ML023250351

From kanterella
Jump to navigation Jump to search
Summary of Teleconference Between NRC & Nuclear Management Co. to Discuss Reactor Pressure Vessel Master Curve Evaluation Methodologies
ML023250351
Person / Time
Site: Point Beach  
Issue date: 11/19/2002
From: Henry A
NRC/NRR/DRIP/RLEP
To:
HENRY A, NRR/DRIP/RLEP, 301-415-1277
References
Download: ML023250351 (6)


Text

November 19, 2002 LICENSEE:

Nuclear Management Company FACILITY:

Point Beach Nuclear Plant, Units 1 and 2

SUBJECT:

SUMMARY

OF TELECONFERENCE BETWEEN THE NRC AND NUCLEAR MANAGEMENT COMPANY TO DISCUSS REACTOR PRESSURE VESSEL MASTER CURVE EVALUATION METHODOLOGIES The NRC staff and representatives of Nuclear Management Company (NMC) held a telephone conference on November 13, 2002, to discuss reactor pressure vessel Master Curve evaluation methodologies. This teleconference provided answers to questions raised by NMC during a September 17, 2002, meeting regarding the Point Beach Nuclear Plant (Point Beach), Units 1 and 2.

NMC inquired on the logistics for utilizing the BAW-2308 endorsed Master Curve methodology or the Kewaunee-approved Master Curve methodology to evaluate the Point Beach reactor pressure vessels. The NRC communicated that either methodology can be submitted for a potential 10 CFR Part 50 license amendment review or a potential 10 CFR Part 54 application.

With either methodology, the submission would need to request various exemptions similar to the Kewaunee application. The schedule for the potential submission was discussed. NMC noted that the Master Curve evaluation results included a potential core power increase.

A list of teleconference participants is provided in the enclosure. This summary has been shared with and reviewed by NMC.

/RA/

Alvin Henry, Project Manager License Renewal Section License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos: 50-266 and 50-301

Enclosure:

As stated cc w/encl: See next page

LICENSEE:

Nuclear Management Company FACILITY:

Point Beach Nuclear Plant, Units 1 and 2

SUBJECT:

SUMMARY

OF TELECONFERENCE BETWEEN THE NRC AND NUCLEAR MANAGEMENT COMPANY TO DISCUSS REACTOR PRESSURE VESSEL MASTER CURVE EVALUATION METHODOLOGIES The NRC staff and representatives of Nuclear Management Company (NMC) held a telephone conference on November 13, 2002, to discuss reactor pressure vessel Master Curve evaluation methodologies. This teleconference provided answers to questions raised by NMC during a September 17, 2002, meeting regarding the Point Beach Nuclear Plant (Point Beach), Units 1 and 2.

NMC inquired on the logistics for utilizing the BAW-2308 endorsed Master Curve methodology or the Kewaunee-approved Master Curve methodology to evaluate the Point Beach reactor pressure vessels. The NRC communicated that either methodology can be submitted for a potential 10 CFR Part 50 license amendment review or a potential 10 CFR Part 54 application.

With either methodology, the submission would need to request various exemptions similar to the Kewaunee application. The schedule for the potential submission was discussed. NMC noted that the Master Curve evaluation results included a potential core power increase.

A list of teleconference participants is provided in the enclosure. This summary has been shared with and reviewed by NMC.

/RA/

Alvin Henry, Project Manager License Renewal Section License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos: 50-266 and 50-301

Enclosure:

As stated cc w/encl: See next page DISTRIBUTION:

See next page Document Name: C:\\ORPCheckout\\FileNET\\ML023250351.wpd OFFICE LA:RLEP PM:RLEP DE SC:RLEP NAME HBerilla AHenry MMitchell SLee DATE 11/19/02 11/19/02 11/25/02 11/19 /02 OFFICIAL RECORD COPY

DISTRIBUTION: Telephone Conference with Nuclear Management Company, Dated: November 19, 2002 HARD COPY RLEP RF A. Henry E-MAIL:

PUBLIC J. Johnson W. Borchardt D. Matthews F. Gillespie RidsNrrDe R. Barrett E. Imbro G. Bagchi K. Manoly W. Bateman J. Calvo C. Holden P. Shemanski H. Nieh G. Holahan H. Walker S. Black B. Boger D. Thatcher G. Galletti C. Li J. Moore R. Weisman M. Mayfield A. Murphy W. McDowell S. Smith (srs3)

T. Kobetz R. Assa C. Munson RLEP Staff M. Mitchell

List of Telephone Conference Participants NRC Alvin Henry Matthew Mitchell NMC Roger Newton Brian Kemp Jim Knorr Framatone Ken Yoon Enclosure

Point Beach Nuclear Plant, Units 1 and 2 cc:

Mr. John H. ONeill, Jr.

Shaw, Pittman, Potts & Trowbridge 2300 N Street, NW Washington, DC 20037-1128 Mr. Richard R. Grigg President and Chief Operating Officer Wisconsin Electric Power Company 231 West Michigan Street Milwaukee, WI 53201 Site Licensing Manager Point Beach Nuclear Plant Nuclear Management Company, LLC 6610 Nuclear Road Two Rivers, WI 54241 Mr. Ken Duveneck Town Chairman Town of Two Creeks 13017 State Highway 42 Mishicot, WI 54228 Chairman Public Service Commission of Wisconsin P.O. Box 7854 Madison, WI 53707-7854 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351 Resident Inspector's Office U.S. Nuclear Regulatory Commission 6612 Nuclear Road Two Rivers, WI 54241 Ms. Sarah Jenkins Electric Division Public Service Commission of Wisconsin P.O. Box 7854 Madison, WI 53707-7854 Mr. Roy A. Anderson Executive Vice President and Chief Nuclear Officer Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 Nuclear Asset Manager Wisconsin Electric Power Company 231 West Michigan Street Milwaukee, WI 53201 Mr. Alan P. Nelson Nuclear Energy Institute 1776 I Street, N.W., Suite 400 Washington, DC 20006-3708 Mr. Fred J. Cayia Acting Site Vice President Point Beach Nuclear Plant Nuclear Management Company, LLC 6610 Nuclear Road Two Rivers, WI 54241 Manager, License Renewal Point Beach Nuclear Plant Nuclear Management Company, LLC 6610 Nuclear Road Two Rivers, WI 54241