ES-201 Examination Preparation Checklist Form ES-201-1 Facility:

Mf-3 Date of Examination: //"/0 Examinations Developed by:

(cili

/

NRC (circle one)

Target Chief Date*

Task Description / Reference Examiner's Initials

-180

1. Examination administration date confirmed (C.l.a; C.2.a & b)

-120

2. NRC examiners and facility contact assigned (C.1.d; C.2.e)

-120

3. Facility contact briefed on security & other requirements (C.2.c)

V

-120

4. Corporate notification letter sent (C.2.d)

[-90]

[5. Reference material due (C.l.e; C.3.c)]

-75

6. Integrated examination outline(s) due (C.1.e & f; C.3.d)

-70

7. Examination outline(s) reviewed by NRC and feedback provided to facility licensee (C.2.h; C.3.e)

-45

8. Proposed examinations, supporting documentation, and reference materials due (C.1.e, f, g & h; C.3.d)

-14

10. Final license applications due and assignment sheet prepared (C.1.1; C.2.g; ES-202)

-14

11. Examination approved by NRC supervisor for facility licensee review (C.2.h; C.3.f)

-14

12. Examinations reviewed with facility licensee (C.1.j; C.2.f & h; C.3.g)

-7

13. Written examinations and operating tests approved by NRC supervisor (C.2.i; C.3.h)

-7

14. Final applications reviewed; assignment sheet updated; waiver letters sent (C.2.g, ES-204)

I

15. Proctoring/written exam administration guidelines reviewed with

-7 facility licensee and authorization granted to give written exams (if applicable) (C.3.k)

-7

16. Approved scenarios, job performance measures, and questions distributed to NRC examiners (C.3.i)

Target dates are keyed to the examination date identified in the corporate notification letter.

They are for planning purposes and may be adjusted on a case-by-case basis in coordination with the facility licensee.

Applies only to examinations prepared by the NRC.

NUREG-1021, Revision 8, Supplement 1 22 of 24

ES-201 Examination Outline Form ES-201-2 Quality Checklist Facility: I*A,ýA SýOc uX 3

Date of Examination:

oJ"* "*i-z1 oo.

Initials Item Task Description a

c

1.
a. Verify that the outline(s) fit(s) the appropriate model per ES-401.°s w

R

b. Assess whether the outline was systematically and randomly prepared in accordance with I

Section D.1 of ES-401 and whether all K/A categories are appropriately sampled.

T T

c. Assess whether the outline over-emphasizes any systems, evolutions, or generic topics.

E N

d. Assess whether the justifications for deselected or rejected K/A statements are appropriate.
2.
a. Using Form ES-301-5, verify that the proposed scenario sets cover the required number of normal evolutions, instrument and component failures, and major transients.

S I

b. Assess whether there are enough scenario sets (and spares) to test the projected number and M

mix of applicants in accordance with the expected crew composition and rotation schedule without compromising exam integrity; ensure each applicant can be tested using at least one new or significantly modified scenario, that no scenarios are duplicated from the applicants' audit test(s)*,

and scenarios will not be repeated over successive days.

c. To the extent possible, assess whether the outline(s) conform(s) with the qualitative and quantitative criteria specified on Form ES-301-4 and described in Appendix D.

-A

3.
a. Verify that:

(1) the outline(s) contain(s) the required number of control room and in-plant tasks, A

W (2) no more than 30% of the test material is repeated from the last NRC examination,

/

(3)* no tasks are duplicated from the applicants' audit test(s), and T

(4) no more than 80% of any operating test is taken directly from the licensee's exam banks.

b. Verify that:

(1) the tasks are distributed among the safety function groupings as specified in ES-301, (2) one task is conducted in a low-power or shutdown condition, (3) 40% of the tasks require the applicant to implement an alternate path procedure, (4) one in-plant task tests the applicant's response to an emergency or abnormal condition, and (5) the in-plant walk-through requires the applicant to enter the RCA.

c. Verify that the required administrative topics are covered, with emphasis on performance based activities.A
d. Determine if there are enough different outlines to test the projected number and mix of applicants and ensure that no items are duplicated on successive days.
4.
a. Assess whether plant-specific priorities (including PRA and IPE insights) are covered in the appropriate exam section.

G E

b. Assess whether the 10 CFR 55.41143 and 55.45 sampling is appropriate.

