ML021830041

From kanterella
Jump to navigation Jump to search

RAI, Related to Relief Request No. 28
ML021830041
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 07/11/2002
From: Vissing G
NRC/NRR/DLPM
To: Kansler M
Entergy Nuclear Operations
Vissing G, NRR/DLPM, 415-1441
References
TAC MB3750
Download: ML021830041 (5)


Text

July 11, 2002 Mr. Michael Kansler Sr. Vice President and Chief Operating Officer Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601

SUBJECT:

JAMES A. FITZPATRICK NUCLEAR POWER PLANT - REQUEST FOR ADDITIONAL INFORMATION RELATED TO RELIEF REQUEST NO. 28 (TAC NO. MB3750)

Dear Mr. Kansler:

In reviewing your submittal of May 8, 2002, concerning the subject relief request, the U.S. Nuclear Regulatory Commission (NRC) staff discussed the issue with your staff on June 24, 2002, and outlined additional information that the NRC needs to continue its review.

The information needed was e-mailed to your staff on June 25, 2002, and, as we indicated during our conversation, we are enclosing the request for additional information. Your staff has indicated that you can respond within a short time since you require the relief before your next refueling outage.

Sincerely,

/RA/

Guy S. Vissing, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation

Enclosure:

As stated cc w/encl: See next page

ML021830041 OFFICE PDI-1/PM PDI-1/LA PDI-1/SC NAME GVissing TClark for SLittle PTam for RLaufer DATE 7/9/02 7/9/02 7/11/02 FitzPatrick Nuclear Power Plant cc:

Mr. Jerry Yelverton Supervisor Chief Executive Officer Town of Scriba Entergy Operations Route 8, Box 382 1340 Echelon Parkway Oswego, NY 13126 Jackson, MS 39213 Charles Donaldson, Esquire Mr. Theodore H. Sullivan Assistant Attorney General Vice President Operations New York Department of Law Entergy Nuclear Operations, Inc. 120 Broadway James A. FitzPatrick Nuclear Power Plant New York, NY 10271 P.O. Box 110 Lycoming, NY 13093 Regional Administrator, Region I U.S. Nuclear Regulatory Commission Mr. Dan Pace 475 Allendale Road Vice President, Engineering King of Prussia, PA 19406 Entergy Nuclear Operations, Inc.

440 Hamilton Avenue Oswego County Administrator White Plains, NY 10601 Jack Tierney 46 East Bridge Street Mr. John Kelly Oswego, New York 13126 Director - Licensing Entergy Nuclear Operations, Inc. Mr. William M. Flynn, President 4400 Hamilton Avenue New York State Energy, Research, White Plains, NY 10601 and Development Authority Corporate Plaza West Mr. George Tasick 286 Washington Avenue Extension Licensing Manager Albany, NY 12203-6399 Entergy Nuclear Operations, Inc.

James A. FitzPatrick Nuclear Power Plant Mr. Arthur Zaremba, Licensing Manager P.O. Box 110 Director, Safety Assurance Lycoming, NY 13093 Entergy Nuclear Operations, Inc.

James A. FitzPatrick Nuclear Power Plant Resident Inspectors Office P.O. Box 110 U. S. Nuclear Regulatory Commission Lycoming, NY 13093 P.O. Box 136 Lycoming, NY 13093 Mr. Paul Eddy Electric Division Mr. Harry P. Salmon, Jr. New York State Dept. of Public Service Director of Oversight 3 Empire State Plaza, 10th Floor Entergy Nuclear Operations, Inc. Albany, NY 12223 440 Hamilton Avenue White Plains, NY 10601 Ms. Charlene D. Faison Licensing Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601

FitzPatrick Nuclear Power Plant cc:

Michael J. Colomb Mr. Tim Judson General Manager Organizer Entergy Nuclear Operations, Inc. Citizens Awareness Network James A. FitzPatrick Nuclear Power Plant 140 Bassett St.

P.O. Box 110 Syracuse, NY 13210 Lycoming, NY 13093 Deborah Katz Mr. James Knubel Executive Director Vice President, Operations Support Citizens Awareness Network Entergy Nuclear Operations, Inc. P.O. Box 83 440 Hamilton Avenue Shelburne Falls, MA 01370 White Plains, NY 10601 Shawn McConnell Mr. John M. Fulton NYPIRG Project Coordinator Assistant General Counsel 13 Hewitt Union Entergy Nuclear Generation Co. SUNY Oswego Pilgrim Station Oswego, NY 13126 600 Rocky Hill Road Plymouth, MA 02360 Tom Dellwo Oswego NYPIRG Environmental Mr. J. Spath, Program Director Project Leader New York State Energy, Research, and 13 Hewitt Union Development Authority SUNY Owego Corporate Plaza West Oswego, NY 13126 286 Washington Avenue Extension Albany, NY 12203-6399 Mr. Ronald Schwartz SRC Consultant 64 Walnut Drive Spring Lake Heights, NJ 07762 Mr. Ronald J. Toole SRC Consultant Toole Insight 605 West Horner Street Ebensburg, PA 15931 Mr. Charles W. Hehl SRC Consultant Charles Hehl, Inc.

1486 Matthew Lane Pottstown, PA 19465

REQUEST FOR ADDITIONAL INFORMATION JAMES A. FITZPATRICK RELIEF REQUEST NO.28

1. Code Cases N-513 Evaluation Criteria for Temporary Acceptance of Flaws in Class 3 Piping,Section XI, Division 1" and N-523 Mechanical Clamping Devices for Class 2 and 3 Piping,Section XI, Division 1" and Generic Letter 90-05 Guidance for Performing Temporary Non-Code Repair of ASME Code Class 1, 2 and 3 Piping are available as alternative methods of repair or analytical evaluation of pipe wall thinning or pitting.

Discuss why these alternatives cannot be used in this specific application.

2. The relief request should:

a) state the specific pipe lines and locations that may be restored using this code case.

b) state the approximate number and size (length, width, thickness) of the overlay repairs.

c) specify that this repair will only be used for one cycle.

3. To justify the applicability of the weld overlay repair, for one cycle, provide the expected degradation rates for the corresponding degradation mode. Provide past inspection results to support these degradation rate(s).

Enclosure