The University of New Mexico Chemical & Nuclear Engineering 203 Farris Engineering Center Albuquerque, NM 87131-1341 Telephone (505)277-5431 FAX (505) 277-5433 September 30, 2002 Marvin M. Mendoca Senior Project Manager Non-Power Reactors and Decommissioning Project Directorate Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington D.C.
20555-0001 Dear Mr. Mendoca; Enclosed is the 2002 Annual Report for the AGN-201M reactor located at the University of New Mexico - Docket 50-252.
Sincerely, Robert D. Busch, Ph.D, P.E.
Chief Reactor Supervisor cc:
Document Control Desk, USNRC Norman F. Roderick, Ph.D.
Reactor Administrator
REPORT ON FACILITY LICENSE NO. R-102 THE UNIVERSITY OF NEW MEXICO JULY 1, 2001 - JUNE 30,2002 The University of New Mexico's AGN-201M reactor was used for some research during the 2001-2002. This was a continuation of the research from the previous year and involved subcritical multiplication and die-away measurements at power level below 1 microWatt. There were no ch-ngesin facility-desigb, -pfrm ah*'*-ca~ c-tEigtic-s, o-r-dpe'ratihg procedur-es reh-ii'd -TTheaiofor safety during the reporting period. The NRC did an on-site review of the facility in October 2001 and found one violation on security alarm testing. This has been remedied.
The AGN-201M Reactor Facility is an essential part of our educational program, including public education, and continues to serve us well. The use of the reactor from July of 2001 through June of 2002 was as follows:
I -Teaching -
31 2-During the period, we were shutdown for security from September 11, 2001 through September 18, 2001. From that period on, we did not use the reactor until mid-November as there were no pressing experiments that needed to be run, and it was easier to maintain security with no access. In the summer of 2001, the startup source drive failed and manual insertion/removal of the source was required. A new source drive was purchased and installed in December 2001 and tested. There was no effect on reactor performance. During the annual maintenance in August 2001, the replaced aluminum can containing the detector for channel #1 was re-inspected and found to have some corrosion. The other cans appeared to be in good condition. A new can for detector #1 (not a safety channel) was fabricated from 1-inch PVC and put in the water tank. The presence of chlorine in the PVC reduced the Channel 1 startup count rate by 50%, but did not affect the performance of the reactor. All detector cans will be inspected again as part of the 2002 annual maintenance.
Type of Use July 01 - June 02 July 01 - June 02 Hours Watt-hours Class Demonstrations 0.8 2.4 Faculty Research 3.0 0.0 Graduate Student Research 0.0 0.0 Maintenance and Equipment Check 14.0 15.0 Operator Training and Requalification 8.5 22.5 Totals for the Year 54.5 108.8
C, Agn-201 01-02 Report, Page 2 Other than the new Channel 1 can and the new source drive, there were no changes to the facility as it is described in the application for license and amendments thereto, nor were there any changes to the procedures as described in Facility Technical Specifications. No new experiments were performed during the reporting period.
There were no 10 CFR 50.59 issues during the reporting period. During the reporting period, there was no liquid radioactive waste released from the facility nor was there any solid waste released. There were no environmental radiation surveys performed outside the facility. All personnel exposures received during the reporting period were below 50 mrem per person with the majority of personnel receiving below 5 mrem. No facility visitors received measurable exposures.
Di7Rodri~kw' x'ih-e i n--tiim--h-ir -d*ringtliis r"-eFiing-ri*d.-'A permanent hliairm-n-for the Department has been named and starts mid August 2002.. The current personnel assignments are:
Dean, College of Engineering Joseph Cecchi Interim Chairman, Department of Chemical and Nuclear Engineering Norman F. Roderick Reactor Administrator Norman F. Roderick Chief Reactor Supervisor Robert D. Busch USNRC-licensed Senior Reactor Operators Robert D. Busch Ken Carpenter Gary Cooper The current makeup of the Reactor Safety Advisory Committee is:
Jafm--fis-B *iso6 Robert Jefferson Ron Knief Robert Long Ted Schmidt David Summers with no vacant position although Ted Schmidt has retired from Sandia and will soon be retiring from the committee.
AGN-201 01-02 Report, Page 3 The University of New Mexico's AGN-201M reactor continues to be used extensively for teaching experiments as a part of our undergraduate and graduate programs. These experiments include approach-to-critical, reactor period and reactivity measurements, importance functions measurements, sample activation, control rod calibrations, and reactor power and neutron fluence measurements. The reactor is also used throughout the Fall, Spring and Summer sessions of the University. All experiments have received prior approval from our Reactor Safety Advisory Committee.
Norman F. Roderic_
Reacto'r Administrator