N E

c. Ensure that K/A importance ratings (except for plant-specific priorities) are at least 2.5.

RR A

d. Check for duplication and overlap among exam sections.
e. Check the entire exam for balance of coverage.
f. Assess whether the exam fits the appropriate job level (RO or SRO).

n.n Jdned Name / Signature D

l~"-L

/

at

a. Author Zoq*tKyc../,J'P..l.aiff-.O.*-

/j/-

JJj.*-

b.Fcility Reviewer('

11A) L)Aj

c. NRC Chief Examiner (f:
d. NRC Supervisor C

kk-

,l

)

  • _*j Note:
  • Not applicable for NRC-developed examinations.
  1. Independent NRC reviewer initial items in Column *c;* chief examiner concurrence required.

23 of 24 NUREG-1021, Revision 8, Supplement 1

ES-201 Examination Security Agreement Form ES-201-3

1.

Pre-Examination I acknowledge that I have acquired specialized knowledge about the NRC licensing examinations scheduled for the week(s) of o.as of the date of my signature. I agree that I will not knowingly divulge any information about these examinations to any persons who hav not been authorized by the NRC chief examiner. I understand that I am not to Instruct, evaluate, or provide performance feedback to those applicants scheduled to be administered these licensing examinations from this date until completion of examination administration, except as specifically noted below and authorized by the NRC.Furthermore, I am aware of the physical security measures and requirements (as documented in the facility licensee's procedures) and understand that violation of the conditions of this agreement may result in cancellation of the examinations and/or an enforcement action against me or the facility licensee. I will Immediately report to facility management or the NRC chief examiner any Indications or suggestions that examination security may have been compromised.

2.

Post-Examination To the best of my knowledge, I did not divulge to any unauthorized persons any information concerning the NRC licensing examinations administered during the week(s) of I - o2, From the date that I entered into this security agreement until the completion of examination administration, I did not instruct, evaluate, or provide performance feedback to those applicants who were administered these licensing examinations, except as specifically noted below and authorized by the NRC.

PRINTED NAME JOB TITLE I RESPONSIBILITY SIGNATURE (1)

DATE SIGNATURE (2) DATENOTE NOTES:

NUREG-1021, Revision 8, Supplement 1 24 of 24

ES-301 Operating Test Quality Checklist Form ES-301-3 Facility: fAA\\*'N\\1-u',"-L.,)

Z Date of Examination:

ZaoZ OPerating Test NumberO01 Initials

1. GENERAL CRITERIA
a.

The operating test conforms with the previously approved outline; changes are consistent with sampling requirements (e.g., 10 CFR 55.45, operational importance, safety function distribution).

b.

There is no day-to-day repetition between this and other operating tests to be administered during this examination.

c.

The operating test shall not duplicate items from the applicants' audit test(s)(see Section D*..a).

d.

Overiap with the written examination and between operating test categories is within acceptable

)

limits.

e.

It appears that the operating test will differentiate between competent and less-than-competent applicants at the designated license level.

2. WALK-THROUGH (CATEGORY A & B) CRITERIA
a.

Each JPM includes the following, as applicable:

initial conditions initiating cues references and tools, including associated procedures reasonable and validated time limits (average time allowed for completion) and specific designation if deemed to be time critical by the facility licensee specific performance criteria that include:

- detailed expected actions with exact criteria and nomenclature

- system response and other examiner cues

- statements describing important observations to be made by the applicant

- criteria for successful completion of the task

- identification of critical steps and their associated performance standards restrictions on the sequence of steps, if applicable

b.

The prescripted questions in Category A are predominantly open reference and meet the criteada in Attachment 1 of ES-301.

C. Rptiinfrmoertn tests used during the previous licensing examination is within t

bv acceptable limits (30% for the walk-througlh) and do not compromise test integrity.

d.

At least 20 percent of the JPMs on each test are new or significantly modified.

a.

The associated simulator operating tests (scenario sets) have been reviewed in accordance with Form ES-3014 and a cop is attached.

Si t

e Date

a. Author U) e L
b. Facility Reviewer(*)

/

c. NRC Chief Examiner (#)
d. NRC Supervisor

,\\

23 of 26 NUREG-1021, Revision 8, Supplement 1 NOTE:

  • The facility signature is not applicable for NRC-developed tests.
  1. Independent NRC reviewer initial items in Column "c;" chief examiner concurrence required.

