PSEG Nuclear LLC P.O. Box 236, Hancocks Bndge, New Jersey 08038-0236 NOV, 2 20OZ UPSEG L
Nuclear LLC LRN-02-0394 United States Nuclear Regulatory Commission Document Control Desk Washington, DC' 20555 Gentleman:
REQUEST FOR ADDITIONAL INFORMATION INSERVICE INSPECTION PROGRAM RELIEF REQUEST SI-RR-B01 SALEM GENERATING STATION-UNIT I FACILITY OPERATING LICENSE DPR-70 DOCKET NOS. 50-272 By letter dated January 8, 2002, PSEG Nuclear LLC (PSEG) submitted two requests (S1-RR-B01 and S1-RR-C01) for relief from the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section X1, for Salem Generating Station, Unit No. 1 (Salem 1). The requests for relief are for the second 10-year inservice inspection (ISI) interval in which Salem adopted the 1983 Edition of ASME Section XI, including Summer 1983 Addenda, as the Code of record.
The Nuclear Regulatory Commission staff discussed the subject relief requests with PSEG staff on October 18, 2002. In response to the Nuclear Regulatory Commission's request, PSEG Nuclear is providing written clarification of the material composition and configuration of piping associated with the pressurizer relief and spray lines and steam generator nozzle to cast stainless steel elbows.
The Pressurizer relief and spray line 'nozzle to safe-end' welds 6-PR-1 104-1 (Summary No. 023400), 6-PR-1103-1 (Summary No. 024600), 4-PS-1131-29 (Summary No.
033500) and 4-PR-1100-1 (Summary No. 025900) do not contain Alloy 600 type material as evidenced by Attachment I drawing and information.
The Steam Generator nozzle-to-elbow welds 31-RC-1 130-2R1 (Summary No. 039200),
29-RC-1130-5R1 (Summary No. 050210), and 29-RC-1120-5R1 (052600) contain a single bead of Alloy 600 material located on the outside of the pipe. The Alloy 600 material is not in contact with the primary reactor water coolant located on the inside of the piping as evidenced by Attachment 2 drawing and information.
95-2168 REV. 7/99
Document Control Desk NOV 1 2 2002 LRN-01 -0433 Should you have any questions regarding this information, please contact Mr. Howard Berrick at 856-339-1862.
Sinc rely G. Salamo
/
Manager -
uclear Safety and Licensing
Attachment:
I.
Pressurizer Relief and Spray Lines Nozzle to safe-end Weld Configurations II.
Steam Generator Nozzle to Cast Stainless Steel Elbow Weld Configurations 2
SDocument Control Desk LRN-02-0394 NOV 12 2002 C
Mr. H. Miller Regional Administrator - Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 U.S. Nuclear Regulatory Commission ATTN: Mr. R. Fretz Licensing Project Manager - Salem Mail Stop 08B2 Washington DC 20555-001 USNRC Senior Resident Inspector - Salem (X24)
Mr. K. Tosch, Manager IV Bureau of Nuclear Engineering P. O. Box 415 Trenton, NJ 08625 3
Document Control Desk LRN-02-0394 Pressurizer Relief and Pressurizer Spray Lines Nozzle to Safe-end Weld Configurations I
mmý Is 0i:TSUR-L,7,gR A
'AiS XtJUENT S "At Of0fElpf CF illo O.CAWKS "OP11CIRY 11 f,'RhIANOR CWR(C Sv '-f 'A"PA OWS-Cm V OICS"ACI-OUSE tl.!e.lltc coppoWlax lpfo A idiot ImlAhc '0 Yýu 4 CIO OERItAt IRV cmsmlo 4140 W61(c, 10
.4( 9'ýLLCIN'-ý X.9VAN01116. COMOITIM LAO R(SIRIC1,10M 4c p(quissok Is olimrEc M ?U10SO list REFIlcoucc. 11APISMIT at olmost To twoutt Ygis mviv ot thy.4foxwArtax =mriitco INCICIR wtr0oul lm( ImEss wtillim OCAWISSICK of SLIC OEPLktmcgt IN LOVIOKL IC CORPORATION TAMPA DIVISION TAMPA, FLA A,.Vf.-ry it
( C C55 po SAig,"
- O=jft Avo.1.4 IPA - 7P-?16 ic 4,
AA4140 AVZ Z49 IT A/
1460 O.D.
074
'Alt xcu" I 11 tml mots" v 840 cwAlol mmirmy
'411mial'am onto IT fill Pimps 01VISION
- 1 *13TIVJ04t ano IS mw &Val"( to you umon A COWICCATIAL litAtIONINIP ARC %yj)tCj 10 -%( jOkXjMg INO IM11clion me Ofoululan CUNIO TO punism Us( itnowl. 'basull -% 3ITMO:1 r
to LACINts rVIS XCO(If U AXT.1111041"1100 :Ufalva fX(Ills WIDMI IN(
UPIFU OTT(v Kftisslom v U19 AOVINCC log I
ISSUEO
- 350905, F
41.0%
-7usamas-sLgjJvmQ 92WT-NIL"W Jae-rjkLv
Document Control Desk LRN-02-0394 Steam Generator Nozzle to Cast Stainless Steel Elbow Weld Configurations I
-NCL wet.
IBA Alo zZ, S4Z.,
I " S/e *,&P4,A I.uT PR/M,
/ -ZZL C, The new welds consists of SA 216 Gr WCC cast nozzle. Inconcl weld bnd 308L o14 weld from the hydro cap welded at Seabrook, 308L nArrow groove weld, v-t*u*u, thicknesses of old weld consisting of ER 316 root and E16-8-2 lur the rcnmuidu oii ill,
,oNCL weld deposit welded to the cas elbow A351 CF8M The actuAl width ot the nlia, ih groove weld is 375, which has a cap weld of ER 308L, bridging the trAnibtiliaw
,ii the nozzle and the elbow, measring an average of I 025" wide EK309L WUELD FlaUc SA
- ,iW Cr W*e_
INT C-FtST
\\ ý6__L Fusiotj LNIE
-V c,457' £Lj6Otb A-51 C ý3" 3,
l'2oco-o 9, "'0
- o BL L u
Q-0ts oC-o%
O(,s 3T /2 n
r-4 A
Il-V&'*
-V,
\\3J I
V\\O d
I