOS 00S OOS OOS OOS 00S OOS 00S 00S OOS OOS 00S OOS OOS OOS 00S OOS 00S OOS OOS 00S OOS 00S 00S 99 PTP PTP PTP PTP PTP PTP PTP PTP PTP PTP PTP PTP PTP SAI lS -13.43 PLUG PLUG PLUG PLUG PLUG PLUG PLUGISTAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG PLUG/STAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG/STAB PLUG

TABLE 13 ANO-1 "B" OTSG 1R17 PLUGGING RESULTS ROW TUBE IND.

%TW LOCATION STATUS REPAIR

1.

1 2

PTP QOS PLUG/STAB

2.

1 3

PTP QOS PLUG/STAB

3.

2 7

PTP QOS PLUG/STAB

4.

2 9

PTP 00S PLUG/STAB

5.

3 11 PTP QOS PLUG/STAB

6.

3 12 PTP 00S PLUG/STAB

7.

10 59 PTP QOS PLUG/STAB 8

10 60 PTP OOS PLUG/STAB

9.

11 60 PTP OOS PLUG/STAB

10.

11 62 PTP OOS PLUG/STAB

11.

12 62 PTP OOS PLUG/STAB

12.

12 63 PTP OOS PLUG/STAB

13.

19 73 SVI UTE -5.01 OOS PLUG

14.

21 90 SAI UTE -4.60 QOS PLUG/STAB

15.

40 100 SVI UTS +0.18 OOS PLUG/STAB

16.

59 3

SAI 15S -3.39 OOS PLUG/STAB

17.

61 1

SAI 15S -5.80 00S PLUG/STAB

18.

61 4

SAI UTE -4.91 QOS PLUG

19.

64 6

PTP QOS PLUG/STAB

20.

64 7

PTP QOS PLUG/STAB

21.

64 8

PTP OOS PLUG/STAB

22.

65 8

PTP OOS PLUG/STAB

23.

66 6

PTP OOS PLUG/STAB

24.

66 7

PTP OOS PLUG/STAB

25.

66 8

PTP 00S PLUG/STAB

26.

75 21 SVI 06S -0.87 00S SLV PLUG

27.

82 76 SVI LTS +1.93 00S PLUG

28.

85 14 MAI UTE - 4.17 OOS PLUG

29.

88 7

SAI UTE -3.80 OOS PLUG

30.

115 6

PTP 00S PLUG/STAB

31.

116 4

PTP OOS PLUG/STAB

32.

116 6

PTP OOS PLUG/STAB

33.

116 33 MAI UTE -3.73 OOS PLUG

34.

117 3

PTP OOS PLUG/STAB

35.

117 4

PTP 00S PLUG/STAB

36.

128 80 SVI 02S -0.93 OOS PLUG

37.

141 2

PTP OOS PLUG/STAB

38.

141 3

PTP OOS PLUG/STAB

39.

142 2

PTP OOS PLUG/STAB

40.

148 20 SAI 14S +12.55 OOS PLUG/STAB

41.

149 4

PTP OOS PLUG/STAB

42.

149 5

PTP QOS PLUG/STAB

43.

150 2

PTP OOS PLUG/STAB 100