I I

ES-301 Simulator Scenario Quality Checklist Form ES-301-4 4- -1

,4 C

`7 1" ý SceA~

nario Numbers: I I2/ Z Ooeraino Test No.: Lo, T QUALITATIVE ATTRIBUTES Initials a-b c#

1.

The initial conditions are realistic, in that some equipment andfor instrumentation may be out of service, but it does not cue the operators into expected events.

2.

The scenanios consist mostly of related events.

3.

Each event description consists of the point in the scenario when it is to be initiated the malfunction(s) that are entered to initiate the event the symptoms/cues that will be visible to the crew the expected operator actions (by shift position)

4.

No more than one non-mechanistic failure (e.g.. pipe break) is incorporated into the scenario

6.

Sequencing and timing of events is reasonable, and allows the examination team to obtain have sufficient time to carry out expected activities without undue time constraints, Cues are ~ 1 given.4

a.

The simulator modeling is not altered.

9.

The scenarios have been validated. Any open simulator performance deficiencies have been evaluated to ensure that functional fidelity is maintained while running the planned scenarios.

10.

Every operator will be evaluated using at least one new or significantly modified scenario. All other scenarios have been altered in accordance with Section DA4 of ES-301.

the form along with the simulator scenarios).

12.

Each applicant will be significanitly involved in the minimum number of transients and events 13 specified on Form ES-301-5 (submit the form with the simulator scenarios).

1.

The level of difficulty is appropriate to support licensing decisions for each crew position.

D TARGET QUANTITATIVE ATTRIBUTES (PER SCENARIO; SEE SECTION D.4.D)

Actual Attnibutes

1.

Total malfunctions (5-8) 1 Y~

G 4

\\

2.

Malfunctions after EOP entry (1-2)

/. /t1

3.

Abnormal events (2-4)

~t

~~

4.

Major transients (1-2)

/,2/

5.

EOPs entered/requiring substantive actions (1-2) 2-

/ -2 /

2.6.

6.

EOP contingencies requiring substantive actions (0-2) 1

/ 0 /

7.

Critical tasks (2-3) 3

/3/ 3 NUREG-1021, Revision 8, Supplement 1 24 of 26

ES-301 Simulator Scenario Quality Checklist Form ES-301-4 a

b C#

1.

The initial conditions are realistic, in that some equipment andlor instrumentation may be out of 44 service, but it does not cue the operators into expected events.

2.

The scenarios consist mostly of related events.

3.

Each event description consists of the point in the scenario when it is to be initiated the malfunction(s) that are entered to initiate the eventivei the symptoms/cues that will be visible to the crew y

the expected operator actions (by shift position) the event termination int (if applicable)

4.

No more to ene tha nistic failure (e.g., pipe break) is incorporated into the scenado without a credible Preceding incident such as a seismic event.

m d

r

5.

The events are valid with regard to physics and thermodynamics.

D E

6.

Sequencing and timing of eventcis reasonable, and allows the examination team to obtai t

complete evaluation results commensurate with the scenario objectives.

A b

7.

If time compression techniques are used, the scenario summary cleary so indicates. operators have sufficient time to carry out expected activities without undue time constraints. Cues are I

liven.

8.

The simulator modelin2 is not altered.

9.

The scenarios have been validated. Any open simulator performance deficiencies have been evaluated to ensure that functional fidelity is maintained while running the planned scenarios.

10.

Every operator will be evaluated using at least one new or significantly modified scenario. All

[

other scenarios have been altered in accordance with Section D.4 of ES-301.

11.

All individual operator competencies can be evaluated, as verified using Form ES-301-6 (submit the form along with the simulator scenarios).

12.

Each applicant will be significantly involved in the minimum number of transients and events "I

specified on Form ES-301-5 Jsubmit the form with the simulator scenarios).

13.

The level of difficulty is appropriate to support licensin 1 decisions for each crw osit~ion.

TARGET QUANTITATIVE ATTR-IBUTES (PER SCENARIO; SEE SECTION D.4.D)

Actual Attributes 1.

Total malfunctions (5-8) 16 1

-/

2.

Malfunctions after EOP entry(1 -2)

3.

Abnormal events (2-4) 3

4.

Major t ransients !1-2 12

,1

5.

EOPs entered/requiring substantive actions (1-2)

6.

