E-mail from B. Mccabe to J. Craig and S. Rosenberg, October 31st Note Regarding CRDM Cracking
ML023030506
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 11/05/2002
From: Mccabe B
NRC/OCM
To: Jocelyn Craig, Rosenberg S
NRC/EDO
Banerjee, M. NRR/DLPM/LPD3-2, 415-2277
References
Download: ML023030506 (1)


Text

LM~~~

~

6T c618-03 71

~fT~i

~~

Pae 1 From:

Brian McCabe To:

John Craig; St~cey Rosenberg Date:

11/5/01 9"53AM

Subject:

October 31st Note Regarding CRDM Cracking John Good morning. I have a few questions for the staff regarding your 10/31 note to the TAs.

1. For Davis Besse, the staff indicates that it plans to issue its technical assessment by 11/5. When that happens, could you forward that up to the TAs?
2. (Davis Besse) How will the staffs technical assessment due on 11/5 differ from their assessment that formed the basis for the 18 month deadline?
3. Will the staff provide the licensee with time to review the staffs technical assessment for potential errors or misunderstandings?
4.

For Davis Besse, when does the staff anticipate it will receive the licensee's responses to the RAWs?

5. The Surry 2 writeup seems to imply that discussions are over and the staff intends to pursue an Order.

Is that correct?

6. I'm not sure of the bottom line for D.C. Cook? What is the staffs intention for D.C. Cook?
7. Are DC Cook, Surry 2, and Davis Besse the only plants in play right now for Orders? Over what period of time would discussions with plants in the red category of the moderate susceptibility table play out?

What regulatory tool does staff intend to use if these licensees do not correct their "unacceptable response"?

8. When does the staff intend to forward Orders/formal plans to the Commission for review?

Thanks I know the staff is very busy, so I don't need a formal response to my Qs. An email response would be great. I have cc'd the other TAs so that they get the same information I am provided.

Thanks again.

Brian James Beall, Joseph Shea; Michael Tschiltz; Rick Croteau; Thomas Hiltz CC: