DRAFT - 07/31/2002 United States Nuclear Regulatory Commission Serial No.:
02-472 Attention: Document Control Desk LR/DEA:
R0 Washington, DC 20555-0001 Docket Nos.:
50-280/281 50-338/339 License Nos.: DPR-32/37 NPF-4/7 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY (DOMINION)
SURRY AND NORTH ANNA POWER STATIONS UNITS 1 AND 2 LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION In an October 22, 2001 letter, the NRC requested additional information associated with Section 2.1 of the license renewal applications (LRAs) for Surry and North Anna Power Stations. Dominions letter dated February 1, 2002 (Serial No. 01-686A) provided the requested response. Supplemental information was also provided by letter dated May 22, 2002 (Serial No.02-163). During conversations with the NRC on July 25, 2002, the staff requested additional details of information previously provided in response to Request for Additional Information (RAI) 2.1-3. The attachment to this letter contains the requested supplemental details.
Should you have any questions regarding this submittal, please contact Mr. J. E.
Wroniewicz at (804) 273-2186.
Very truly yours, Leslie N. Hartz Vice President - Nuclear Engineering Attachment Commitments made in this letter: None
Docket Nos. 50-280/281 50-38/339 Serial No.: 02-472 Attachment Page 1 of 12 DRAFT - 07/31/2002 Attachment License Renewal Application - Supplemental Information Regarding RAI 2.1-3 Serial No.02-472 Surry and North Anna Power Station, Units 1 and 2 Virginia Electric and Power Company (Dominion)
Docket Nos. 50-280/281 50-38/339 Serial No.: 02-472 Attachment Page 2 of 12 DRAFT - 07/31/2002 Supplemental Response to RAI 2.1-3:
By letter dated October 22, 2001, the NRC staff requested additional information regarding Criterion 2 systems, structures, and components (SSCs) as defined in 10 CFR 54.4(a)(2). Dominion responded to these requests in letters dated February 1, 2002 (Serial N. 01-686A) and May 22, 2002 (Serial No.02-163). These previous submittals (in response to RAI 2.1-3, particularly) identified several plant systems at both Surry and North Anna that were added to the license renewal (LR) scope as a result of the re-evaluation of the 10 CFR Part 54 Criterion 2 requirements. The RAI responses also identified systems already in the scope of LR whose evaluation boundaries were expanded as a result of the revised Criterion 2 screening requirements.
In addition to identifying systems associated with the expanded LR scope, the previous responses also identified the credited aging management activities (AMAs) for each applicable material group, environment, and aging effects combinations for each of the identified systems. This information was provided on a system basis and was not broken down into the component groups as was done in the Aging Management Review (AMR) Results tables included in Section 3 of the License Renewal Applications (LRAs). No new material/environment combinations or aging management activities were identified as a result of the added scope.
The staff subsequently requested that Dominion provide the same level of detail that was provided in the LRA AMR Results tables for each of the additional systems (added as a result of the Criterion 2 expanded scope). That additional detail is provided with this response.
Each table provided in this response has an identifying number which begins with either an S or an N indicating its applicability to Surry or North Anna, respectively. These new tables have a number sequence that would be appropriate if they were being inserted into the existing LRAs as additional AMR Results tables. The intended functions are abbreviated as LSI, Limited Structural Integrity, as defined in the previous RAI response, and PB, Pressure Boundary.
Additional AMR Results Table Index:
Surry North Anna System Table No.
System Table No.
Chilled Water (CD)
S3.3.3-8 Bearing Cooling (BC)
N3.3.3-7 Decontamination (DC)
S3.3.10 Gaseous Waste (GW)
N3.3.8-4 Liquid Waste (LW)
S3.3.11 Decontamination (DC)
N3.3.10 Extraction Steam (ES)
S3.4-8 Extraction Steam (ES)
N3.4-8 Water Treatment (WT)
S3.4-9
Docket Nos. 50-280/281 50-38/339 Serial No.: 02-472 Attachment Page 3 of 12 DRAFT - 07/31/2002 Table S3.3.3-8 Closed Water Systems - Chilled Water: Additional Criterion 2 (Spatial Orientation) In-Scope Components Component Group Passive Function Material Group Environment Aging Effects Requiring Management Aging Management Activity (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control for Primary Systems Filter/Strainer, Pump, Tank LSI; PB Carbon Steel, Low-alloy Steel, and Cast Iron (I) Treated Water/Steam Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities (E) Borated Water Leakage Loss of Material General Condition Monitoring Activities Chemistry Control for Primary Systems Valve LSI; PB Carbon Steel, Low-alloy Steel, and Cast Iron (I) Treated Water Loss of Material Work Control Process Infrequently Accessed Area Inspection Activities (E) Air Loss of Material General Condition Monitoring Activities (E) Borated Water Leakage Loss of Material General Condition Monitoring Activities Chemistry Control for Primary Systems Pipe LSI; PB Carbon Steel, Low-alloy Steel, and Cast Iron (I) Treated Water Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control for Primary Systems Heat Exchanger (Channel Head and Shell)
LSI; PB Carbon Steel, Low-alloy Steel, and Cast Iron (I) Treated Water Loss of Material Work Control Process
Docket Nos. 50-280/281 50-38/339 Serial No.: 02-472 Attachment Page 4 of 12 DRAFT - 07/31/2002 Table S3.3.3-8 (Cont.) Closed Water Systems - Chilled Water: Additional Criterion 2 (Spatial Orientation) In-Scope Components (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control for Primary Systems Tubing, Instrument Valve Assembly, Valve LSI; PB Copper Alloys (I) Treated Water Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control for Primary Systems Tubing, Instrument Valve Assembly LSI; PB Stainless Steel (I) Treated Water Loss of Material Work Control Process
Docket Nos. 50-280/281 50-38/339 Serial No.: 02-472 Attachment Page 5 of 12 DRAFT - 07/31/2002 Table S3.3.10 Decontamination Systems: Additional Criterion 2 (Spatial Orientation)In-Scope Components Component Group Passive Function Material Group Environment Aging Effects Requiring Management Aging Management Activity Infrequently Accessed Area Inspection Activities (E) Air Loss of Material General Condition Monitoring Activities Pipe LSI; PB Stainless Steel (I) Raw Water Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Valve, Tubing, Instrument Valve Assembly LSI; PB Stainless Steel (I) Raw Water Loss of Material Work Control Process
Docket Nos. 50-280/281 50-38/339 Serial No.: 02-472 Attachment Page 6 of 12 DRAFT - 07/31/2002 Table S3.3.11 Liquid Waste Systems: Additional Criterion 2 (Spatial Orientation) In-Scope Components Component Group Passive Function Material Group Environment Aging Effects Requiring Management Aging Management Activity (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control Program for Primary Systems Heat Exchanger (Shell)
LSI; PB Stainless Steel (I) Treated Water Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Heat Exchanger (Channel Head)
LSI; PB Stainless Steel (I) Raw Water Loss of Material Work Control Process Infrequently Accessed Area Inspection Activities (E) Air Loss of Material General Condition Monitoring Activities Pipe LSI; PB Stainless Steel (I) Raw Water Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Filter/Strainer, Flow Element, Restricting Orifice, Valve, Tubing, Instrument Valve Assembly LSI; PB Stainless Steel (I) Raw Water Loss of Material Work Control Process
Docket Nos. 50-280/281 50-38/339 Serial No.: 02-472 Attachment Page 7 of 12 DRAFT - 07/31/2002 Table S3.4-8 Steam and Power Conversion Systems - Extraction Steam: Additional Criterion 2 (Spatial Orientation) In-Scope Components Component Group Passive Function Material Group Environment Aging Effects Requiring Management Aging Management Activity (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control Program for Secondary Systems Loss of Material Work Control Process Chemistry Control Program for Secondary Systems Pipe, Valve, Tubing, Instrument Valve Assembly LSI; PB Stainless Steel (I) Treated Water/Steam Cracking (>140F)
Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control Program for Secondary Systems Secondary Piping and Component Inspections Filter/Strainer, Pipe, Trap, Valve LSI; PB Carbon Steel, Low-alloy Steel, and Cast Iron (I) Treated Water/Steam Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control Program for Secondary Systems Valve, Tubing, Instrument Valve Assembly LSI; PB Copper Alloys (I) Treated Water/Steam Loss of Material Work Control Process
Docket Nos. 50-280/281 50-38/339 Serial No.: 02-472 Attachment Page 8 of 12 DRAFT - 07/31/2002 Table S3.4-9 Steam and Power Conversion Systems -Water Treatment: Additional Criterion 2 (Spatial Orientation) In-Scope Components Component Group Passive Function Material Group Environment Aging Effects Requiring Management Aging Management Activity General Condition Monitoring Activities (E) Air Loss of Material Infrequently Accessed Area Inspection Activities (I) Treated Water Loss of Material Work Control Process Pipe LSI; PB Stainless Steel (I) Raw Water (Potable water)
Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities (I) Treated Water Loss of Material Work Control Process Valve LSI; PB Stainless Steel (I) Raw Water (Potable water)
Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Pipe, Valve LSI; PB Carbon Steel, Low-alloy Steel, and Cast Iron (I) Treated Water Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Pipe, Valve LSI; PB Carbon Steel, Low-alloy Steel, and Cast Iron (I) Raw Water (Potable water)
Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Pipe, Valve LSI; PB Copper alloy (I) Raw Water (Potable water)
Loss of Material Work Control Process
Docket Nos. 50-280/281 50-38/339 Serial No.: 02-472 Attachment Page 9 of 12 DRAFT - 07/31/2002 Table N3.3.3-7 Closed Water Systems - Bearing Cooling: Additional Criterion 2 (Spatial Orientation) In-Scope Components Component Group Passive Function Material Group Environment Aging Effects Requiring Management Aging Management Activity (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control for Secondary Systems Filter/Strainer, Pipe, Pumps, Tank, Valve LSI; PB Carbon Steel, Low-alloy Steel, and Cast Iron (I) Treated Water Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control for Secondary Systems Valve, Tubing, Instrument Valve Assembly LSI; PB Copper Alloys (I) Treated Water Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control for Secondary Systems Expansion Joint, Restricting Orifice, Tubing, Instrument Valve Assembly LSI; PB Stainless Steel (I) Treated Water Loss of Material Work Control Process
Docket Nos. 50-280/281 50-38/339 Serial No.: 02-472 Attachment Page 10 of 12 DRAFT - 07/31/2002 Table N3.3.8-4 Vent and Gaseous Processing Systems - Gaseous Waste: Additional Criterion 2 (Spatial Orientation) In-Scope Components Component Group Passive Function Material Group Environment Aging Effects Requiring Management Aging Management Activity General Condition Monitoring Activities (E) Air Loss of Material Infrequently Accessed Area Inspection Activities Pipe LSI; PB Stainless Steel (I) Gas1 Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Valve, Tubing, Instrument Valve Assembly LSI; PB Stainless Steel (I) Gas1 Loss of Material Work Control Process General Condition Monitoring Activities (E) Air Loss of Material Infrequently Accessed Area Inspection Activities (E) Borated Water Leakage Loss of Material General Condition Monitoring Activities Pipe LSI; PB Carbon Steel, Low-alloy Steel, and Cast Iron (I) Gas1 Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities (E) Borated Water Leakage Loss of Material General Condition Monitoring Activities Valve LSI; PB Carbon Steel, Low-alloy Steel, and Cast Iron (I) Gas1 Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities (E) Borated Water Leakage Loss of Material General Condition Monitoring Activities Tubing, Instrument Valve Assembly LSI; PB Copper Alloys (I) Gas1 Loss of Material Work Control Process 1 Relief valve operation has the potential to intermittently wet Gaseous Waste component internals
Docket Nos. 50-280/281 50-38/339 Serial No.: 02-472 Attachment Page 11 of 12 DRAFT - 07/31/2002 Table N3.3.10 Decontamination Systems: Additional Criterion 2 (Spatial Orientation) In-Scope Components Component Group Passive Function Material Group Environment Aging Effects Requiring Management Aging Management Activity Infrequently Accessed Area Inspection Activities (E) Air Loss of Material General Condition Monitoring Activities Pipe LSI; PB Stainless Steel (I) Raw Water Loss of Material Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Valve, Tubing, Instrument Valve Assembly LSI; PB Stainless Steel (I) Raw Water Loss of Material Work Control Process
Docket Nos. 50-280/281 50-38/339 Serial No.: 02-472 Attachment Page 12 of 12 DRAFT - 07/31/2002 Table N3.4-8 Steam and Power Conversion Systems - Extraction Steam: Additional Criterion 2 (Spatial Orientation) In-Scope Components Component Group Passive Function Material Group Environment Aging Effects Requiring Management Aging Management Activity (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control Program for Secondary Systems Loss of Material Work Control Process Chemistry Control Program for Secondary Systems Pipe, Valve, Tubing, Instrument Valve Assembly LSI; PB Stainless Steel (I) Treated Water/Steam Cracking (>140F)
Work Control Process (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control Program for Secondary Systems Work Control Process Pipe, Trap, Valve LSI; PB Carbon Steel, Low-alloy Steel, and Cast Iron (I) Treated Water/Steam Loss of Material Secondary Piping and Component Inspections (E) Air Loss of Material General Condition Monitoring Activities Chemistry Control Program for Secondary Systems Valve, Tubing, Instrument Valve Assembly LSI; PB Copper Alloys (I) Treated Water/Steam Loss of Material Work Control Process