L-02-085, July 2002 Monthly Operating Report for Beaver Valley Units 1 & 2
ML022270602 | |
Person / Time | |
---|---|
Site: | Beaver Valley |
Issue date: | 08/07/2002 |
From: | Bezilla M FirstEnergy Nuclear Operating Co |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
GL-97-002, L-02-085 | |
Download: ML022270602 (5) | |
Text
FENOC Beaver Valley Power Station P. 0. Box 4 Shippingport,PA 15077 L-02-085 August 7, 2002 Beaver Valley Power Station Unit 1 - Docket No. 50-334, License No. DPR-66 Unit 2 - Docket No. 50-412, License No. NPF-73 Monthly Operating Report U. S. Nuclear Regulatory Conunission Document Control Desk Washington, DC 20555 Gentlemen:
In accordance with NRC Generic Letter 97-02, "Revised Contents of the Monthly Operating Report", and Unit 1 and 2 Technical Specification 6.9.4, the "Monthly Operating Report" is submitted for Unit 1 and Unit 2 for the month of July 2002.
Respectfully, M. B. Bezilla Vice-President DTJ/caj Enclosures cc: NRC Regional Office King of Prussia, PA
UNIT SHUTDOWNS DOCKET NO. 50-334 UNIT NAME BVPS Unit #1 DATE August 1, 2002 COMPLETED BY David T. Jones TELEPHONE (724) 682-4962 REPORTING PERIOD: July 2002 No. Date Type Duration Reason Method of Cause / Corrective Actions (Y/M/D) F: Forced (Hours) (1) Shutting S: Scheduled Down (2) Comments NONE (1) Reason (2) Method A - Equipment Failure (Explain) 1 - Manual B - Maintenance or Test 2 - Manual Trip / Scram C - Refueling 3 - Automatic Trip / Scram D - Regulatory Restriction 4 - Continuation E - Operator Training / Ucense Examination 5 - Other (Explain)
F - Administrative G - Operational Error (Explain)
H - Other (Explain)
SUMMARY
The Unit operated at a nominal value of 100% output for the entire report period.
OPERATING DATA REPORT DOC*ET 10. : 50-334 UNIT NAME: rVPS UNIT #1 REPORT DATE: 08/01/02 COMPLETED BY: DAVID T. JONES TELEPHONE: (724) 682-4962 ffg&*l: Rated thermal power at
- la. REPORTING PERIOD: JULY 2002
- Bws-1 was uprated from 2652 uit*
to 2689 M*t on 10/20/01. Net *
- 1. DESIGN ELECTRICAL RATING (Net Mie): 835
- DC wa also uprated from
- 810 lWe to 821 MWe. *
- 2. Mime): 821 MAX. DPZENDABLZ CAPACITY (Net * * ** * * * ** *1 * *V * *t *b
- THIS MONTH YEAR TO DATE CUMULATIVE 744.0 5087.0 230111.0 3a. HOURS IN REPORTING PERIOD:
744.0 5087.0 157168.5
- 3. NO. OF HRS. REACTOR WAS CRITICAL:
744.0 5087.0 154708.9
- 4. SERVICE HOURS GENERATOR ON LINE:
0.0 0.0 0.0
- 5. UNIT RESERVE SHUTDOWN HOURS:
606770.0 4185640.0 115851783.0
- 6. NET ELECTRICAL ENERGY GEN. (MKE):
643340.0 4430860.0 123697646.0
- 7. GROSS ELECT. ENERGY GEN. (MWH):
1997832.0 13548211.0 381183016.5
- 8. GROSS THERL ENERGY N. (KWH):
100.0 100.0 68.7
- 9. UNIT AVAILABILITY FACTOR (M):
100.2 64.0 99.3
- 10. UNIT CAPACITY FACTOR (MDC) (M):
0.0 0.0 16.0
- 11. UNIT FORCED OUTAGE RATE (M):
UNIT SHUTDOWNS DOCKET NO. 50-412 UNIT NAME BVPS Unit #2 DATE August 1, 2002 COMPLETED BY David T. Jones TELEPHONE (724) 682-4962 REPORTING PERIOD: July 2002 No. Date Type Duration Reason Method of Cause / Corrective Actions (YIMID) F: Forced (Hours) (1) Shutting S: Scheduled Down (2) Comments NONE (1) Reason (2) Method A - Equipment Failure (Explain) 1 - Manual B- Maintenance or Test 2 - Manual Trip / Scram C- Refueling 3 - Automatic Trip I Scram D- Regulatory Restriction 4 - Continuation E- Operator Training / Ucense Examination 5 - Other (Explain)
F - Administrative G - Operational Error (Explain)
H - Other (Explain)
SUMMARY
The Unit operated at a nominal value of 100% output for the entire report period.
