License Amendment 159, Revising Volumetric Air Flow Units for Technical Specification 4.7.6.c.1, c.3, e.1, e.3, F, and G to Identify Standard Airflow Units Expressed as Standard Cubic Feet Per Minute
ML021050516
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 04/11/2002
From: Edison G
NRC/NRR/DLPM/LPD2
To: Byrne S
South Carolina Electric & Gas Co
References
TAC MB1844
Download: ML021050516 (10)


Text

April 11, 2002 Mr. Stephen A. Byrne Senior Vice President, Nuclear Operations South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station Post Office Box 88 Jenkinsville, South Carolina 29065

SUBJECT:

VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 - ISSUANCE OF AMENDMENT RE: REVISION OF VENTILATION SYSTEM AIR FLOW VELOCITY UNITS (TAC NO. MB1844)

Dear Mr. Byrne:

The Nuclear Regulatory Commission has issued the enclosed Amendment No. 159 to Facility Operating License No. NPF-12 for the Virgil C. Summer Nuclear Station, Unit No. 1.

The amendment changes the Technical Specifications (TS) in response to your application dated April 18, 2001.

This amendment revises volumetric air flow units for TS 4.7.6.c.1, c.3, e.1, e.3, f, and g to identify standard air flow units expressed as standard cubic feet per minute. Volumetric air flow units for TS 4.6.3.b.1, b.2, c.1, and d, and TS 4.9.11.b.1, b.3, d.1, e, and f are being revised to identify actual air flow units and are expressed as actual cubic feet per minute.

A copy of the related Safety Evaluation is enclosed. Notice of Issuance will be included in the Commissions Bi-weekly Federal Register notice. This completes the staffs efforts on TAC No. MB1844.

Sincerely,

/RA/

Gordon E. Edison, Senior Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-395

Enclosures:

1. Amendment No. 159 to NPF-12
2. Safety Evaluation cc w/enclosures: See next page

Mr. Stephen A. Byrne April 11, 2002 Senior Vice President, Nuclear Operations South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station Post Office Box 88 Jenkinsville, South Carolina 29065

SUBJECT:

VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 - ISSUANCE OF AMENDMENT RE: REVISION OF VENTILATION SYSTEM AIR FLOW VELOCITY UNITS (TAC NO. MB1844)

Dear Mr. Byrne:

The Nuclear Regulatory Commission has issued the enclosed Amendment No. 159 to Facility Operating License No. NPF-12 for the Virgil C. Summer Nuclear Station, Unit No. 1.

The amendment changes the Technical Specifications (TS) in response to your application dated April 18, 2001.

This amendment revises volumetric air flow units for TS 4.7.6.c.1, c.3, e.1, e.3, f, and g to identify standard air flow units expressed as standard cubic feet per minute. Volumetric air flow units for TS 4.6.3.b.1, b.2, c.1, and d, and TS 4.9.11.b.1, b.3, d.1, e, and f are being revised to identify actual air flow units and are expressed as actual cubic feet per minute.

A copy of the related Safety Evaluation is enclosed. Notice of Issuance will be included in the Commissions Bi-weekly Federal Register notice. This completes the staffs efforts on TAC No. MB1844.

Sincerely,

/RA/

Gordon E. Edison, Senior Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-395

Enclosures:

1. Amendment No. 159 to NPF-12
2. Safety Evaluation cc w/enclosures: See next page DISTRIBUTION:

PUBLIC GEdison GHill (2)

PDII-1 Reading EDunnington WBeckner HBerkow OGC Region II JNakoski ACRS Accession Number: ML021050516 Technical Specifications Accession No. ML Package Number: ML

  • See previous concurrence NRR-058 OFFICE PM:PDII-1 E LA:PDII-2 SPLB*

OGC*

SC:PDII-1 NAME GEdison GEdison/ for EDunnington RCHagar JHeck JNakoski DATE 4/11/02 4/11/02 4/04/02 4/09/02 4/11/02 OFFICIAL RECORD COPY

SOUTH CAROLINA ELECTRIC & GAS COMPANY SOUTH CAROLINA PUBLIC SERVICE AUTHORITY DOCKET NO. 50-395 VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 159 License No. NPF-12 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by South Carolina Electric & Gas Company (the licensee), dated April 18, 2001, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Commissions rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commissions regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commissions regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications, as indicated in the attachment to this license amendment; and paragraph 2.C.(2) of Facility Operating License No. NPF-12 is hereby amended to read as follows:

(2)

Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No. 159, and the Environmental Protection Plan contained in Appendix B, are hereby incorporated in the license. South Carolina Electric

& Gas Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This amendment is effective as of its date of issuance and shall be implemented within 30 days of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

/RA/

John A. Nakoski, Chief, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: April 11, 2002

ATTACHMENT TO LICENSE AMENDMENT NO. 159 TO FACILITY OPERATING LICENSE NO. NPF-12 DOCKET NO. 50-395 Replace the following pages of the Appendix A Technical Specifications with the attached revised pages. The revised pages are identified by amendment number and contain marginal lines indicating the areas of change.

