Text

Monticello Nuclear Generating Plant Operated by Nuclear Management Company, LLC NMC-t Committed to Nuclear Excellenc March 7, 2002 10 CFR 50, Appendix E Section V US Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 MONTICELLO NUCLEAR GENERATING PLANT Docket No. 50-263 License No. DPR-22 Emer-gency Plan Implementing Procedures Furnished with this letter is a revision to the Monticello Nuclear Generating Plant Emergency Plan Implementing Procedures. The following procedures are revised:

Procedure A.2-401 Procedure Title Emergency Exposure Control Revision 8

Please post changes in your copy of the Monticello Nuclear Generating Plant Emergency Plan Implementing Procedures. Superseded procedures should be destroyed. This revision does not reduce the effectiveness of the Monticello Nuclear Generating Plant Emergency Plan.

Please contact Douglas A. Neve, Project Manager - Licensing, at (763) 295-1353 if you require further information.

Jeffrey S. Forbes Site Vice President Monticello Nuclear Generating Plant c:

Regional Administrator - Ill, NRC (w/ two copies of enclosure)

NRR Project Manager, NRC (w/o enclosure)

Sr Resident Inspector, NRC (w/o enclosure)

Minnesota Dept. of Commerce (w/o enclosure)

J. E. Silberg (w/o enclosure)

JALICENSE\\NRC Misc Correspondence\\Emergency Plan\\3-O1-O2EPIP letter.doc 2807 West County Road 75

  • Monticello, Minnesota 55362-9637 Telephone: 763.295.5151 e Fax: 763.295.1454

-(-\\ 0ý Y\\

MONTICELLO NUCLEAR GENERATING PLANT A.2-401 TITLE:

EMERGENCY EXPOSURE CONTROL Revision 8 Page 1 of 9 EMERGENCY PLAN IMPLEMENTING PROCEDURE - TABLE OF CONTENTS SECTION Pi 1.0 PU R PO S E........................................................

2.0 APPLICABILITY...................................................

3.0 ORGANIZATION AND RESPONSIBILITIES...........................

4.0 D ISC U SS IO N......................................................

5.0 PRECAUTIO NS....................................................

6.0 INSTRUCTIO NS...................................................

6.1 Emergency Exposure Authorization.............................

7.0 FIG U R E S.........................................................

7.1 Emergency Worker Exposure Limits............................

7.2 Effects of Acute Exposures....................................

7.3 Forms Utilized in the Procedure................................

2 2

3 4

5 5

7 7

8 9

Prepared By:

ALARA Coord Review By:

OC Review Req'd: YES 00 Meeting Number: )-3 C I F Date://-,,

)v -z.-

Approved By:

Date:>/,%.k This revision incorporates Volume F Memos:

EOVL 3087 (DOCUMENT CHANGE, HOLD, AND COMMENT FORM) incorporated:

c; k -

L A-I Resp Supv:

GTRNG jAssoc Ref: A.2 01SO: N Freq:

11 Vrs ARMS:

A.2-401 Doc Type: 1060 1 Admin Initials:

k gate./,1/ý I/saw

MONTICELLO NUCLEAR GENERATING PLANT A.2-401 TITLE:

EMERGENCY EXPOSURE CONTROL Revision 8 Page 2 of 9 1.0 PURPOSE This procedure provides guidance and criteria for the authorization of personnel exposure to radiation in excess of federal or administrative limits during an emergency.

2.0 APPLICABILITY 2.1 An emergency condition at the Monticello Nuclear Generating Plant has resulted in radiation levels within the plant greatly in excess of normal levels and special considerations are required for exposure control.

2.2 It has been determined that individual doses for a job are expected to result in an individual exceeding his/her plant administrative limit.

3.0 ORGANIZATION AND RESPONSIBILITIES 3.1 The Emergency Director (ED) is responsible for:

3.1.1 Authorization of emergency exposure.

3.1.2 Authorizing the REC to approve personnel exposures in excess of Administrative or Federal limits.

3.2 The Radiological Emergency Coordinator (REC) is responsible for:

3.2.1 Overall direction of the Radiation Protection exposure control activities during an emergency.

3.2.2 Authorization of emergency exposures (when delegated by the ED).

3.3 The Radiation Protection Coordinator is responsible for:

3.3.1 Coordination of exposure control activities during an emergency.

3.4 Radiation Protection Specialists are responsible for:

3.4.1 Implementation of this procedure under the direction of the RPC.

3.4.2 Ensuring all emergency exposure records are properly documented.

I/saw

MONTICELLO NUCLEAR GENERATING PLANT A.2-401 TITLE:

EMERGENCY EXPOSURE CONTROL Revision 8 Page 3 of 9 4.0 DISCUSSION 4.1 Summary 4.1.1 The exposure of personnel during emergency operation SHALL be maintained as low as reasonably achievable (ALARA) and should be maintained less than the administrative guides established in the MNGP administrative control documents and/or less than the federal radiation exposure standards established in 1 OCFR20 if practicable.

