POSITION DESCRIPTION Program Manager, Chemistry (PWR)

Chattanooga ganization Titles:

Nuclear Operations Operations Ocerations Suocort Radiological Control and Chemistry Social Security Number Pay Group or Schedule/Grade Effective Date Incumbents Signature Supervisor's Signature HRM/HRO's Signature Reports to (TOe)

Manager, Radiological Control and Chemistry Section FOR COMPEIVSAT70N PLANNING AND ANALYSIS USE ONLY lSITION EVALUATION:

EVALUATION DATE:

CP&A REVIEWER INITIALS:

K-H Slot K-H Pts P-S Slot P-S Pta Acct Slot Acct Pts Total Pts Profile OSITION PURPOSE:

rovide senior technical direction, expert support, oversight, and Program/Project management in the chemistry programs of the VAN facilities. Develop programmatic requirements for chemistry management programs. The incumbent serves as the primary aison between the TVAN sites and TVAN corporate. The incumbent manages the implementation of directives, standards, and olicies and regulations at all TVAN sites. The incumbent is the lead individual for ensuring that high standards are set and laintained at both corporate and the TVAN sites. His/her efforts are focused on establishing/maintaining a chemistry program. that nhances the safe and reliable operation of TVAN sites.

)IMENSIONS:

"ypical size of projects - 310M - $10MM. Annual projects managed - 10 3ther Incumbent acts as Manager, Radiological Control and Chemistry, in his absence with the signature authority and control of the budget ($3 MM) associated with that position.

L Serves as Technical Contract Manager establishing, controlling, and maintaining multi-site chemistry services and material contracts. -(Material and Services Annual Budget.SIOMM)

3. Serves as Radiological Assessment Manager in the event of a nuclear site emergency.

"'stribution: Original - Human Resources Microrecords Unit, Knoxville Ccpy - Operations Organization (as needed)

Copy - Central Office of Union Having Jurisdiction Copy - Employee (TVA 12A[HR 7-911 Page 1 of 3)

Exhibit 1 sition Title

ation Group Division Department

_SSN EFFECTIVE DATE (Fist) (Middle) (Last)

UNCIPAL ACCOUNTABILITIES:

eas of Resoonsibilities:

SON. WBN (PWR) Secondary Chemistry Program Post accident sampling systems Cooling tower chemistry Software control program Analytical Working Group Management for all TVAN sites Multi-Site Technical contract Management such as Ecolochem. Dionex. PASS services for all TVAN sites

'incipal Accountabilities:

Provide technical and programmatic expertise for implementation of the TVAN chemistry program at individual sites.

Provide direction as needed for project manager's managing projects at SON and WBN. Oversee the activities of other personnel assigned support functions for meeting the responsiblifties of this position.

Function as the TVAN senior technical expert to the sites in the areas of PWR Secondary chemistry control.

Function as the TVAN senior technical expert and provide direction in the implementation of such programs as Molar Ratio Control. Secondary Chemistry Optimization, and zinc injection.

Assist Management with interpretation of chemistry policy - review and concur with site pr6cedures and other TVAN documents that may impact the programs. Promote optimum consistency among site programs.

Recommend chemistry program goals and specifications that are consistent with best industry practices, and assist with the implementation of actions to achieve them. Direct the performance of site evaluations of the chemistry program to ensure consistency and compliance with established requirements.

Direct review and concur with root cause analyses for identified site chemistry program problems, direct the development of corrective action plans, and coordinate the implementation of approved corrective actions.

Direct the performance of regulatory and licensing reviews of chemistry issues, recommend TVAN responses or positions.

and concur with responses to external organizations.

\\..

Develop and conduct specialized seminars on chemistry technical topics as requested and conduct periodic training related observations I provide recommendations for improvements as necessary.

3. Provide long-term I large scope project support to WBN and SON for major chemistry projects. Provide short-term plant problem response to the sites as requested.

.0. Perform long-term data trending and assessment of key WBN and SON Secondary chemistry data. Provide appropriate feedback and corrective action proposals as necessary. Prepare an annual WBN and SON chemistry report with review and concurrence with site staffs and issue.

11. Function as a TVAN representative to the EPRI PWR Secondary water chemistry committee. PWR Owners Group Chemnistry Committee, and appropriate industry & regulatory workshopsiconferencesl seminars. Coordinate the release of chemistry data to outside organizations as authorized.
12. Serve as a Chemistry specialist, dose assessor, or RAC/RAM in the event of a radiological emergency. Remain on caH 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> a day unless relieved by other appropriate personnel during emergency events.
13. Actively engage in plant tours, personnel interviews, observation feedback and working meetings during routine operations and plant outages. Coordinate with sites for INPO evaluations and responses.
14. Function as team leader and provide technical expertise in support of the Quarterly Chemistry Team assessments for TVAN sites.
15. Chair Analytcal Working Group for all WAN sites.
16. Develop multi-site contract technical specifications and act as technical cohtract manager for applicable contracts such as makeup water. Dionex services, PASS services, bulk chemicals for all sites.
17. Act for the Corporate Radiological and Chemistry Control Manager in his/her absence.
18. Provide effective communications of the Corporate Chemistry Program to the TVA nuclear sites.

-(TVA 12ACHR 7-91] Page 2 of 3)

W',

IMUM QUALIFICATIONS:

The incumbent should have a bachelor's degree or the equivalent in chemistry, environmental sciences, or chemical engineering, including formal training and experience in management The incumbent shall have at least eight years of professional experience in applied chemistry, with experience at an operating nuclear power plant preferable. The incumbent should have a detailed knowledge of modem analytical and radioanalytical equipment and methods used for performing all required chemistry analyses at TVAN sites which includes equipment operation and capabilities. He/she must possess a very good knowledge base in the areas of PWR and BWR chemistry control guidelines requirements. An advanced degree and ten years experience at the professional or managerial level are desirable.