EOP continglencies requiring1 substantive actions (0-2)

7.

Critical tasks (2-3)

I NUREG-1021, Revision 8, Supplement 1 24 of 26

ES-301 I ransient ana Lvent Uhc.kiit

rm IQ21CM L

OPERATING TEST NO.:

Z 00 I L 0 I T Instructions:

Author:

NRC Reviewer (1)

Enter the operating test number and Form ES-D-1 event numbers for each evolution type.

(2)

Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.4.d) but must be significant per Section C.2.a of Appendix D.

(3)

Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicant's com ce co t to le minimum requirement.

25 of 26 NUREG-1021, Revision 8, Supplement 1 I ransient and E-vent Checklist lPnrm fQ-*Q1 r

r:

ES-301

ES-301 Transient and Event Checklist Form ES-301-5 OPERATING TEST NO.:

2.-O0 LaOi Aplicant Ev.lution Minimum Scenario Number

  • rype lype Number 4

Reactivity 1

Normal 1

I RO Instrument /

4 5

Component Major 1

Reactivity 1

I

/

Normal 0

As RO Instrument /

2 3

Component Major 1

SRO-I Reactivity 0

Normal 1

\\

As SRO Instrument /

2 5

Component 1

I Major i

/

Reactivity 0

Normal 1

SRO Instrument /

2 Component Major 1

Instructions:

(1)

Enter the operating test number and Form ES-D-1 event numbers for each evolution type.

(2)

Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.4.d) but must be significant per Section C.2.a of Appendix D.

(3)

Whenever practical, both instrument and component malfunctions should be included; only those that require verifia *le actions that provide insight to the applicant's competenc

  • eunt w,

t minimum requirement.

Author:

',Jac

___*(__*_*

NRC Reviewer:

25 of 26 NUREG-1021, Revision 8, Supplement 1 I

ES-301 Competencies Checklist Form ES-301-6 Applicant #1 Applicant #2 ant #3

  • OJSRO-I/SRO-U C--SRO-I/SRO-U ROCSRO-ISRO-U Competencies SCENARIO SCENARIO SCENARIO 1

24 1

2 'X 4

1 2'

4 Understand and Interpret 1,2,3 1,2,3 AL 2,

L, 4

Annunciators and Alarms 5

L-Diagnose Events 2,3,.S Z. 3.

2,.

2,.

1,+ z, 3 Z,ý,

2, and Conditions

,b.

6 Understand Plant zL 3LL ALLLL AL ALL ALL 4LL and System Response L

A Comply With and 2,

Z,4, 3AL Use Procedures (1)

ALL ALL 5,, 1.1 ALL ALL

.4L Operate Control A,

2

.2 3.4 Boards (2) 4L 4L-4 Communicate and ALL ALL ALL ALL ALL ALL-LL ALL A -L Interact With the Crew Demonstrate Supervisory AL-L ALL A LL Ability (3)

Comply With and 3

2-2..

Use Tech. Specs. (3)

Notes:

(1) Includes Technical Specification compliance for an RO.

(2) Optional for an SRO-U.

(3) Only applicable to SROs.

Instructions:

Circle the applicant's license type and enter one or more event numbers that will allow the examiners to evaluate ev applicable c pe cyc r every applicant.

Author:

NRC Reviewer:

NUREG-1021, Revision 8, Supplement 1 26 of 26 I

ES-401 Written Examination Form ES-401-7 Quality Checklist Facility:

Date of Exam:

I j '-

O0" Exam Level: QSRO Initial Item Description a

b.

c#

1.

Questions and answers technically accurate and applicable to facility

- 4

2.
a. NRC K/As referenced for all questions
b. Facility leaming objectives referenced as available LL
3.

RO/SRO overlap is no more than 75 percent, and SRO questions are appropriate Q

per Section D.2.d of ES-401

4.

Question selection and duplication from the last two NRC licensing exams appears consistent with a systematic sampling process

5.

Question duplication from the license screening/audit exam was controlled as indicated below (check the item that applies) and appears appropriate:

the audit exam was systematically and randomly developed; or the audit exam was completed before the license exam was started; or i.t-Ihe examinations were developed independently; or

_ the licensee certifies that there is no duplication; or

- other (explain)

6.

