VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 February 4, 2002 United States Nuclear Regulatory Commission Serial No.:

02-065 Attention: Document Control Desk NLOS/mm Washington, DC 20555-0001 Docket Nos.:

50-338/339 License Nos.:

NPF-4/7 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY (DOMINION)

NORTH ANNA POWER STATION UNITS I AND 2 EMERGENCY RESPONSE DATA SYSTEM DATABASE UPDATES Modifications to four Emergency Response Data System (ERDS) points have been implemented at North Anna Power Station as a result of replacement of the process vent radiation monitors. The radiation monitors are common to both units. (The replacements were a result of a North Anna Design Change Package.) The changes are detailed in the Data Point Library (DPL) reference file forms provided in Attachments 1 and 2. Attachment 3 provides the revision summary (change report) for the affected points.

No new commitments are intended by this letter.

If you have any questions concerning these results, please contact us.

Very truly yours, S. P. Sarver Director - Nuclear Licensing and Operations Support Attachments

1. North Anna Unit 1 Updated Data Point Library Sheets
2. North Anna Unit 2 Updated Data Point Library Sheets
3. Revision Summary

cc:

U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth St., SW, Suite 23 T85 Atlanta, GA 30303-8931 Mr. M. J. Morgan NRC Senior Resident Inspector North Anna Power Station Ms. K. Lynne Saul, Program Manager (diskette enclosed)

Engineering, Scientific, & Management Services Scientech, Inc.

440 West Broadway Idaho Falls, ID 83402

ATTACHMENT 1 NORTH ANNA UNIT 1 UPDATED DATA POINT LIBRARY SHEETS

PRINTED 01/24/2002 STATION: North Anna UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERIC/COND DESC:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SETPOINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

01/24/2002 NAl N/A EFF GAS RAD R3RM223C PV HIGH RADN RATE MONITOR RADIOACTIVITY OF RELEASED GASES A

UCI/S N/A 1E+2 1.OE+11 N/A N/A P

I EXPONENTIATED VALUE OF LOGARITHMIC INPUT SERV BLDG ELEV 307 VARIABLE N/A N/A N/A N/A Takes a sample from stacks A & B and measures the radiation level in the sample.

This is the high range instrument for this data.

PRINTED 01/24/2002 STATION: North Anna UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERIC/COND DESC:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SETPOINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

01/24/2002 NAl N/A EFF GAS RAD R3RM224C PV NORM RADN RATE MONITOR RADIOACTIVITY OF RELEASED GASES A

UCI/S N/A 1.OE-2 1.0E+5 N/A N/A P

1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SWGR BLDG ELEV 307 VARIABLE N/A N/A N/A N/A Continually senses radiation level in a sample stream from the process vent and provides a signal to RM-GW-108-1A's micro computer for determination of radiation release rate.

This is the normal range instrument for this data.

PRINTED 01/24/2002 STATION: North Anna UNIT: I PWR DATA POINT LIBRARY REFERENCE FILE DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERIC/COND DESC:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SETPOINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

01/24/2002 NAI N/A EFF GAS RAD R3RM225C PV NORMAL RAD MON RADIOACTIVITY OF RELEASED GASES A

UCI/CC N/A 1.OE-7 1.OE-2 N/A N/A P

1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SWGR BLDG ELEV 307 VARIABLE N/A N/A N/A N/A Continually senses radiation level in a sample stream from the process vent.

This is the normal range instrument for this data.

STATION: North Anna UNIT:

1 PWR DATA POINT LIBRARY REFERENCE FILE DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERIC/COND DESC:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SETPOINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

01/24/2002 NAl N/A EFF GAS PAD R3RM234C PV HIGH RADIATION MONITOR RADIOACTIVITY OF RELEASED GASES A

UCI/CC N/A 1.OE-4 1.OE+5 N/A N/A P

1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SERV BLDG ELEV 307 VARIABLE N/A N/A N/A N/A Senses radiation level in a sample stream from the process vent.

This is the high range instrument for this data.

PRINTED 01/24/2002

ATTACHMENT 2 NORTH ANNA UNIT 2 UPDATED DATA POINT LIBRARY SHEETS

STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERIC/COND DESC:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SETPOINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

01/24/2002 NA2 N/A EFF GAS RAD R3RM223C PV HIGH RADN RATE MONITOR RADIOACTIVITY OF RELEASED GASES A

UCI/S N/A 1E+2 1.OE+II N/A N/A 1

EXPONENTIATED VALUE OF LOGARITHMIC INPUT SERV BLDG ELEV 307 VARIABLE N/A N/A N/A N/A Takes a sample from stacks A & B and measures the radiation level in the sample.

This is the high range instrument for this data.

