Text
CommittedftolNuclear ExcellenceMa N
Mano K. Nazar Site Vice President Prairie Island Nuclear Generating Plant Nuclear Management Company, LLC 1717 Wakonade Dr. East = Welch MN 55089 December 12,2002 1
Technical Specifications 5.6.4 US Nuclear.Regulatory Commission Attn: Document Control Desk Washington, DC 20555 PRAIRIE ISLAND.NUCLEAR GENERATING PLANT Docket No.
50-282:,',License No.
DPR-42 50-306 DPR-60 Monthly Operating Report November 2002 Attached is the Monthly Operating Report for November 2002 for the Prairie Island Nuclear Generating Plant. The Nuclear Management Company has not made new or revised existing Nuclear Regulatory Commission commitments in this letter or the attachment.
Mano K. Nazar Site Vice Presi nt Prairie Island uclear Generating Plant c:
Regio al Administrator-Region III, NRC NRR Project Manager, NRC Senior Resident Inspector, NRC James Bernstein, State of Minnesota
Attachment:
Monthly Operating Report; November 2002
NRC MONTHLY REPORT PRINTED 12110/2002 Page 1 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO. 1 DATE12/1012002 COMPLETED BY DALE DUGSTAD PHONE 651-388-11214376 SOUMINRYOF O OATING EXPERIENCE MIONTH: NOVEMBER 2002 During the month of November, Unit I was base loaded. There was one power reduction and one shutdown.,o,
On the 4th at 0107, the Unit started coastdown operation to prepare for the scheduled refueling outage.
- The outage started on the 15th at 2021, when thereadtor was manually tripped due to a high level in the 13A Feedwater Heater which could not be reduced.
This was a planned decision In response to a known problem with an extraction bellows.
The Unit remained In the refueling outage for the rest of the month.
There are no other items to report.
CURRENT CONTINUOUS OPERATING RUN OF 0 DAYS
NRC MONTHLY REPORT PRINTED 12/10/2002 Page 2 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO. 1 DATE 1211012002 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 pEA NG DATA REPORT OP2.ATIN STATUS...
- 1. UNIT NAME:
PRAIRIE ISLAND NO. 1 2.'REPORTING PERIOD:
- '- I'NOVEMBER
," 2002
- 3. LICENSED THERMAL POWER (MWT): 1650
- 4. NAMEPLATE RATING (GROSS MWE):
593
- 5. DESIGN ELECTRICAL RATING (NET MWE): 538
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):
554
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):
522
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3-7) SINCE LAST REPORT, GIVE REASON:
NONE
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE):
NONE
- 10. REASONS FOR RESTRICTIONS, IF ANY:
NONE THIS MONTH YR-TO-DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD
- 12. NUMBER OF HOURS REACTOR CRITICAL
- 13. REACTOR RESERVE SHUTDOWN HOURS
- 14. HOURS GENERATOR ON-LINE
- 15. UNIT RESERVE SHUTDOWN HOURS
- 16. GROSS THERMAL ENERGY GENERATED (MWH)
- 17. GROSS ELECTRICAL ENERGY GENERATED (MWH)
- 18. NET ELECTRICAL ENERGY GENERATED (MWH)
- 19. UNIT SERVICE FACTOR
- 20. UNIT AVAILABILITY FACTOR
- 21. UNIT CAPACITY FACTOR (MDC NET)
- 22. UNIT CAPACITY FACTOR ( DER NET)
- 23. UNIT FORCED OUTAGE RATE
- 24. FORCED OUTAGE HOURS 720 356.3 0.0 356.3 0.0 566001 195070 184789 49.5 49.5 49.2 47.9 0.0 0.0 8016 7652.3 0.0 7652.3 0.0 12550592 4284020 4055311 955 95.5 969 94.4 0.0 0.0 253848 219584.4 5571.1 217626.9 0.0 347319848 115490270 108745818 85.7 85.7 84.4 80.7 4.6 10462.7
- ° J
°,.*.
NRC MONTHLY REPORT PRINTED 12110/2002 Page 3 DOCKET NO. 50-282 UMT PRAIRIE ISLAND NO. 1 DATE 12110/2002 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 5.