Bank use meets limits (no more than 75 Bank Modified Nev.,

percent from the bank at least 10 percent new,

_11W and the rest modified); enter the actual question

.j 7

distribution at right

7.

Between 50 and 60 percent of the questions on Memory,_/

C/A the exam (including 10 new questions) are "I

written at the comprehension/analysis level;

% 2.

enter the actual question distribution at right

8.

References/handouts provided do not give away answers

9.

Question content conforms with specific KIA statements in the previously approved examination outline and is appropriate for the Tier to which they are assigned; deviations are justified

10.

Question psychometric quality and format meet ES, Appendix B, guidelines

11.

The exam contains 100, one-point, multiple choice items; the total is correct and g

")

agrees with value on cover sheet Printed Name / Signature Date

a. Author

/-/491

b. Facility Reviewer (*)7-/v

/

c. NRC Chief Examiner (#)

i C

d. NRC Regional Supervisor Note:

The facility reviewer's initials/signature are not applicable for NRC-developed examinations.

  1. Independent NRC reviewer initial items in Column "c;" chief examiner concurrence required.

NUREG-1021, Revision 8, Supplement 1 42 of 46 t o

ES-401 Written Examination Form ES-401-7 Quality Checklist Facility:

Date of Exam:

2--

Exam Level: RO`

Initial Item Description a

b*

c#

1.

Questions and answers technically accurate and applicable to facility

/

[

2.
a. NRC KJAs referenced for all questions

/

b. Facility learning objectives referenced as available oter expain
3.

BnRO/SRO overlap is no more than 75 percent, and SRO questions are appropriate

4.

Question selection and duplication from the last two NRC licensing examsn appears consistent with a systematic sampling process

5.

Question duplication from the license screening/audit exam was controlled as indicated below (check the item that applies) and appears appropriate:

the audit exam was systematically and randomly developed; or writhe audit exam was completed before the license exam was started; or entere examinations were developed independently; or 9 Q the licensee certifies that there is no duplication; or a other (explain) oo

6.

Bank use meets limios a(no more than 75 tBank lodified iNew percent from the bank at least 10 percent new, A

n B g di.theuexand the rest modified); enter the actual question ems the t

  • oa ic an
7.

Between50an de0 percent of the questions ono Memor C/

written at the comprehensionlanalysis level; Ise enter the actual question distribution at right n

D

8.

References/handouts provided do not give away answers

9.

Question content conforms with specific K/A statements in the previously approved examination outline and is appropriate for the Tier to which they are

/

assigned; deviations are justified

10.

Question psychometric quality and format meet ES, Appendix B, f

uidelines exaintins

11.

The exam contains 100, one-point, multiple choice items; the total is correct and required.

Printed Name / Signature Date

a. Author l) l.-*l" f* v

¢

/.

b. Facility Reviewer R*

R

.,Z" 7-/'1" AJ 5(:*

  • l~1*.'l*M
c. NRC Chief Examiner (#)
d. NRC Regional Supervisor CZ.J

_LC*,*

",7 C_'L

'LO*

Note:

  • The facility reviewer's in iti als/sig nature are not applicable for NRC-developed examinations.
  1. Independent NRC reviewer initial items in Column "c;" chief examiner concurrence required.

NUREG-1021, Revision 8, Supplement 1 42of46 6wC

,Vv(

,101 I

ES-403 Written Examination Grading Form ES-403-1 Quality Checklist

[Facility:

//*

s Ii, 3

Date of Exam:

I-Y Exam Level' l

Initials Item Description a

b c

1.

Clean answer sheets copied before grading

2.

Answer key changes and question deletions justified and documented N

4A

3.

Applicants' scores checked for addition errors (reviewers spot check > 25% of examinations)

4.

Grading for all borderline cases (80% +/- 2%) reviewed in detail A/A

5.

All other failing examinations checked to ensure that grades

]-7 "

are justified____

6.

Performance on missed questions checked for training deficiencies and wording problems; evaluate validity of questions missed by half or more of the applicants Printed Name / Signature Date

a. Grader

/0-I/S -C

b. Facility Reviewer(*)

6 1-'J/4d U

/

z_

c. NRC Chief Examiner ()44~/~
d. NRC Supervisor (*)

-E

(*)

The facility reviewer's signature is not applicable for examinations graded by the NRC; two independent NRC reviews are required.

5 of 5 NUREG-1021, Revision 8, Supplement 1 I