OPERATING DATA REPORT DOCKET NO.: 50-412 UNIT NAME: BVPS UNIT #2 REPORT DATE: 08/01/02 COMPLETED BY: DAVID T. JONES TELEPHONE: (724) 682-4962
- Noeta: Rated thermal power at
- la. REPORTING PERIOD: JULY 2002
- BVPS-2 was uprated from 2652 MWt*
- to 2689 Mwt on 10/30/01. Net *
- 1. DESIGN ELECTRICAL RATING (Net MV.): 836
- MDC was also uprated from
- 831
- 820 MVe to 831 MEe. *
- 2. MAX. DEPENDABLE CAPACITY (Net MO): * * * * * * * * * * * * * * * * *
- THIS MONTE YEAR TO DATE CUMULATIVE 744.0 5087.0 128894.0 3a. HOURS IN REPORTING PERIOD:
744.0 4527.6 105882.1
- 3. NO. OF ERS. REACTOR WAS CRITICAL:
744.0 4460.9 105153.5
- 4. SERVICE HOURS GENERATOR ON LINE:
0.0 0.0 0.0
- 5. UNIT RESERVE SHUTDOWN HOURS:
614578.0 3570459.0 82148551.0
- 6. NET ELECTRICAL ENERGY GEN. (MWE):
647267.0 3768654.0 86843397.0
- 7. GROSS ELECT. ENERGY GEN. (MWE):
11474467.0 264882048.0 1997512.0
- a. GROSS THERMAL ENERGY GEN. (MUE):
87.7 81.6 100.0
- 9. UNIT AVAILABILITY FACTOR (M):
84.5 77.1 99.4
- 10. UNIT CAPACITY FACTOR (MDC) (M):
0.4 10.1 0.0
- 11. UNIT FORCED OUTAGE RATE (M):
Text
FENOC Beaver Valley Power Station P. 0. Box 4 Shippingport,PA 15077 L-02-085 August 7, 2002 Beaver Valley Power Station Unit 1 - Docket No. 50-334, License No. DPR-66 Unit 2 - Docket No. 50-412, License No. NPF-73 Monthly Operating Report U. S. Nuclear Regulatory Conunission Document Control Desk Washington, DC 20555 Gentlemen:
In accordance with NRC Generic Letter 97-02, "Revised Contents of the Monthly Operating Report", and Unit 1 and 2 Technical Specification 6.9.4, the "Monthly Operating Report" is submitted for Unit 1 and Unit 2 for the month of July 2002.
Respectfully, M. B. Bezilla Vice-President DTJ/caj Enclosures cc: NRC Regional Office King of Prussia, PA
UNIT SHUTDOWNS DOCKET NO. 50-334 UNIT NAME BVPS Unit #1 DATE August 1, 2002 COMPLETED BY David T. Jones TELEPHONE (724) 682-4962 REPORTING PERIOD: July 2002 No. Date Type Duration Reason Method of Cause / Corrective Actions (Y/M/D) F: Forced (Hours) (1) Shutting S: Scheduled Down (2) Comments NONE (1) Reason (2) Method A - Equipment Failure (Explain) 1 - Manual B - Maintenance or Test 2 - Manual Trip / Scram C - Refueling 3 - Automatic Trip / Scram D - Regulatory Restriction 4 - Continuation E - Operator Training / Ucense Examination 5 - Other (Explain)
F - Administrative G - Operational Error (Explain)
H - Other (Explain)
SUMMARY
The Unit operated at a nominal value of 100% output for the entire report period.
