ML023500458

From kanterella
Jump to navigation Jump to search

10 CFR 50.54 (Q) Report of Changes to OSTR Emergency Response Plan Which Do Not Decrease Effectiveness of Plan
ML023500458
Person / Time
Site: Oregon State University
(R-106)
Issue date: 12/03/2002
From: Klein A
Oregon State University
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML023500458 (3)


Text

RADIATION CENTER OREGON STATE UNIVERSITY 100 Radiation Center, Corvallis, Oregon 97331-5903 Telephone 541-737-2341 Fax 541-737-0480 December 3, 2002 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555

Reference:

Oregon State University TRIGA Reactor (OSTR),

Docket No. 50-243, License No. R-106

Subject:

10 CFR 50.54(q) Report of Changes to the OSTR Emergency Response Plan Which Do Not Decrease the Effectiveness of the Plan Gentlemen:

As a result of our annual review of the OSTR Emergency Response Plan, certain changes to the plan were determined to be necessary. This letter represents our formal report of the changes governed by 10 CFR 50.54(q). Based on our evaluation of these revisions, we have concluded that none of the specific changes in the attached enclosure reduces the plan's emergency response effectiveness.

All of the changes to the plan have been reviewed and approved by the OSTR Reactor Operations Committee and OSTR staff. In addition to the plan itself, a number of conforming changes were made to the Emergency Response Plan Implementing Procedures (ERIPs) in order to keep them up to date.

To make it easy to update your copy of the plan, a complete new copy will accompany this letter. If you have any concerns or questions about the reported changes to the OSTR Emergency Response Plan, please let me know. I declare under penalty of perjury that the foregoing is true and correct.

Yours sincerely, ew C. Klein Director cc:

Al Adams, U.S. Nuclear Regulatory Commission U

Lawrence Cohen, U.S. Nuclear Regulatory Commission A1 Craig Bassett, U.S. Nuclear Regulatory Commission David Stewart-Smith, Oregon Office of Energy

( )

John Ringle, Chairman, Reactor Operations Committee Steve Reese, Reactor Administrator

U. S. Nuclear Regulatory Commission Page 2 December 3, 2002 ENCLOSURE Oregon State University TRIGA Reactor (OSTR)

License No. R-106, Docket No. 50-243 Summary of changes to the OSTR ERP which were determined not to create a reduction in effectiveness in the plan

1. In sections 7.1.2.4 (page 7-2) and 7.3.2.2 (page 7-1 1), replace "These have detection ranges for gamma radiation between 1 mR h-and 10,000 mR h-1, with the two ARMs on the reactor top covering a range of 0.01 R h-' 1,000R h-1. Alarm set points for these ARMs are checked daily and are typically set between 20 mR h-1 and 100 mR h-1, except for the reactor top ARMs wich are typically set at 1 R h7l." With "These have detection ranges for gamma radiation between 0.1 - 10,000 mR h-'. Alarm set points for these ARMs are checked daily and are typically set between 20 mR h-' and 1000 mR h-'."
2. In section 10.1.b.e (page 10-1), add a superscripted "(1)" to the end of the sentence.
3. On table 5.1 (page 5-2) under the Emergency Action Levels, delete section (h) and replace section (i) with "An event which causes significant damage to the Radiation Center Complex."
4. On page E-0-1 of the ERIP under the Emergency Action Levels, replace section (h) with, "An event which causes significant damage to the Radiation Center Complex."
5. Delete page E-5-13 of the ERIP. The position no longer exists.
6. On page E-5-15 of the ERIP, replace "S.E. Binney" with "J.E. Darrough" and replace "S.

P. Smith" with "S.T. Keller".

7. On the Emergency Call List on page E-7-3 of the ERIP, add "S.T. Keller 541-753-6749" to the top of the list. Move S.R. Reese into the second slot and replace "S. E. Binney 541-752-5848" with the new Director.
8. On the Emergency Organization Mobilization Chart on page E-7-7 of the ERIP, add "S.T.

Keller" to the RAT team, replace "J.F. Higginbotham" with "R.C. Ringle" everywhere it appears, replace "J.C. Ringle" with "A.C. Klein" as the second choice for Chairman of the ROC, replace "A.C. Klein" with "W.H. Warnes" as the third choice for Chairman of the ROC, replace "M.R. Conrady" with "J.E. Darrough" and replace "S.E. Binney" with the new Director wherever it appears.

9. In ERIP 8, replace "Steve Binney" with the new Director wherever it appears and replace "Jack Higginbotham" with "John Ringle".

U. S. Nuclear Regulatory Commission Page 3 December 3, 2002

10. On page E-5-15 of the ERIP, replace the corridor monitor assignment table with the following:

CORRIDOR MONITOR l

_ALTERNATEl A

M.R. CONRADY S.C. CAMPBELL B

S.A. MENN J.E. DARROUGH C

J.M. STUEVE A.C. KLEIN D

I G.M. WACHS S.T. KELLER E

I K.A. HIGLEY D.M. HAMBY ATHRL I

J.T. GROOME C.E. GUNDERSO

11. On the Emergency Call List on page E-7-3 of the ERIP, replace "S. E. Binney 541-752-5848" with "A.C. Klein 541-758-5661".
12. On the Emergency Organization Mobilization Chart on page E-7-7 of the ERIP, replace "A.C. Klein" with "S. E. Binney" as the second choice for Chairman of the ROC, replace "S.E. Binney" with "A. C. Klein" as the Emergency Director first choice, Emergency coordinator third choice, and Public Information Officer third choice.
13. In ERIP 8, replace "Steve Binney" with "Andrew Klein" wherever it appears.

,