4.1.2 In order to accomplish this objective, administrative means used during normal operations to minimize personnel exposure (such as radiation work permits and ALARA measures) should remain in force to the extent consistent with timely implementation of emergency measures.

4.1.3 If necessary, operations require personnel exposures in excess of the normal limits, or if normal access control and radiological work practices will result in unacceptable delays, the Radiological Emergency Coordinator may, at his discretion, waive or modify the established exposure control criteria and methods in accordance with the provisions of this procedure. In making such decisions, the Radiological Emergency Coordinator should call upon the expertise of the radiation protection staff on-site, if readily available.

4.2 Authority 4.2.1 The Emergency Director has the authority to perform the appropriate protective and corrective measures necessary to mitigate the consequences of an accident and to restore the plant to a safe condition. If necessary, the Emergency Director may authorize the Radiological Emergency Coordinator to approve personnel exposures in excess of normal guides/limits, but not greater than the planned radiation exposure criteria established in this procedure, provided the pre-conditions of such exposure are met. The REC SHALL be the only individual besides the Emergency Director authorized to permit emergency exposure.

4.3 Emergency Exposure Criteria 4.3.1 The exposure received pursuant to the performance of emergency measures should be commensurate with the significance of the action to be performed and should be maintained at a level which is as low as reasonably achievable (ALARA). Criteria for emergency exposures are established in EPA 400-R-92-001 and FIGURE 7.1.

I/saw

MONTICELLO NUCLEAR GENERATING PLANT A.2-401 TITLE:

EMERGENCY EXPOSURE CONTROL Revision 8 Page 4 of 9 4.4 Considerations and Conditions 4.4.1 Personnel receiving increased exposure should be volunteers.

4.4.2 Personnel should be broadly familiar with the consequences of any exposures received under emergency conditions as per FIGURE 7.2.

4.4.3 Women in their reproductive years should not take part in these actions.

4.4.4 Women who have declared their pregnancy or are participating in the Monticello Unborn Child Protection Program SHALL follow the requirements of that program.

4.4.5 Exposures under these conditions should be limited to once in a lifetime.

4.4.6 Internal exposure should be minimized by the use of appropriate respiratory equipment, and contamination should be controlled by the use of appropriate protective clothing.

4.4.7 Volunteers above age of 45 are recommended.

4.5 Post-Exposure Evaluations 4.5.1 Personnel receiving exposures under emergency conditions should be restricted from further occupational exposure pending the outcome of exposure evaluations and, if necessary, medical surveillance.

5.0 PRECAUTIONS 5.1 Personnel SHALL NOT enter any area where does rates are unknown and unmeasurable or when dosimetry is not immediately available.

5.2 Appropriate dosimetry, which is capable of measuring the anticipated maximum exposure and type of radiations, SHALL be worn.

5.3 Extremity dosimeters SHALL be worn if it's anticipated that the extremity exposure is greater than two (2) times that of the whole body.

I/saw

MONTICELLO NUCLEAR GENERATING PLANT A.2-401 TITLE:

EMERGENCY EXPOSURE CONTROL Revision 8 Page 5 of 9 6.0 INSTRUCTIONS 6.1 Emergency Exposure Authorization IMPORTANT:

In the event a planned emergency exposure is necessary, the following actions should be performed. Although it is preferable to perform and document these steps prior to the exposure, if necessary, the Emergency Director may verbally authorize the increased exposure and complete the documentation at a later time.

6.1.1 Initiate Form 5790-401 -01 (EMERGENCY EXPOSURE AUTHORIZATION FORM).

6.1.2 Complete PART A of the EMERGENCY EXPOSURE AUTHORIZATION as follows:

A.

Record personal information provided by the individual and/or other exposure control files; B.

