ML023030492
| ML023030492 | |
| Person / Time | |
|---|---|
| Site: | Davis Besse (NPF-003) |
| Issue date: | 03/29/2002 |
| From: | Ho Nieh NRC/EDO |
| To: | Beall J, Beecher W, Collins S, Croteau R, Hiltz T, Jerrica Johnson, Kane W, Kerri Kavanagh, Mccabe B, Portner L, Rathbun D, Sharkey J, James Shea, Sheron B, Travers W, Tschiltz M, Uhle J NRC/EDO, NRC/OCM, Office of Public Affairs |
| Banerjee, M. NRR/DLPM/LPD3-2, 415-2277 | |
| References | |
| Download: ML023030492 (1) | |
Text
r5pr~ei Robb fst -F~F~ftE~
~Bri~
From:
Thomas Hiltz To:
Alan Levin, Bradley Jones; Brian McCabe; Darrell Roberts; David Gamberoni; James Beall, Jeffry Sharkey; Joseph Shea; Ken Hart; Michael Tschiltz; Rick Croteau; Stacey Rosenberg; Sunil Weerakkody Date:
10/5/01 10:46AM
Subject:
First Energy Brief FirstEnergy (Davis-Besse) reps called me this morning to discuss their perspectives on CRDM penetration cracking. They are scheduled to come in next Thursday to meet with our office. If other offices are interested, I recommend that we schedule a TA brief. They are flexible and will conduct two briefings if there are schedule conflicts. They have also indicated that they would not object if an EDO rep sat in on the briefing.
We are scheduled for 10 am next Thursday. Please let me know if you are interested and if so, whether 10 am works
- Thanks, Tom