October 16, 2002 Mr. Gary Smith Grand Gulf Nuclear Station Entergy Operations Bald Hill Road Port Gibson, MS 39150

Dear Mr. Smith:

Per your request, enclosed is a compact disk containing the Level 1, Revision 3 Standardized Plant Analysis Risk (SPAR) model for Grand Gulf and the SAPHIRE 6.75 suite of probabilistic risk assessment (PRA) computer codes. Also enclosed is a copy of the users manual for the Grand Gulf SPAR model. The SAPHIRE code suite is required to perform analyses with the Revision 3 SPAR model. Both of these software packages are in the form of executable files that can be run directly from the compact disk. These items are for your organizations use only and are not to be distributed further without the consent of the NRC. Also please note that the information contained in the SPAR model is considered sensitive and should be treated accordingly.

The Revision 3 SPAR model for Grand Gulf has been reviewed with your PRA staff and benchmarked against your PRA model for the plant. Subsequent to this review and benchmarking, the SPAR model:

(1) was revised to address comments and issues identified during the review, (2) now yields results which are in reasonable agreement with those produced by your PRA model, and (3) has no associated outstanding modeling issues. For these reasons, we are certifying that the Grand Gulf SPAR model meets all Revision 3 SPAR model quality assurance (QA) criteria and is therefore acceptable for unrestricted use by your staff analysts. Although the Revision 3 SPAR models are certified as acceptable for unrestricted use, nevertheless, we advise analysts to understand the inputs and assumptions inherent in the models and to apply model results giving them due consideration. The Revision 3 SPAR models have been designed to capture the significant risk contributors associated with internal event initiators for plants operating at full power. Therefore, these models may not provide the level of detail necessary to capture the risk from the less significant contributors. Thus, for a particular application, the analyst may obtain results that do not appear to be reasonable.

In addition, the software for the LP/SD SPAR model for Grand Gulf is provided to facilitate the onsite QA review of this model with your PRA staff and the Benchmarking of the model against your LP/SD PRA model for the plant, which will be scheduled at your convenience. The LP/SD model is considered interim, and should be used by your staff analysts with appropriate discretion.

Questions about the Revision 3 SPAR model should be directed to Mr. Robert Buell of the Idaho National Engineering and Environmental Laboratory (INEEL) at (208) 526-9400 (buelrf@inel.gov).

Question about the LP/SD SPAR model should be directed to Mr. William Galyean, INEEL, at

G. Smith 2

(208) 526-0627 (wgj@inel.gov). Questions about the SAPHIRE code suite should be directed to Mr.

Ted Wood, INEEL, at (208) 526-8729 (stw@inel.gov). Comments and suggestions may also be directed to either of these gentlemen or to Dr. Patrick OReilly, NRC project manager for SPAR model development, at (301) 415-7570 (pdo@nrc.gov).

If you are interested in receiving on-going technical support for SAPHIRE, you are invited to join the SAPHIRE Users Group. Mr. John Schroeder, INEEL, at (208) 526-8755 (roe@inel.gov) can provide more details about the group and the services offered.

Due to the potential sensitivity of the information contained in the Enclosures, they are not publicly available.

Sincerely, Original Signed By Scott F. Newberry, Director Division of Risk Analysis and Applications Office of Nuclear Regulatory Research

Enclosures:

As stated cc: D. Jaffe, NRR/LPD4-1 (w/o enclosures)

G. Smith 2

(208) 526-0627 (wgj@inel.gov). Questions about the SAPHIRE code suite should be directed to Mr.

Ted Wood, INEEL, at (208) 526-8729 (stw@inel.gov). Comments and suggestions may also be directed to either of these gentlemen or to Dr. Patrick OReilly, NRC project manager for SPAR model development, at (301) 415-7570 (pdo@nrc.gov).

If you are interested in receiving on-going technical support for SAPHIRE, you are invited to join the SAPHIRE Users Group. Mr. John Schroeder, INEEL, at (208) 526-8755 (roe@inel.gov) can provide more details about the group and the services offered.

Due to the potential sensitivity of the information contained in the Enclosures, they are not publicly available.

Sincerely, Original Signed By Scott F. Newberry, Director Division of Risk Analysis and Applications Office of Nuclear Regulatory Research

Enclosures:

As stated cc: D. Jaffe, NRR/LPD4-1 (w/o enclosures)

Distribution w/o enclosures:

OERAB RF PWilson, NRR DRAA RF CCarpenter, NRR File Center DCoe, NRR Public RGramm, NRR JStrosnider/AThadani, RES AHowell, RGN-IV DMarksberry, RES TPruett, RGN-IV (SRA)

WRuland, NRR Dloveless, RGN-IV (SRA)

MJohnson, NRR THoeg (SRI)

DOCUMENT NAME: C:\\GRANDGULFLTR.WPD To receive a copy of this document, indicate in the box C = Copy wo/encl E = Copy w/encl N = No copy OFFICE OERAB E

OERAB E

OERAB C

OERAB C

DRAA C

NAME EGoldfeiz*

POReilly*

MCheok*

PBaranowsky*

SNewberry*

DATE 10/10/02 10/10/02 10/16/02 10/16/02 10/16/02 OFFICIAL RECORD COPY OAR in ADAMS (Y or N)?

Y Publicly Available (Y or N)?

Y Template No.: RES-006 Accession No.: ML022900541 Res File Code: 2C-3

ROUTING AND TRANSMITTAL SLIP Date 10/10/2002 TO: (Name, office symbol, room #, building, agency/post)

Initials Date

1. Eli Goldfeiz - Concur - Fill in Y or N for OAR in ADAMS and Publicly Available EBG 10/10/02
2. Pat OReilly - Concur PDO 10/10/02
3. Mike Cheok - Concur MCC 10/16/02
4. Pat Baranowsky - Concur MCC for PWB 10/16/02
5. Scott Newberry - Signature SFN 10/16/02
6. Nancy - Distribute - Fill in Template Number, Accession Number and RES Code Number NLL 10/16/02
7.

8.

9.

10.

Action File Note and Return Approval For Clearance Per Conversation As Requested For Correction Prepare Reply Circulate For Your Information See Me Comment Investigate X

Concurrence/Signature Coordination Justify REMARKS Letter to Mr. G. Smith - Per your request, enclosed is a compact disk containing the Level 1, Revision 3i Standardized Plant Analysis Risk (SPAR) model for Grand Gulf and the SAPHIRE 6.75 suite of probabilistic risk assessment (PRA) computer codes. Also enclosed is a copy of the users manual for the Grand Gulf SPAR model.

FROM: (Name, org. symbol, Agency/Post)

Room # - Bldg.

Phone #