UNIT SHUTDOWNS AND POWER REDUCTIONS MOIITH NVEMBER 2002 DATE UNIT TYPE HOURS REASON METHOD LER NUMBER 1111512002 1
S 363.7 C
2 02-02 NOTES:
Refueling outage.
SYSTEM COMPONENT WA WA 4;,
TYPE F-FORCED S-SCHEDULED REASON A-EQUIPMENT FAILURE B-MAINTENANCE OR TEST C-REFUELING D-REGULATORY RESTRICTION E-OPERATOR TRAINING AND LICENSE EXAMINATION METHOD 1-MANUAL 2-MANUAL TRIP SYSTEM CODE DRAFT IEEE STD 800-1984(P805-D5) 3-AUTO TRIP 4-CONTINUED 5-REDUCED LOAD COMPONENT CODE 9-OTHER IEEE STD 803A-1983 F-ADMINISTRATIVE G-OPERATIONAL ERROR H-OTHER
NRC MONTHLY REPORT PRINTED 12/1012002 Page 4 DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 1211012002 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 NARRATiVM
SUMMARY
OF OPERATING EXPERIENCE MOWMNT: NOVE-MBER 2002 During the month of November, Unit 2 was base loaded. There were no shutdowns or power reductions.
T he
,.e no.or
'I "V -
-o CURRENT CONTINUOUS OPERATING RUN OF 273 DAYS
NRC MONTHLY REPORT PRINTED 12/1012002 Page 5 DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 12410/2002 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 OQPEMATI DAT REPORT OPERTING TAY0*S:" '
- 1. UNIT NAME:
PRAIRIE ISLAND NO. 2
,2. REPORTING PERIOD:
,NbVEMBER
- 2002
- 3. LICENSED THERMAL POWER (MWT): 1650 4., AEPLATE RATING (GROSS MWE):
593
- 5. DESIGN ELECTRICAL RATING (NET MWE): 536
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):
554
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):
522
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3-7) SINCE LAST REPORT, GIVE REASON:
NONE
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE):
NONE
- 10. REASONS FOR RESTRICTIONS. IF ANY:
NONE THIS MONTH YR-TO-DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD 720 8016 244966
- 12. NUMBER OF HOURS REACTOR CRITICAL 720.0 7362.1 217360.2
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1516.1
- 14. HOURS GENERATOR ON-LINE 720.0 7338.9 215667.5
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 1185883 11988670 345185468
- 17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 412780 4110190 113920570
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 393411 3889432 107723302
- 19. UNIT SERVICE FACTOR 1000 91.6 88.0
- 20. UNIT AVAILABILITY FACTOR 1000 91.6 88.0
- 21. UNIT CAPACITY FACTOR ( MDC NET) 104.7 93.0 87.0
- 22. UNIT CAPACITY FACTOR ( DER NET) 101.9 90.5 82.8
- 23. UNIT FORCED OUTAGE RATE 0.0 0.0 2.9
- 24. FORCED OUTAGE HOURS 0.0 0.0 6390.7
NRC MONTHLY REPORT PRINTED 12/1012002 Page 6 DOCKET NO. 50-306 UNIT PRAIRE ISLAND NO. 2 DATE 1211012002 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 UNIT SHUTDOWNS AND POWER REDUCTIONS MONTH: NjOEMBERg 2002 DATE UNIT TYPE 11/3012002 2
NIA NOTES: None.
TYPE F-FORCED S-SCHEDULED HOURS REASON METHOD LER NUMBER SYSTEM 0
N/A N/A REASON A-EQUIPMENT FAILURE B-MAINTENANCE OR TEST C-REFUELING D-REGULATORY RESTRICTION E-OPERATOR TRAINING AND LICENSE EXAMINATION METHOD SYSTEM CODE 1-MANUAL DRAFT IEEE STD 2-MANUAL TRIP 800-1984(P805-D5) 3-AUTO TRIP 4-CONTINUED 5-REDUCED LOAD COMPONENT CODE 9-OTHER IEEE STD 803A-1983 F-ADMINISTRATIVE G-OPERATIONAL ERROR H-OTHER COMPONENT N/A