JAFNPP TABLE 3.2-7 ATWS RECIRCULATION PUMP TRIP INSTRUMENTATION REQUIREMENTS Minimum Number of Operable Instrument Channels Per Trip System (Notes I & 2) 2 2
Trip Function Reactor Pressure - High Reactor Water Level - Low Low Trig Level Setting
- s 1155 psig
> 105.4 in.
above TAF Applicable Modes Run Run Amendment No. 22 7T2 3 7, 26 4,
2 7 3 76a
JAFNPP THIS PAGE INTENTIONALLY BLANK Amendment No. 237, 2 7 3 76c