Record the date the exposure was authorized and the authorized exposure limit (refer to Form 5790-107-04 (EMERGENCY WORK REQUEST) if completed);

C.

Check the applicable INDIVIDUAL INFORMATION boxes; D.

Check the applicable EMERGENCY ACTIONS boxes; E.

Thoroughly brief the individual on the consequences of acute emergency exposures (review the EFFECTS OF ACUTE EXPOSURES, FIGURE 7.2) and other aspects of the emergency action; F.

Sign and date the completed PART A.

6.1.3 Instruct the individual to review PART A, read and sign PART B of the EMERGENCY EXPOSURE AUTHORIZATION form.

6.1.4 Route the completed form to the Radiological Emergency Coordinator for review and Emergency Director approval.

6.1.5 After the individual receives emergency exposure the Radiological Emergency Coordinator should:

A.

Restrict the individual(s) from further exposure until an exposure evaluation is completed.

B.

Complete an exposure evaluation of each individual based on dosimetry results, measured dose rates, airborne activity measurements, whole body counts, and area staytimes.

I/saw

IMONTICELLO NUCLEAR GENERATING PLANT A,2-401 TITLE:

EMERGENCY EXPOSURE CONTROL Revision 8 Page 6 of 9 C.

Complete Part IV of Form 5790-401 -01 (EMERGENCY AUTHORIZATION FORM).

6.1.6 If the dose equivalent exceeds 25 REM whole body, 100 REM skin or 100 REM extremity, the details of the exposure should be evaluated by the Radiological Emergency Coordinator and the individual should be examined by a physician and have appropriate tests completed.

I/saw

MONTICELLO NUCLEAR GENERATING PLANT A.2-401 TITLE:

EMERGENCY EXPOSURE CONTROL Revision 8 Page 7 of 9 7.0 FIGURES FIGURE 7.1 Emergency Worker Exposure Limits EXPOSURE LIMIT 1 EMERGENCY ACTIVITY1 COMMENTS 5 REM (TEDE)(2)(3)

All emergency activities This dose limit applies when a lower dose is not practicable through application of ALARA practices.

10 REM (TEDE)(2)(3)

Protection of valuable This dose limit applies when property a lower dose is not practicable through application of ALARA practices.

> 25 REM (TEDE)(2)(3)

Life saving or protection of Doses in excess of 25 REM large populations should be on a voluntary basis to persons fully aware of the risks involved.

NOTE 1:

Dose limits for emergency workers and activities are based on EPA 400-R-92-001, May 1992.

NOTE 2:

Sum of external effective dose equivalent and committed effective dose equivalent to non-pregnant adults from external exposure and intake during the duration of an emergency.

NOTE 3:

Exposure to the lens of the eye should be limited to 3 times the value listed and doses to the skin and/or extremities should be limited to 10 times the value listed.

I/saw

MONTICELLO NUCLEAR GENERATING PLANT A.2-401 TITLE:

EMERGENCY EXPOSURE CONTROL Revision 8 Page 8 of 9 FIGURE 7.2 Effects of Acute Exposures Health Effects Associated with Whole-Body Absorbed Doses Received Within a Few Hoursa Whole Body Early Whole Body Absorbed Dose Fatalitiesb Absorbed Dose Prodromal Effectsc (Rad)

(percent)

(Rad)

(percent affected) 140 5

50 2

200 15 100 15 300 50 150 50 400 85 200 85 460 95 250 98 a Risks will be lowered for protracted exposure periods.

b Supportive medical treatment may increase the dose at which these frequencies occur approximately 50 percent.

Forewarning symptoms of more serious health effects associated with large doses of radiation.

Approximate Cancer Risk to Average Individuals from 25 Rem Effective Dose Equivalent Delivered Promptly Appropriate risk Average years of Age at of premature death life lost if premature exposure (deaths per 1,000 death occurs (years) persons exposed)

(years) 20 to 30 9.1 24 30 to 40 7.2 19 40 to 50 5.3 15 50 to 60 3.5 11 I/saw

MONTICELLO NUCLEAR GENERATING PLANT A.2-401 TITLE:

EMERGENCY EXPOSURE CONTROL Revision 8 Page 9 of 9 5790-401-01 5790-107-04 FIGURE 7.3 Forms Utilized in the Procedure Emergency Exposure Authorization Form Emergency Work Request I/saw 1.

2.