PRINTED 01/24/2002

STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERIC/COND DESC:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SETPOINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

01/24/2002 NA2 N/A EFF GAS RAD R3RM224C PV NORM RADN RATE MONITOR RADIOACTIVITY OF RELEASED GASES A

UCI/S N/A 1.OE-2 1.OE+5 N/A N/A P

1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SWGR BLDG ELEV 307 VARIABLE N/A N/A N/A N/A Continually senses radiation level in a sample stream from the process vent and provides a signal to RM-GW-108-1A's micro computer for determination of radiation release rate.

This is the normal range instrument for this data.

PRINTED 01/24/2002

STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERIC/COND DESC:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SETPOINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

O1I24/2002 NA2 N/A EFF GAS RAD R3RM225C PV NORMAL RAD MON RADIOACTIVITY OF RELEASED GASES A

UCI/CC N/A 1.OE-7 1.OE-2 N/A N/A P

1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SWGR BLDG ELEV 307 VARIABLE N/A N/A N/A N/A Continually senses radiation level in a sample stream from the process vent.

This is the normal range instrument for this data.

PRINTED 01/24/2002

STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC:

GENERIC/COND DESC:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SETPOINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC:

01/24/2002 NA2 N/A EFF GAS RAD R3RM234C PV HIGH RADIATION MONITOR RADIOACTIVITY OF RELEASED GASES A

UCI/CC N/A 1.OE-4 1.OE+5 N/A N/A P

1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SERV BLDG ELEV 307 VARIABLE N/A N/A N/A N/A Senses radiation level in a sample stream from the process vent.

This is the high range instrument for this data.

PRINTED 01/24/2002

ATTACHMENT 3 REVISION

SUMMARY

Page No.

1 CHANGED POINT R3RM223C DATE:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

PRINTED 01/24/2002 STATION: North Anna UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT AT 10:03 ON 01/24/2002.

CHANGES WERE AS FOLLOWS:

WAS: 03/21/1991 IS: 01/24/2002 WAS: 1.259E+5 IS: IE+2 WAS: 1.0E+13 IS: 1.OE+l1

Page No.

2 PRINTED 01/24/2002 STATION: North Anna UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT R3RM224C AT 10:04 ON 01/24/2002.

CHANGES WERE AS FOLLOWS:

DATE:

MAXIMUM INSTR RANGE:

WAS: 03/21/1991 IS: 01/24/2002 WAS: 1.0E+6 IS: 1.0E+5

Page No.

STATION: North Anna PRINTED UNIT: 1 01/24/2002 PWR DATA POINT LIBRARY REFEPENCE FILIE CHANG" REVORT CHANGED POINT R3RM225C AT 10:05 ON 01/24/2002.

CHANGES WERE AS FOLLOWS:

DATE:

WAS: 03/21/1991 IS: 01/24/2002 MAXIMUM INSTR RANGE:

WAS: 10.0 IS: 1.0E-2

Page No.

4 STATION: North Anna PRINTED UNIT: 1 01/24/2002 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT R3RM234C AT 10:07 ON 01/24/2002.

CHANGES WERE AS FOLLOWS:

DATE:

WAS: 03/21/1991 Is: 01/24/2002 MINIMUM INSTR RANGE:

WAS: 3.162E-4 IS: 1.OE-4

STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT R3RM223C DATE:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

AT 10:03 ON 01/24/2002.

CHANGES WERE AS FOLLOWS:

WAS: 03/21/1991 IS: 01/24/2002 WAS: 1.259E+5 IS: IE+2 WAS: 1.0E+13 IS: 1.OE+II PRINTED 01/24/2002 Page No.

Page No.

2 STATION: North Anna PRINTED UNIT: 2 01/24/2002 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT R3RM224C AT 10:04 ON 01/24/2002.

CHANGES WERE AS FOLLOWS:

DATE:

WAS: 03/21/1991 IS: 01/24/2002 MAXIMUM INSTR RANGE:

WAS: 1.OE+6 IS-1.OE+5

Page No.

3 STATION: North Anna PRINTED UNIT: 2 01/24/2002 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT R3RM225C AT 10:05 ON 01/24/2002.

CHANGES WERE AS FOLLOWS:

DATE:

WAS: 03/21/1991 IS: 01/24/2002 MAXIMUM INSTR RANGE:

WAS: 10.0 IS: 1.OE-2

Page No.

4 STATION: North Anna PRINTED UNIT: 2 01/24/2002 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT R3RM234C AT 10:07 ON 01/24/2002.

CHANGES WERE AS FOLLOWS:

DATE:

WAS: 03/21/1991 IS: 01/24/2002 MINIMUM INSTR RANGE:

WAS: 3.162E-4 IS: 1.OE-4