OPERATING DATA REPORT DOC*ET 10. : 50-334 UNIT NAME: rVPS UNIT #1 REPORT DATE: 08/01/02 COMPLETED BY: DAVID T. JONES TELEPHONE: (724) 682-4962 ffg&*l: Rated thermal power at
- la. REPORTING PERIOD: JULY 2002
- Bws-1 was uprated from 2652 uit*
to 2689 M*t on 10/20/01. Net *
- 1. DESIGN ELECTRICAL RATING (Net Mie): 835
- DC wa also uprated from
- 810 lWe to 821 MWe. *
- 2. Mime): 821 MAX. DPZENDABLZ CAPACITY (Net * * ** * * * ** *1 * *V * *t *b
- THIS MONTH YEAR TO DATE CUMULATIVE 744.0 5087.0 230111.0 3a. HOURS IN REPORTING PERIOD:
744.0 5087.0 157168.5
- 3. NO. OF HRS. REACTOR WAS CRITICAL:
744.0 5087.0 154708.9
- 4. SERVICE HOURS GENERATOR ON LINE:
0.0 0.0 0.0
- 5. UNIT RESERVE SHUTDOWN HOURS:
606770.0 4185640.0 115851783.0
- 6. NET ELECTRICAL ENERGY GEN. (MKE):
643340.0 4430860.0 123697646.0
- 7. GROSS ELECT. ENERGY GEN. (MWH):
1997832.0 13548211.0 381183016.5
- 8. GROSS THERL ENERGY N. (KWH):
100.0 100.0 68.7
- 9. UNIT AVAILABILITY FACTOR (M):
100.2 64.0 99.3
- 10. UNIT CAPACITY FACTOR (MDC) (M):
0.0 0.0 16.0
- 11. UNIT FORCED OUTAGE RATE (M):
UNIT SHUTDOWNS DOCKET NO. 50-412 UNIT NAME BVPS Unit #2 DATE August 1, 2002 COMPLETED BY David T. Jones TELEPHONE (724) 682-4962 REPORTING PERIOD: July 2002 No. Date Type Duration Reason Method of Cause / Corrective Actions (YIMID) F: Forced (Hours) (1) Shutting S: Scheduled Down (2) Comments NONE (1) Reason (2) Method A - Equipment Failure (Explain) 1 - Manual B- Maintenance or Test 2 - Manual Trip / Scram C- Refueling 3 - Automatic Trip I Scram D- Regulatory Restriction 4 - Continuation E- Operator Training / Ucense Examination 5 - Other (Explain)
F - Administrative G - Operational Error (Explain)
H - Other (Explain)
SUMMARY
The Unit operated at a nominal value of 100% output for the entire report period.
OPERATING DATA REPORT DOCKET NO.: 50-412 UNIT NAME: BVPS UNIT #2 REPORT DATE: 08/01/02 COMPLETED BY: DAVID T. JONES TELEPHONE: (724) 682-4962
- Noeta: Rated thermal power at
- la. REPORTING PERIOD: JULY 2002
- BVPS-2 was uprated from 2652 MWt*
- to 2689 Mwt on 10/30/01. Net *
- 1. DESIGN ELECTRICAL RATING (Net MV.): 836
- MDC was also uprated from
- 831
- 820 MVe to 831 MEe. *
- 2. MAX. DEPENDABLE CAPACITY (Net MO): * * * * * * * * * * * * * * * * *
- THIS MONTE YEAR TO DATE CUMULATIVE 744.0 5087.0 128894.0 3a. HOURS IN REPORTING PERIOD:
744.0 4527.6 105882.1
- 3. NO. OF ERS. REACTOR WAS CRITICAL:
744.0 4460.9 105153.5
- 4. SERVICE HOURS GENERATOR ON LINE:
0.0 0.0 0.0
- 5. UNIT RESERVE SHUTDOWN HOURS:
614578.0 3570459.0 82148551.0
- 6. NET ELECTRICAL ENERGY GEN. (MWE):
647267.0 3768654.0 86843397.0
- 7. GROSS ELECT. ENERGY GEN. (MWE):
11474467.0 264882048.0 1997512.0
- a. GROSS THERMAL ENERGY GEN. (MUE):
87.7 81.6 100.0
- 9. UNIT AVAILABILITY FACTOR (M):
84.5 77.1 99.4
- 10. UNIT CAPACITY FACTOR (MDC) (M):
0.4 10.1 0.0
- 11. UNIT FORCED OUTAGE RATE (M):