Remove Pages Insert Pages 3/4 6-15 3/4 6-15 3/4 6-16 3/4 6-16 3/4 7-15 3/4 7-15 3/4 9-12 3/4 9-12 3/4 9-13 3/4 9-13

SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO AMENDMENT NO. 159 TO FACILITY OPERATING LICENSE NO. NPF-12 SOUTH CAROLINA ELECTRIC & GAS COMPANY SOUTH CAROLINA PUBLIC SERVICE AUTHORITY VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 DOCKET NO. 50-395

1.0 INTRODUCTION

By application dated April 18, 2001, South Carolina Electric & Gas Company (SCE&G, the licensee) requested changes to the Technical Specifications (TS) for the Virgil C. Summer Nuclear Station (VCSNS). The proposed changes would revise volumetric air flow units for TS 4.7.6.c.1, c.3, e.1, e.3, f, and g to identify standard air flow units expressed as standard cubic feet per minute (SCFM). Volumetric air flow units for TS 4.6.3.b.1, b.2, c.1, and d, and TS 4.9.11.b.1, b.3, d.1, e, and f are being revised to identify actual air flow units and are expressed as actual cubic feet per minute (ACFM).

2.0 EVALUATION ACFM and SCFM are units for volumetric air flow rates. ACFM is a measure of the actual volumetric air flow rate at the conditions of the air stream. The density of air varies with temperature and pressure. SCFM is a measure of the volumetric flow rate if the air stream were at standard conditions. Standard conditions are defined as 70BF and 1 atmosphere pressure.

The term CFM currently used at VCSNS is an acronym for cubic feet per minute and does not properly relate to design considerations nor does it account for the effect of air density. Design air flow is typically based on air at standard conditions. Volumetric air flows measured for the surveillances of TS 4.7.6 are converted for air density changes and expressed in SCFM. The existing nomenclature of CFM does not present this information adequately. Volumetric air flows measured for TS 4.6.3 and TS 4.9.11 are expressed in ACFM due to their specific design application.

The NRC staff finds this change acceptable because these terms clarify the units of air flow relating to the conditions required by the affected TS. The change does not increase the probability of an accident, there is no adverse effect to equipment safety, nor is there a reduction in margin of safety.

3.0 STATE CONSULTATION

In accordance with the Commissions regulations, the State of South Carolina official was notified of the proposed issuance of the amendment. The State official had no comments.

4.0 ENVIRONMENTAL CONSIDERATION

The amendment changes surveillance requirements. The NRC staff has determined that the amendment involves no significant increase in the amounts, and no significant change in the types of any effluents that may be released offsite and that there is no significant increase in individual or cumulative occupational radiation exposure. The Commission has previously issued a proposed finding that the amendment involves no significant hazards consideration, and there has been no public comment on such finding (66 FR 29361). Accordingly, the amendment meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Pursuant to 10 CFR 51.22(b) no environmental impact statement or environmental assessment need be prepared in connection with the issuance of the amendment.

5.0 CONCLUSION

The Commission has concluded, based on the considerations discussed above, that (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the Commissions regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.

Principal Contributor: Karen Cotton Date: April 11, 2002

Mr. Stephen A. Byrne VIRGIL C. SUMMER NUCLEAR STATION South Carolina Electric & Gas Company cc:

Mr. R. J. White Ms. Kathryn M. Sutton, Esquire Nuclear Coordinator Winston & Strawn Law Firm S.C. Public Service Authority 1400 L Street, NW c/o Virgil C. Summer Nuclear Station Washington, DC 20005-3502 Post Office Box 88, Mail Code 802 Jenkinsville, South Carolina 29065 Resident Inspector/Summer NPS c/o U.S. Nuclear Regulatory Commission 576 Stairway Road Jenkinsville, South Carolina 29065 Chairman, Fairfield County Council Drawer 60 Winnsboro, South Carolina 29180 Mr. Henry Porter, Assistant Director Division of Waste Management Bureau of Land & Waste Management Department of Health & Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Mr. Gregory H. Halnon, General Manager Nuclear Plant Operations South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station, Mail Code 303 Post Office Box 88 Jenkinsville, South Carolina 29065 Mr. Melvin N. Browne, Manager Nuclear Licensing & Operating Experience South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station, Mail Code 830 Post Office Box 88 Jenkinsville, South Carolina 29065