ML020660505

From kanterella
Jump to navigation Jump to search
Submittal of Synopsis of NRC OI Completed Report 2-2001-003 for Turkey Point Nuclear Plant Re Alleged Falsification of Quality Assurance Records Re Performance of Appendix R Lighting Surveillance & Subsequent Management Coverup
ML020660505
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 03/06/2002
From: Scott Sparks
NRC/RGN-II
To: Stall J
Florida Power & Light Co
References
2-2001-1003
Download: ML020660505 (6)


Text

March 6, 2002 Florida Power & Light Company ATTN: Mr. J. A. Stall, Senior Vice President Nuclear and Nuclear Chief Officer PO Box 14000 Juno Beach, FL 33408-0420

SUBJECT:

TURKEY POINT NUCLEAR PLANT: NUCLEAR REGULATORY COMMISSION OFFICE OF INVESTIGATIONS CASE NUMBER 2-2001-003

Dear Mr. Stall:

Enclosed for your information is the synopsis of the Nuclear Regulatory Commission (NRC)

Office of Investigations (OI) completed report regarding alleged falsification of quality assurance records regarding performance of an Appendix R Lighting Surveillance, and subsequent alleged management coverup of the falsification. OI did not substantiate that quality assurance records were falsified or that management attempted to cover up the alleged falsification.

Based on the OI activity described in the synopsis, we plan no further action with regard to this matter. Should you have any questions concerning this letter, please contact us.

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter and the enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS).

ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Scott E. Sparks Senior Enforcement Specialist Docket Nos. 50-250, 50-251 License Nos. DPR-31, DPR-41

Enclosure:

Investigative Synopsis, OI Case No. 2-2001-003 cc w/encl: See Page 2

Florida Power and Light Company 2 cc w/encl:

T. O. Jones Plant General Manager Turkey Point Nuclear Plant Florida Power and Light Company Electronic Mail Distribution John P. McElwain Site Vice President Turkey Point Nuclear Plant Florida Power and Light Company 9760 SW 344th Street Florida City, FL 33035 Olga Hanek Acting Licensing Manager Turkey Point Nuclear Plant Florida Power and Light Company Electronic Mail Distribution M. S. Ross, Attorney Florida Power & Light Company Electronic Mail Distribution

Distribution:

RII-2001-A-0014 S. Ninh O. de Miranda PUBLIC OFFICE DRP/RII SIGNATURE NAME SNINH DATE 03/06/02 COPY?

YES NO YES NO YES NO YES NO YES NO OFFICIAL RECORD COPY DOCUMENT NAME: C:\\Program Files\\Adobe\\Acrobat 4.0\\PDF Output\\LTRTOLIC.WPD

NOT FOR PUBLIC DISCLOSURE WITHOUT APPROVAL OF FIELD OFFICE DIRECTOR, OFFICE OF INVESTIGATIONS, REGION II Case No. 2-2001-003 1

SYNOPSIS The Office of Investigations (OI), U.S. Nuclear Regulatory Commission (NRC), Region II (RII),

initiated this investigation on March 16, 2001, after a Turkey Point Nuclear Plant electrician alleged an electrical maintenance foreman falsified quality assurance records regarding performance of Appendix R Lighting Surveillance. The electrician further alleged that licensee management attempted to cover up the falsification.

Investigation disclosed the underlying issue had been previously identified and investigated by licensee through their employee concerns "Speakout" program. Licensee immediately reported the issue to the NRC. Upon interview, the alleger retracted the claim that licensee management attempted to cover up the falsification, but voiced the concern that licensee took insufficient corrective action against the foreman.

OI did not substantiate that licensee falsified quality assurance records or attempted to cover up the alleged falsification. OI defers to the RII staff regarding the appropriateness of licensees corrective action.

Approved for release on 3/6/2 Enclosure